This manual describes the maintenance procedures that differ from procedures with standard printers
when the IP6-777 extra ionizer kit is installed. For procedures not mentioned in this manual, refer to the
Maintenace Manual for the standard printers.
LED
Description of LEDs
POWER: Lights up when the power is turned on.
H.V ALARM: Lights up when there is a problem with the power supply.
FAN ALARM: Lights up when there is a problem with the fan.
1
Oki Data CONFIDENTIAL
3. Operating the extra ionizers from the ACTUATORS menu and the Actuator tab
Setting
System
Subscription code
Language
Date format
Time zone
Length unit
Temperature unit
Warning sound
PH uncapped
TUR open/timeout
Ink errors
Part replacement warning
Detect media width (before system firmware ver. 3.00 only)
Detect media (before system firmware ver. 3.00 only)
Jam detection sensitivity
Nozzle sweeping
Set all settings to default
Date setting
Time setting
Serial number
Initialize EEPROM
Save default settings
Load default settings
Save printer settings
Load printer settings
Number of colors (CIS model only)
Ink system status
Media heater settings
Print end heating
Standby time
Standby temperature
Actuators
Heaters
Media heaters
Print head heaters
Fans
Rear fans
Carriage fans
2
Oki Data CONFIDENTIAL
Exhaust fan
Suction fan 1
Suction fan 2
Suction fan 3
Suction fan 4
Motors
Pump/Wipe motor
Cap motor
TUR unit motor
Ink supply motor 1
Ink supply motor 2
Ink supply motor 3
Ink supply motor 4
Ink supply motor 5
Ink supply motor 6
Ink supply motor 7
Solenoids
Air release solenoid 1
Air release solenoid 2
Air release solenoid 3
TUR electromagnetic clutch
LEDS
LED for red
LED for green
LED for blue
Ionizers
EXTRA IONIZERS
Printer power
3
Oki Data CONFIDENTIAL
>>ACTUATORS
EXTRA IONIZERS ◎
Select EXTRA IONIZERS with the Up and Down buttons, and then press the OK button.
Select a parameter with the Up and Down buttons, and then press the OK button.
>>>EXTRA IONIZERS
YYY ◎
4
Oki Data CONFIDENTIAL
5
Oki Data CONFIDENTIAL
4. Troubleshooting (General)
6
Oki Data CONFIDENTIAL
7
Oki Data CONFIDENTIAL
[Symptom A]
Reference
Service Engineer Assumed to Check/
Cause User Solution
Inspection Replacement Part Replace
Parts
Media feed is not Adjust the media advance adjustment value. - Install the last firmware - Firmware version
adjusted properly. * The media advance adjustment value differs depending on the version. - PRINT HAED
winding mode, loose or tension. - Check that the nozzles - CAP, MW
- Be sure to adjust the media advance adjustment value again after eject ink correctly. - WIPING UNIT,MW
changing the winding mode (loose or tension). - Check the cap position.
- Be sure to adjust the media advance adjustment value again after - Check that ink is sucked
changing the pressure roller lever position. when performing the FILL
- Be sure to adjust the media advance adjustment value again after CAP or PH.RECOVERY
changing the suction fan setting of the media preset. operation.
The media advance (1) Check that the media was installed properly in the conditions - Check the wiping unit
accuracy is poor, or below. operation.
is not stable. - The installed media is installed parallel to the printer. - Check the wiping position.
- The operation panel shows the media type correctly.
- The media winding mode is optimal for the installed media.
- If the media is curled or wrinkled, see the description on the
problem, The media is curled or wrinkled.
(2) Adjust the pressure on the media with the pressure roller lever. *1
(3) Change the print mode to be slower. *1 *2
(4) Check that the media is correctly stretched between the paper roll
and the pressure roller.
* If the media is loose when performing the media advance
adjustment, the value will be incorrect.
*1 Adjust the media advance adjustment value again.
*2 Note that the print speed differs depending on the mode selected.
8
Oki Data CONFIDENTIAL
[Symptom B]
Reference
Service Engineer Assumed to Check/
Cause User Solution
Inspection Replacement Part Replace
Parts
Print head nozzles (1) Perform a nozzle print, and set nozzle map for the clogged - Install the last firmware - Firmware version
are clogged. nozzles. version. - PRINT HAED
(2) Check for obstructions such as media lint or ink clot in the nozzle - Check that the nozzles - CAP, MW
scanning path including the platen surface, and remove them. eject ink correctly. - WIPING UNIT,MW
(3) If the media is curled or wrinkled, solve the problem by referring - Check the cap position.
to the description on the problem, The media is curled or - Check that ink is sucked
wrinkled. when performing the FILL
(4) Perform the daily maintenance. CAP or PH.RECOVERY
* Do not forget to clean the head guard and media edge guards. operation.
* Be sure to perform the print head cleaning. - Check the wiping unit
(5) Clean the print heads surfaces with print sheet mount cleaning. operation.
(6) When using Nippon Carbide retro-reflective sheeting for road - Check the wiping position.
signs, set the ionizer setting to EXTRA IONIZERS ON. - Check the extra ionizers
operation.
Printing with a color stripe bar is effective to prevent missing dots.
Print head nozzles (1) Print a nozzle print pattern, and set nozzle map for the inclined
inclination. nozzles.
(2) Printing with a color stripe bar is effective to prevent missing dots.
[Symptom C]
Reference
Service Engineer Assumed to Check/
Cause User Solution
Inspection Replacement Part Replace
Parts
The ink does not (1) Decrease the temperature of all three heaters by 5°C. *1 - Install the last firmware - Firmware version
match the media. * Before starting the print, ensure that the heater temperatures have version. - PRINT HAED
(Media with low dot been decreased to the target temperature. - Check that the nozzles - CAP, MW
spread rate) * With some media, the increasing the heater temperatures may be eject ink correctly. - WIPING UNIT,MW
effective. - Check the cap position.
(2) Change the print mode to be slower. *1 *2 - Check that ink is sucked
(3) Use proven media. when performing the FILL
(4) Print in high density. CAP or PH.RECOVERY
operation.
- Check the wiping unit
operation.
- Check the wiping position.
*1 Adjust the media advance adjustment value again.
*2 Note that the print speed differs depending on the mode selected.
9
Oki Data CONFIDENTIAL
6. Error Messages
Table of errors
<Extra ionizers errors>
Service Engineer Inspection
(For inspection criteria, see Assumed
Panel Message Error Description User Solution
Reference to Check/Replace Replacement Part
Parts.)
The extra ionizers - Press any key to clear the - Check that the connector to - PCB-ASSY-HCB1N
CHECK EXTRA IONIZERS
connector to the board error. the HCB1N board is correctly - Extra ionizers
CONNECTION TO BOARD ◎ is not connected - Contact your service connected. connection harnesses
properly. representative. - Check that the extra ionizers
connection harnesses are not
broken.
The connector of the - Press any key to clear the - Check that the connector of - PCB-ASSY-HCB1N
CHECK RIGHT EXTRA
extra ionizer on the error. the extra ionizer on the right - Extra ionizer
IONIZER CONNECTION ◎ right side is not - Check the connector of the side is correctly connected. connection harness
connected properly. extra ionizer on the right - Check that the connector to - Extra ionizer
side, and connect it if it is the HCB1N board is correctly
not connected. connected.
- Check that the extra ionizer
connection harness is not
broken.
The connector of the - Press any key to clear the - Check that the connector of - PCB-ASSY-HCB1N
CHECK LEFT EXTRA
extra ionizer on the left error. the extra ionizer on the left - Extra ionizer
IONIZER CONNECTION ◎ side is not connected - Check the connector of the side is correctly connected. connection harness
properly. extra ionizer on the left side, - Check that the connector to - Extra ionizer
and connect it if it is not the HCB1N board is correctly
connected. connected.
- Check that the extra ionizer
connection harness is not
broken.
The connectors of the - Press any key to clear the - Check that the connectors of - PCB-ASSY-HCB1N
CHECK R & L EXTRA extra ionizers on both error. the extra ionizers on both - Extra ionizer
IONIZERS CONNECTION ◎ sides are not - Check the connectors of the sides are correctly connected. connection harnesses
connected properly. extra ionizers on both sides, - Check that the connector to - Extra ionizer
and connect them if they are the HCB1N board is correctly
not connected. connected.
- Check that the extra ionizers
connection harnesses are not
broken.
A problem has been - Press any key to clear the - Check the power switch of the - PCB-ASSY-HCB1N
CHECK RIGHT EXTRA
detected with the extra error. extra ionizer on the right side. - Extra ionizer
IONIZER ◎ ionizer on the right - Check the power switch of - Check the alarm LEDs of the connection harness
side. the extra ionizer on the right extra ionizer on the right side. - Extra ionizer
side, and turn it on if it is - Check that the extra ionizer
turned off. connection harness is not
- If this error occurs broken.
regardless of the power
switch being turned on,
contact your service
representative.
A problem has been - Press any key to clear the - Check the power switch of the - PCB-ASSY-HCB1N
CHECK LEFT EXTRA
detected with the extra error. extra ionizer on the left side. - Extra ionizer
IONIZER ◎ ionizer on the left side. - Check the power switch of - Check the alarm LEDs of the connection harness
the extra ionizer on the left extra ionizer on the left side. - Extra ionizer
side, and turn it on if it is - Check that the extra ionizer
turned off. connection harness is not
- If this error occurs broken.
regardless of the power
switch being turned on,
contact your service
representative.
10
Oki Data CONFIDENTIAL
A problem has been - Press any key to clear the - Check the power switches of - PCB-ASSY-HCB1N
CHECK R & L EXTRA
detected with both error. both extra ionizers. - Extra ionizer
IONIZER ◎ extra ionizers. - Check the power switches of - Check the alarm LEDs of both connection harnesses
both extra ionizers, and turn extra ionizers. - Extra ionizer
them on if they are turned - Check that the extra ionizers
off. connection harnesses are not
- If this error occurs broken.
regardless of the power
switches being turned on,
contact your service
representative.
11
Oki Data CONFIDENTIAL
Errors details
Extra ionizers errors
<Description>
The extra ionizers connector to the board is not connected properly.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check that the connector to the Check that the connectors of the extra ionizers connection
HCB1N board is correctly connected. harnesses are correctly connected to the connectors on
the HCB1N board.
2 Check that the extra ionizers Check that the extra ionizers connection harnesses are
connection harnesses are not broken. not damaged or broken.
3 PCB-ASSY-HCB1N Replace the board.
<Description>
The connector of the extra ionizer on the right side is not connected properly.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check that the connector of the extra Check that the connector of the extra ionizer connection
ionizer on the right side is correctly harness is correctly connected to the connector on the
connected. extra ionizer.
2 Check that the connector to the Check that the connector of the extra ionizer connection
HCB1N board is correctly connected. harness is correctly connected to the connector on the
HCB1N board.
3 Check that the extra ionizer Check that the extra ionizer connection harness is not
connection harness is not broken. damaged or broken.
4 Extra ionizer Replace the extra ionizer.
12
Oki Data CONFIDENTIAL
<Description>
The connector of the extra ionizer on the left side is not connected properly.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check that the connector of the extra Check that the connector of the extra ionizer connection
ionizer on the left side is correctly harness is correctly connected to the connector on the
connected. extra ionizer.
2 Check that the connector to the Check that the connector of the extra ionizer connection
HCB1N board is correctly connected. harness is correctly connected to the connector on the
HCB1N board.
3 Check that the extra ionizer Check that the extra ionizer connection harness is not
connection harness is not broken. damaged or broken.
4 Extra ionizer Replace the extra ionizer.
<Description>
The connectors of the extra ionizers on both sides are not connected properly.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check that the connectors of the extra Check that the connectors of the extra ionizers connection
ionizers on both sides are correctly harnesses are correctly connected to the connectors on
connected. the extra ionizers.
2 Check that the connector to the Check that the connectors of the extra ionizers connection
HCB1N board is correctly connected. harnesses are correctly connected to the connectors on
the HCB1N board.
3 Check that the extra ionizers Check that the extra ionizers connection harnesses are
connection harnesses are not broken. not damaged or broken.
4 Extra ionizers Replace the extra ionizers.
13
Oki Data CONFIDENTIAL
<Description>
A problem has been detected with the extra ionizer on the right side.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check the power switch of the extra Turn the power switch on if it is turned off.
ionizer on the right side.
2 Check the alarm LEDs of the extra If the alarm LEDs of the extra ionizer are lit, replace the
ionizer on the right side. extra ionizer.
3 Check that the extra ionizer Check that the extra ionizer connection harness is not
connection harness is not broken. damaged or broken.
<Description>
A problem has been detected with the extra ionizer on the left side.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check the power switch of the extra Turn the power switch on if it is turned off.
ionizer on the left side.
2 Check the alarm LEDs of the extra If the alarm LEDs of the extra ionizer are lit, replace the
ionizer on the left side. extra ionizer.
3 Check that the extra ionizer Check that the extra ionizer connection harness is not
connection harness is not broken. damaged or broken.
14
Oki Data CONFIDENTIAL
<Description>
A problem has been detected with both extra ionizers.
<Action>
Check the Items to be Checked on the table below, and perform the actions starting from the top until
the problem is solved.
1 Check the power switches of both Turn the power switches on if they are turned off.
extra ionizers.
2 Check the alarm LEDs of both extra If the alarm LEDs of the extra ionizers are lit, replace the
ionizers. extra ionizers.
3 Check that the extra ionizers Check that the extra ionizers connection harnesses are
connection harnesses are not broken. not damaged or broken.
15