MCW - C/F/H - 2013

Technical Manual (50/60Hz)

Ceiling Concealed Chilled Water


Fan Coil Unit (50/60Hz)
Models: MCW200 MCW300 MCW400
  MCW600 MCW800 MCW1000
  MCW1200
Air Flow: 360-2040m3/h

Engineered for flexibility and performance. TM


Literature No.: TM-MCW(C/H/F)-1301A
Supersedes: TM-MCW(C/H/F)-1201A
Part No.: M08039110020

Contents
Nomenclature……………………………………………………………………………………… 2

Valve Nomenclature… …………………………………………………………………………… 4

Features… ………………………………………………………………………………………… 5

Electric Heater Power… ………………………………………………………………………… 5

Specifications……………………………………………………………………………………… 6

Sound Data… ……………………………………………………………………………………… 10

Performance Data-Cooling… …………………………………………………………………… 11

Performance Data-Heating… …………………………………………………………………… 20

Air Flow vs ESP Curve…………………………………………………………………………… 23

Operating Limits…………………………………………………………………………………… 24

Water Flow Rate vs Pressure Drop Chart… ………………………………………………… 25

Outlines and Dimensions……………………………………………………………………… 27

Electrical Data……………………………………………………………………………………… 30

Wiring Diagrams…………………………………………………………………………………… 33

Installation… ……………………………………………………………………………………… 36

Guide Specifications……………………………………………………………………………… 41

Note: Installation and maintenance are to be performed only by qualified personnel who are
familiar with local codes and regulations, and experienced with this type of equipment.

Caution: Sharp edges and coil surfaces are a potential injury hazard. Avoid contact with them.

Warning: Moving machinery and electrical power hazard. May cause severe personal
injury or death. Disconnect and lock off power before servicing equipment.

“McQuay” is a registered trademark of McQuay International. All rights reserved throughout the world.

© 2013 McQuay International

“Bulletin illustrations cover the general appearance of McQuay International products at the time of publication
and we reserve the right to make changes in design and construction at any time without notice.”


Nomenclature
Nomenclature
MCW-C/H/F Series without Electric Heater

MCW 200 C - 8 R B F A A A E

Export

Description of Products
A-Standard Drain Pan
F1-Drain Pan Extended 100mm
F2-Drain Pan Extended 200mm

Material of Drain Pan


A-Coated Cold Rolled Steel
S-Stainless Steel
Power Supply
A - 220V/1Ph/50Hz
K - 208-230V/1Ph/60Hz
N - 115V/1Ph/60Hz
X - Without Filter
F - 8mm Nylon Filter
B-Back Return Air Plenum
D-Bottom Return Air Plenum
C-Without Return Air Plenum
Pipe Connection
R-Facing Air Flow Right Hand
L-Facing Air Flow Left Hand
0 - 0Pa External Static Pressure
3-30Pa External Static Pressure
6-60Pa External Static Pressure
8-80Pa External Static Pressure

"-"-Original Design
"A"-First Design Improve

C-3 Rows and 2 Pipes(3+0)


H-4 Rows and 4 Pipes(3+1)
F-4 Rows and 2 Pipes(4+0)

Nominal Air Flow (CFM)


(CFM,1CFM=1.7m3/h)
McQuay Ceiling Concealed Chilled Water FCU


Nomenclature
MCW-C Series with Electric Heater

MCW 2 CD 10 - 8 R B F A A A E

Export

Description of Products
A-Standard
 Drain pan
F1-Drain Pan Extended 100mm
F2-Drain Pan Extended 200mm

Material of Drain Pan


A-Coated Cold Rolled Steel
S-Stainless Steel
Power Supply
A-220-240V/1Ph/50Hz
F-380V/3Ph/50Hz
K- 208-230V/1Ph/60Hz

Filter
X-without Filter
F-8mm Nylon Filter with Aluminum Frame

B-Back Return Air Plenum


D-Bottom Return Air Plenum
C-without Return Air Plenum

Pipe Connection
R-Facing Air Flow Right Hand
L-Facing Air Flow Left Hand
0 - 0Pa External Static Pressure
3-30Pa External Static Pressure
6-60Pa External Static Pressure
8-80Pa External Static Pressure

"-"-Original Design
"A"-First Design Improve

Power of Electric Heater


05 - 0.5kW
10 - 1.0kW
......

CD -3 Rows and 2 Pipes(3+0), with electric heater

Nominal Air Flow


2 - 200CFM
3 - 300CFM
......
10 - 1000CFM
......

MCW-McQuay Fan Coil Unit


Valve Nomenclature

MCW - 2V 4 Y B R A E
E-Export
U-Stick "Made In China"
Power Supply:
A-220-240V/1Ph/50Hz
K-208-230V/1Ph/60Hz
Pipe Connection
R-for Right hand unit
L-for Left hand unit
Valve Type
B-with Ball Valve
X-without Ball Valve
Strainer Type
Y-with Y-Strainer
X-without Y-Strainer

Union Size
Omitted-R3/4
4-R1

Valve model
2V:2-Way Valve Kit
3V:3-Way Valve Kit

MCW-McQuay FCU
(Only 2-pipe system is applicable)


Features
Extra Low Noise Design
Enlarged fan wheels design allows lower fan RPM selection for the same external static pressure and airflow
requirement. Thereby, noise level is significantly reduced.

Flexibility
Water connection side can be changed easily in the field by changing positions of fan-motor assembly or
the supply air flange assembly. Fan-motor assembly is not cased allowing back return or bottom return
installations. 2-way and 3-way valve kits are optional for 2-pipe system.

High Efficiency Heat Exchanger


A boundary layer film of air adhering to the fin surface will insulate the fin surface and severally reduces the
heat exchange efficiency. Mcquay slit fin design eliminates this boundary layer of air and creates continuous
for best heat exchange efficiency.

Variable External Static Pressure


Four types of external static pressure are available for every unit:0Pa, 30Pa, 60Pa, 80Pa.

Compact Design
This series of fan coil units are designed to suit most ceiling concealed installations. Unit height is only
251mm without plenum across the entire model range. The feature also maximizes provisions for drain fall
requirements. New design realizes all the filters removal both from the side and bottom(Option).

Auxiliary Electric Heater (Only for Type C)


The heating source of Mcquay fan coil unit is PTC (Positive Temperature Coefficient) heater.
1. Safety
A fuse (135°C,10A) is connected in each PTC main wiring circuit. A thermostat (50°C,10A) is connected in
the control wiring circuit. If the fan of the units is not running, the thermostat or fuse will cut off the power
of the unit. In addition the surface of the PTC heater is without electric power. So the fan coil unit is safe
enough.
2. Save Energy
Quick heating spread, strong heating capacity, steady performance and save energy are characters of
PTC heater.

3. Easy To Install And Maintain


Needn’t remove the air duct when maintain the electric components of the units. Please refer to the
corresponding sections for installation and maintenance.

Electric Heater Power


MODEL Power Supply 0.5kW 1.0kW 1.5kW 2.0kW 2.5kW 3.0kW 3.5kW 4.0kW 4.5kW 5.0kW 6.0kW 8.0kW
MCW2CD 220-240V/1Ph/50Hz   
MCW3CD 220-240V/1Ph/50Hz    
MCW4CD 220-240V/1Ph/50Hz   
220-240V/1Ph/50Hz    
MCW6CD
380-415V/3Ph/50Hz    
220-240V/1Ph/50Hz     
MCW8CD
380-415V/3Ph/50Hz     
220-240V/1Ph/50Hz     
MCW10CD
380-415V/3Ph/50Hz     
220-240V/1Ph/50Hz      
MCW12CD
380-415V/3Ph/50Hz      


Specifications
General Data
MCW-C
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
m /h
3
390 530 760 1040 1420 1620 2040
HIGH
CFM 229 312 447 612 835 953 1200
m3/h 260 370 490 780 1090 1140 1500
Air Flow MEDIUM
CFM 153 218 288 459 641 671 882
m3/h 190 240 340 500 740 830 1020
LOW
CFM 112 141 200 294 435 488 600

EXTERNAL STATIC Pa 0,30,60,80


PRESSURE in.wg 0,0.12,0.24,0.32

TOTAL COOLING W 2200 3200 4390 6160 7810 8830 10700


CAPACITY Btu/h 7507 10919 14979 21019 26649 30129 36510

SENSIBLE COOLING W 1738 2359 3242 4401 6040 6409 7763


CAPACITY Btu/h 5930 8049 11062 15017 20609 21868 26488

TOTAL HEATING W 3500 5100 7300 9960 13080 14780 19170


CAPACITY Btu/h 11942 17402 24909 33985 44631 50431 65411
m /h
3
0.4 0.6 0.8 1.1 1.4 1.6 1.9
WATER FLOW RATE
USGPM 1.8 2.5 3.4 4.8 6.1 6.9 8.5
kPa 14.6 12.0 21.6 38.2 18.4 21.0 32.7
HEAD LOSS (COOLING)
in.wg. 58.4 48.0 86.4 152.8 73.6 84.0 130.8

UNIT HEIGHT mm 251 251 251 251 251 251 251


DIMENSIONS

DIMEN- WIDTH mm 714 884 1014 1214 1464 1564 1824


SIONS DEPTH mm 556 556 556 556 556 556 556
HEIGHT mm 260 260 260 260 260 260 260
PACKING
DIMEN- WIDTH mm 724 894 1024 1224 1474 1574 1834
SION
DEPTH mm 570 570 570 570 570 570 570

UNIT WEIGHT kg 19.0 20.0 26.0 30.0 41.0 44.0 46.0


(Without plenum) lb 41.9 44.1 57.3 66.1 90.4 97.0 101.4

UNIT GROSS WEIGHT kg 21.7 24.8 29.5 33.6 44.0 47.8 51.2
(Without plenum) lb 47.8 54.7 65.0 74.1 97.0 105.4 112.9

UNIT WEIGHT kg 20.0 24.0 28.0 33.0 44.0 47.0 50.0


(With plenum) lb 44.1 52.9 61.7 72.8 97.0 103.6 110.2

UNIT GROSS WEIGHT kg 22.7 28.8 31.5 36.6 47.0 50.8 55.2
(With plenum) lb 50.0 63.5 69.4 80.7 103.6 112.0 121.7
CONDENSATE DRAIN PIPE SIZE R3/4
NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL THE UNITS ARE BEING TESTED UNDER FOLLOWING CONTITION:
• COOLING: 27°C DB/19.5°C WB INDOOR AND WATER INLET 7°C OUTLET 12°C
• HEATING: 21°C DB INDOOR AND WATER 60°C INLET.WATER FLOW:SAME WITH COOLING CONDITION.


MCW-H
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
m3/h 360 510 750 1010 1380 1570 2000
HIGH
CFM 212 300 441 594 812 924 1176
m3/h 250 350 470 770 1070 1100 1470
Air Flow MEDIUM
CFM 147 206 276 453 629 653 865
m /h
3
180 230 330 490 720 820 1010
LOW
CFM 106 135 194 288 424 482 594
EXTERNAL STATIC Pa 0,30,60,80
PRESSURE in.wg 0,0.12,0.24,0.32
W 2130 3100 4260 5980 7580 8570 10380
TOTAL COOLING CAPACITY
Btu/h 7268 10578 14536 20405 25864 29242 35418
SENSIBLE COOLING W 1683 2285 3146 4272 5862 6220 7531
CAPACITY Btu/h 5742 7798 10735 14578 20002 21224 25696
TOTAL HEATING W 1350 2280 3210 4290 5120 6940 8490
CAPACITY (1 ROW) Btu/h 4606 7780 10953 14638 17470 23680 28969
WATER FLOW RATE m3/h 0.4 0.6 0.8 1.1 1.4 1.6 1.9
(3 ROWS) USGPM 1.8 2.5 3.4 4.8 6.1 6.9 8.5
WATER FLOW RATE m3/h 0.12 0.20 0.28 0.37 0.44 0.59 0.73
(1 ROW) USGPM 0.5 0.9 1.2 1.6 1.9 2.6 3.2
HEAD LOSS (COOLING) kPa 14.6 12.0 21.6 38.2 18.4 21 32.7
(3 ROWS) in.wg. 58.4 48.0 86.4 152.8 73.6 84.0 130.8
HEIGHT mm 251 251 251 251 251 251 251
UNIT
DIMENSIONS

DIMEN- WIDTH mm 714 884 1014 1214 1464 1564 1824


SIONS
DEPTH mm 556 556 556 556 556 556 556
HEIGHT mm 260 260 260 260 260 260 260
PACKING
DIMEN- WIDTH mm 724 894 1024 1224 1474 1574 1834
SION
DEPTH mm 570 570 570 570 570 570 570
HEAD LOSS (HEATING) kPa 10.3 18 31.5 14.8 16.9 25.8 9.6
(1 ROW) in.wg. 41 72 126 59 67 103 38
UNIT WEIGHT kg 20.0 24.0 28.0 32.0 44.0 47.0 49.0
(Without plenum) lb 44.1 52.9 61.7 70.5 97.0 103.6 108.0
UNIT GROSS WEIGHT kg 22.7 26.8 31.5 35.6 47.0 50.8 54.2
(Without plenum) lb 50.0 59.1 69.4 78.5 103.6 112.0 119.5
kg 22.0 27.0 31.0 36.0 48.0 52.0 56.0
UNIT WEIGHT (With plenum)
lb 48.5 59.5 68.3 79.4 105.8 114.6 123.5
UNIT GROSS WEIGHT kg 24.7 29.8 34.5 39.6 51.0 55.8 61.2
(With plenum) lb 54.5 65.7 76.1 87.3 112.4 123.0 134.9
CONDENSATE DRAIN PIPE SIZE R3/4

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL THE UNITS ARE BEING TESTED UNDER FOLLOWING CONTITION:
• COOLING: 27°C DB/19.5°C WB INDOOR AND WATER INLET 7°C OUTLET 12°C
• HEATING: 21°C DB INDOOR AND WATER INLET 60°C OUTLET 50°C.


MCW-F
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
m3/h 360 510 750 1010 1380 1570 2000
HIGH
CFM 212 300 441 594 812 924 1176
m3/h 250 350 470 770 1070 1100 1470
Air Flow MEDIUM
CFM 147 206 276 453 629 653 865
m3/h 180 230 330 490 720 820 1010
LOW
CFM 106 135 194 288 424 482 594

EXTERNAL STATIC kPa 0,30,60,80


PRESSURE in.wg 0,0.12,0.24,0.32

TOTAL COOLING W 2622 3418 5277 7185 8691 10261 12791


CAPACITY Btu/h 8948 11661 18007 24517 29653 35013 43644

SENSIBLE COOLING W 1783 2406 3536 5047 6365 7297 9382


CAPACITY Btu/h 6085 8210 12066 17222 21719 24899 32011

TOTAL HEATING W 4196 5468 8444 11496 13905 16418 20465


CAPACITY Btu/h 14317 18658 28811 39227 47445 56020 69830
m3/h 0.5 0.6 0.9 1.3 1.5 1.8 2.3
WATER FLOW RATE
USGPM 2.0 2.7 4.1 5.5 6.8 8.0 10.1
kPa 1.3 6.0 13.0 27.0 8.8 12.0 20.0
HEAD LOSS (COOLING)
in.wg. 5.2 24.1 52.2 108.3 35.3 48.1 80.2

UNIT HEIGHT mm 251 251 251 251 251 251 251


DIMEN- WIDTH mm 714 884 1014 1214 1464 1564 1824
DIMENSIONS

SIONS DEPTH mm 556 556 556 556 556 556 556


HEIGHT mm 260 260 260 260 260 260 260
PACKING
DIMEN- WIDTH mm 724 894 1024 1224 1474 1574 1834
ENSION
DEPTH mm 570 570 570 570 570 570 570

UNIT WEIGHT kg 20.0 24.0 28.0 32.0 44.0 47.0 49.0


(Without plenum) lb 44.1 52.9 61.7 70.5 97.0 103.6 108.0

UNIT GROSS WEIGHT kg 22.7 26.8 31.5 35.6 47.0 50.8 54.2
(Without plenum) lb 50.0 59.1 69.4 78.5 103.6 112.0 119.5

UNIT WEIGHT kg 22.0 27.0 31.0 36.0 48.0 52.0 56.0


(With plenum) lb 48.5 59.5 68.3 79.4 105.8 114.6 123.5

UNIT GROSS WEIGHT kg 24.7 29.8 34.5 39.6 51.0 55.8 61.2
(With plenum) lb 54.5 65.7 76.1 87.3 112.4 123.0 134.9
CONDENSATE DRAIN PIPE SIZE R3/4

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL THE UNITS ARE BEING TESTED UNDER FOLLOWING CONTITION:
• COOLING: 27°C DB/19.5°C WB INDOOR AND WATER INLET 7°C OUTLET 12°C
• HEATING: 21°C DB INDOOR AND WATER 60°C INLET.WATER FLOW:SAME WITH COOLING CONDITION.


Components Data
MCW-C/H/F
MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
TYPE CENTRIFUGAL (BLADE: FORWARD)
QUANTITY 1 2 3 4
FAN
MATERIAL GALVANIZED STEEL
DRIVE DIRECT DRIVE
TYPE SINGLE PHASE CAPACITOR RUNNING
MOTOR QUANTITY 1 2
IP/INSULATION GRADE IP20/E
MATERIAL COPPER
TUBE mm 9.52
DIAMETER
in 3/8
MATERIAL HYDROPHILIC ALUMINUM

THICK- mm 0.11
COIL NESS in 0.0043

FACE m2 0.09 0.13 0.15 0.19 0.24 0.26 0.32


FIN
AREA ft 2
0.98 1.35 1.64 2.07 2.62 2.84 3.41
C 3
ROW
H/F 4
FIN PER INCH 11
TYPE NYLON/ALUMINIUM FRAME
mm 462 632 762 962 1212 1311 1572
LENGTH
AIR in 18.19 24.88 30.00 37.87 47.72 51.61 61.89
FILTER mm 205
(Option) SIZE WIDTH
in 8.07
THICK- mm 8
NESS in 0.31

NOTES:
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.


Sound Data
MCW-C/H/F
ESP 0Pa 30Pa
1/1 Octave Sound pressure level 1/1 Octave Sound pressure level
(dBA, ref 20μPa) Total (dBA, ref 20μPa) Total
Unit Speed
dB (A) dB (A)
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
High 15 19 23 28 28 23 14 13 33 15 19 24 28 29 24 15 13 33
200 Medium 14 18 19 24 24 19 14 13 29 12 17 22 26 26 23 15 13 31
Low 13 14 17 20 18 14 13 13 25 15 18 18 20 20 15 12 13 26
High 16 21 26 32 34 30 19 14 37 16 21 26 32 34 30 19 14 37
300 Medium 15 19 23 28 28 23 14 13 33 12 17 22 26 26 23 15 13 31
Low 15 15 19 23 23 18 11 11 28 14 18 19 24 24 19 14 13 29
High 14 20 25 31 32 28 16 14 36 16 21 28 33 34 31 20 13 38
400 Medium 12 17 22 26 26 23 15 13 31 13 20 26 29 31 27 18 14 35
Low 15 18 18 20 20 15 12 13 26 15 19 24 28 29 24 15 13 33
High 15 25 30 35 37 33 25 18 41 16 28 32 36 39 37 30 21 43
600 Medium 14 24 28 33 35 32 22 16 39 14 24 28 33 35 32 22 16 39
Low 15 19 23 28 28 23 14 13 33 14 18 23 27 28 23 15 13 32
High 14 23 29 34 37 32 21 15 40 15 25 30 35 37 33 25 18 41
800 Medium 16 21 28 33 34 31 20 13 38 16 21 28 33 34 31 20 13 38
Low 14 18 23 27 28 23 15 13 32 15 19 24 28 29 24 15 13 33
High 15 25 30 35 37 33 25 18 41 16 28 32 36 39 37 30 21 43
1000 Medium 16 21 28 33 34 31 20 13 38 16 21 26 32 34 30 19 14 37
Low 15 19 23 28 28 23 14 13 33 14 20 23 28 30 27 16 13 34
High 16 28 32 36 39 37 30 21 43 17 28 32 37 41 38 28 21 44
1200 Medium 14 23 29 34 37 32 21 15 40 14 24 28 33 35 32 22 16 39
Low 13 20 26 29 31 27 18 14 35 15 19 24 28 29 24 15 13 33
ESP 60Pa 80Pa
1/1 Octave Sound pressure level 1/1 Octave Sound pressure level
(dBA, ref 20μPa) Total (dBA, ref 20μPa) Total
Unit Speed
dB(A) dB(A)
63 125 250 500 1k 2k 4k 8k 63 125 250 500 1k 2k 4k 8k
High 16 21 26 32 34 30 19 14 37 16 21 28 33 34 31 20 13 38
200 Medium 14 20 23 28 30 27 16 13 34 13 20 26 29 31 27 18 14 35
Low 12 17 22 26 26 23 15 13 31 14 18 23 27 28 23 15 13 32
High 16 21 28 33 34 31 20 13 38 14 24 28 33 35 32 22 16 39
300 Medium 13 20 26 29 31 27 18 14 35 14 20 25 31 32 28 16 14 36
Low 12 17 22 26 26 23 15 13 31 14 18 23 27 28 23 15 13 32
High 15 25 30 35 37 33 25 18 41 16 30 34 38 42 38 29 22 45
400 Medium 14 20 25 31 32 28 16 14 36 15 25 30 35 37 33 25 18 41
Low 15 19 23 28 28 23 14 13 33 13 20 26 29 31 27 18 14 35
High 19 36 36 41 43 40 30 26 47 19 35 40 43 46 43 34 31 50
600 Medium 17 28 32 37 41 38 28 21 44 18 34 35 40 42 39 31 20 46
Low 16 21 28 33 34 31 20 13 38 18 26 31 36 38 35 27 16 42
High 19 36 36 41 43 40 30 26 47 18 34 39 42 45 43 34 30 49
800 Medium 17 28 32 37 41 38 28 21 44 19 36 36 41 43 40 30 26 47
Low 14 24 28 33 35 32 22 16 39 17 28 32 37 41 38 28 21 44
High 18 34 39 42 45 43 34 30 49 18 34 39 42 45 43 34 30 49
1000 Medium 18 34 35 40 42 39 31 20 46 18 32 38 40 44 42 36 29 48
Low 14 23 29 34 37 32 21 15 40 16 30 34 38 42 38 29 22 45
High 18 34 39 42 45 43 34 30 49 18 34 39 42 45 43 34 30 49
1200 Medium 16 30 34 38 42 38 29 22 45 18 32 38 40 44 42 36 29 48
Low 18 26 31 36 38 35 27 16 42 16 30 34 38 42 38 29 22 45

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) SOUND PRESSURE LEVELS ARE TESTED IN SEMI-ANECHOIC ROOM,WITH BACKGROUND LEVEL: 11.5dB(A),
MICROPHONE POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

10
Performance Data-Cooling
MCW-C
ENTERING AIR: DB27ºC, WB19.5ºC

WATER ENTERING WATER TEMPERATUREºC


W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h) TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 6.60 1981 1646 1848 1589 1728 1537 1604 1485 1489 1437
0.32 10.90 2201 1744 2039 1672 1907 1613 1770 1555 1616 1490
MCW200
0.4 15.92 2337 1806 2199 1743 2026 1666 1881 1603 1730 1537
0.48 21.67 2472 1869 2310 1793 2131 1712 1964 1638 1807 1570
0.36 5.50 3006 2275 2828 2204 2644 2132 2455 2057 2258 1982
0.48 9.34 3306 2399 3111 2318 2865 2218 2659 2137 2446 2054
MCW300
0.6 14.09 3557 2504 3299 2396 3085 2309 2823 2202 2597 2113
0.72 19.76 3707 2569 3464 2466 3217 2363 2966 2259 2710 2157
0.48 9.95 4101 3122 3825 3010 3577 2913 3335 2819 3081 2722
0.64 16.37 4490 3280 4191 3157 3919 3047 3638 2937 3347 2823
MCW400
0.8 24.20 4808 3413 4491 3282 4168 3148 3869 3027 3506 2884
0.96 33.43 5020 3506 4723 3378 4355 3225 3984 3073 3665 2948
0.66 16.76 5805 4255 5462 4122 5064 3968 4701 3831 4324 3689
0.88 27.57 6401 4495 5976 4323 5501 4136 5106 3982 4697 3828
MCW600
1.1 40.78 6798 4657 6349 4474 5850 4273 5430 4110 4921 3914
1.32 56.38 7046 4761 6630 4589 6156 4397 5673 4204 5145 3997
0.84 7.23 7330 5844 6832 5645 6389 5470 5930 5291 5507 5130
1.12 12.85 8022 6125 7548 5929 7058 5734 6551 5534 6027 5330
MCW800
1.4 20.09 8575 6355 8068 6142 7423 5878 6947 5687 6390 5470
1.68 28.93 9059 6563 8459 6308 7849 6053 7229 5802 6650 5572
0.96 9.62 8213 6173 7728 5993 7226 5804 6771 5637 6229 5444
1.28 15.78 9073 6505 8537 6298 7915 6060 7346 5849 6758 5633
MCW1000
1.6 23.22 9777 6784 9126 6523 8396 6244 7794 6015 7170 5786
1.92 31.92 10325 7005 9568 6699 8809 6402 8177 6159 7522 5916
1.14 14.63 9868 7443 9197 7189 8600 6962 8059 6763 7485 6557
1.52 23.86 10902 7843 10081 7524 9427 7276 8750 7022 8050 6763
MCW1200
1.9 34.86 11560 8102 10877 7832 10089 7524 9364 7249 8544 6941
2.28 47.61 12218 8372 11408 8043 10585 7719 9671 7368 8897 7076

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200C MCW300C MCW400C MCW600C MCW800C MCW1000C MCW1200C
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

11
ENTERING AIR: DB28ºC, WB21ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 6.60 2216 1634 2102 1586 1967 1532 1829 1476 1705 1427
0.32 10.90 2488 1751 2342 1688 2193 1625 2025 1555 1888 1500
MCW200
0.4 15.92 2682 1837 2526 1767 2367 1698 2189 1623 2025 1555
0.48 21.67 2818 1898 2655 1824 2471 1744 2287 1665 2132 1599
0.36 5.50 3393 2274 3191 2196 2999 2122 2802 2049 2590 1971
0.48 9.34 3795 2434 3572 2345 3321 2246 3092 2157 2860 2071
MCW300
0.6 14.09 4025 2528 3818 2444 3578 2347 3310 2242 3063 2146
0.72 19.76 4255 2625 3982 2511 3758 2420 3479 2307 3198 2199
0.48 9.95 4626 3117 4311 2994 4069 2904 3785 2797 3497 2691
0.64 16.37 5113 3308 4850 3205 4505 3069 4194 2950 3878 2832
MCW400
0.8 24.20 5519 3475 5158 3328 4796 3183 4501 3067 4133 2926
0.96 33.43 5762 3576 5427 3438 5050 3284 4706 3148 4355 3012
0.66 16.76 6550 4255 6159 4107 5763 3959 5361 3814 4997 3683
0.88 27.57 7290 4542 6807 4352 6374 4187 5935 4024 5488 3858
MCW600
1.1 40.78 7746 4723 7239 4521 6833 4361 6318 4166 5890 4006
1.32 56.38 8088 4862 7618 4672 7139 4483 6605 4276 6157 4107
0.84 7.23 8216 5793 7680 5589 7249 5428 6737 5236 6280 5070
1.12 12.85 9129 6155 8583 5938 8031 5725 7537 5538 6902 5300
MCW800
1.4 20.09 9843 6444 9336 6236 8671 5972 8138 5764 7462 5508
1.68 28.93 10319 6640 9788 6419 9168 6168 8538 5921 7835 5649
0.96 9.62 9248 6137 8687 5934 8200 5763 7620 5561 7104 5381
1.28 15.78 10415 6573 9709 6307 9164 6110 8450 5853 7842 5637
MCW1000
1.6 23.22 11134 6847 10475 6595 9808 6343 9129 6096 8440 5849
1.92 31.92 11672 7059 10986 6789 10290 6523 9582 6262 8862 5997
1.14 14.63 11004 7362 10438 7157 9659 6876 9066 6671 8451 6455
1.52 23.86 12299 7848 11563 7567 10818 7297 10063 7022 9296 6752
MCW1200
1.9 34.86 13270 8221 12484 7919 11688 7616 10879 7319 9972 6989
2.28 47.61 13917 8475 13098 8151 12267 7832 11423 7519 10479 7173

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200C MCW300C MCW400C MCW600C MCW800C MCW1000C MCW1200C
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

12
ENTERING AIR: DB25ºC, WB18ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 6.60 1737 1526 1618 1472 1495 1417 1379 1367 1267 1320
0.32 10.90 1912 1606 1767 1540 1633 1479 1505 1422 1360 1359
MCW200
0.4 15.92 2043 1668 1890 1596 1733 1525 1586 1458 1443 1395
0.48 21.67 2131 1710 1957 1627 1809 1558 1655 1489 1495 1419
0.36 5.50 2634 2108 2453 2033 2266 1957 2073 1879 1920 1819
0.48 9.34 2893 2218 2674 2126 2452 2033 2243 1947 2058 1873
MCW300
0.6 14.09 3087 2304 2835 2194 2619 2102 2379 2003 2150 1909
0.72 19.76 3238 2371 2976 2254 2712 2141 2498 2052 2258 1954
0.48 9.95 3595 2893 3349 2790 3094 2687 2831 2582 2601 2489
0.64 16.37 3930 3036 3633 2909 3356 2794 3071 2678 2796 2566
MCW400
0.8 24.20 4205 3154 3860 3005 3566 2880 3238 2746 2948 2628
0.96 33.43 4357 3220 4030 3078 3697 2935 3358 2794 3035 2663
0.66 16.76 5089 3944 4740 3802 4343 3645 4040 3526 3681 3387
0.88 27.57 5559 4139 5138 3965 4711 3790 4310 3630 3925 3482
MCW600
1.1 40.78 5901 4284 5417 4080 5005 3908 4545 3725 4138 3562
1.32 56.38 6158 4394 5656 4181 5226 4000 4714 3793 4259 3612
0.84 7.23 6437 5423 5995 5240 5539 5053 5115 4883 4234 4149
1.12 12.85 7033 5674 6551 5470 6001 5245 5537 5053 5088 4875
MCW800
1.4 20.09 7509 5883 6939 5636 6411 5415 5818 5168 5343 4977
1.68 28.93 7867 6040 7328 5802 6668 5521 6100 5283 5555 5062
0.96 9.62 7281 5759 6782 5561 6266 5363 5785 5183 4783 4687
1.28 15.78 7955 6029 7347 5786 6846 5588 6263 5363 5708 5151
MCW1000
1.6 23.22 8494 6249 7786 5961 7252 5745 6635 5507 5947 5241
1.92 31.92 8899 6415 8226 6137 7542 5862 6900 5610 6235 5354
1.14 14.63 8586 6876 7998 6644 7459 6439 6888 6217 5963 5844
1.52 23.86 9477 7233 8752 6941 8086 6682 7462 6439 6800 6185
MCW1200
1.9 34.86 10044 7465 9356 7184 8574 6871 7844 6584 7146 6314
2.28 47.61 10611 7702 9733 7341 8993 7038 8163 6709 7376 6406

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200C MCW300C MCW400C MCW600C MCW800C MCW1000C MCW1200C
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

13
MCW-H
ENTERING AIR: DB27ºC, WB19.5ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 5.95 2007 1628 1880 1575 1758 1525 1632 1475 1514 1428
0.32 9.82 2224 1720 2076 1657 1926 1594 1788 1538 1645 1479
MCW200
0.4 14.34 2398 1796 2224 1720 2079 1658 1916 1590 1762 1527
0.48 19.52 2502 1842 2354 1777 2202 1710 2015 1631 1854 1564
0.36 10.60 2962 2225 2765 2146 2585 2073 2380 1994 2190 1920
0.48 18.00 3249 2345 3034 2256 2817 2167 2614 2086 2405 2003
MCW300
0.6 27.16 3464 2437 3237 2340 3027 2253 2770 2147 2513 2046
0.72 38.08 3631 2509 3372 2397 3132 2296 2887 2195 2656 2103
0.48 18.46 4017 3044 3747 2937 3504 2841 3252 2743 3018 2653
0.64 30.36 4429 3215 4135 3093 3836 2972 3561 2863 3250 2743
MCW400
0.8 44.87 4703 3330 4393 3200 4108 3083 3757 2942 3456 2822
0.96 61.98 4944 3433 4619 3294 4259 3144 3953 3019 3585 2873
0.66 8.49 5605 4118 5274 3987 4890 3838 4539 3702 4176 3568
0.88 13.97 6170 4348 5761 4180 5346 4015 4924 3850 4530 3699
MCW600
1.1 20.66 6547 4505 6116 4325 5677 4146 5231 3969 4813 3807
1.32 28.57 6877 4644 6382 4436 5885 4231 5462 4061 4954 3861
0.84 8.77 7132 5673 6648 5476 6217 5308 5825 5152 5358 4975
1.12 15.59 7792 5943 7332 5755 6856 5562 6310 5345 5805 5148
MCW800
1.4 24.36 8453 6222 7829 5960 7321 5751 6687 5492 6152 5283
1.68 35.08 8849 6395 8202 6116 7669 5894 7011 5623 6450 5398
0.96 15.69 8062 6021 7585 5843 7027 5631 6584 5470 6057 5279
1.28 25.75 8883 6342 8288 6108 7750 5904 7133 5670 6505 5440
MCW1000
1.6 37.88 9480 6580 8850 6329 8210 6077 7559 5830 6954 5604
1.92 52.07 9928 6763 9271 6498 8604 6233 7925 5969 7235 5709
1.14 5.63 9431 7156 8874 6938 8298 6721 7702 6498 7152 6302
1.52 9.18 10409 7539 9711 7265 9002 6990 8429 6773 7754 6519
MCW1200
1.9 13.41 11032 7788 10380 7529 9628 7228 8937 6964 8222 6695
2.28 18.31 11655 8041 10883 7725 10098 7415 9301 7104 8489 6793

NOTES:
1) TTHE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200H MCW300H MCW400H MCW600H MCW800H MCW1000H MCW1200H
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

14
ENTERING AIR: DB28ºC, WB21ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 5.95 2254 1618 2128 1568 2000 1518 1860 1464 1727 1413
0.32 9.82 2533 1733 2384 1671 2214 1603 2078 1548 1914 1485
MCW200
0.4 14.34 2713 1808 2573 1750 2393 1675 2246 1615 2063 1542
0.48 19.52 2872 1877 2687 1798 2536 1734 2363 1663 2188 1591
0.36 10.60 3318 2218 3121 2139 2946 2073 2719 1987 2535 1918
0.48 18.00 3702 2371 3485 2284 3265 2196 3042 2109 2814 2023
MCW300
0.6 27.16 3949 2474 3693 2368 3486 2284 3249 2190 3007 2096
0.72 38.08 4141 2555 3902 2454 3658 2353 3410 2253 3136 2146
0.48 18.46 4493 3027 4261 2937 3952 2820 3709 2730 3458 2639
0.64 30.36 5044 3245 4747 3125 4410 2995 4139 2890 3797 2762
MCW400
0.8 44.87 5360 3373 5084 3260 4763 3132 4404 2993 4075 2867
0.96 61.98 5635 3488 5308 3352 4940 3202 4636 3083 4260 2937
0.66 8.49 6380 4140 5949 3975 5567 3833 5225 3707 4828 3562
0.88 13.97 7029 4394 6616 4231 6196 4069 5724 3890 5336 3747
MCW600
1.1 20.66 7515 4593 7026 4394 6583 4220 6179 4063 5675 3873
1.32 28.57 7785 4704 7385 4539 6874 4334 6406 4149 5929 3967
0.84 8.77 7959 5615 7478 5431 7058 5271 6561 5086 6086 4910
1.12 15.59 8945 6005 8340 5767 7873 5582 7262 5349 6769 5164
MCW800
1.4 24.36 9627 6284 8988 6025 8416 5796 7835 5566 7244 5340
1.68 35.08 10082 6477 9491 6231 8891 5984 8281 5742 7601 5476
0.96 15.69 8997 5965 8453 5765 7978 5596 7416 5396 6913 5223
1.28 25.75 10111 6381 9509 6155 8822 5899 8280 5704 7652 5479
MCW1000
1.6 37.88 10796 6646 10241 6433 9513 6155 8784 5886 8189 5670
1.92 52.07 11310 6849 10728 6620 9973 6329 9360 6099 8592 5817
1.14 5.63 10621 7120 9978 6881 9372 6664 8754 6441 8160 6234
1.52 9.18 11847 7580 11140 7311 10424 7047 9612 6747 8960 6514
MCW1200
1.9 13.41 12664 7901 11915 7606 11155 7316 10470 7063 9600 6742
2.28 18.31 13379 8181 12593 7870 11704 7529 10985 7254 10080 6918

NOTES:
1) TTHE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED
MUST MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200H MCW300H MCW400H MCW600H MCW800H MCW1000H MCW1200H
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

15
ENTERING AIR: DB25ºC, WB18ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.24 5.95 1760 1510 1632 1455 1521 1407 1403 1358 1279 1306
0.32 9.82 1947 1592 1813 1533 1663 1468 1521 1408 1385 1351
MCW200
0.4 14.34 2067 1646 1925 1582 1779 1518 1604 1442 1470 1386
0.48 19.52 2186 1701 2009 1619 1856 1552 1686 1478 1534 1413
0.36 10.60 2594 2061 2397 1978 2215 1903 2042 1832 1860 1760
0.48 18.00 2821 2159 2627 2075 2410 1984 2205 1898 2007 1819
MCW300
0.6 27.16 3006 2241 2781 2141 2551 2043 2334 1952 2109 1860
0.72 38.08 3129 2294 2915 2199 2658 2089 2399 1980 2183 1889
0.48 18.46 3521 2822 3280 2722 3030 2619 2795 2525 2547 2427
0.64 30.36 3847 2961 3555 2837 3285 2724 3028 2619 2779 2519
MCW400
0.8 44.87 4083 3063 3776 2931 3489 2809 3168 2677 2863 2553
0.96 61.98 4261 3140 3969 3012 3616 2863 3308 2735 2989 2604
0.66 8.49 4912 3816 4575 3676 4262 3551 3899 3406 3523 3260
0.88 13.97 5358 4004 4991 3847 4576 3679 4187 3520 3812 3374
MCW600
1.1 20.66 5683 4140 5294 3975 4821 3779 4410 3611 3986 3440
1.32 28.57 5927 4246 5483 4055 4996 3850 4570 3676 4101 3485
0.84 8.77 6260 5263 5831 5086 5388 4902 4974 4733 4154 4071
1.12 15.59 6830 5509 6361 5308 5878 5103 5377 4897 4899 4705
MCW800
1.4 24.36 7285 5705 6786 5488 6220 5246 5691 5025 5183 4820
1.68 35.08 7683 5882 7104 5628 6514 5373 5915 5119 5345 4885
0.96 15.69 7077 5587 6562 5388 6090 5201 5572 5006 4725 4631
1.28 25.75 7720 5847 7131 5609 6644 5418 6078 5197 5538 4993
MCW1000
1.6 37.88 8235 6060 7610 5804 6976 5548 6382 5314 5813 5097
1.92 52.07 8621 6220 7910 5925 7308 5683 6686 5435 6042 5184
1.14 5.63 8281 6638 7714 6415 7127 6182 6641 5996 5903 5785
1.52 9.18 9048 6954 8428 6700 7787 6441 7124 6182 6546 5960
MCW1200
1.9 13.41 9662 7208 8928 6902 8249 6628 7486 6322 6874 6084
2.28 18.31 10122 7399 9428 7109 8579 6762 7848 6467 7147 6193

NOTES:
1) TTHE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED
MUST MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200H MCW300H MCW400H MCW600H MCW800H MCW1000H MCW1200H
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

16
MCW-F
ENTERING AIR: DB27ºC, WB19.5ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.3 1.00 2526 1743 2377 1684 2207 1618 2035 1552 1872 1492
0.4 1.05 2751 1834 2604 1774 2405 1695 2204 1616 2028 1550
MCW200
0.5 1.58 2941 1913 2735 1827 2527 1743 2345 1672 2145 1595
0.6 2.21 3045 1957 2865 1881 2648 1793 2444 1711 2236 1629
0.36 2.55 3130 2286 2903 2195 2714 2121 2538 2053 2335 1975
0.48 4.21 3448 2417 3201 2316 2994 2232 2779 2146 2539 2053
MCW300
0.6 6.26 3675 2514 3415 2403 3213 2321 2946 2212 2693 2112
0.72 8.69 3856 2591 3586 2475 3353 2378 3075 2265 2812 2159
0.54 5.22 4890 3389 4601 3278 4271 3154 3994 3053 3674 2935
0.72 8.66 5394 3587 5075 3460 4714 3322 4317 3172 3998 3053
MCW400
0.9 12.88 5717 3718 5380 3582 4967 3419 4581 3271 4215 3133
1.08 17.88 5969 3822 5616 3677 5220 3518 4787 3350 4350 3184
0.78 12.05 6779 4877 6334 4693 5881 4510 5459 4342 5057 4188
1.04 19.99 7400 5138 6918 4935 6427 4732 5926 4529 5452 4342
MCW600
1.3 29.74 7782 5305 7277 5086 6805 4887 6238 4655 5739 4455
1.56 41.30 8116 5450 7592 5222 7057 4993 6472 4751 5954 4539
0.9 3.49 7953 6065 7484 5881 6941 5666 6496 5498 5976 5300
1.2 5.96 8787 6405 8208 6169 7675 5954 7124 5739 6554 5520
MCW800
1.5 8.91 9365 6646 8751 6392 8127 6139 7543 5902 6939 5666
1.8 12.34 9878 6865 9234 6594 8578 6319 7910 6048 7229 5777
1.08 4.99 9540 7012 8976 6791 8394 6565 7730 6314 7168 6108
1.44 8.35 10524 7400 9831 7125 9193 6874 8533 6619 7850 6364
MCW1000
1.8 12.51 11282 7714 10473 7380 9726 7080 9028 6810 8305 6535
2.16 17.47 11812 7935 11042 7611 10193 7267 9399 6953 8590 6643
1.38 8.71 11915 9016 11211 8729 10484 8436 9731 8143 8952 7837
1.84 14.57 13032 9478 12263 9160 11385 8798 10492 8442 9722 8137
MCW1200
2.3 21.81 13963 9877 12963 9453 12122 9097 11176 8711 10211 8330
2.76 30.44 14522 10121 13664 9753 12613 9303 11556 8867 10631 8492

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200F MCW300F MCW400F MCW600F MCW800F MCW1000F MCW1200F
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

17
ENTERING AIR: DB28ºC, WB21ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.3 1.00 2840 1746 2675 1683 2507 1620 2336 1558 2178 1501
0.4 1.05 3138 1863 2957 1791 2774 1721 2570 1644 2396 1580
MCW200
0.5 1.58 3336 1943 3164 1874 2951 1789 2753 1713 2536 1631
0.6 2.21 3475 2001 3277 1919 3058 1832 2887 1764 2660 1677
0.36 2.55 3489 2272 3260 2185 3077 2115 2888 2045 2692 1974
0.48 4.21 3906 2439 3655 2338 3450 2258 3194 2159 2978 2078
MCW300
0.6 6.26 4166 2546 3952 2458 3707 2358 3435 2252 3182 2154
0.72 8.69 4426 2655 4149 2539 3870 2423 3610 2321 3345 2216
0.54 5.22 5531 3400 5207 3281 4878 3161 4544 3041 4236 2935
0.72 8.66 6109 3619 5755 3483 5396 3350 5029 3216 4656 3083
MCW400
0.9 12.88 6563 3796 6147 3633 5765 3488 5411 3354 4979 3198
1.08 17.88 6852 3914 6460 3757 6024 3587 5619 3433 5206 3281
0.78 12.05 7672 4906 7225 4729 6771 4552 6309 4374 5838 4197
1.04 19.99 8439 5218 7953 5019 7409 4800 6908 4603 6353 4391
MCW600
1.3 29.74 8933 5428 8421 5212 7851 4977 7322 4764 6783 4555
1.56 41.30 9316 5592 8785 5367 8194 5119 7644 4893 7040 4655
0.9 3.49 8909 6031 8380 5829 7878 5640 7301 5425 6863 5266
1.2 5.96 9940 6435 9358 6203 8702 5949 8167 5747 7613 5541
MCW800
1.5 8.91 10749 6762 10057 6482 9493 6255 8785 5984 8075 5713
1.8 12.34 11265 6977 10615 6706 9954 6439 9219 6147 8536 5885
1.08 4.99 10777 7007 10140 6766 9494 6531 8837 6295 8238 6079
1.44 8.35 11994 7473 11212 7174 10505 6904 9787 6639 9123 6398
MCW1000
1.8 12.51 12863 7822 12036 7493 11206 7169 10517 6909 9668 6594
2.16 17.47 13385 8033 12613 7719 11828 7409 11101 7130 10144 6771
1.38 8.71 13357 8979 12568 8673 11863 8399 11134 8124 10212 7781
1.84 14.57 14853 9584 13987 9228 13107 8879 12122 8498 11300 8186
MCW1200
2.3 21.81 15815 9983 14899 9603 13968 9222 13020 8848 11970 8442
2.76 30.44 16670 10345 15609 9896 14734 9534 13649 9097 12640 8698

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200F MCW300F MCW400F MCW600F MCW800F MCW1000F MCW1200F
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

18
ENTERING AIR: DB25ºC, WB18ºC
ENTERING WATER TEMPERATUREºC
WATER
W.P.D
MODEL FLOW 6 7 8 9 10
(kPa)
(m³/h)
TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE TOTAL SENSIBLE
W W W W W W W W W W
0.3 1.00 2207 1611 2041 1543 1899 1486 1737 1423 1591 1367
0.4 1.05 2400 1691 2222 1616 2053 1547 1878 1477 1697 1407
MCW200
0.5 1.58 2535 1749 2361 1674 2156 1589 1972 1515 1782 1440
0.6 2.21 2639 1794 2430 1704 2258 1631 2043 1543 1856 1469
0.36 2.55 2737 2115 2549 2037 2355 1958 2170 1883 1989 1812
0.48 4.21 2991 2223 2768 2128 2557 2040 2355 1958 2142 1872
MCW300
0.6 6.26 3187 2308 2950 2205 2726 2111 2478 2008 2253 1916
0.72 8.69 3343 2377 3096 2268 2827 2153 2586 2051 2337 1950
0.54 5.22 4277 3136 3984 3020 3707 2912 3392 2790 3109 2684
0.72 8.66 4711 3311 4330 3156 4001 3025 3684 2903 3351 2776
MCW400
0.9 12.88 4959 3414 4619 3274 4214 3110 3855 2970 3484 2827
1.08 17.88 5206 3518 4792 3345 4374 3175 4002 3027 3616 2878
0.78 12.05 5925 4507 5519 4333 5064 4146 4665 3981 4274 3824
1.04 19.99 6419 4722 5940 4513 5489 4323 4989 4114 4537 3930
MCW600
1.3 29.74 6789 4887 6247 4645 5736 4426 5248 4220 4772 4027
1.56 41.30 6995 4977 6515 4764 5949 4516 5442 4300 4918 4085
0.9 3.49 6965 5623 6488 5425 5994 5223 5571 5055 5113 4875
1.2 5.96 7684 5924 7106 5679 6565 5455 6006 5232 5506 5029
MCW800
1.5 8.91 8181 6139 7569 5876 6993 5631 6398 5386 5821 5154
1.8 12.34 8568 6306 7930 6031 7326 5773 6659 5494 6057 5249
1.08 4.99 8353 6491 7780 6260 7245 6049 6628 5809 6128 5617
1.44 8.35 9201 6840 8510 6555 7862 6295 7193 6030 6593 5794
MCW1000
1.8 12.51 9788 7090 8996 6756 8368 6501 7604 6192 6871 5902
2.16 17.47 10180 7257 9421 6933 8649 6614 7912 6314 7150 6010
1.38 8.71 10510 8380 9715 8043 8976 7737 8212 7425 7535 7157
1.84 14.57 11393 8760 10612 8424 9735 8055 8906 7712 8105 7388
MCW1200
2.3 21.81 12034 9041 11210 8679 10219 8255 9412 7918 8562 7569
2.76 30.44 12516 9260 11658 8879 10702 8461 9854 8105 8790 7662

NOTES:
1) THE COOLING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

TOTAL: TOTAL COOLING CAPACITY SENSIBLE:SENSIBLE COOLING CAPACITY

Cooling Capacity Correction Factors:


MODEL MCW200F MCW300F MCW400F MCW600F MCW800F MCW1000F MCW1200F
TOTAL 0.85 0.82 0.84 0.84 0.87 0.85 0.86
MEDIUM
SENSIBLE 0.78 0.75 0.78 0.80 0.80 0.80 0.80
TOTAL 0.66 0.60 0.65 0.65 0.68 0.70 0.71
LOW
SENSIBLE 0.58 0.55 0.58 0.60 0.62 0.63 0.66

19
Performance Data-Heating
MCW-C
ENTERING AIR: DB21ºC
WATER ENTERING WATER TEMPERATUREºC
W.P.D
MODEL FLOW
(kPa) 40 45 50 55 60 65 70
(m³/h)
W W W W W W W
0.24 5.28 1571 1996 2426 2845 3263 3681 4124
0.32 8.72 1646 2092 2542 2980 3418 3857 4295
MCW200
0.4 12.74 1703 2151 2600 3048 3515 3966 4441
0.48 17.34 1732 2199 2657 3116 3574 4032 4490
0.36 4.40 2318 2945 3559 4173 4786 5432 6084
0.48 7.47 2414 3067 3726 4369 5011 5654 6296
MCW300
0.6 11.28 2496 3153 3810 4467 5124 5813 6509
0.72 15.81 2524 3205 3894 4565 5237 5908 6579
0.48 7.96 3333 4236 5118 6000 6883 7765 8700
0.64 13.10 3476 4391 5337 6293 7219 8144 9070
MCW400
0.8 19.36 3558 4546 5493 6440 7387 8334 9280
0.96 26.75 3639 4597 5555 6513 7512 8523 9491
0.66 13.41 4518 5707 6896 8135 9389 10592 11796
0.88 22.06 4713 5989 7237 8484 9732 10980 12227
MCW600
1.1 32.63 4853 6130 7407 8684 9961 11238 12515
1.32 45.12 4909 6200 7492 8784 10133 11496 12803
0.84 5.79 5874 7468 9024 10580 12136 13780 15445
1.12 10.28 6143 7856 9493 11129 12766 14403 16138
MCW800
1.4 16.07 6373 8050 9727 11404 13160 14936 16633
1.68 23.15 6488 8244 9961 11679 13396 15114 16831
0.96 7.70 6674 8430 10253 12099 13879 15658 17437
1.28 12.63 7025 8873 10722 12571 14509 16471 18343
MCW1000
1.6 18.58 7200 9095 11057 13042 14960 16878 18796
1.92 25.54 7376 9317 11258 13199 15140 17183 19249
1.14 11.71 8597 10932 13209 15589 17881 20174 22466
1.52 19.09 9055 11438 13821 16307 18705 21236 23649
MCW1200
1.9 27.89 9285 11800 14346 16820 19293 21767 24240
2.28 38.10 9514 12018 14521 17025 19528 22165 24831

NOTES:
1) THE HEATING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

Heating Capacity Correction Factors:


MODEL MCW200C MCW300C MCW400C MCW600C MCW800C MCW1000C MCW1200C
MEDIUM 0.80 0.78 0.78 0.81 0.83 0.80 0.81
LOW 0.58 0.56 0.57 0.58 0.62 0.60 0.61

20
MCW-H
ENTERING AIR: DB21ºC
WATER ENTERING WATER TEMPERATUREºC
W.P.D
MODEL FLOW
(kPa) 40 45 50 55 60 65 70
(m³/h)
W W W W W W W
0.07 2.58 535 676 828 971 1114 1274 1419
0.10 7.08 596 753 921 1080 1239 1416 1576
MCW200
0.12 10.31 627 791 956 1135 1302 1469 1635
0.14 13.72 642 820 991 1176 1349 1522 1695
0.12 7.13 971 1243 1502 1761 2020 2308 2570
0.16 12.23 1048 1324 1619 1898 2177 2456 2735
MCW300
0.20 17.97 1099 1388 1677 1989 2282 2574 2867
0.24 24.35 1137 1437 1736 2058 2361 2663 2966
0.17 12.63 1389 1767 2150 2521 2891 3262 3633
0.22 20.65 1486 1877 2268 2693 3089 3485 3881
MCW400
0.28 31.49 1563 1974 2385 2797 3248 3664 4080
0.34 43.67 1602 2047 2474 2900 3327 3753 4180
0.22 7.49 1857 2379 2874 3370 3865 4361 4856
0.30 11.25 2014 2544 3074 3604 4134 4724 5261
MCW600
0.37 14.84 2092 2643 3193 3744 4295 4845 5463
0.44 18.72 2145 2709 3273 3838 4402 5027 5598
0.26 6.84 2117 2694 3256 3817 4378 4977 5585
0.35 11.44 2297 2901 3506 4169 4782 5395 6008
MCW800
0.44 16.88 2428 3067 3706 4345 4984 5699 6347
0.53 23.14 2494 3150 3857 4521 5186 5851 6601
0.35 10.97 3063 3869 4710 5562 6380 7198 8016
0.47 17.78 3291 4157 5023 5971 6850 7728 8606
MCW1000
0.59 25.81 3428 4331 5303 6217 7131 8045 8959
0.71 35.07 3520 4504 5442 6380 7319 8257 9195
0.44 4.00 3716 4729 5714 6700 7685 8670 9727
0.58 6.46 3967 5011 6055 7099 8258 9317 10376
MCW1200
0.73 9.65 4135 5223 6311 7399 8602 9705 10808
0.88 13.43 4247 5364 6482 7699 8832 9964 11096

NOTES:
1) THE HEATING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

Heating Capacity Correction Factors:


MODEL MCW200H MCW300H MCW400H MCW600H MCW800H MCW1000H MCW1200H
MEDIUM 0.80 0.78 0.78 0.81 0.83 0.80 0.81
LOW 0.58 0.56 0.57 0.58 0.62 0.60 0.61

21
MCW-F
ENTERING AIR: DB21ºC
WATER ENTERING WATER TEMPERATUREºC
W.P.D
MODEL FLOW
(kPa) 40 45 50 55 60 65 70
(m³/h)
W W W W W W W
0.3 1.00 1936 2458 2970 3483 4015 4552 5070
0.4 1.00 2005 2533 3075 3623 4156 4689 5222
MCW200
0.5 1.26 2044 2595 3150 3694 4237 4780 5323
0.6 1.77 2084 2632 3180 3729 4277 4848 5399
0.36 2.04 2483 3136 3790 4466 5150 5810 6470
0.48 3.37 2586 3267 3968 4652 5362 6050 6737
MCW300
0.6 5.01 2651 3365 4066 4767 5468 6169 6904
0.72 6.95 2690 3398 4125 4860 5575 6289 7004
0.54 4.18 3849 4861 5874 6924 7942 9007 10031
0.72 6.93 3992 5068 6124 7180 8236 9339 10400
MCW400
0.9 10.31 4094 5172 6249 7327 8446 9529 10664
1.08 14.31 4156 5249 6374 7473 8572 9671 10770
0.78 9.64 5321 6721 8122 9522 10980 12388 13867
1.04 15.99 5489 6934 8421 9873 11382 12842 14301
MCW600
1.3 23.79 5601 7075 8549 10073 11555 13101 14590
1.56 33.04 5685 7181 8720 10224 11727 13231 14734
0.9 2.79 6243 7930 9582 11234 12959 14702 16373
1.2 4.77 6560 8287 10013 11802 13610 15355 17100
MCW800
1.5 7.13 6737 8554 10336 12118 13900 15682 17555
1.8 9.88 6842 8643 10497 12370 14190 16009 17828
1.08 3.99 7416 9367 11382 13419 15393 17366 19340
1.44 6.68 7749 9788 11827 13941 16077 18138 20199
MCW1000
1.8 10.01 7916 10051 12209 14314 16419 18524 20629
2.16 13.98 8082 10209 12336 14538 16761 18910 21059
1.38 6.97 9341 11800 14258 16810 19390 21876 24362
1.84 11.66 9761 12330 14899 17467 20036 22726 25309
MCW1200
2.3 17.45 9971 12595 15219 17843 20575 23334 25986
2.76 24.35 10129 12860 15539 18219 20898 23577 26256

NOTES:
1) THE HEATING CAPACITY IS TESTED UNDER HIGH SPEED.THE CAPACITY UNDER MEDIUM AND LOW FAN SPEED MUST
MULTIPLY A CORRECTION FACTOR.
2) W.P.D:WATER PRESSURE DROP

Heating Capacity Correction Factors:


MODEL MCW200F MCW300F MCW400F MCW600F MCW800F MCW1000F MCW1200F
MEDIUM 0.80 0.78 0.78 0.81 0.83 0.80 0.81
LOW 0.58 0.56 0.57 0.58 0.62 0.60 0.61

22
Air Flow vs ESP Curve
1-0Pa 2-30Pa 3-60Pa 4-80Pa
MCW200 MCW300

600 900
3
500 4 800
2

Air Flow, m /h
Air Flow, m /h

400 700

3
3

1 3 4
2
300 600

200 500 1

100 400

0 300
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90

ESP, Pa ESP, Pa

MCW400 MCW600

1000 1800

900 2 3 4 1600
Air Flow, m /h

Air Flow, m /h

800 1400
3

1 2 3 4
700 1200
1
600 1000

500 800

400 600
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90

ESP, Pa ESP, Pa

MCW800 MCW1000

2000
2400
1800 3 4 2200
2
Air Flow, m /h

1600
Air Flow, m /h

2000
3

2 3 4
1
1400 1800
1200 1600
1
1000 1400
800 1200
0 10 20 30 40 50 60 70 80 90 0 10 20 30 40 50 60 70 80 90

ESP, Pa ESP, Pa

23
MCW1200

2600

2400 3 4
2
2200
Air Flow, m /h
3

2000
1
1800

1600

1400
0 10 20 30 40 50 60 70 80 90

ESP, Pa

NOTES:
THE AIR FLOW IS TESTED UNDER HIGH SPEED.

Operating Limits
Operating Limits MCW-C/H/F
Water Circuit
Max. Water side pressure 1.6MPa
Min. Entering water temperature 3ºC (cooling)
Max. Entering water temperature 70ºC (heating)
Power supply
Operating voltage limits ±10% Volt
Operating frequency limits ±2Hz

24
Water Flow Rate vs Pressure Drop Chart
MCW-C

3 Rows Coil Unit Water Pressure Drop Curve

70

60
MCW600
Water Pressure Drop, kPa

50
MCW400
MCW800
40
MCW200
MCW1200
30

20

10
MCW300
MCW1000
0
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2

MCW-H

1 Row Coil System Unit Water Pressure Drop Curve

70

MCW200
60
Water Pressure Drop, kPa

50 MCW300

40 MCW400
MCW1200
30
MCW600
20
MCW800
10
MCW1000
0
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

25
MCW-F

26
Outlines and Dimensions
MCW-C
Without Plenum

D A
100mm Number
UNIT SIZE
Standard B C D E F
extension of Fans
drain pan
drain pan
MCW200C 714 814 448 487 505 507 467 1
MCW300C 884 984 618 657 675 677 637 1
MOUNTING HOLE
MCW400C 1014 1114 748 787 805 807 767 2
4-10*16 MCW600C 1214 1314 948 987 1005 1007 967 2
59

MCW800C 1464 1564 1198 1237 1255 1257 1217 3


MCW1000C 1564 1664 1298 1337 1355 1357 1317 3
MCW1200C 1824 1924 1558 1597 1615 1617 1577 4
187

CONDENSATE DRAIN
R 3/4

AIR VENT
38

B
47 C 63
A
490

30 235

148
WATER RETURN TERMINAL BLOCK

32
CONNECTION Rc3/4
26

WATER OUTLET

120
CAUTION
143

BE CAREFUL NOT TO DAMAGE THE


CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
248

251
WATER INLET

WATER SUPPLY
CONNECTION Rc3/4

35 242

With Plenum

DOWN RETUREN PLEUNM


537
30 235
148
32
556

Model: Air Flow:

Serial No.: Cooling Capacity:

Volt/Phase/Hz: Heating Capacity:

WATER OUTLET
Input Watt: External Static Pressure:

Input Amp.:
120

CAUTION
BE CAREFUL NOT TO DAMAGE THE
CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
247
251

MODEL: FTHC1H(02,03,04,06)AD(00,70)(A,B)00AF20AZ(A,B)1
267

WIRING
FAN SPEED
ORANGE BLACK
SWITCH LF
L BROWN
MF M~
M YELLOW BLACK
HF

WATER INLET H
SHF
RED G/Y

L
BLACK
POWER WHITE BLUE
SOURCE G/Y
N
MAIN SWITCH
G
G/Y
187

NOTE:
FIELD WIRING
M~: FAN MOTOR MF: FAN SPEED MEDIUM
G/Y: GREEN/YELLOW HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

DWG. No.: M08024067435

USE COPPER SUPPLY WIRES


ULTILISER FILS ELECTRIQUES EN CUIVRE

242 206 20
54

RETURN AIR

BACK RETURN PLENUM


556
30 235
148
20
32
26

Model: Air Flow:

Serial No.: Cooling Capacity:

Volt/Phase/Hz: Heating Capacity:

WATER OUTLET Input Watt: External Static Pressure:

Input Amp.:
120

CAUTION
143

BE CAREFUL NOT TO DAMAGE THE


CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
248

206

RETURN AIR
251

MODEL: FTHC1H(02,03,04,06)AD(00,70)(A,B)00AF20AZ(A,B)1

WIRING
FAN SPEED
ORANGE BLACK
SWITCH LF
L BROWN
MF M~
M YELLOW BLACK

WATER INLET
HF
H RED G/Y
SHF
L
BLACK
POWER WHITE BLUE
SOURCE G/Y
N
MAIN SWITCH
G
G/Y

NOTE:
FIELD WIRING
M~: FAN MOTOR MF: FAN SPEED MEDIUM
G/Y: GREEN/YELLOW HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

DWG. No.: M08024067435

USE COPPER SUPPLY WIRES


ULTILISER FILS ELECTRIQUES EN CUIVRE
20

35 242

27
MCW-H
Without Plenum

A A
UNIT B C D Number of
Standard100mm
100mm Number
UNIT SIZE Standard
Drain pan
extension B C D E F
Fans
extension
Drain pan of Fans
drain pan
MCW200H drain pan
714 814 448 487 505 1

MCW200H
MCW300H 714 884 814 984 448618 487 657505 507 467
675 1
1
MCW300H
MCW400H 884 1014 984 1114 618748 657 787675 677 637
805 2 1
Mounting Hole MCW400H
MCW600H 1014 1214 11141314 748948 787 987805 807
1005 767
2 2
4-10*16 MCW600H
MCW800H 1214 1464 13141564 9481198 987 12371005 1007 967 2
59

1255 3
MCW800H
MCW1000H
1464 1564 15641664 11981298 1237 13371255 1257
1355
1217
3
3
MCW1000H
MCW1200H
1564 1664 1298 1337 1355 1357 1317 3
1824 1924 1558 1597 1615 4
MCW1200H 1824 1924 1558 1597 1615 1617 1577 4
187

Condensate Drain
R 3/4

Air Vent Note:


38

INLET
B OUTLET
47 C 83 CONNECTION PIPE Rc3/4
A

490

30 235 Chilled Water


Connection
115 44
Terminal Block

32
70
248

88
251
Hot
Water
Connection

35
242

With Plenum

PLENUM DOWN
537
30 235
148
32

Model: Air Flow:


556

Serial No.: Cooling Capacity:


120

Volt/Phase/Hz: Heating Capacity:

Input Watt: External Static Pressure:

Input Amp.:
251

247
267
MODEL: MCW200C/300C/400C/600C

WIRING

L ORANGE BLACK
LF
M BROWN
MF M
BLACK
H YELLOW
HF
C RED G/Y
L
FIELD PROCURED
SWITCH
L
POWER BLUE
SOURCE N

G/Y
NOTE:
FIELD WIRING M: FAN MOTOR

DRAWING NO.MA067065A
187

242 206 20
54

RETURN AIR

PLENUM BACK
556
30 235
148
20
32
26

Model: Air Flow:

Serial No.: Cooling Capacity:

Volt/Phase/Hz: Heating Capacity:


120

Input Watt: External Static Pressure:

Input Amp.:
143

248

RETURN AIR
206
251

MODEL: MCW200C/300C/400C/600C

WIRING

L ORANGE BLACK
LF
M BROWN
MF M
BLACK
H YELLOW
HF
C RED G/Y
L
FIELD PROCURED
SWITCH
L
POWER BLUE
SOURCE N

G/Y
NOTE:
FIELD WIRING M: FAN MOTOR

DRAWING NO.MA067065A
20

35
242

28
MCW-F
Without Plenum A
100mm Number
UNIT SIZE Standard B C D E F
extension of Fans
drain pan
drain pan
D
MCW200F 714 814 448 487 505 507 467 1
MCW300F 884 984 618 657 675 677 637 1
MCW400F 1014 1114 748 787 805 807 767 2
MCW600F 1214 1314 A 948 987 1005 1007 967 2
MCW800FUNIT SIZE
1464 Standard
1564 100mm1198 1237B 1255C 1257D 1217
Number 3
MCW1000F 1564 Drain1664 extension
1298 1337 1355 1357 1317 3
pan Drain pan of Fans
MCW1200F 1824 1924 1558 1597 1615 1617 1577 4
MCW200F 714 814 448 487 505 1
MOUNTING HOLE
4-10*16 MCW300F 884 984 618 657 675 1
59

MCW400F 1014 1114 748 787 805 2

MCW600F 1214 1314 948 987 1005 2


187

CONDENSATE DRAIN MCW800F 1464 1564 1198 1237 1255 3


R 3/4
MCW1000F 1564 1664 1298 1337 1355 3
AIR VENT MCW1200F 1824 1924 1558 1597 1615 4
38

47 C 88

490

30 235

148
WATER RETURN TERMINAL BLOCK

32
CONNECTION Rc3/4
26

WATER OUTLET

120
CAUTION
143

BE CAREFUL NOT TO DAMAGE THE


CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
248

251
WATER INLET

WATER SUPPLY
CONNECTION Rc3/4

35 242

With Plenum

DOWN RETUREN PLEUNM


537
30 235
148
32
556

Model: Air Flow:

Serial No.: Cooling Capacity:

Volt/Phase/Hz: Heating Capacity:

WATER OUTLET
Input Watt: External Static Pressure:

Input Amp.:
120

CAUTION
BE CAREFUL NOT TO DAMAGE THE
CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
247
251

MODEL: FTHC1H(02,03,04,06)AD(00,70)(A,B)00AF20AZ(A,B)1
267

WIRING
FAN SPEED
ORANGE BLACK
SWITCH LF
L BROWN
MF M~
M YELLOW BLACK
HF

WATER INLET H
SHF
RED G/Y

L
BLACK
POWER WHITE BLUE
SOURCE G/Y
N
MAIN SWITCH
G
G/Y
187

NOTE:
FIELD WIRING
M~: FAN MOTOR MF: FAN SPEED MEDIUM
G/Y: GREEN/YELLOW HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

DWG. No.: M08024067435

USE COPPER SUPPLY WIRES


ULTILISER FILS ELECTRIQUES EN CUIVRE

242 206 20
54

RETURN AIR

BACK RETURN PLENUM


556
30 235
148
20
32
26

Model: Air Flow:

Serial No.: Cooling Capacity:

Volt/Phase/Hz: Heating Capacity:

WATER OUTLET Input Watt: External Static Pressure:

Input Amp.:
120

CAUTION
143

BE CAREFUL NOT TO DAMAGE THE


CONNECTOR WITH TIGHT FORCE
WHEN PIPING.
248

206

RETURN AIR
251

MODEL: FTHC1H(02,03,04,06)AD(00,70)(A,B)00AF20AZ(A,B)1

WIRING
FAN SPEED
ORANGE BLACK
SWITCH LF
L BROWN
MF M~
M YELLOW BLACK

WATER INLET
HF
H RED G/Y
SHF
L
BLACK
POWER WHITE BLUE
SOURCE G/Y
N
MAIN SWITCH
G
G/Y

NOTE:
FIELD WIRING
M~: FAN MOTOR MF: FAN SPEED MEDIUM
G/Y: GREEN/YELLOW HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

DWG. No.: M08024067435

USE COPPER SUPPLY WIRES


ULTILISER FILS ELECTRIQUES EN CUIVRE
20

35 242

NOTES:
1) ALL DIMENSIONS ARE IN mm.
2) ALL STANDARD UNITS ARE WITHOUT BACK AIR PLENUM AND BOTTOM REMOVEAL FILTERS.
3) RIGHT HAND COIL CONNECTION SHOWN.
4) WIRING CONNECTION SIDE IS THE SAME AS COIL AND DRAIN CONNECTIONS.

29
Electrical Data
220-240V/1Ph/50Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 220-240/1/50
0Pa
RATED INPUT POWER W 21 33 45 65 103 105 133
MOTOR
RATED RUNNING CURRENT A 0.10 0.15 0.20 0.30 0.47 0.48 0.60
POLES 6
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 220-240/1/50
30Pa
RATED INPUT POWER W 42 59 67 111 157 177 221
MOTOR
RATED RUNNING CURRENT A 0.19 0.27 0.30 0.50 0.71 0.80 1.00
POLES 4
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 220-240/1/50
60Pa
RATED INPUT POWER W 47 69 83 149 205 219 271
MOTOR
RATED RUNNING CURRENT A 0.21 0.31 0.38 0.68 0.93 1.00 1.23
POLES 4
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 220-240/1/50
80Pa
RATED INPUT POWER W 51 73 97 157 215 237 281
MOTOR
RATED RUNNING CURRENT A 0.23 0.33 0.44 0.71 0.98 1.08 1.28
POLES 4

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL ELECTRIC DATA ARE BEING TESTED UNDER HIGH SPEED.

Power Input and Current of Medium and Low Speed


MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
MEDIUM W 17 27 35 49 71 75 99
POWER INPUT
0Pa LOW W 15 21 29 45 63 67 91
MOTOR MEDIUM A 0.08 0.12 0.17 0.24 0.34 0.36 0.46
CURRENT
LOW A 0.07 0.11 0.14 0.22 0.31 0.32 0.44
MEDIUM W 34 49 53 83 121 137 171
POWER INPUT
30Pa LOW W 27 43 43 65 99 113 135
MOTOR MEDIUM A 0.16 0.24 0.27 0.40 0.56 0.65 0.80
CURRENT
LOW A 0.13 0.21 0.23 0.32 0.47 0.54 0.65
MEDIUM W 39 58 63 123 185 183 235
POWER INPUT
60Pa LOW W 35 47 53 105 163 159 209
MOTOR MEDIUM A 0.19 0.29 0.30 0.57 0.84 0.86 1.07
CURRENT
LOW A 0.17 0.26 0.26 0.49 0.74 0.74 0.95
MEDIUM W 45 60 71 125 193 189 237
POWER INPUT
80Pa LOW W 37 51 57 113 175 173 221
MOTOR MEDIUM A 0.21 0.30 0.33 0.57 0.88 0.87 1.09
CURRENT
LOW A 0.18 0.27 0.28 0.52 0.80 0.80 1.01

NOTES:
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

30
115V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 115/1/60
0Pa
RATED INPUT POWER W 35 47 56 88 115 132 173
MOTOR
RATED RUNNING CURRENT A 0.30 0.41 0.49 0.77 1.00 1.15 1.50
POLES 6
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 115/1/60
30Pa
RATED INPUT POWER W 54 73 100 143 196 210 276
MOTOR
RATED RUNNING CURRENT A 0.47 0.63 0.87 1.24 1.70 1.83 2.40
POLES 4
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 115/1/60
60Pa
RATED INPUT POWER W 63 97 111 183 263 281 353
MOTOR
RATED RUNNING CURRENT A 0.55 0.84 0.97 1.59 2.29 2.44 3.07
POLES 4
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 115/1/60
80Pa
RATED INPUT POWER W 72 107 125 187 253 283 353
MOTOR
RATED RUNNING CURRENT A 0.63 0.93 1.09 1.63 2.20 2.46 3.07
POLES 4

208-230V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 208-230/1/60
80Pa
RATED INPUT POWER W 75 97 125 175 248 270 335
MOTOR
RATED RUNNING CURRENT A 0.36 0.47 0.60 0.84 1.19 1.30 1.61
POLES 4

265-277V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
IP/INSULATION GRADE IP20/E
POWER SOURCE V/Ph/Hz 265-277/1/60
80Pa
RATED INPUT POWER W 74 97 124 180 245 269 343
MOTOR
RATED RUNNING CURRENT A 0.28 0.37 0.47 0.68 0.92 1.02 1.29
POLES 4

NOTES:
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL ELECTRIC DATA ARE BEING TESTED UNDER HIGH SPEED.

31
Power Input and Current of Medium and Low Speed

115V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200
MEDIUM W 59 79 109 157 237 237 309
POWER
INPUT LOW W 51 67 93 145 221 217 287
0Pa
MOTOR MEDIUM A 0.54 0.73 0.96 1.38 2.06 2.09 2.71
CURRENT
LOW A 0.48 0.64 0.85 1.26 1.92 1.92 2.53
MEDIUM W 57 76 104 150 223 225 286
POWER
INPUT LOW W 49 65 89 136 210 211 272
30Pa
MOTOR MEDIUM A 0.53 0.71 0.92 1.33 1.96 2.00 2.58
Current
LOW A 0.46 0.62 0.82 1.20 1.84 1.85 2.46
MEDIUM W 55 73 99 141 215 217 279
POWER
INPUT LOW W 47 61 85 129 203 197 261
60Pa
MOTOR MEDIUM A 0.51 0.69 0.89 1.24 1.89 1.93 2.45
Current
LOW A 0.44 0.60 0.79 1.15 1.79 1.77 2.30
MEDIUM W 53 69 93 135 209 211 265
POWER
INPUT LOW W 45 57 81 123 193 187 247
80Pa
MOTOR MEDIUM A 0.49 0.67 0.86 1.20 1.84 1.85 2.33
Current
LOW A 0.43 0.57 0.76 1.10 1.69 1.70 2.20

208-230V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200

POWER MEDIUM W 81 102 126 182 258 285 320


INPUT LOW W 69 88 109 147 181 230 260
80Pa
MOTOR MEDIUM A 0.35 0.47 0.55 0.80 1.13 1.33 1.30
Current
LOW A 0.31 0.42 0.49 0.66 0.90 1.25 1.10

265-277V/1Ph/60Hz
MODEL MCW200 MCW300 MCW400 MCW600 MCW800 MCW1000 MCW1200

POWER MEDIUM W 55 81 109 147 195 243 293


INPUT LOW W 47 58 81 118 153 196 244
80Pa
MOTOR MEDIUM A 0.24 0.36 0.42 0.59 0.78 1.02 1.13
Current
LOW A 0.20 0.28 0.35 0.51 0.62 0.82 1.06

NOTES:
ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

32
Wiring Diagrams
Wiring(C/H/F)
Electrical wiring connection must be done according to the wiring diagram on the unit.
The unit must be GROUNDED to the earth system of the building.
All field wiring must be installed in accordance with the national wiring regulation and Fire Department
regulation.

FOR MODEL: MCW200 MCW300 MCW400 MCW600 (0Pa and 30Pa)

WIRING

L ORANGE
LF BLACK
M BROWN
MF M~
H BLACK
YELLOW
HF
G/Y
FAN SPEED RED
L
SWITCH
MAIN SWITCH L

POWER BLUE
N
SOURCE

G/Y
NOTE:
LF: FAN SPEED LOW
FIELD WIRING
MF: FAN SPEED MEDIUM
M~: FAN MOTOR HF: FAN SPEED HIGH

FOR MODEL: MCW800 MCW1000 MCW1200 (0Pa and 30Pa)

WIRING

L ORANGE
LF BLACK
M BROWN
MF M1
H BLACK
YELLOW
HF
G/Y
FAN SPEED RED
L
SWITCH
ORANGE
MAIN SWITCH L BLACK

POWER BLUE BROWN


N M2
SOURCE
BLACK
YELLOW

BLUE G/Y
G/Y
NOTE:
LF: FAN SPEED LOW
FIELD WIRING
MF: FAN SPEED MEDIUM
M1,M2: FAN MOTOR HF: FAN SPEED HIGH

33
FOR MODEL: MCW200 MCW300 MCW400 MCW600 (60Pa and 80Pa)

WIRING

L ORANGE BLACK
LF
M BROWN
MF M~
H YELLOW BLACK
HF
G/Y
FAN SPEED RED
SWITCH SHF
L
POWER BLUE
SOURCE
N
MAIN SWITCH
G/Y

NOTE:
FIELD WIRING MF: FAN SPEED MEDIUM
M~: FAN MOTOR HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

60Pa: LF—Low Speed MF—Medium Speed HF—High Speed


80Pa: MF—Low Speed HF—Medium Speed SHF—High Speed

FOR MODEL: MCW800 MCW1000 MCW1200 (60Pa and 80Pa)

WIRING

L ORANGE BLACK
LF
M BROWN
MF M1
H YELLOW BLACK
HF
G/Y
FAN SPEED RED
SWITCH SHF
L ORANGE BLACK
POWER BLUE
SOURCE
N BROWN
M2
MAIN SWITCH YELLOW BLACK
G/Y
RED G/Y

NOTE:
FIELD WIRING MF: FAN SPEED MEDIUM
M1,M2: FAN MOTOR HF: FAN SPEED HIGH
LF: FAN SPEED LOW SHF: FAN SPEED SUPER HIGH

60Pa: LF—Low Speed MF—Medium Speed HF—High Speed


80Pa: MF—Low Speed HF—Medium Speed SHF—High Speed

34
MODEL: MCW2CD/3CD/4CD/6CD

Detail A A B
ORANGE FAN MOTOR CAPACITOR
FAN MOTOR ORANGE FAN MOTOR BLACK LOW
LOW ORANGE BLACK LOW THERMOSTAT LF BLACK
THERMOSTAT LF THERMOSTAT LF
MED BROWN BLACK
MED MED M1~
BROWN CAPACITOR BROWN MF
MF MF M~ HIGH
M~ HIGH YELLOW
HIGH
HF
YELLOW BLACK YELLOW
HF HF BLACK
HEAT OFF COOL SHF
BLUE FAN MOTOR CAPACITOR
BLACK
HEAT OFF COOL RED HEAT OFF COOL
SHF SHF
H BLACK
C
SOLENOID VALVE M2~
H BLUE H BLUE
L
SOLENOID VALVE TH BLUE
4 5 N
L MODEL: MCW2CD/3CD/4CD/6CD @ 0Pa & 30Pa ESP
MODEL: MCW8CD/10CD/12CD @ 0Pa & 30Pa ESP
N KM
HEATER 1
L1 T1 FU1
BREAKER L 1 A B
ORANGE FAN MOTOR CAPACITOR
FU2 ORANGE FAN MOTOR BLACK LOW
L2 T2 LOW THERMOSTAT LF BLACK
2 THERMOSTAT LF
220-240V~/50Hz N
MED BROWN BLACK
Detail C HEATER 2 MED M1~
BROWN MF
3 MF HIGH
HIGH
M~ YELLOW
HF
YELLOW
HF BLACK RED
HEAT OFF COOL SHF
BLUE FAN MOTOR CAPACITOR
BLACK
HEAT OFF COOL RED
SHF
H BLACK
SOLENOID VALVE M2~
H BLUE
L
MODEL: MCW8CD/10CD/12CD BLUE
N
MODEL: MCW2CD/3CD/4CD/6CD @ 60Pa ESP
Detail B
MODEL: MCW8CD/10CD/12CD @ 60Pa ESP
ORANGE FAN MOTOR CAPACITOR
THERMOSTAT LOW LF BLACK
For MCW2-12CD with Electrical Heater

MED BROWN BLACK A B


ORANGE FAN MOTOR CAPACITOR
MF M1~ ORANGE FAN MOTOR BLACK LOW
LOW THERMOSTAT LF BLACK
HIGH THERMOSTAT LF

35
YELLOW MED BROWN BLACK
HF MED M1~
BROWN MF
MF M~ HIGH
RED HIGH YELLOW
HEAT OFF COOL SHF HF
BLUE FAN MOTOR CAPACITOR YELLOW
BLACK HF BLACK RED
HEAT OFF COOL SHF
H BLUE FAN MOTOR CAPACITOR
BLACK BLACK
HEAT OFF COOL RED
SOLENOID VALVE M2~ SHF
H BLACK
L SOLENOID VALVE M2~
H BLUE
L
BLUE
N BLUE
N
TH1 TH2 TH3 MODEL: MCW2CD/3CD/4CD/6CD @ 80Pa ESP
5 6 KM
BREAKER R MODEL: MCW8CD/10CD/12CD @ 80Pa ESP

S HEATER1
380-415V/3N~/50Hz L1 T1 FU1
1
T FU2 HEATER2
L2 T2
2
N L3 T3 FU3 HEATER3
3 NOTE͹
LEGEND
HEATER4 Detail AThese drawings shows the MCW2-6CD motors
FU4 wire connection @ difference ESP LF: Low Speed KM: Contacor
4
FU5 HEATER5 MF: Medium Speed FU1-6: FUSE(153°C,15A)
Detail BThese drawings shows the MCW8-12CD motors
wire connection @ difference ESP
HEATER6 HF: High Speed TH1-3: THERMOSTAT(50°C,10A)
FU6
Detail CFU2, FU3... HEATER2, HEATER3...may exist,
C which will be determined by the unit's configuration SHF: Super High Speed - - - - - FIELD WIRING
Installation
Receiving
All units leaving the McQuay plant have been inspected to ensure the shipment of high quality products and
reasonable means are utilized to properly pack the fan coil units to protect them in transit.
Carefully inspect all shipments immediately upon delivery. When damage is visible, note this fact on the
carrier’s freight bill and request that the carrier sends a representative to inspect the damage. This may be
done by telephone or in person, but should always be confirmed in writing.
The shipment should be unpacked in the presence of the agent so that the damage or loss can be
determined.
The carrier’s agent will make an inspection report and a copy will be given to the consignee for forwarding
to the carrier with a formal claim.

Location
Before installation, please check the following:
There must be enough space for unit installation and maintenance. Please refer to the unit’s drawings and
dimensions and fig.1 for the minimum distance between the unit and obstacle.
Please ensure enough space for piping connection and electrical wiring.
Please make sure that the hanging rods can support weight of the unit.

Installation
The unit is designed for concealed ceiling installation.
There are holes on the top of the unit for hanging. Please refer to Fig.1.Fig.2 and Fig.3.
Make sure that the top of the unit is level.

Insulation
1) Use proper insulation material only
2) Chilled water pipes and all parts on the pipes should be insulated
3) It is also necessary to insulated air ducted
4) Adhesive for insulation should work under range 0˚F(-18˚C) to 200˚F(93.3˚C).

Fig.1

OBSTACLE OBSTACLE

B A
C

CEILING

A≥200mm B≥400mm C≥265mm

36
Fig.2 WITH AND WITHOUT PLENUM FORM:

Terminal block

Ceiling access
Panel with air return

Discharge air Return air

Fig.3 DETAIL A:

EXP ANSION SCREW


NUT RECOMMENDED THE
DIAMETER IS 6-8MM
HANGING ROD
FANCOIL FLAT WASHER

Air Duct Connection


Circulatory air pressure drop should be within External Static Pressure
Galvanized steel air ducts are suitable
Make sure there is no leak of air.
Air duct should be fireproof, refer to concerned country national and local regulations.

Pipe Connection
Using suitable fittings as water pipe connections. Refer to the specification
The water inlet is on the bottom while outlet on top.
The connection must be concealed with rubberized fabric to avoid leakage.
Drainpipe can be PVC or steel.
The suggested slope of the drainpipe is at least 1:50.

Wiring
1) Wiring connection must be done according to the wiring diagram on the unit.
2) The unit must be GROUNDED well.
3) An appropriate strain relief device must be used to attach the power wires to the terminal box.
4) A 7/8” knockout hole is designed on the terminal box for field installation of the strain relief device.
5) Field wiring must be complied with the national security regulations.

37
Valve Kit
The valve kit is applied for 2-pipe system.
The kit consists of (refer structure figure 0):
• 2/3 way valve body is made of brass, maximum working pressure 1.6MPa.
• Electric actuator has the following specifications:
-Power supply: 220V±10%/50/60Hz (±2Hz)
-Activation: ON/OFF
• Hydraulic kit for the installation of the valve on the heat exchanger, complete with 2 ball valves for
adjusting the water flow and for closing the water circuit when perform maintenance to the unit.
• Y-strainer protects unit from impurity, increases the service life and insolating valves.

Figure 0

All parts of 2-way valve kit are indicated in the figure 1. ( For right pipe connection unit.)

F
E A Ball valve
B Brass connector
C Y-strainer
D Water inlet pipe
E Water outlet pipe
A
F 2-way valve
B
C
Figure 1
D

All parts of 3-way valve kit are indicated in the figure 2. ( For right pipe connection unit.)

A Ball valve
B Brass connector
G C Y-strainer
D Connector pipe
F
A
E Water inlet pipe
B F 3-way valve
C G Water outlet pipe
E D

Figure 2

38
Installation
1. Install the 2-way valve kit as indicated in the pictures of figure 3. (For right pipe connection unit.) As
shown as detail A, firstly take apart connector, then install ① to unit with necessary sealing material . Fix
② between ① and ③. At last tighten ③, make sure all of connectors are sealed.
2. Install the 3-way valve kit as indicated in the pictures of figure 4. (For right pipe connection unit.) Detail is
as same as 2-way valve unit.

The valve kit has been pre-assembled for easy installation.


• Where needed the connections are pre-coated with sealing material.
• The connections are not tightened for easy adjustment.
• After determining the final position of the valve kit, tighten all connections to obtain water tightness.

WATER RETURN CONNECTION Rc3/4


WATER SUPPLY CONNECTION Rc3/4

209
65

220
203 ķ
ĸ
A
Detail A

146
Figure 3 2-Way Valve

218
153

Ĺ
300

ķ
ĸ
Detail A

WATER RETURN CONNECTION Rc3/4

WATER SUPPLY CONNECTION Rc3/4

A
210
120

39
Insulation
1. The insulation design and materials should be complying with local and national codes and regulations.
2. Chilled water pipes and all parts on the pipes should be insulated.

The flow resistance of the connecting valve/hydraulic kit assembly is obtained from the following formula:

△PW = (QW/100Kv)2

PW is the flow resistance (Pa)

QW is the water flow rate (m3/h)

Kv is the flow rate identified in the table

Conncetion Shut-off Pressure


Valve Model DN Valve Type KV
Type Difference (MPa)
MC-FCV3335G 20 Rc3/4" 3-way Valve 3.4 0.18
MC-FCV2334G 20 Rc3/4" 2-way Valve 3.0 0.18

Pipe Connection
1. Using suitable fittings as water pipe connections with reference to the outline and dimensions.
2. The water inlet is on the bottom while outlet on top.
3. The connection must be concealed with rubberized fabric to avoid leakage.
4. Tightening torque should not be too high when connecting water pipes, in order to avoid brass deformation
or water-leakage by torsion split.

Wiring
1. Refer to the wiring diagram of the appropriate controller.
2. For connection with the McQuay controller, position the water temperature probe into the appropriate
position. Refer to the dedicated controller installation and operation manual.

40
Guide Specifications
Unit Description
Factory-assembled, horizontal, blow-thru type, galvanized casing, ceiling ducted fan coil unit is complete with
water coil, fans, motors, drain pan, filters and all required wiring, with full access to internal components.

Quality Assurance
Each coil is factory tested for leakage at 2.0MPa air pressure with coil submerged in water. Each unit and its
moving components (fans and motors) are factory computer-tested and recorded after unit is complete and
before it is packed.

Component Specifications
1.Casing:
Construction is of 0.8mm thickness galvanized steel, lined on the inside with 5mm PE thermal and acoustical
insulation. Return air plenum is lined with 5mm PE foam and has a 30mm collar for return duct connection.
Supply duct connection also has a 30mm long collar. Removable bottom panel is provided for access to the
fan/motor assembly.
2. Coil:
Standard unit is equipped with a 3-row (C series), 4-row (F series) or 3+1 rows (H series) coil for installation in a
2-pipe (C and F series) or 4-pipe (H series) system. Coil has 3/8 inch seamless copper tubes, slit type fins
hydrophilic aluminum bonded to the tubes by mechanical expansion. Each coil has a manual air vent and
two Rc3/4 water pipe connections with a maximum working pressure of 1.6MPa.
3. Fan:
Direct-driven centrifugal fan wheel has forward-curved blades which are statically and dynamically
balanced.
The fan housing and blades are constructed of high quality hot-galvanized steel.
4.Motor:
Fan motor is 3-speed, permanent split-capacitor with ball type bearing and build-in automatic reset thermal
overload protection. The motor’s insulation is class E.
5. Drain pan
The drain pan plate body is constructed of cold-rolled steel by way of integral cupping. Both its sides are
sprayed with plastic coating. And its outer wall is lined with 7mm heat insulating PE foam and high quality
adhesive by way of integral adhering and pressing. It extends under the full length and width of the coils
and is pitched for positive drainage with features of high anti-corrosion, anti-condensation and high fire
reluctance.
6. Filter
Filter is with washable type nylon media in 8mm thickness aluminum frame.

41
ISO 9001 BS-OHSAS 18001 ISO 14001
Certificate No.: 9601019 Certificate No.: 7644 Certificate No.: EMS 80362

©2013 McQuay International +1 (800) 432-1342 www.mcquay.com

While utmost care is taken in ensuring that all details in the publication are correct at the time of going
to press, we are constantly striving for improvement and therefore reserve the right to alter model
specifications and equipment without notice.
Details of specifications and equipment are also subject to change to suit local conditions and requirements
and not all models are available in every market.

You might also like