RE.316*4
Technology and Solutions
Protection and Substation Automation Technology
BASICS
© ABB Switzerland Ltd. - 1
RE.316_basic / 2003-10-01 / RW
RE.316*4 Technology Basics
Objectives
Application
M
G
© ABB Switzerland Ltd. - 3
RE.316_basic / 2003-10-01 / RW
REL316*4 Main Protection Application
⇒ Distance (21)
⇒ High Voltage (HV) Distance (21)
⇒ Line-Differential (87)
⇒ Directional Ground Fault (32N)
(ungrounded systems / Peterson coil)
⇒ Directional Ground Fault (67N)
(grounded systems)
⇒ Auto- Reclosure (79)
⇒ Synchro- Check (25)
© ABB Switzerland Ltd. - 4
RE.316_basic / 2003-10-01 / RW
Line Protection
Terminal
RET316*4 Main Protection Application
Transformer
Protection Terminal
REG316*4 Main Protection Application
⇒ Generator Differential (87G)
⇒ Transformer Differential (87T)
⇒ 100% Stator Ground Fault (64S)
⇒ 100% Rotor Ground Fault (64R)
⇒ Definite Time Voltage for Stator Ground Fault
and Rotor Ground Fault (27/59)
⇒ Frequency and Frequency rate-of-change (81)
⇒ Pole Slip (78)
⇒ Minimum Impedance (21)
⇒ Minimum Reactance (40)
© ABB Switzerland Ltd. - 6
RE.316_basic / 2003-10-01 / RW
REG316*4 Main Protection Application
⇒ Overexcitation (24)
⇒ Negative Phase Sequence (46)
⇒ Inverse Time Negative Phase Sequence (46)
⇒ Stator Overload (49S)
⇒ Rotor Overload (49R)
⇒ Dead Machine (51/27)
© ABB Switzerland Ltd. - 7
RE.316_basic / 2003-10-01 / RW
Generator
Protection Terminal
REC316*4 Main Protection & Control Application
⇒ Control (FUPLA)
⇒ Auto- Reclosure (79)
⇒ High Speed Busbar Tranfer for 2 CB (HBT)
⇒ High Speed Busbar Tranfer for 3 CB (HBT)
© ABB Switzerland Ltd. - 8
RE.316_basic / 2003-10-01 / RW
Protection &
Control Terminal
RE.316*4 Additional Protection Application
⇒ Inverse Time Overcurrent (51)
⇒ Inverse Time Ground Fault (51N)
⇒ Directional Definite Time Overcurrent (67)
⇒ Directional Inverse Time Overcurrent (67)
⇒ Instantaneous Overcurrent (51)
⇒ Definite Time Overcurrent (51DT)
⇒ Breaker Failure (50BF)
⇒ Definite Time Voltage (27/59)
⇒ Thermal Overload (49)
© ABB Switzerland Ltd. - 9
RE.316_basic / 2003-10-01 / RW
RE.316 *4 Protection
& Control Terminal
RE.316*4 Additional Auxiliary Functions
⇒ Voltage Plausibility
⇒ Current Plausibility
⇒ Disturbance Recorder
⇒ Binary Signal Transmission
⇒ Logic
⇒ Counter
⇒ Delay / Integrator
⇒ Metering
© ABB Switzerland Ltd. - 10
RE.316_basic / 2003-10-01 / RW
RE.316 *4 Protection
& Control Terminal
RE.316*4 Code Concept
The Configuration (HW & SW) of the Unit is
defined by the Identification Code
Identification code for Ordering, Manufacturing and MMC set-up
Hardware Software
In Un A/I's Uaux B/I's and B/O's Com. Design SW key FUPLA
REC 316 A _ B _ C _ D _ U _ K _ _ H _ E _ I _ F _ J _ Q _ V _ R _ W _ Y _ N _ M _ S _ _ _ _ T _ _ _
REG 316 A _ B _ C _ D _ U _ K _ _ H _ E _ I _ F _ J _ Q _ V _ R _ W _ Y _ N _ M _ S _ _ _ _ T _ _ _
REL 316 A _ B _ U _ K _ _ H _ E _ I _ F _ J _ Q _ V _ R _ W _ Y _ N _ M _ S _ _ _ _ T _ _ _
RET 316 A _ B _ C _ D _ U _ K _ _ H _ E _ I _ F _ J _ Q _ V _ R _ W _ Y _ N _ M _ S _ _ _ _ T _ _ _
without FUPLA
<Z, E/Fungnd,AR,SC,Basic-SW
semi-flush mounting
casing width 221mm
© ABB Switzerland Ltd. - 11
no communication protocol
RE.316_basic / 2003-10-01 / RW
CT rated current 1A
Hardware Concept
Front View / Size
½ 19‘‘ rack ¾ 19‘‘ rack
C C
© ABB Switzerland Ltd. - 12
RE.316_basic / 2003-10-01 / RW
E E
Sub code N1 N2
Hardware Concept
Mounting
Semi- Flash Surface
© ABB Switzerland Ltd. - 13
RE.316_basic / 2003-10-01 / RW
Sub code M1 M5
Hardware Concept
Location of Units
• basic
7 4 3 4 1
1) Analog input unit
6 up to 9 transformer
6) Mother Board
Sub code N1 7) Power Supply
Hardware Concept
Location of Units
• basic
7 4 4 4 4 321
1) Analog input unit
6 up to 9 transformer
6) Mother Board
Sub code N2 7) Power Supply
Hardware Concept
Location of Units with
• Line Differential or
• Binary Signal
Transmission
7 4 4 4 4 321
1) Analog input unit
6 up to 9 transformer
2) Digital / Optical unit
3) CPU with serial port
R
6) Mother Board
Sub code N2 7) Power Supply
Hardware Concept
Location of Units with Interbay Bus (SCS / SMS)
Interbay bus
C
5) Communication PCMCIA
E
6) Mother Board
Sub code N2 7) Power Supply
Hardware Concept
Location of Units with Process Bus (Remote I/O)
C
RE.316_basic / 2003-10-01 / RW
E
6) Mother Board
7) Power Supply
8) Process bus Interface
Sub code N2
(MVB PC-Card)
Hardware Concept
Location of Units
Complete
5
1) Analog input unit
7 4 4 4 48 321 up to 9 transformer
2) Digital / Optical unit
6
3) CPU with serial port
4) Binary input/output unit
R
5) Communication PCMCIA
© ABB Switzerland Ltd. - 19
RE.316_basic / 2003-10-01 / RW
E 6) Mother Board
7) Power Supply
8) Process bus Interface
Sub code N2
(MVB PC-Card)
Hardware Concept
DC
+5V
+15V
CPU -15V DC
Power
Supply
A/D DSP DPM 486DX +24V AC Remote I/O
Remote I/OTrip
Outputs
Remote I/O
Trip
Sign.
SW-Key Outputs
Outputs
Trip Trip
PC-Card Sign.
Trip
Outputs FLASH OutputsBin.
Trip Outputs
Outputs EPROM IEC1375 Sign.Inputs
Trip Sign. I / IO/ O
Outputs Bin.
Sign.
Outputs
Outputs I / OPorts P a (MVB) Outputs
Inputs
Sign.
Outputs
Sign. OPorts
I /Ports C Process bus Bin.
OutputsBin. Tranceiver
Outputs Ports Inputs
Bin.
Inputs
Bin.
- b
Inputs
Bin.
Inputs C PC-Card
Inputs
RAM
A c
e.g. LON
R LON
d
D
SCS
LED's
SMS
RS Serial RS Serial
232 Controller 232 Controller SPA / IEC870-5-103 (VDEW6)
E
© ABB Switzerland Ltd. - 20
RE.316_basic / 2003-10-01 / RW
MMC
RX Tx DC
+5V
+15V
CPU -15V DC
Power
Supply
A/D DSP DPM 486DX +24V AC Remote I/O
Remote I/OTrip
Outputs
Remote I/O
Trip
Sign.
SW-Key Outputs
Outputs
Trip Trip
PC-Card Sign.
Trip
Outputs FLASH OutputsBin.
Trip Outputs
Outputs EPROM IEC1375 Sign.Inputs
Trip Sign. I / IO/ O
Outputs Bin.
Sign.
Outputs
Outputs I / OPorts P a (MVB) Outputs
Inputs
Sign.
Outputs
Sign. OPorts
I /Ports C Process bus Bin.
OutputsBin.
Outputs Ports Tranceiver Inputs
Bin.
Inputs - b
Bin.
Inputs
Bin.
Inputs C PC-Card
Inputs
RAM
A c
e.g. LON
R LON
d
D
SCS
LED's
SMS
RS Serial RS Serial
232 Controller 232 Controller SPA / IEC870-5-103 (VDEW6)
E
© ABB Switzerland Ltd. - 21
RE.316_basic / 2003-10-01 / RW
MMC
•
Hardware Concept
Hardware Concept
RE.316*4 Analog input Sub code Nominal
Value
• Analog Inputs CT inputs 1- 3 A 0 not available
Nominal Values 1 1A
2 2A
5 5A
MT inputs B 0 not available
1 1A
2 2A
5 5A
CT inputs 4-6 C 0 not available
1 1A
2 2A
5 5A
CT inputs 7-9 D 0 not available
1 1A
2 2A
© ABB Switzerland Ltd. - 23
5 5A
RE.316_basic / 2003-10-01 / RW
Hardware Concept
REL316*4
• Analog Inputs Configuration
Sub code
Transformer type K01 K03 K04 K05 K08 K09 K15 K16 K17
1x3ph 1x3ph 1x3ph 1x3ph
CT's protection characteristic 1x3ph 1x3ph 1x3ph 1x3ph 1x3ph
2x1ph 1x1ph 2x1ph 1x1ph
Hardware Concept
RET316*4
• Analog Inputs Configuration
Sub code
K21 K22 K23 K24
CT's protection characteristic 2x3ph 3x3ph 2x3ph 2x3ph
Hardware Concept
REG316*4
• Analog Inputs Configuration
Transformer type
Sub code K61 K62 K63 K64 K65 K66 K67
CT's protection characteristic 2x3ph 1x3ph 2x3ph 1x3ph 3x3ph 1x3ph 1x3ph
Hardware Concept
REC316*4
• Analog Inputs Configuration
Hardware Concept
RE.316*4
• Binary In- and Output Units
Sub code E F Q R
316 DB61 8 opto coupler inputs 1 1 1 1
6 signalling relay outputs
2 command relays
8 LEDs (only in Unit 1 & 2)
316 DB62 4 opto coupler inputs 2 2 2 2
10 signalling relay outputs
2 command relays
8 LEDs (only in Unit 1 & 2)
316 DB63 14 opto coupler inputs 3 3 3 3
8 signalling relay outputs
© ABB Switzerland Ltd. - 28
not - 0 0 0
available
Hardware Concept
RE.316*4
• Opto Coupler Input Voltage (for DB61 / DB62 / DB63)
Sub code I J V W
DC Voltage 82 – 312 VDC 3 3 3 3
36 – 75 VDC 4 4 4 4
18 – 36 VDC 5 5 5 5
175 – 312 VDC 9 9 9 9
not available - 0 0 0
© ABB Switzerland Ltd. - 29
RE.316_basic / 2003-10-01 / RW
Software Concept
Hardware Key
Binary Dist.
Dist.
Z< 3 I0 Ucos Z< Signal
21 67N 78 21 Rec.
Rec.
© ABB Switzerland Ltd. - 30
Trans.
RE.316_basic / 2003-10-01 / RW
Software Concept
CPU Capacity
SETFILE
Software Concept
REL316*4 (example)
Sub code SX.XXX
• Basic Versions
© ABB Switzerland Ltd. - 32
RE.316_basic / 2003-10-01 / RW
1 T:RT =1 Q0_SUP_SEL_REL_Q0
ALSY Q0_ALSY
BKS Q0_BLOCK_SELECT
KDOF Q0_KDO_FAIL
S
A/I MUX A/D Analog to
H digital
conversion
COM MMI
I> Numerical
DSP U<
Z< SCS/ signal
1 DiffGen on
COM SMS processing
2 Current on
3 BinInp 2 off
etc.
Trip
Binary
signal
© ABB Switzerland Ltd. - 37
B/I
RE.316_basic / 2003-10-01 / RW
etc.
B/O processing
Signal Data Flow
Typical tripping time
Algorithm and
Logic
Analog processor
Binary
input Low pass A/D output
filter Multiplexing Conversion Z<
isolation isolation
∼
∼
S ∼
∼
I > FUPLA
∼ ∼
A/ I MUX A/D I B/O
H
Shunt Amplifier Sample Digital etc etc
& hold filter
0 ms 3 ms 5 ms 12 ms 21 ms 25 ms
© ABB Switzerland Ltd. - 38
RE.316_basic / 2003-10-01 / RW
Selfsupervision
Memories
Program Processing
Read/Write comparison
Checksum function Watchdog functions
External and internal
A/D-Conversion Power supply
continuous conversion Tolerance check
of 2 reference signals
DC
+5V
+15V Power
CPU -15V DC Supply
A/D DSP 486 +24V AC
FLASH SW-Key
EPROM
PC-Card
3ph-Voltages Trip
Outputs IEC 1375
and-Currents a
I/O Tranceiver
Sign. P Process bus
Symmetry check Outputs Ports C
b
-
Bin. RAM C PC-Card
Inputs
A c
R LON
D LON
d
© ABB Switzerland Ltd. - 39
RS RS
Signal Transfer 232 Serial Serial 232 Hamming distance 4 to 6
Controller Controller
Error correction coding by frame format definition,
RS RS
MMC
232 232 SPA / IEC 870-5-103 16 bit CRC or
check sum+parity bit
Communication Protocol
Station
Protokol Type - Sub code Automation
Interbay Bus System
no protokol Y 0
SPA Y 1
IEC 60870-5-103 Y 2
LON Y 3
Human-machine-
MVB (IEC 61375)* Y 4 R
communication
E
© ABB Switzerland Ltd. - 40
RE.316_basic / 2003-10-01 / RW
Process Bus
MVB (IEC 61375)* Remote
(* MVB either for Remote I/O or Process Bus) Input/Output Unit
Lokal Human Machine Interface (HMI)
LDU Functionality
• LED-displays
• Measurand display
REx5xx
DisturbanceRep
ServiceRep
• Event list
Functions
• Operating instructions
C • Disturbance recorded information
E • Self supervision
• Acknowledgement functions
• Optical connector for external MMI
© ABB Switzerland Ltd. - 41
RE.316_basic / 2003-10-01 / RW
© ABB Switzerland Ltd. - 42
RE.316_basic / 2003-10-01 / RW
Human Machine Interface (HMI) – CAP2/316
Human Machine Interface (HMI) – CAP2/316
used for
⇒ Settings
⇒ Configuration
⇒ Evaluation
⇒ Maintenance
⇒ Commissioning
⇒ Trouble Shooting
© ABB Switzerland Ltd. - 43
RE.316_basic / 2003-10-01 / RW
© ABB Switzerland Ltd. - 44
RE.316_basic / 2003-10-01 / RW