AudioCORTI Plus

Clinical Audiometer Two Chanel

 AIR CONDUCTION
 BONE CONDUCTION
 MASKING
 SPEECH TEST
 FREE FIEND OUTPUT
 TALK BACK – TALK OVER
 SISI – ABLB – DECAY – BEKESY
 TINNITUS TEST
 HF 20.000 Hz
 Free Field Amplifier Built-In

SCREENING AND CLINICAL MODES IN ONE DEVICE


AudioCORTI advanced

technology in a small space

With a weight of only 250


grams, AudioCORTI is so small
it can be conveniently carried
in your bag together with
your laptop.
However, when you turn it
on, it becomes great, and
rivals any 2-channel
audiometer.

A click on your mouse or on


the keyboard, and
AudioCORTI displays
audiograms during test and
stores them in your database
until you need to print them.

AudioCORTI is not out of words.

It is not necessary to connect an external CD player


to AudioCORTI. In its internal Flash Memory,
AudioCORTI has lists of words that can be presented
to the patient at the selected intensity. Just in case,
AudioCORTI has inputs for the 2 channels where an
external CD or MP3 can be connected, so that there
is no limitation to the speech material that can be
utilized
High frequency

The high frequency test includes


high-frequency headphones and
uses pure tones up to 20,000 Hz.

High power
Two high-powered speakers are
available for free-field testing.

All necessary connections are on the back of the device


SPECIAL TEST

SISI TEST ABLB DECAY TEST

BEKESY HF up 20 Kz

TINNITUS in few step easy and fast

The first step is basic, a The second step allows us to We calculate the dynamics
normal high frequency identify the frequency of of Tinnitus, threshold and
binaural audiometry Tinnitus level of perception

We calculate the dynamics of the Last step, check the level of the masker,
masking, threshold and level of thanks to the built-in chronometer we
disappearance of Tinnitus and check the inhibition level after
Verification of the level of discomfort, it application for one minute, if the
is important to have all the data for a inhibition is not total, we can simply test
correct application of the masker higher intensities
VERSION AUDIOCORTI PLUS
 Version Plus include : Air Conduction – Bone Conduction – Masking – Speech Test,
Free Field Built-In, External Speakers, Special Test , Tinnitus, Talk-Back Talk-Over,
External microphone, Software Data Base

TECHNICAL SPECIFICATION

Via Giotto, 9/B


31021 – Mogliano Veneto (TV) – ITALY
Th. +390417128031 – info@audiocorti.com