Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Data sheet for three-phase Squirrel-Cage-Motors

MLFB-Ordering data : 1LA6106-4AA90-Z


B02+C19+E00+L12+L1Y

Client order no. : Item no. :


Order no. : Consignment no. :
Offer no. : Project :
Remarks :

Electrical data: General data:


Rated voltage : Frame size
Special voltage, non-standard winding 100 L

Frequency : Design of electrical machine : (0) IM B3 / B6 / B7 / B8 / V5


50 Hz without canopy
Rated power : Weight in kg, without optional accessories :
33.00 kg

Rated speed : Frame material :


Cast iron
Degree of protection :
Rated torque : IP 55
Method of cooling, TEFC :
Rated current (IE) : VD VY VD VY IC 411
Vibration class :
A (Standard)
Starting / rated current :
Insulation :
Breakdown / rated torque :
Duty type :
S1 - continuous duty
Starting / rated torque :
Direction of rotation :
Bi-directional
4/4 3/4 2/4
Efficiency %
79.7% 80.0% 78.7%
Terminal box:
Power factor :
0.82 0.77 0.67
Material of terminal box :
Efficiency class : IE1
Type of terminal box :
gk 135
Mechanical data: Contact screw thread :
Sound pressure level 50Hz/60Hz (load) :
53 dB(A)
Max. cross-sectional area :
Moment of inertia :
0.0047 kg*m² Cable diameter from ... to ... :
Bearing DE :
6206 2ZC3 Cable entry :
Bearing NDE :
6205 2ZC3 Cable gland :
Type of bearing :
Floating bearings pre-loaded DE (standard)
Special design:
Condensate drainage holes :
Yes B02 Acceptance test certificate 3.1 acc. to EN 10204

Regreasing device : C19 Increased air humidity/temperature with 30-60g water per m³ air
No
E00 ABS KT 50°C / RINa KT45°C, without certificate 155(F)/155(F)
Lubricants :
Esso Unirex N3
L12 Condensation drain holes
Grease lifetime/Relubrication interval : L1Y Voltage code 9 non-standard winding:

Quantity of grease for relubrication :


null g

External earthing terminal :


No

Coating :
Special paint finish RAL 7030 stone gray

Environmental conditions:
Ambient temperature :
-20 °C - +50 °C

Altitude above sea level :


1000 m

Standards and specifications :


IEC, DIN, ISO, VDE, EN

Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Generated: 14.02.2024 13:31:26