Connector m12 Control Cable Connector en 1318 Screen

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 86

Technical Information / Datasheet

Pos : 3 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-PBR / 275274500/Basisinfor mationen [SK T IE4-M12-PBR] @ 4\mod_1391775826150_388.doc x @ 116736 @ 5555 @ 1

SK TIE4-M12-PBR Part number: 275 274 500


PROFIBUS DP input and output connection extension
M12 BUS system connector

Scope of delivery
1x M12 Socket connector
SK TIE4-M12-PBR
1x M12 Plug connector
2x Cover cap violet
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the PROFIBUS DP
technology option with the outgoing PROFIBUS DP field bus cables at the input and output sides.

Technical data

Version
Temperature range -30 … +90 °C Weight (per component) 23 g
Contact insert Violet / RAL 4001 Connector cover Violet / RAL 4001
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Receptacle connector with Tightening torques *
flexible strand
M12x1 Socket plug 0.6 Nm
M16x1.5, metric screw connectors 1.5 Nm
thread
M16x1.5 Screw thread.
Contact insert 5 pin, B - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Connection extension SK TIE4-M12-PBR


1.1 Extensive revision 2414 Bch TI 275274500 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-PBR

Cable
Number of cores / cross- Mech. Service life min. 100 plugging cycles
2
section 4 x 0.34 mm
2
Socket connector 2 x 0.34 mm
Plug connector
Flexible strands / colours UL Operating voltage max. 60 V
Socket connector (br, gn, bl, rd)
Plug connector (gn, rd)
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

2/6 TI 275274500 - 2414


Connection extension – SK TIE4-M12-PBR

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

TI 275274500 - 2414 3/6


Connection extension – SK TIE4-M12-PBR

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 24 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-PBR / 275274500/Ans chl üss e [SK TIE4-M 12- PBR ] @ 4\mod_1391775824570_388.doc x @ 116711 @ 55 @ 1

4/6 TI 275274500 - 2414


Connection extension – SK TIE4-M12-PBR

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the BUS connection unit (technology box) or the BUS customer interface in the
frequency inverter or the motor starter (see below).

Frequency inverter BUS technology box BUS customer interface


and motor starter SK TU4-PBR (-M12) / (-C) SK CU4-PBR

Electrical connections

BUS technology box


Connection extension
SK TU4-PBR (-M12) /( -C) BUS customer interface
M12 Plug connector
BUS connection unit SK CU4-PBR
SK TIE4-M12-PBR
SK TI4-TU-BUS (-C)
Contact
assignments Pin ** Colour ** Signal Contact Designation Contact Designation
2-pole 2 green PBR A 5 PB A IN 81 PBR A
Plug connector 4 red PBR B 3 PB B IN 82 PBR B
B - coded

** the colour assignments and the colour-pin assignments were different in the pilot series:
Pin Colour Signal Contact Designation Contact Designation
2 green PBR A 5 PB A IN 81 PBR A
4 red PBR B 3 PB B IN 82 PBR B

BUS technology box


Connection extension
SK TU4-PBR (-M12) / (-C) BUS customer interface
M12 Socket connector
BUS connection unit SK CU4-PBR
SK TIE4-M12-PBR
SK TI4-TU-BUS (-C)

Contact Pin * Colour * Signal Contact Designation Contact Designation


assignments 1 brown +5V 10 +5 47 5V
2 green PBR A 6 PB A OUT 81 PBR A
4-pole
3 blue GND 8 0V B 46 0V B
Socket connector
4 red PBR B 4 PB B OUT 82 PBR B
B - coded

* the colour assignments and the colour-pin assignments were different in the pilot series:
Pin Colour Signal Contact Designation Contact Designation
1 red +5V 10 +5 47 5V
2 white PBR A 6 PB A OUT 81 PBR A
3 blue GND 8 0V B 46 0V B
4 black PBR B 4 PB B OUT 82 PBR B
Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

TI 275274500 - 2414 5/6


Connection extension – SK TIE4-M12-PBR

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 40 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-PBR / 275274500/Weiterführende D okumentati onen [SK TIE4-M 12- PBR ] @ 4\mod_1391775827058_388.doc x @ 116761 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0135 Motor starter manual SK 105E … SK 175E TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12
BU 0200 SK 2xxE frequency inverter manual
BU 0220 PROFIBUS DP for SK 200E TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C
TI 275280000 Bus connection unit SK TI4-TU-BUS
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275274510 Connection extension SK TIE4-M12-M16
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275274511 Connection reduction SK TIE4-M20-M16
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR

=== Ende der Liste für T extmar ke Inhalt ===

6/6 TI 275274500 - 2414


Technical Information / Datasheet
Pos : 1 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-CAO / 275274501/Basisinfor mationen [SK T IE4-M12-CAO] @ 4\mod_1382009922977_388.doc x @ 102432 @ 5555 @ 1

SK TIE4-M12-CAO Part number: 275 274 501


CANopen connection extension
M12 BUS system connector

Scope of delivery

1x M12 Plug connector SK TIE4-M12-CAO


1x Cover cap grey
As-delivered status with screwed-on connector cover

Field of use
The M12 Plug connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the CANopen
technology option with the incoming CANopen field bus cable at the input side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 7042 Connector cover Grey / RAL 7042
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable Plug M16x1.5 *
Round plug connector connector with flexible Tightening torques *
strand
M12x1 Male socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact insert 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (wt, br, bl, bk, gr) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-CAO


1.2 Extensive revision 2414 Bch TI 275274501 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-CAO

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptacle
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptacle connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274501 - 2414


Connection extension – SK TIE4-M12-CAO

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptacle connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptacle connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptacle connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptacle connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptacle connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptaclle connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274501 - 2414 3/5


Connection extension – SK TIE4-M12-CAO

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 22 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-CAO / 275274501/Ansc hl üss e [SK TIE4-M 12-C AO] @ 4\mod_1382018748132_388.doc x @ 102601 @ 55 @ 1

Connections
The open cable ends of the extension / M12 Plug connector are connected to the terminal strip of the
BUS connection unit (technology box) or the BUS customer interface in the frequency inverter (see
below).

BUS connection unit BUS technology box BUS customer interface


SK TI4-TU-BUS (-C) SK TU4-CAO (-M12) /( -C) SK CU4-CAO

Electrical connections

Connection extension BUS technology box


SK TU4-CAO (-M12 )/ (-C) BUS customer interface
M12 Plug connector
BUS connection unit SK CU4-CAO
SK TIE4-M12-CAO SK TI4-TU-BUS (-C)
Contact Pin Colour Signal Contact Designation Contact Designation
assignments 1 white Shield 9 SHLD 90 SHLD
2 Brown +24 V 1 24V-B CAO 45 24V bus
5-pole
3 Blue GND 7 GND B CAO 46 GND Bus
Plug connector 4 Black CAN_H 3 CAO+ OUT 75 (incoming) CANopen+
A-coded 5 grey CAN_L 5 CAO- OUT 76 (incoming) CANopen-

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274501 - 2414


Connection extension – SK TIE4-M12-CAO

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 38 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-CAO / 275274501/Wei terführende D okumentati onen [SK TIE4-M 12-C AO] @ 4\mod_1381136857579_388.doc x @ 100676 @ 5 @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0180 SK 180E, SK 190E frequency inverter manual TI 275281151 CANopen bus interface SK TU4-CAO-C
BU 0200 Frequency inverter manual SK 2xxE TI 275281201 CANopen bus interface SK TU4-CAO-M12
BU 0260 CANopen for SK 200E manual TI 275281251 CANopen bus interface SK TU4-CAO-M12-C
BU 0280 DEVICENET for SK 200E manual TI 275271002 DeviceNet bus interface SK CU4-DEV
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281102 DeviceNet bus interface SK TU4-DEV
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275281152 DeviceNet bus interface SK TU4-DEV-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275281202 DeviceNet bus interface SK TU4-DEV-M12
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C
TI 275271001 CANopen bus interface SK CU4-CAO TI 275274515 Connection extension SK TIE4-M12-CAO-OUT
TI 275281101 CANopen bus interface SK TU4-CAO

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274501 - 2414 5/5


Technical Information / Datasheet
Pos : 4 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-ASI / 275274502/Basisi nformati onen [SK TIE4-M 12- ASI] @ 4\mod_1392020076032_388.doc x @ 117054 @ 5555 @ 1

SK TIE4-M12-ASI Part number: 275 274 502


AS interface connection extension
M12 BUS system connector

Scope of delivery

1x M12 Plug connector SK TIE4-M12-ASI


1x Cover cap yellow
As-delivered status with screwed-on connector cover

Field of use
The M12 Plug connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the AS Interface
technology option with the incoming AS Interface field bus cable at the input side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 1018 Connector cover Yellow / RAL 1018
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable Plug M16x1.5 *
Round plug connector connector with flexible Tightening torques *
strand
M12x1 Socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 2 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-ASI


1.2 Extensive revision 2414 Bch TI 275274502 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-ASI

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.
Installation steps for installation of the M12 Receptacle connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/4 TI 275274502 - 2414


Connection extension – SK TIE4-M12-ASI

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274502 - 2414 3/4


Connection extension – SK TIE4-M12-ASI

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 25 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ASI / 275274502/Anschl üss e [SK TIE4-M12-ASI] @ 4\mod_1392020075200_388.doc x @ 117029 @ 55 @ 1

Connections
The open cable ends of the extension / M12 Plug connector are connected to the terminal strip of the
BUS connection unit (technology box), the BUS customer interface or the control terminal strip in the
frequency inverter or the motor starter (see below).

Frequency inverter BUS connection unit BUS technology box


and motor starter SK TI4-TU-BUS (-C) (SK TU4-… (-M12) / (-C)

Electrical connections

Connection extension Connecting terminals


M12 Plug connector SK 1x5E, SK 180 … 190E,
SK TIE4-M12-ASI SK 22xE, SK 23xE

Contact Pin Colour Signal Contact Designation


assignments 1 brown ASI + 84 ASI +
2-pole 3 blue ASI - 85 ASI -
Plug connector
A-coded

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 41 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ASI / 275274502/Weiterführende Dokumentationen [SK TIE4-M12-ASI] @ 4\mod_1392020077302_388.doc x @ 117079 @ 5 @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0090 AS interface (SK 300E … SK 750E) TI 275280500 Bus connection unit SK TI4-TU-BUS-C
BU 0135 Motor starter manual SK 105E … SK 175E TI 275274510 Connection extension SK TIE4-M12-M16
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275274511 Connection reduction SK TIE4-M20-M16
BU 0200 SK 2xxE frequency inverter manual TI 275274513 Connection extension SK TIE4-M12-ASI-AUX
TI 275280000 Bus connection unit SK TI4-TU-BUS
=== Ende der Liste für T extmar ke Inhalt ===

4/4 TI 275274502 - 2414


Technical Information / Datasheet
Pos : 5 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-INI / 275274503/Basisi nformati onen [SK TIE4-M 12- INI] @ 4\mod_1391594178437_388.doc x @ 114930 @ 5555 @ 1

SK TIE4-M12-INI Part number: 275 274 503


Connection extension for initiators and actuators
M12 control system connector

Scope of delivery
1x M12 Socket connector SK TIE4-M12-INI
1x Cover cap black
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the technology option
with the outgoing control signal cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Black / RAL 9005 Connector cover Black / RAL 9005
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Socket connector with Tightening torques *
flexible strand
M12x1 Socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, wt, bl, bk) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-INI


1.1 Extensive revision 2414 Bch TI 275274503 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-INI

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptacle
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.
Installation steps for installation of the M12 Receptacle connector
1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274503 - 2414


Connection extension – SK TIE4-M12-INI

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptacle connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptacle connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptacle connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptacle connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptacle connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptacle connector and tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274503 - 2414 3/5


Connection extension – SK TIE4-M12-INI

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 26 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN I / 275274503/Ansc hlüs se [SK T IE4-M12-INI] @ 4\mod_1391594177471_388.doc x @ 114905 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the BUS connection unit (technology box), the customer interface or the control
terminal strip in the frequency inverter or motor starter (see below).

Frequency inverter BUS connection unit Technology box Customer interface


and motor starter SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C) SK CU4-…

Electrical connections

Connection Connection
Technology box
extension terminals*** Customer
SK TU4-… (-M12) / (-C)
M12 Socket SK 1x5E, interface
Connection unit
connector SK 180E … SK 190E, SK CU4-…
SK TI4-TU-BUS (-C)
SK TIE4-M12-PBR SK 2xxE

Pin Colour Signal Contact Designation Contact Designation Contact Designation


Initiators

1 brown +24 V 43/44 ** 24 V 11/12 24 V 44 +24 V


2 white DIN 1-4 21-24 DIN1-4 19/20/25/26 DIN 1-4 C1/C2 DIN 1-4
3 blue GND 40 GND 15/17 GND 40 GND Bus
4 black DIN 1-4 21-24 DIN 1-4 19/20/25/26 DIN 1-4 C1/C2 DIN 1-4

Pin Colour Signal Contact Designation Contact Designation Contact Designation


Actuators*

1 brown +24 V 43 +24 V 44 24 V 31/32 24 V


2 white DOUT 1 1 DOUT 1 1 DOUT 1 33 DOUT 1
3 blue GND 40 GND 40 GND 35/36 0V
4 black DOUT 2 3 DOUT 2 3 DOUT 2 34 DOUT 2
* Only possible with series SK 2x0E devices
** 43: 24 V internal, SK 2x0E; 44: 24 V external, SK 2x5E
*** For series SK1xxE devices: Replace existing pin fork terminals with 8 mm wire end sleeves, otherwise secure contact cannot be guaranteed
over the long term.
Contact
assignments
4-pole
Socket
connector
A - coded

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274503 - 2414


Connection extension – SK TIE4-M12-INI

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 42 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN I / 275274503/Weiterführ ende Dokumentationen [SK T IE4-M12-INI] @ 4\mod_1391594179269_388.doc x @ 114955 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0135 Motor starter manual SK 105E … SK 175E TI 275271001 CANopen bus interface SK CU4-CAO
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281101 CANopen bus interface SK TU4-CAO
BU 0200 Frequency inverter manual SK 2xxE TI 275281151 CANopen bus interface SK TU4-CAO-C
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281201 CANopen bus interface SK TU4-CAO-M12
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275281251 CANopen bus interface SK TU4-CAO-M12-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271002 DeviceNet bus interface SK CU4-DEV
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281102 DeviceNet bus interface SK TU4-DEV
TI 275271010 Electronic brake rectifier, SK CU4-MBR TI 275281152 DeviceNet bus interface SK TU4-DEV-C
TI 275271011 Setpoint converter, SK CU4-REL TI 275281202 DeviceNet bus interface SK TU4-DEV-M12
TI 275271006 IO extension SK CU4-IOE TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C
TI 275281106 IO extension SK TU4-IOE TI 275271019 Ethernet/IP bus interface SK CU4-EIP
TI 275281156 IO extension SK TU4-IOE-C TI 275281119 Ethernet/IP bus interface SK TU4-EIP
TI 275281206 IO extension SK TU4-IOE-M12 TI 275281169 Ethernet/IP bus interface SK TU4-EIP-C
TI 275281256 IO extension SK TU4-IOE-M12-C TI 275271018 POWERLINK bus interface SK CU4-POL
TI 275271108 24 V power supply SK CU4-24V-123 TI 275281118 POWERLINK bus interface SK TU4-POL
TI 275271109 24 V power supply SK CU4-24V-140 TI 275281168 POWERLINK bus interface SK TU4-POL-C
TI 275281108 24 V power supply SK TU4-24V-123 TI 275271015 PROFINET bus interface SK CU4-PNT
TI 275281109 24 V power supply SK TU4-24V-140 TI 275281115 PROFINET bus interface SK TU4-PNT
TI 275281158 24 V power supply SK TU4-24V-123-C TI 275281165 PROFINET bus interface SK TU4-PNT-C
TI 275281159 24 V power supply SK TU4-24V-123-C TI 275281122 PROFINET bus interface SK TU4-PNT-M12
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275281172 PROFINET bus interface SK TU4-PNT-M12-C
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C TI 275281117 EtherCAT bus interface SK TU4-ECT
TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12 TI 275281167 EtherCAT bus interface SK TU4-ECT-C

TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274503 - 2414 5/5


Pos : 6 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-SYSM / 275274505/Basisi nformati onen [SK TIE4-M 12- SYSM] @ 4\mod_1391594196682_388.docx @ 115005 @ 5555 @ 1

SK TIE4-M12-SYSM Part number: 275 274 505


System bus output connection extension
M12 BUS system connector

Scope of delivery
1x M12 Socket connector SK TIE4-M12-SYSM
1x Cover cap blue
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the system bus
technology option to the outgoing field bus cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Blue / RAL 5012 Connector cover Blue / RAL 5012
Colour / Material plastic Colour / Material plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable Socket M16x1.5 *
Round plug connector connector with flexible strand Tightening torques *
M16x1.5, metric screw thread M12x1 Socket connector 0.6 Nm
M16x1.5 Screw thread 1.5 Nm
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl, bk, gr) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-SYSM


Connection extension TI 275274505 1.3 0217 EN
Connection extension – SK TIE4-M12-SYSM

Circuit diagram

Pos : 18 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction


Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.
Installation steps for installation of the M12 Receptable connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274505 - 0217


Connection extension – SK TIE4-M12-SYSM

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 22 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274505 - 0217 3/5


Connection extension – SK TIE4-M12-SYSM

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 29 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SYSM / 275274505/Ansc hlüss e [SK T IE4-M12-SYSM] @ 4\mod_1391594195878_388.doc x @ 114980 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 socket connector are connected to the
terminal strip of the BUS connection unit (technology box), the BUS customer interface or the control
terminal strip in the frequency inverter (see below).

Frequency inverter BUS connection unit BUS technology box


(SK TI4-TU-BUS (-C)) (SK TU4-… (-M12) / (-C))

Electrical connections

BUS technology box


Connection extension Connection terminals
SK TU4-… (-M12) / (-C)
M12 Socket connector SK 180E … 190E,
BUS connection unit
SK TIE4-M12-SYSM SK 2xxE
SK TI4-TU-BUS (-C)
Contact Pin * Colour * Signal Contact Designation Contact Designation
assignments 2 brown +24 V 43/44 ** +24 V 13 24 V
3 blue GND 40 0 V GND 17 0 V GND
4-pole
4 black CAN_H 77 SYS H 14 SYS +
Socket 5 grey CAN_L 78 SYS L 16 SYS -
connector **43: 24 V internal, SK 180E…SK 190E, SK 2x0E; 44: 24 V external, SK 2x5E
A - coded

*the colour assignments and the colour-pin assignments were different in the pilot series
Pin Colour Signal Contact Designation Contact Designation
2 red +24 V 43/44 ** +24 V 13 24 V
3 blue GND 40 0 V GND 17 0 V GND
4 black CAN_H 77 SYS H 14 SYS +
5 grey CAN_L 78 SYS L 16 SYS -

Pos : 40 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274505 - 0217


Connection extension – SK TIE4-M12-SYSM

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 46 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SYSM / 275274505/Weiterführ ende Dokumentationen [SK T IE4-M12-SYSM] @ 4\mod_1391594197434_388.doc x @ 115030 @ @ 1

Further documentation (www.nord.com)


Document Designation Document Designation
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12
BU 0200 Frequency inverter manual SK 2xxE
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C
TI 275280500 Bus connection unit SK TI4-TU-BUS-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271015 PROFINET IO bus interface SK CU4-PNT
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281115 PROFINET IO bus interface SK TU4-PNT
TI 275271001 CANopen bus interface SK CU4-CAO TI 275281165 PROFINET IO bus interface SK TU4-PNT-C
TI 275281101 CANopen bus interface SK TU4-CAO TI 275281122 PROFINET IO bus interface SK TU4-PNT-M12
TI 275281151 CANopen bus interface SK TU4-CAO-C TI 275281172 PROFINET IO bus interface SK TU4-PNT-M12-C
TI 275281201 CANopen bus interface SK TU4-CAO-M12 TI 275271018 POWERLINK bus interface SK CU4-POL
TI 275281251 CANopen bus interface SK TU4-CAO-M12-C TI 275281118 POWERLINK bus interface SK TU4-POL
TI 275271002 DeviceNet bus interface SK CU4-DEV TI 275281168 POWERLINK bus interface SK TU4-POL-C
TI 275281102 DeviceNet bus interface SK TU4-DEV TI 275271019 Ethernet/IP bus interface SK CU4-EIP
TI 275281152 DeviceNet bus interface SK TU4-DEV-C TI 275281119 Ethernet/IP bus interface SK TU4-EIP
TI 275281202 DeviceNet bus interface SK TU4-DEV-M12 TI 275281169 Ethernet/IP bus interface SK TU4-EIP-C
TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275281117 EtherCAT bus interface SK TU4-ECT
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR TI 275281167 EtherCAT bus interface SK TU4-ECT-C
TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C TI 275274506 Connection extension SK TIE4-M12-SYSS

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274505 - 0217 5/5


Pos : 7 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-SYSS / 275274506/Basisinfor mationen [SK TIE4-M12-SYSS] @ 4\mod_1392116958563_388.docx @ 117831 @ 5555 @ 1

SK TIE4-M12-SYSS Part number: 275 274 506


System bus input connection extension
M12 BUS system connector

Scope of delivery

1x M12 Plug connector SK TIE4-M12-SYSS


1x Cover cap blue
As-delivered status with screwed-on connector cover

Field of use
The M12 Plug connector has open cable ends and wire end sleeves. It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the system bus
technology option to the incoming field bus cable at the input side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Blue / RAL 5012 Connector cover Blue / RAL 5012
Colour / Material plastic Colour / Material plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable Plug M16x1.5 *
Round plug connector connector with flexible strand Tightening torques *
M16x1.5, metric screw thread M12x1 Plug connector 0.6 Nm
M16x1.5 Screw thread 1.5 Nm
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl, bk, gr) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-SYSS


Connection extension IT 275274506 1.3 0217 EN
Connection extension – SK TIE4-M12-SYSS

Circuit diagram

Pos : 18 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction


Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.
Installation steps for installation of the M12 Receptable connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 IT 275274506 - 0217


Connection extension – SK TIE4-M12-SYSS

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 22 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

IT 275274506 - 0217 3/5


Connection extension – SK TIE4-M12-SYSS

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 30 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SYSS / 275274506/Ans chl üss e [SK TIE4-M 12- SYSS] @ 4\mod_1392116957543_388.doc x @ 117806 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Plug connector are connected to the terminal
strip of the BUS connection unit (technology box), the BUS customer interface or the control terminal
strip in the frequency inverter or motor starter (see below).

Frequency inverter BUS connection unit BUS technology box


(SK TI4-TU-BUS (-C)) (SK TU4-… (-M12) / (-C))

Electrical connections

BUS technology box


Connection extension Connection terminals
SK TU4-… (-M12) / (-C)
M12 Plug connector SK 180E … 190E,
BUS connection unit
SK TIE4-M12-SYSS SK 2xxE
SK TI4-TU-BUS (-C)
Contact Pin * Colour * Signal Contact Designation Contact Designation
assignments 2 brown +24 V 43/44 ** +24 V 11 24 V
3 blue GND 40 0 V GND 15 0 V GND
4-pole
4 black CAN_H 77 SYS H 14 SYS +
Plug connector 5 grey CAN_L 78 SYS L 16 SYS -
A - coded ** 43: 24 V internal, SK 180E…SK 190E, SK 2x0E; 44: 24 V external, SK 2x5E

* the colour assignments and the colour-pin assignments were different in the pilot series
Pin Colour Signal Contact Designation Contact Designation
2 white +24 V 43/44 ** +24 V 11 24 V
3 blue GND 40 0 V GND 15 0 V GND
4 black CAN_H 77 SYS H 14 SYS +
5 grey CAN_L 78 SYS L 16 SYS -

Pos : 40 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 IT 275274506 - 0217


Connection extension – SK TIE4-M12-SYSS

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 47 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SYSS / 275274506/Weiter führende D okumentati onen [SK TIE4-M 12- SYSS] @ 4\mod_1392116959309_388.doc x @ 117856 @ @ 1

Further documentation (www.nord.com)


Document Designation Document Designation
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12
BU 0200 Frequency inverter manual SK 2xxE
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C
TI 275280500 Bus connection unit SK TI4-TU-BUS-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271015 PROFINET IO bus interface SK CU4-PNT
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281115 PROFINET IO bus interface SK TU4-PNT
TI 275271001 CANopen bus interface SK CU4-CAO TI 275281165 PROFINET IO bus interface SK TU4-PNT-C
TI 275281101 CANopen bus interface SK TU4-CAO TI 275281122 PROFINET IO bus interface SK TU4-PNT-M12
TI 275281151 CANopen bus interface SK TU4-CAO-C TI 275281172 PROFINET IO bus interface SK TU4-PNT-M12-C
TI 275281201 CANopen bus interface SK TU4-CAO-M12 TI 275271018 POWERLINK bus interface SK CU4-POL
TI 275281251 CANopen bus interface SK TU4-CAO-M12-C TI 275281118 POWERLINK bus interface SK TU4-POL
TI 275271002 DeviceNet bus interface SK CU4-DEV TI 275281168 POWERLINK bus interface SK TU4-POL-C
TI 275281102 DeviceNet bus interface SK TU4-DEV TI 275271019 Ethernet/IP bus interface SK CU4-EIP
TI 275281152 DeviceNet bus interface SK TU4-DEV-C TI 275281119 Ethernet/IP bus interface SK TU4-EIP
TI 275281202 DeviceNet bus interface SK TU4-DEV-M12 TI 275281169 Ethernet/IP bus interface SK TU4-EIP-C
TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275281117 EtherCAT bus interface SK TU4-ECT
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR TI 275281167 EtherCAT bus interface SK TU4-ECT-C
TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C TI 275274505 Connection extension SK TIE4-M12-SYSM

=== Ende der Liste für T extmar ke Inhalt ===

IT 275274506 - 0217 5/5


Pos : 8 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-POW / 275274507/Basisinfor mationen [SK T IE4-M12-POW] @ 4\mod_1392118233450_388.doc x @ 117906 @ 5555 @ 1

SK TIE4-M12-POW Part number: 275 274 507


24 V feed connection extension
M12 system connector

Scope of delivery

1x M12 Plug connector SK TIE4-M12-POW


1x Cover cap black
As-delivered status with screwed-on connector cover

Field of use
The M12 Plug connector has open cable ends and wire end sleeves. It is used to make a pluggable
connection using normal commercial M12 round plug connectors and for supplying the device or the
optional module with a 24 V DC supply voltage.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Black / RAL 9005 Connector cover Black / RAL 9005
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable Plug M16x1.5 *
Round plug connector connector with flexible Tightening torques *
strand
M12x1 Plug connector 0.6 Nm
M16x1.5, metric screw
M16x1.5 Screw thread 1.5 Nm
thread
Contact set 4 pin, A - coded
Contacts / Coding

* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 2 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-POW


Connection extension TI 275274507 V 1.2 0217 EN
Connection extension – SK TIE4-M12-POW

Circuit diagram

Pos : 18 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction


Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.
Installation steps for installation of the M12 Receptable connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274507 - 0217


Connection extension – SK TIE4-M12-POW

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 22 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274507 - 0217 3/5


Connection extension – SK TIE4-M12-POW

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 31 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-POW / 275274507/Ansc hlüsse [SK TIE4-M12-POW] @ 4\mod_1392117945955_388.doc x @ 117881 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Plug connector are connected to the terminal
strip of the BUS connection unit (technology box), the BUS customer interface or the control terminal
strip in the frequency inverter or motor starter (see below).

Frequency inverters BUS connection unit Technology box Customer interface


and motor starters SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C) SK CU4-…

Electrical connections

Connection
Connection BUS technology box
terminals* Customer
extension SK TU4-… (-M12) / (-C)
SK 1x5E, interface
M12 Plug connector BUS connection unit
SK 180E … SK 190E, SK CU4-…
SK TIE4-M12-POW SK TI4-TU-BUS (-C)
SK 2xxE

Pin Colour Signal Contact Designation Contact Designation Contact Designation


1 brown +24 V 44 24 V 11/12 24 V 44 +24 V
3 blue GND 40 GND 15/17 GND 40 GND Bus
For series SK 1xxE devices: Replace existing pin for terminal with 8 mm wire end sleeves, otherwise a secure contact cannot be
*
guaranteed over the long term.

Contact
assignments
2-pole
Plug connector
A - coded

Pos : 40 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 48 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-POW / 275274507/Weiterführ ende D okumentati onen [SK TIE4-M12-POW] @ 4\mod_1392118240501_388.doc x @ 117931 @ @ 1

4/5 TI 275274507 - 0217


Connection extension – SK TIE4-M12-POW

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0135 Motor starter manual SK 105E … SK 175E TI 275271001 CANopen bus interface SK CU4-CAO
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281101 CANopen bus interface SK TU4-CAO
BU 0200 Frequency inverter manual SK 2xxE TI 275281151 CANopen bus interface SK TU4-CAO-C
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281201 CANopen bus interface SK TU4-CAO-M12
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275281251 CANopen bus interface SK TU4-CAO-M12-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271002 DeviceNet bus interface SK CU4-DEV
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281102 DeviceNet bus interface SK TU4-DEV
TI 275271010 Electronic brake rectifier, SK CU4-MBR TI 275281152 DeviceNet bus interface SK TU4-DEV-C
TI 275271011 Setpoint converter, SK CU4-REL TI 275281202 DeviceNet bus interface SK TU4-DEV-M12
TI 275271006 IO extension SK CU4-IOE TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C
TI 275281106 IO extension SK TU4-IOE TI 275271019 Ethernet/IP bus interface SK CU4-EIP
TI 275281156 IO extension SK TU4-IOE-C TI 275281119 Ethernet/IP bus interface SK TU4-EIP
TI 275281206 IO extension SK TU4-IOE-M12 TI 275281169 Ethernet/IP bus interface SK TU4-EIP-C
TI 275281256 IO extension SK TU4-IOE-M12-C TI 275271018 POWERLINK bus interface SK CU4-POL
TI 275271108 24 V power supply SK CU4-24V-123 TI 275281118 POWERLINK bus interface SK TU4-POL
TI 275271109 24 V power supply SK CU4-24V-140 TI 275281168 POWERLINK bus interface SK TU4-POL-C
TI 275281108 24 V power supply SK TU4-24V-123 TI 275271015 PROFINET bus interface SK CU4-PNT
TI 275281109 24 V power supply SK TU4-24V-140 TI 275281115 PROFINET bus interface SK TU4-PNT
TI 275281158 24 V power supply SK TU4-24V-123-C TI 275281165 PROFINET bus interface SK TU4-PNT-C
TI 275281159 24 V power supply SK TU4-24V-123-C TI 275281122 PROFINET bus interface SK TU4-PNT-M12
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275281172 PROFINET bus interface SK TU4-PNT-M12-C
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C TI 275281117 EtherCAT bus interface SK TU4-ECT
TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12 TI 275281167 EtherCAT bus interface SK TU4-ECT-C

TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274507 - 0217 5/5


Pos : 9 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-ANA / 275274508/Basisinfor mationen [SK T IE4-M12-AN A] @ 4\mod_1391594203025_388.doc x @ 115080 @ 5555 @ 1

SK TIE4-M12-ANA Part number: 275 274 508


Connection extension for analogue initiators and
actuators
M12 system plug connector

Scope of delivery
1x M12 Socket connector SK TIE4-ANA
1x Cover cap white
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the technology option
with the outgoing connecting cable.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert White / RAL 9010 Connector cover White / RAL 9010
Colour / Material plastic Colour / Material plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Socket connector with Tightening torques *
flexible strand
M12x1 Socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, wt, bl, bk, rd) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-ANA


Connection extension TI 275274508 V 1.1 2414 EN
Connection extension – SK TIE4-M12-ANA

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274508 - 2414


Connection extension – SK TIE4-M12-ANA

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274508 - 2414 3/5


Connection extension – SK TIE4-M12-ANA

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 30 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-AN A / 275274508/Ans chl üss e [SK TIE4-M 12- ANA] @ 4\mod_1391594202355_388.doc x @ 115055 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the IOE connection unit (technology box), the IOE customer interface in the frequency
inverter or the connection terminals of the frequency inverter (see below).

Frequency inverter IOE technology box BUS customer interface


SK 180E … 190E SK TU4-IOE (-M12) / (-C) SK CU4-IOE
SK 2x0E BUS connection unit
Only performance stages with integrated power SK TI4-TU-BUS (-C)
supply

Electrical connections

Connection
Connection Technology box
extension Customer
terminals* SK TU4-IOE (-M12) / (-C)
M12 Socket interface
SK 180E … SK 190E, BUS connection unit
connector SK CU4-IOE
SK 2x0E SK TI4-TU-BUS (-C)
SK TIE4-M12-ANA
Pin Colour Signal Contact Designation Contact Designation
1 brown +24 V 11/12 24V 44 24 V
2 white AIN1+ / 2+ 3/4 AIN1+ / 2+ 14/16 AIN1+ / 2+
Initiators

3 blue GND 7/8 0 V-A 12 AGND


4 black AIN1- / 2- 5/6 AIN1- / 2- 13/15 AIN1- / 2-
Contact 5 red +10 V 1/2 10 V-A 11 10 V
assignments
5-pole Pin Colour Signal Contact Designation Contact Designation
Socket connector 1 brown +24 V 11/12 24V 44 24 V
Actuators

2 white AOUT 1 9 AOUT 17 AOUT


A - coded
3 blue AGND 7/8 0 V-A 12 AGND
4 black n. c. n. c. n. c. n. c. n. c.
5 red n. c. n. c. n. c. n. c. n. c.
* For series SK1x0E devices: Replace existing pin fork terminal with 8mm wire end sleeves, otherwise a secure contact
cannot be guaranteed over the long term.

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274508 - 2414


Connection extension – SK TIE4-M12-ANA

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 46 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-AN A / 275274508/Weiterführende D okumentati onen [SK TIE4-M 12- ANA] @ 4\mod_1391759505378_388.doc x @ 116611 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281156 IO extension SK TU4-IOE-C


BU 0200 Frequency inverter manual SK 2xxE TI 275281206 IO extension SK TU4-IOE-M12
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281256 IO extension SK TU4-IOE-M12-C
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275271108 24 V power supply SK CU4-24V-123
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271109 24 V power supply SK CU4-24V-140
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281108 24 V power supply SK TU4-24V-123
TI 275271010 Electronic brake rectifier, SK CU4-MBR TI 275281109 24 V power supply SK TU4-24V-140
TI 275271011 Setpoint converter, SK CU4-REL TI 275281158 24 V power supply SK TU4-24V-123-C
TI 275271006 IO extension SK CU4-IOE TI 275281159 24 V power supply SK TU4-24V-123-C
TI 275281106 IO extension SK TU4-IOE

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274508 - 2414 5/5


Technical Information / Datasheet
Pos : 10 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH / 275274509/Basisinfor mationen [SK TIE4-M12-SH ] @ 4\mod_1391594208067_388.doc x @ 115155 @ 5555 @ 1

SK TIE4-M12-SH Part number: 275 274 509


Connection extension "secure hold" output
M12 control system plug connector

Scope of delivery
1x M12 Socket connector SK TIE4-M12-SH
1x Cover cap yellow
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the control terminal strip
with the outgoing control signal cable at the output side.
Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 1021 Connector cover Yellow / RAL 1021
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
M16x1.5 *
Connection / Type M12x1, adjustable Tightening torques *
Round plug connector Socket connector with M12x1 Socket 0.6 Nm
flexible strand connector 1.5 Nm
M16x1.5, metric screw M16x1.5 Screw thread
thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 2 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (bl, bk) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-SH


1.1 Extensive revision 2414 Bch TI 27574509 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-SH

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptacle
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptacle connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/4 TI 27574509 - 2414


Connection extension – SK TIE4-M12-SH

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptacle connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptacle connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptacle connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptacle connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptacle connector and tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 27574509 - 2414 3/4


Connection extension – SK TIE4-M12-SH

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 31 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH / 275274509/Ansc hlüss e [SK T IE4-M12-SH] @ 4\mod_1391671681476_388.doc x @ 115551 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the control terminals in the frequency inverter (see below).

Frequency inverter BUS connection unit BUS technology box


SK 21xE, SK 23xE SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C)

Electrical connections

Connection extension Connection terminals


M12 Socket connector SK 21xE
SK TIE4-M12-SH SK 23xE

Pin Colour Signal Contact Designation


Contact assignments
3 blue GND SH 88 GND SH
2-pole
4 black +24 V SH 89 +24 V SH
Socket connector
A - coded

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 47 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH / 275274509/Weiterführ ende Dokumentationen [SK T IE4-M12-SH] @ 4\mod_1391594208722_388.doc x @ 115180 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0200 Frequency inverter manual SK 2xxE TI 275280500 Bus connection unit SK TI4-TU-BUS-C
BU 0230 Functional safety for SK 200E manual TI 275274510 Connection extension SK TIE4-M12-M16
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275274511 Connection reduction SK TIE4-M20-M16

=== Ende der Liste für T extmar ke Inhalt ===

4/4 TI 27574509 - 2414


Technical Information / Datasheet
Pos : 11 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L / 275274512/Basisi nfor mati onen [SK TIE4-M 12-HT L] @ 4\mod_1391594215736_388.doc x @ 115230 @ 5555 @ 1

SK TIE4-M12-HTL Part number: 275 274 512


HTL rotary encoder output connection extension
M12 system plug connector

Scope of delivery
1x M12 Socket connector SK TIE4-M12-HTL
1x Cover cap black
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the technology option
with the outgoing HTL rotary encoder cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Black / RAL 9005 Connector cover Black / RAL 9005
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Socket connector with Contacts / Coding 5 pin, A - coded
flexible strand
M16x1.5, metric screw Tightening torques *
thread M12x1 Socket 0.6 Nm
connector 1.5 Nm
Contact set 5 pin, B - coded
M16x1.5 Screw thread
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl, bk, wt) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-HTL


1.1 Extensive revision 2414 Bch TI 27527412 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-HTL

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 27527412 - 2414


Connection extension – SK TIE4-M12-HTL

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 27527412 - 2414 3/5


Connection extension – SK TIE4-M12-HTL

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 32 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L / 275274512/Ansc hlüs se [SK T IE4-M12-HTL] @ 4\mod_1391765971996_388.doc x @ 116641 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the control terminals in the frequency inverter (see below).

HTL rotary encoder Frequency inverter BUS technology box


SK 2xxE SK TU4-… (-M12) / -C)

Electrical connections

Connection extension
Connection terminals
M12 Socket connector
SK 2xxE
SK TIE4-M12-HTL

Contact Pin Colour Signal Contact Designation


assignments 1 brown 24 V 43/44* 24 V
2 white TRACK B 23 DIN3
4-pole
3 blue GND 40 GND
Socket
4 black TRACK A 22 DIN2
connector * 43: 24 V internal, SK 2x0E; 44: 24 V external, SK 2x5E
B-coded

Information Connection to digital inputs


The HTL rotary encoder can only be connected to DIN2 and DIN3 of the control terminal strip of the frequency
inverter. The digital inputs of the customer interfaces and technology assemblies cannot be used for rotary
encoders.
Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 27527412 - 2414


Connection extension – SK TIE4-M12-HTL

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 48 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L / 275274512/Weiterführ ende D okumentationen [SK T IE4-M12-HTL] @ 4\mod_1391767190241_388.doc x @ 116666 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0200 Frequency inverter manual SK 2xxE TI 275274511 Connection reduction SK TIE4-M20-M16


TI 275280000 Bus connection unit SK TI4-TU-BUS TI 18552090 Level adaptation PCB HTL - RS422
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 18552095 Level adaptation PCB HTL - HTL A+/- B+/-
TI 275274510 Connection extension SK TIE4-M12-M16

=== Ende der Liste für T extmar ke Inhalt ===

TI 27527412 - 2414 5/5


Pos : 13 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ASI- AUX / 275274513/Basisinfor mationen [SK T IE4-M12-ASI-AU X] @ 4\mod_1392023252331_388.doc x @ 117323 @ 5555 @ 1

SK TIE4-M12-ASI-AUX Part number: 275 274 513


AS interface with auxiliary power connection extension
M12 BUS system connector

Scope of delivery

1x M12 Plug connector SK TIE4-M12-ASI-AUX


1x Cover cap yellow
As-delivered status with screwed-on connector cover

Field of use
The M12 Plug connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the AS Interface
technology option with the incoming AS Interface field bus cable at the input side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Yellow / RAL 1018 Connector cover Yellow / RAL 1018
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
M16x1.5 *
Connection / Type M12x1, adjustable Plug
Round plug connector connector with flexible Tightening torques *
strand
M12x1 Socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set 5 pin, A - coded
Contacts / Coding

* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, bl) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-ASI-AUX


Connection extension TI 275274513 V 1.2 4214 EN
Connection extension – SK TIE4-M12-ASI-AUX

Circuit diagram

os: 17 /T ec hni sche Infor mationen/Ansc hlus ser weiter ung en [H AN, H Q,SK TIE]/Stec kverbi nder [H AN, HQ, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder /Allgemeingül tig/Montage- / Options plätz e [SK TIE4-M 12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector

1. Remove M16 blind plug at the provided option location side


(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/4 TI 275274513 - 4214


Connection extension – SK TIE4-M12-ASI-AUX

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274513 - 4214 3/4


Connection extension – SK TIE4-M12-ASI-AUX

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 34 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ASI- AUX / 275274513/Anschl üss e [SK TIE4-M12-ASI-AU X] @ 4\mod_1392023251112_388.doc x @ 117298 @ 55 @ 1

Connections
The open cable ends of the extension / M12 Plug connector are connected to the terminal strip of the
BUS connection unit (technology box), the BUS customer interface or the control terminal strip in the
frequency inverter or the motor starter (see below).

Frequency inverter BUS connection unit BUS technology box


and motor starter SK TI4-TU-BUS (-C) (SK TU4-… (-M12) / (-C)

Electrical connections

Connecting terminals
Connection extension SK 1x5E (set jumper
M12 Plug connector position at device)
SK TIE4-M12-ASI-AUX
SK 22xE/ 23xE-…-AxB
Contact Pin Colour Signal Contact Designation
assignments 1 brown ASI + 84 ASI +
2 white GND 40 GND
4-pole
3 blue ASI - 85 ASI -
Plug connector 4 black +24 V 44 +24 V
A-coded

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 50 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ASI- AUX / 275274513/Weiterführende Dokumentati onen [SK TIE4-M12-ASI-AU X] @ 4\mod_1392023253655_388.doc x @ 117348 @ 5 @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0090 AS interface (SK 300E … SK 750E) TI 275280500 Bus connection unit SK TI4-TU-BUS-C
BU 0135 Motor starter manual SK 105E … SK 175E TI 275274510 Connection extension SK TIE4-M12-M16
BU 0200 Frequency inverter manual SK 2xxE TI 275274511 Connection reduction SK TIE4-M20-M16
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275274502 Connection extension SK TIE4-M12-ASI

=== Ende der Liste für T extmar ke Inhalt ===

4/4 TI 275274513 - 4214


Pos : 12 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ETH / 275274514/Basisinfor mati onen [SK TIE4-M12-ETH] @ 4\mod_1391594327899_388.doc x @ 115305 @ 5555 @ 1

SK TIE4-M12-ETH Part number: 275 274 514


Ethernet output connection extension
M12 BUS system connector

Scope of delivery
1x M12 Socket connector SK TIE4-M12-ETH
1x Cover cap green
Delivery status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the Ethernet technology
options with the outgoing Ethernet field bus cable at the output side.

Technical data

Design
Temperature range -30 … +90 °C Weight 23 g
Contact insert green Connector cover green
Colour / Material plastic Colour / Material plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Socket connector with Tightening torques *
flexible strand
M12x1 Socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 4 x 0.34 mm Mech. service life: min. 100 plugging cycles
Cross section
Wire strands / colours UL / (ye, wt, or, bl) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Technical Information / Datasheet SK TIE4-M12-ETH


Connection extension TI 275274514 V 1.0 2414 EN
Connection extension – SK TIE4-M12-ETH

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274514 - 2414


Connection extension – SK TIE4-M12-ETH

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274514 - 2414 3/5


Connection extension – SK TIE4-M12-ETH

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 33 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ETH / 275274514/Ansc hlüs se [SK T IE4-M12-ETH ] @ 4\mod_1391594327119_388.doc x @ 115280 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the BUS customer interface in the frequency inverter (see below).

Information Connection to technology box


An M12 Socket connector can only be connected to Ethernet-based BUS customer interfaces. The field bus is
always connected to the BUS technology boxes at the front via one or both of the integrated M12 Male socket
connectors.

Frequency inverter BUS technology boxes BUS customer interfaces


SK 2xxE SK TU4-… (-C) SK CU4-…
see information above Ethernet-based options

Electrical connections

Connection extension BUS customer interfaces


M12 Socket connector SK CU4-ECT, SK CU4-POL,
SK TIE4-M12-ETH SK CU4-EIP, SK CU4-PNT

Contact Pin Colour Signal Contact Designation


1 yellow E1 / E5 Transmission Data +
assignments TX +
2 white RX + E3 / E7 Receive Data +
4-pole
3 orange TX - E2 / E6 Transmission Data -
Socket 4 blue RX - E4 / E8 Receive Data -
connector E1 – E4 incoming
D - coded E5 – E8 outgoing

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274514 - 2414


Connection extension – SK TIE4-M12-ETH

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 49 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-ETH / 275274514/Weiterführ ende D okumentationen [SK T IE4-M12-ETH ] @ 4\mod_1391594328560_388.doc x @ 115330 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275274511 Connection reduction SK TIE4-M20-M16
BU 0200 Frequency inverter manual SK 2xxE TI 275271019 Ethernet/IP bus interface SK CU4-EIP
BU 0270 EtherCAT for SK 2xxE manual TI 275271018 POWERLINK bus interface SK CU4-POL
BU 2100 EtherNet/IP™ for SK 2xxE manual TI 275271015 PROFINET bus interface SK CU4-PNT
BU 2200 POWERLINK for SK 2xxE manual TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275274510 Connection extension SK TIE4-M12-M16

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274514 - 2414 5/5


Technical Information / Datasheet
Pos : 2 /T ec hnis che Infor mationen/Ansc hluss er weiter ung en [HAN , H Q,SK T IE]/Stec kverbi nder [H AN, H Q, SK TIE]/M12 Steuersignal- und Buss ystem- Stec kver binder/SK TIE4-M12-CAO- OUT / 275274515 /Basisi nfor mati onen [SK TIE4-M12-CAO- OUT] @ 4\mod_1378827072687_388.doc x @ 94458 @ 5555 @ 1

SK TIE4-M12-CAO-OUT Part number: 275 274 515


CANopen output connection extension
M12 BUS system connector

Scope of delivery

1x M12 Socket connector SK TIE4-M12-CAO-OUT


1x Cover cap grey
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the CANopen
technology option with the outgoing CANopen field bus cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 7042 Connector cover Grey / RAL 7042
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Socket connector with Tightening torques *
flexible strand
M12x1 Male socket 0.6 Nm
M16x1.5, metric screw connector 1.5 Nm
thread
M16x1.5 Screw thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (wt, br, bl, bk, gr) Operating voltage max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Connection extension SK TIE4-M12-CAO-OUT


1.0 First Version 2414 Bch TI 275274515 EN

version reason for change(s) issue name document speech


Connection extension – SK TIE4-M12-CAO-OUT

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/5 TI 275274515 - 2414


Connection extension – SK TIE4-M12-CAO-OUT

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

TI 275274515 - 2414 3/5


Connection extension – SK TIE4-M12-CAO-OUT

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-CAO-OUT / 275274515 /Ansc hlüs se [SK T IE4-M12-CAO-OUT] @ 4\mod_1378827070308_388.doc x @ 94408 @ 55 @ 1

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the BUS connection unit (technology box) or the BUS customer interface in the
frequency inverter (see below).

BUS connection unit BUS technology box BUS customer interface


SK TI4-TU-BUS (-C) SK TU4-CAO (-M12) /( -C) SK CU4-CAO

Electrical connections

BUS technology box


Connection extension
SK TU4-CAO (-M12) / (-C) BUS customer interface
M12 Socket connector
BUS connection unit SK CU4-CAO
K TIE4-M12-CAO-OUT
SK TI4-TU-BUS (-C)
Contact Pin Colour Signal Contact Designation Contact Designation
assignments 1 white Shield 9 SHLD 90 SHLD
2 brown +24 V 2 24V-B CAO 45 24V Bus
5-pole
3 blue GND 8 GND B CAO 46 GND Bus
Socket 4 black CAN_H 4 CAO+ OUT 75 (outgoing) CANopen+
connector 5 grey CAN_L 6 CAO- OUT 76 (outgoing) CANopen-
A - coded

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

4/5 TI 275274515 - 2414


Connection extension – SK TIE4-M12-CAO-OUT

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 39 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-CAO-OUT / 275274515 /Weiterführ ende D okumentationen [SK T IE4-M12-CAO-OUT] @ 4\mod_1381136157175_388.doc x @ 100651 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281151 CANopen – bus interface SK TU4-CAO-C
BU 0200 Frequency inverter manual SK 2xxE TI 275281201 CANopen – bus interface SK TU4-CAO-M12
BU 0260 Manual CANopen for SK 200E TI 275281251 CANopen – bus interface SK TU4-CAO-M12-C
BU 0280 Manual DEVICENET for SK 200E TI 275271002 DeviceNet – bus interface SK CU4-DEV
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281102 DeviceNet – bus interface SK TU4-DEV
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275281152 DeviceNet – bus interface SK TU4-DEV-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275281202 DeviceNet – bus interface SK TU4-DEV-M12
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281252 DeviceNet – bus interface SK TU4-DEV-M12-C
TI 275271001 CANopen – bus interface SK CU4-CAO TI 275274501 Connection extension SK TIE4-M12-CAO
TI 275281101 CANopen – bus interface SK TU4-CAO

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274515 - 2414 5/5


Pos : 14 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN P / 275274516/Basisi nformati onen [SK TIE4-M 12-IN P] @ 4\mod_1392986112988_388.doc x @ 119648 @ 5555 @ 1

SK TIE4-M12-INP Part number: 275 274 516


Connection extension for initiators and 24 V
M12 control system connector

Scope of delivery
1x M12 plug connector SK TIE4-M12-INP
1x Cover cap black
As-delivered status with screwed-on connector cover

Usage area
The M12 plug connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the technology option
and the control terminal strip with the outgoing control signal cable at the input side.

Information Connecting variants


The three "variably" used connecting cables (IN 1, IN 2 und IN 3) can be used differently depending on the
application (e.g. 24 V feeds, digital inputs etc.). More information can be found in the associated customer
specification.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Black / RAL 9005 Connector cover Black / RAL 9005
Colour / Material Plastic Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable plug M16x1.5 *
Round plug connector connector with flexible Tightening torques *
strand
M12x1 Plug connector 0.6 Nm
M16x1.5, metric screw
M16x1.5 Screw thread 1.5 Nm
thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life min. 100 plugging cycles

Technical Information / Datasheet SK TIE4-M12-INP


Connection extension TI 275274516 V 1.0 2414 EN
Connection extension – SK TIE4-M12-INP

Cross section
Wire strands / colours UL / (br, wt, bl, bk, rd) Operating voltage max. 250 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Circuit diagram

Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series, e.g. the SK TIE-M12-SH Plug connector cannot be installed with the SK 1xxE housing.
** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation
*** With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Plug connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

2/6 TI 275274516 - 2414


Connection extension – SK TIE4-M12-INP

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

TI 275274516 - 2414 3/6


Connection extension – SK TIE4-M12-INP

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 21 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 35 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN P / 275274516/Ansc hlüsse [SK TIE4-M12-IN P] @ 4\mod_1392986106882_388.doc x @ 119603 @ 55 @ 1

4/6 TI 275274516 - 2414


Connection extension – SK TIE4-M12-INP

Connections
The open cable ends of the connection extension / M12 panel connector are connected to the terminal
strip of the BUS connection unit (technology box), the BUS customer interface or the control terminal
strip in the frequency inverter or motor starter (see below).

Frequency inverter BUS connection unit Technology box BUS customer interface
and motor starter SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C) SK CU4-...

Electrical connections

Connection Connection terminals* Technology box


Customer
extension SK 1x5E, SK TU4-… (-M12) / (-C)
interface
M12 panel connector SK 180E…SK 190E, Connection unit
SK CU4-…
SK TIE4-M12-IMP SK 2xxE SK TI4-TU-BUS (-C)

Pin Colour Signal Contact Designation Contact Designation Contact Designation


1 brown +24 V 43/44 ** 24 V 11/12 24 V 44 +24 V
2 white IN 2 as required as required as required
Initiators

3 blue GND 40 GND 15/17 GND 40 GND Bus


4 black IN 1 as required as required as required
5 gr IN 3 as required as required as required
* For series SK1xxE devices: Replace existing pin fork terminal with 8mm wire end sleeves, otherwise a secure contact cannot be guaranteed
over the long term.
** 43: 24 V internal, SK 2x0E; 44: 24 V external, SK 2x5E

Contact
assignments
5-pole
Panel connector
A - coded

Pos : 37 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 51 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN P / 275274516/Weiterführ ende D okumentati onen [SK TIE4-M12-IN P] @ 4\mod_1392986117710_388.doc x @ 119673 @ @ 1

TI 275274516 - 2414 5/6


Connection extension – SK TIE4-M12-INP

Further documentation (www.nord.com)

Document Name Document Name

BU 0135 Motor starter manual SK 105E … SK 175E TI 275271001 CANopen bus interface SK CU4-CAO
BU 0180 Frequency inverter manual SK 180E, SK 190E TI 275281101 CANopen bus interface SK TU4-CAO
BU 0200 SK 2xxE frequency inverter manual TI 275281151 CANopen bus interface SK TU4-CAO-C
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275281201 CANopen bus interface SK TU4-CAO-M12
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 275281251 CANopen bus interface SK TU4-CAO-M12-C
TI 275274510 Connection extension SK TIE4-M12-M16 TI 275271002 DeviceNet bus interface SK CU4-DEV
TI 275274511 Connection reduction SK TIE4-M20-M16 TI 275281102 DeviceNet bus interface SK TU4-DEV
TI 275271010 Electronic brake rectifier, SK CU4-MBR TI 275281152 DeviceNet bus interface SK TU4-DEV-C
TI 275271011 Setpoint converter, SK CU4-REL TI 275281202 DeviceNet bus interface SK TU4-DEV-M12
TI 275271006 IO extension SK CU4-IOE TI 275281252 DeviceNet bus interface SK TU4-DEV-M12-C
TI 275281106 IO extension SK TU4-IOE TI 275271019 Ethernet/IP bus interface SK CU4-EIP
TI 275281156 IO extension SK TU4-IOE-C TI 275281119 Ethernet/IP bus interface SK TU4-EIP
TI 275281206 IO extension SK TU4-IOE-M12 TI 275281169 Ethernet/IP bus interface SK TU4-EIP-C
TI 275281256 IO extension SK TU4-IOE-M12-C TI 275271018 POWERLINK bus interface SK CU4-POL
TI 275271108 24 V power supply SK CU4-24V-123 TI 275281118 POWERLINK bus interface SK TU4-POL
TI 275271109 24 V power supply SK CU4-24V-140 TI 275281168 POWERLINK bus interface SK TU4-POL-C
TI 275281108 24 V power supply SK TU4-24V-123 TI 275271015 PROFINET bus interface SK CU4-PNT
TI 275281109 24 V power supply SK TU4-24V-140 TI 275281115 PROFINET bus interface SK TU4-PNT
TI 275281158 24 V power supply SK TU4-24V-123-C TI 275281165 PROFINET bus interface SK TU4-PNT-C
TI 275281159 24 V power supply SK TU4-24V-123-C TI 275281122 PROFINET bus interface SK TU4-PNT-M12
TI 275271000 PROFIBUS DP bus interface SK CU4-PBR TI 275281172 PROFINET bus interface SK TU4-PNT-M12-C
TI 275281000 PROFIBUS DP bus interface SK TU4-PBR TI 275271017 EtherCAT bus interface SK CU4-ECT
TI 275281150 PROFIBUS DP bus interface SK TU4-PBR-C TI 275281117 EtherCAT bus interface SK TU4-ECT
TI 275281200 PROFIBUS DP bus interface SK TU4-PBR-M12 TI 275281167 EtherCAT bus interface SK TU4-ECT-C

TI 275281250 PROFIBUS DP bus interface SK TU4-PBR-M12-C

=== Ende der Liste für T extmar ke Inhalt ===

6/6 TI 275274516 - 2414


Pos : 17 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN I-1M / 275274517/Basisi nformati onen [SK TIE4-M 12- INI-1M ] @ 6\mod_1426609139039_388.doc x @ 209150 @ 5555 @ 1

SK TIE4-M12-INI Part number: 275 274 517


Connection extension for initiators and actuators
M12 control system connector

Scope of delivery
1x M12 cable connector SK TIE4-M12-INI-1M

Field of use
The M12 cable connector has open cable ends (1m) and wire end sleeves. It is used to make a
pluggable connection using normal commercial M12 round plug connectors. The connection is via a
standard cable entry. It connects the technology option with the outgoing control signal cable at the
output side.

Technical data

Version
Temperature range -25 … +80 °C Weight 35 g
Contact insert green / RAL 6018 Cabel / cable sheath AWG 22 Black / PUR
Colour / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Separate cable entry
Connection / Type M12x1,
Round plug connector Socket connector with Tightening torques
flexible strand M12x1 Socket 0.6 Nm

Contact set 5 pin, A - coded


Contacts / Coding

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life min. 100 plugging cycles
Cross section
Wire strands / colours UL / (br, wt, bl, bk, Operating voltage max. 125 V AC/DC
gn/ye)
Length of wire strands 1000 mm Current rating 4A
Degree of fouling 3 Rated impulse voltage 1.5 kV

Technical Information / Datasheet SK TIE4-M12-INI-1M


Connection extension TI 275274517 V 1.0 1515 EN
Connection extension – SK TIE4-M12-INI-1M

Graphic illustration

Pos : 19 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...- 1M] @ 6\mod_1428501543235_388.doc x @ 211863 @ 5 @ 1

Installation / option locations


The cable connectors are to be mounted in a free fitting of the following series of devices via a suitable
cable entry (not included).

Device series Recommended option Option locations


location
SK 135E
SK 180E … SK 190E 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional
SK TI4-TU-BUS (-C) 5R / 5L
Pos : 22 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 38 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-IN I-1M / 275274517/Ansc hl üss e [SK TIE4-M 12-IN I-1M] @ 6\mod_1426609135376_388.doc x @ 209118 @ 55 @ 1

2/3 TI 275274517 - 1515


Connection extension – SK TIE4-M12-INI-1M

Connections
The open cable ends of the connection extension are connected to the terminal strip of the BUS
connection unit (technology box), the customer interface or the control terminal strip in the frequency
inverter or motor starter (see below).

Frequency inverter BUS connection unit Technology box Customer interface


and motor starter SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C) SK CU4-…

Electrical connections

Connection Connection
Technology box
extension terminals*** Customer
SK TU4-… (-M12) / (-C)
M12 Socket SK 1x5E, interface
Connection unit
connector SK 180E … SK 190E, SK CU4-…
SK TI4-TU-BUS (-C)
SK TIE4-M12-INI-1M SK 2xxE

Pin Colour Signal Contact Designation Contact Designation Contact Designation


1 brown +24 V 43/44 ** 24 V 11/12 24 V 44 +24 V
Initiators

2 white DIN 1-4 21-24 DIN1-4 19/20/25/26 DIN 1-4 C1/C2 DIN 1-4
3 blue GND 40 GND 15/17 GND 40 GND Bus
4 black DIN 1-4 21-24 DIN 1-4 19/20/25/26 DIN 1-4 C1/C2 DIN 1-4
5 gn/ye nc.

Pin Colour Signal Contact Designation Contact Designation Contact Designation


1 brown +24 V 43 +24 V 44 24 V 31/32 24 V
Actuators*

2 white DOUT 1 1 DOUT 1 1 DOUT 1 33 DOUT 1


3 blue GND 40 GND 40 GND 35/36 0V
4 black DOUT 2 3 DOUT 2 3 DOUT 2 34 DOUT 2
5 gn/ye nc.
* Only possible with series SK 2x0E devices
** 43: 24 V internal, SK 2x0E; 44: 24 V external, SK 2x5E
*** For series SK1xxE devices: Replace existing pin fork terminals with 8 mm wire end sleeves, otherwise secure contact cannot be guaranteed
over the long term.
Contact
assignments
5-pole
Socket
connector
A - coded

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274517 - 1515 3/3


Pos : 11 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH- IN / 275274519/Basisinfor mati onen [SK TIE4-M12-SH- IN] @ 17\mod_1491295194396_388.doc x @ 2337836 @ 5555 @ 1

SK TIE4-M12-SH-IN Part number: 275 274 519


Connection extension "Safe Stop" input
M12 control system plug connector

Scope of supply
1x M12 Socket connector SK TIE4-M12-SH-IN
1x Cover cap yellow
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the control terminal strip
with the outgoing control signal cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 1021 Connector cover Yellow / RAL 1021
Color / Material Plastic Color / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
M16x1.5 *
Connection / Type M12x1, adjustable Tightening torques *
Round plug connector Socket connector with M12x1 Socket 0.6 Nm
flexible strand connector 1.5 Nm
M16x1.5, metric screw M16x1.5 Screw thread
thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Technical Information / Datasheet SK TIE4-M12-SH-IN


Connection extension TI 275274519 V 1.0 1417 EN
Connection extension – SK TIE4-M12-SH-IN

Cable
2
Number of conductors / 2 x 0.34 mm Mech. Service life Min. 100 plugging cycles
Cross section
Wire strands / colors UL / (bl, sw) Operating voltage Max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Circuit diagram

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L

* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series,
e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

2/5 TI 275274519 - 1417


Connection extension – SK TIE4-M12-SH-IN

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

TI 275274519 - 1417 3/5


Connection extension – SK TIE4-M12-SH-IN

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 24 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 25 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 36 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH- IN / 275274519/Ansc hlüs se [SK T IE4-M12-SH-IN ] @ 17\mod_1491295192943_388.doc x @ 2337799 @ 55 @ 1

4/5 TI 275274519 - 1417


Connection extension – SK TIE4-M12-SH-IN

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the control terminals in the frequency inverter (see below).

Frequency inverter BUS connection unit BUS technology box


NORDAC FLEX SK TI4-TU-BUS (-C) SK TU4-… (-M12) / (-C)

Electrical connections

Connection extension Connection terminals


M12 Male connector NORDAC FLEX
SK TIE4-M12-SH SK 21xE, SK 23xE

Contact Pin Colour Signal Contact Designation


assignments 3 blue GND SH 88 GND SH
4 black +24 V SH 89 +24 V SH
2-pole
Male connector
A - coded

Pos : 44 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 55 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-SH- IN / 275274519/Weiterführ ende D okumentationen [SK T IE4-M12-SH-IN ] @ 17\mod_1491295194905_388.doc x @ 2337875 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0200 Frequency inverter manual SK 2xxE TI 275280500 Bus connection unit SK TI4-TU-BUS-C
BU 0230 Functional safety for SK 200E manual TI 275274510 Connection extension SK TIE4-M12-M16
TI 275280000 Bus connection unit SK TI4-TU-BUS TI 275274511 Connection reduction SK TIE4-M20-M16

=== Ende der Liste für T extmar ke Inhalt ===

TI 275274519 - 1417 5/5


Pos : 13 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L-A0 / 275274522/Basisinfor mati onen [SK TIE4-M 12-HT L-A0] @ 17\mod_1490360552036_388.doc x @ 2336466 @ 5555 @ 1

SK TIE4–M12–HTL–A0 Part number: 275 274 522


HTL rotary encoder output connection extension
M12 system plug connector for synchronous motors

Scope of supply
1x M12 Socket connector SK TIE4-M12-HTL-A0
1x Cover cap black
As-delivered status with screwed-on connector cover

Field of use
The 5-pole M12 Socket connector has open cable ends and wire end sleeves. It is used to make a
pluggable connection using normal commercial M12 round plug connectors. It connects the
technology option with the outgoing HTL rotary encoder cable at the output side. This connection is
mandatory for using of synchronous motors with encoder and M12 plug connector.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Black / RAL 9005 Connector cover Black / RAL 9005
Color / Material Plastic Color / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
Connection / Type M12x1, adjustable M16x1.5 *
Round plug connector Female connector with Contacts / Coding 5 pin, A - coded
flexible strand
M16x1.5, metric screw Tightening torques *
thread M12x1 Socket 0.6 Nm
connector 1.5 Nm
Contact set 5 pin, A - coded
M16x1.5 Screw thread
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Technical Information / Datasheet SK TIE4-M12-HTL-A0


Connection extension TI 275274522 V 1.0 1417 EN
Connection extension – SK TIE4-M12-HTL-A0

Cable
2
Number of conductors / 5 x 0.34 mm Mech. Service life Min. 100 plugging cycles
Cross section
Wire strands / colors UL / (br, bl, bk, wt, gr) Operating voltage Max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω

Circuit diagram

Pos : 20 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontage- / Optionspl ätz e [SK T IE4-M12-...] @ 4\mod_1381740109805_388.doc x @ 102041 @ 5 @ 1

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device series (see below).

Device series Recommended option Option locations


location
SK 135E *
SK 180E * … SK 190E * 4R / 4L (incoming)
Housing 5R / 5L (outgoing)
SK 1xxE xxx-xxx-x (-C))

SK 200E 4R / 4L (incoming)
Frequency inverter 5R / 5L (outgoing)
connecting unit optional **
SK TI4-x-2xx-x (-C) 6R / 6L, 7R / 7L, 8R / 8L

BUS technology box 1/2/3/4


BUS connection unit optional ***
SK TI4-TU-BUS (-C) 5R / 5L
* The configuration capability of the respective Receptacle connector depends on its functionality with regard to the device
series,
e.g. the SK TIE-M12-SH Socket connector cannot be installed with the SK 1xxE housing.

** Size 1 – 3 with optional SK TIE4-M12-M16 connection extension, size 4 direct installation

*** With optional SK TIE4-M20-M16 connection reduction

Pos : 23 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/M ontageschritte [SK T IE4-M12-...] @ 4\mod_1381747425031_388.doc x @ 102300 @ @ 1

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 6) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the housing and in the frequency inverter connecting unit or the BUS connecting unit of
an external technology box.

2/5 TI 275274522 - 1417


Connection extension – SK TIE4-M12-HTL-A0

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug at the provided option location side
(right / left) of the starter or frequency inverter housing or the
connection unit.

Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection extension SK TIE4-M12-M16
The M12 Receptable connector can alternatively be installed with an
optional M12-M16 connection extension.
First screw the M12 Receptable connector directly into the
connection extension and then fit into the M12 threaded opening in
the connection unit. For more information see Optional accessories

Connection reduction SK TIE4-M20-M16


The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit. For more information see Optional
accessories

TI 275274522 - 1417 3/5


Connection extension – SK TIE4-M12-HTL-A0

5. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

6. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

7. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

Pos : 24 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Achtung Korosion [SK TIE4-M 12-...] @ 4\mod_1381218166477_388.doc x @ 101021 @ @ 1

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.
Pos : 25 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/Allgemei ngültig/Drehmoment- M ontag esc hlüss el M 12 SW 17 [SK TIE4-M 12- ...] @ 4\mod_1381146245469_388.doc x @ 100937 @ @ 1

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).
Pos : 38 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L-A0 / 275274522/Ansc hlüs se [SK T IE4-M12-HTL- A0] @ 17\mod_1490360550936_388.doc x @ 2336429 @ 55 @ 1

4/5 TI 275274522 - 1417


Connection extension – SK TIE4-M12-HTL-A0

Connections
The open cable ends of the connection extension / M12 Socket connector are connected to the
terminal strip of the control terminals in the frequency inverter (see below).

HTL rotary encoder Frequency inverter Frequency inverter


NORDAC FLEX NORDAC LINK

Electrical connections

Connection terminals
Connection extension Connection terminals
NORDAC LINK
M12 Socket connector NORDAC FLEX
SK TIE4-M12-HTL-A0 SK 2xxE Internally wired (factory fitted)

Contact Pin Colour Signal Contact Designation Signal / Designation


assignments 1 brown 24 V 43/44* 24 V 24 V
2 white Track-B 23 DIN3 Track-B DIN3
5-pole
3 blue GND 40 GND GND
Socket 4 black Track-A 22 DIN2 Track-A DIN2
connector 5 grey Track-0 21 DIN1 Track-0 DIN1
A-coded * 43: 24 V internal, SK 2x0E; 44: 24 V external, SK 2x5E

Information Connection to digital inputs


The HTL rotary encoder (Track-A and Track-B) can only be connected to DIN2 and DIN3 of the control terminal
strip of the frequency inverter. The Track-0 must be connected to DIN1.
The digital inputs of the customer interfaces and technology assemblies cannot be used for rotary encoders.
Pos : 44 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-... Optional es Z ubehör/Opti onales Z ubehör [SK TIE4-...] @ 4\mod_1380629188419_388.doc x @ 100572 @ 5 @ 1

Optional accessories

Information M12 / M20 screw openings


Conductive connection extensions made from brass SK TIE4-M12-M16
from M12 to M16 or connection reductions SK TIE4-M20-M16 from M20 to
M16 are optionally available for installing the M12 connection extensions
in an M12 or M20 screw opening. For more information, see further
documentation.
Pos : 57 /T echnisc he Informati onen/Ans chl uss er weiterungen [HAN, HQ,SK TIE]/Stec kver binder [HAN , H Q, SK TIE]/M 12 Steuersignal- und Buss ys tem- Stec kverbi nder/SK TIE4-M 12-HT L-A0 / 275274522/Weiterführ ende D okumentationen [SK T IE4-M12-HTL- A0] @ 17\mod_1490360552663_388.doc x @ 2336505 @ @ 1

Further documentation (www.nord.com)

Document Designation Document Designation

BU 0200 Frequency inverter manual SK 2xxE TI 275274511 Connection reduction SK TIE4-M20-M16


TI 275280000 Bus connection unit SK TI4-TU-BUS TI 18552090 Level adaptation PCB HTL - RS422
TI 275280500 Bus connection unit SK TI4-TU-BUS-C TI 18552095 Level adaptation PCB HTL - HTL A+/- B+/-
TI 275274510 Connection extension SK TIE4-M12-M16
=== Ende der Liste für T extmar ke Inhalt ===

TI 275274522 - 1417 5/5


Getriebebau NORD GmbH & Co. KG
Getriebebau-Nord-Straße 1 • 22941 Bargteheide, Germany • www.nord.com

SK TIE4-M12-INS Part number: 275 274 531


Connection extension "Safe inputs”
M12 control system plug connector

Scope of supply

1x M12 Socket connector SK TIE4-M12-INS


1x Cover cap yellow
1x Insulating hose l = 240 mm, d = 5.0 mm
As-delivered status with screwed-on connector cover

Field of use
The M12 Socket connector has open cable ends and wire end sleeves It is used to make a pluggable
connection using normal commercial M12 round plug connectors. It connects the control terminal strip
with the outgoing control signal cable at the output side.

Technical data

Version
Temperature range -30 … +90 °C Weight 23 g
Contact insert Grey / RAL 1021 Connector cover Yellow / RAL 1021
Color / Material Plastic Color / Material Plastic
Round plug connector Metal, CuZn, Protection class IP67
Material nickel plated (screwed)
Fastening Hexagonal nut
M16x1.5 *
Connection / Type M12x1, adjustable Tightening torques *
Round plug connector Socket connector with M12x1 Socket 0.6 Nm
flexible strand connector 1.5 Nm
M16x1.5, metric screw M16x1.5 Screw thread
thread
Contact set 5 pin, A - coded
Contacts / Coding
* Suitable assembly spanner commercially available (see Installation)

Technical Information / Datasheet SK TIE4-M12-INS


Connection extension TI 275274531 V 1.0 1318 en
Connection extension – SK TIE4-M12-INS

1)
Cable
2
Number of conductors / 4 x 0.34 mm Mech. Service life Min. 100 plugging cycles
Cross section
1)
Wire strands / colors UL / (bn, wh, bk, gy) Operating voltage Max. 60 V
Length of wire strands 250 mm Current rating 4A
8
Degree of fouling 3/2 Insulation resistance ≥ 10 Ω
1) AWM Style 1007/1569 80/105 °C 300 V

Circuit diagram

Installation / option locations


The M12 Receptacle connector are intended for direct installation in a free M16 hole / threaded
opening of the device (see below).

Device series Recommended option Option locations


location
BUS technology box
(SAFE) 1/2/3/4
BUS connection unit optional *
(SAFE) 5R / 5L
SK TI4-TU-SAFE (-C)
* With optional SK TIE4-M20-M16 connection reduction

The installation position and mounting location (coding pin or coding groove on contact carrier) of the
Socket connector is freely positionable and should be aligned (see installation step 7) such that angled
M12 round connectors can also be connected in a way that avoids collisions.
The installation steps described in the following apply to the installation of the M12 Receptable
connectors in the BUS connecting unit (SAFE) of an external PROFIsafe technology box.

Installation steps for installation of the M12 Receptable connector


1. Remove M16 blind plug from the provided option location hole
(bottom) of the BUS connection unit.

2. Screw the middle hexagonal nut towards the front using a size 17
open-ended spanner.

2/4 TI 275274531 - 1318


Connection extension – SK TIE4-M12-INS

3. EMC
Twist associated wire pairs together (e. g. bus system, power
supply, etc.).

4. Pull insulating hose over connecting cables.

5. Screw M12 flanges component directly into the affected M12


threaded opening of the housing or connecting unit of the frequency
inverter. Screw M12 Receptable connector into the relevant M16
threaded opening of the BUS connecting unit.

Alternative option locations


Connection reduction SK TIE4-M20-M16
The M12 Receptable connector can alternatively be installed with an
optional M20-M16 connection reduction.
First screw the M12 Receptable connector directly into the
connection reduction and then fit into one of the side M12 threaded
openings in the connection unit.

6. Align coding pin / coding groove vertically to 12 o'clock by rotating Socket connector Plug connector
the front hexagonal nut.

7. Secure the front hexagonal nut with a 17 mm open-ended spanner.


Screw the rear hexagonal nut to the connection unit or the starter or
frequency inverter housing using a size 17 open-ended spanner or a
special torque / installation wrench.
Take the specified tightening torques into consideration, see
technical data.

8. Ensure that the M12 round plug connector or the cover cap is
properly screwed onto the M12 Receptable connector and
tightened.

NOTICE Corrosion
Pay attention to leaktightness during the installation of all components (assembly, connection extension etc.). It
must be ensured that all components are correctly seated and the tightening torques are adhered to when doing
this.
In order to ensure that protection class IP66 is complied with (concerns all devices with type key SK …-C),
another pressure - leaktightness test must be performed when the assembly work has been completed.
Failure to do this will allow moisture to penetrate the device, which will result in the risk of corrosion and short
circuiting.

TI 275274531 - 1318 3/4


Connection extension – SK TIE4-M12-INS

Information Torque / assembly wrench


In order to provide a secure, sealed and vibration-proof connection, the
M12 connection extensions, which are equipped with a hexagonal
threaded ring (size 17), should be tightened with special torque / assembly
wrenches. For professional installation NORD recommends the use of
commercially available assembly tools (M12, size 17) with an adjustable,
defined tightening torque (e.g. from Murrelektronik).

Electrical connections

Connection extension
Connection terminals
M12 Female connector
SK TI4-TU-SAFE
SK TIE4-M12-INS

Contact Pin Colour Signal Contact Designation


assignments 1 brown T1 25 Clock1
2 white S2 20 SI2
3 n.c.
Female
4 black S1 19 SI1
connector
5 grey T2 26 Clock2
A - coded

Further documentation (www.nord.com)

Document Designation Document Designation

TI 275280300 Bus connection unit SK TI4-TU-SAFE TI 275274511 Connection reduction SK TIE4-M20-M16


TI 275280800 Bus connection unit SK TI4-TU-SAFE-C

4/4 TI 275274531 - 1318

You might also like