Direct Mount 5 Valve Manifolds

Direct Mount 5 Valve Manifolds for


DPharp Differential Pressure Transmitters

5 Valve Manifolds applicable for


Direct Mount DPharp Differential Pressure Transmitters

DPharp Pressure Max. allowable (Working) Pressure (PS)


Application
Transmitter Model MPa bar psi

EJX Series EJX110A 25 250 3,600


Differential Pressure
EJA Series EJA110E 16 160 2,300
EJX Series EJX120A
Draft Range 0.05 0.5 7.25
EJA Series EJA120E
EJX Series EJX130A
Differential Pressure (High Static) 32 320 4,500
EJA Series EJA130E
EJX910A 25 250 3,600
EJX Series Multivariable Transmitter
EJX930A 32 320 4,500

Wafer Style 5 Valve Manifolds - Vent Ports on Bottom Face


1/2 NPT Female x Flanged
This type is basically used for Horizontal Impulse Piping Installations
*
115 (4.53") open

M10
38 (1.50")

105 (4.13") 31.2 (1.23")

246 (9.69") open **

* For High Pressure Type C13ST-5WSY please add 5 mm (0.20'')


** For High Pressure Type C13ST-5WSY please add 10 mm (0.40'')

Direct Mount 5 Valve Manifolds 15


Datasheet for Manifold
Item Description QTY

(Group No. TM‐PDT‐0030) DIFFERENTIAL PRESSURE TRANSMITTER + 5 VALVE MANIFOLD 11

EJX110A‐JHS5G‐91DNN/M01/T13/VR/GF12/DG6/C1/JH01/SLT/Z + MANIFOLD

SUFFIX SPECIFICATION

EJX110A : Differential Pressure Transmitter


J Output signal : 4 to 20 mA DC with digital communication (HART 7 protocol)
H Measurement : 2.5 to 500 kPa, 10 to 2000 in H2O,
span (capsule) 25 to 5000 mbar, 0.025 to 5 kgf/cm2
S Wetted parts material : Capsule : Hastelloy C‐276
Others : 316L SST
5 Process connections : without process connector (1/4 NPT female on the coverflanges)
G Bolts and nuts material : 316L SST
‐9 Installation : Horizontal piping and left side high pressure
1 Amplifier housing : Cast Aluminium Alloy
D Electrical connection : M20 female, two electrical connections and a SUS316 blind plug
N Integral indicator : None
N Mounting bracket : None(it’s a part of enclosure)

/M01 Material certificate : Cover flange


/T13 Pressure test/

Leak test certificate : Test Pressure: 25 MPa(3600 psi)


Nitrogen Gas, Retention time: one minute
/VR : Pattern Approvalmark
/GF12 : Explosion proof approval
/DG6 Advanced diagnostics : Multi‐sensing process monitoring
• Impulse line blockage detection
• Heat trace monitoring
/C1 Output limits and failure
operation : Failure alarm down‐scale: Output status at CPU failure and hardware error
is −5%, 3.2mA DC or less
/JH01 5 points calibration

/SLT : Low temperature expansion of functional safety amb. T° ‐55 to 85°C(SIL 2)


/Z : Calibration and test certificate

MANIFOLD MODEL NO: 5050CDAHHBBA+ST.ST.BOLTS

5050 : Five valve maniofolds


C Rating : 6000 PSI
DA Inlet : 1/2" NPT
HH Outlet : Std. SAMI
B Materials : Aisi 316 L
B Packing : Graphoil
A Bonnet : Std. Bonnet

Note:

1 All unused cable entries are TRCU Exd certified SUS316 plug