○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ VESDA System Management 3™

○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

FM: 3002483,
○ ○ ○ ○ ○ ○ ○ ○

UL Pending

VSM3 is the definitive intelligent system Remote Interrogation


monitoring software package which en- A remote VESDA installation may be accessed
ables you to centrally monitor the status of via modem for interrogation and review. Once
your entire VESDA smoke detection system. connected, all VSM3 functions are available
It allows single point analysis and configu- to the operator including smoke trending,
ration for large or small VESDA installations. reset and isolate. This provides great flexibility
FEATURES in how VESDA systems are deployed and
monitored.
Description

Monitoring of an Entire
VESDA system VSM3 provides a real-time graphical
Intelligent Real-Time Smoke Trending

Remote Notification interface into VESDAnet for PC monitoring
System wide activity on VESDAnet is processed
◗ of an entire VESDA detection system. It also
Remote Interrogation by VSM3 and permanently stored for later
incorporates software features to simplify

Intelligent Real-Time analysis. VSM3 contains a sophisticated
system commissioning and trouble-
Smoke Trending graphing utility designed to pinpoint events
shooting.
◗ allowing site history to be broken down and
Foreign Language evaluated.
Support Monitoring of an Entire System
◗ On-site monitoring of VESDA systems at a Unique Floor Plan Representation
Real-time Status
Reporting
central location is made easy with VSM3 VSM3 allows a site to be graphically
◗ which allows the user multiple views of the monitored with its unique Floor Plan function
Quick Acknowledge- information being processed through the to simplify the acknowledgement of events.
ment of all Events VESDAnet loop. It is possible to view virtual
◗ Floor plans can be integrated into VSM3,
Comprehensive Event detector displays; control specific VESDA with the VESDA devices overlaid. This
Logging zones; conduct smoke trending analysis; graphical presentation provides the user with
◗ identify ground faults through wiring immediate comprehension of a site’s status.
Centralised System
Configuration
overviews or review site plans to
graphically identify incidents.

Comprehensive Report Acknowledgement of Events
Generation Remote Notification To aid the rapid acknowledgement of alarm

VESDA installations can contact a remote and fault conditions, all events appear in a
Floor Plan and System
VSM3 system on the occurence of a speci- live Acknowlegements Window for
Overview
◗ fied event via the latest PC Link HLI and a acceptance and clearing. With each event
Intuitive Online help receiving a date and time stamp, operators
modem. This now makes it possible to
monitor multiple VESDA sites remotely from can immediately access and prioritise response
a centralised location. actions.

Intuitive Online Help


VSM3 contains comprehensive Online help
designed to maximise workflow and assist
understanding of this powerful program.
Included are explanations of all concepts
involved in a VESDA system as well as detailed
How-to procedures for common tasks.

Password Protection
Each operator can be provided with a unique
log-in password (ID). Operator actions are
date and time stamped and are restricted by
up to 3 access levels.
VESDA VSM3 Specifications
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

PC Requirements (minimum):
◗Intel Pentium 120 Processor
◗64mb RAM
◗1.2gb Hard Disk Drive
◗800x600 SVGA display Modem
◗Microsoft Windows 95, 98 or
Windows NT operating system
◗High speed FIFO serial port Remote Connection
(16550 serial chip or compatible)
◗ LEGEND
CD ROM
Remote
Ordering Information: Interrogation
VSM3 VSW-007
Remote
Notification PSTN

Permanent 10
9
8
7
6
1.0
2

1
FIRE

Connection
5
4
Sensitivity ACTION
Smoke Level
3
Zone Number
2
1 First Alarm ALERT
Sector
OK
Isolated
FAULTS Urgent
System Power Airflow
Zone Network Filter

Mode Silence
Test Scan Reset Isolate

10
9 2
8 FIRE
7
1
6
5
4
Sensitivity ACTION
Smoke Level
3
Zone Number
2
1 First Alarm ALERT
Sector
OK
Isolated
FAULTS Urgent
System Power Airflow
Zone Network Filter


Mode Silence
Test Scan Reset Isolate


HLI
VESDA
Installation
HLI Modem
10
9 2
8 FIRE
7
1
6
5
ACTION

VSM3 On-site
Sensitivity
4
Smoke Level
3
Zone Number
2
1 First Alarm ALERT
Sector
OK
Isolated
FAULTS Urgent
System Power Airflow
Zone Network Filter

Mode Silence
Test Scan Reset Isolate


Total System Monitoring 10

1
OK
9
8
7
6
5
4
3
2
1.0
Sensitivity
Smoke Level
Zone Number
First Alarm
Sector
Isolated
2

1
FIRE

ACTION

ALERT

FAULTS Urgent
System Power Airflow
Zone Network Filter

Mode Silence
Test Scan Reset Isolate

VSM3 can remotely communicate with a PC running VSM3 The remote VESDA site also has the ability to initiate a
Software or directly to a VESDA installation with the use of a PC connection with VSM3 when a specific (configurable)
Link HLI. condition occurs with the PC Link HLI.

VSM3 Zone Mimic Display VSM3 Smoke Trend Window

Australia and Asia The Americas Europe and the Middle East www.vesda.com
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○

Vision Fire and Security Vision Fire and Security Vision Fire and Security
495 Blackburn Road 35 Pond Park Road Vision House, Focus 31, Mark Road
Mount Waverley VIC 3149 Australia Hingham, Massachusetts, USA 02043 Hemel Hempstead, Herts. HP2 7BW
Ph: 61 3 9211 7200 Ph: (781) 740-2223 or United Kingdom
Fax: 61 3 9211 7201 (800) 229-4434 Ph: +44 1442 242 330
Vision Systems Freecall: 1 800 700 203 Fax: (781) 740-4433 Fax: +44 1442 249 327
©2001 Vision Fire and Security All rights reserved. In accordance with its policy of continuing product and system improvement, Vision Products reserves the right to change design or specifications without obligation and without further
notice. VESDA® is a registered trademark of Vision Products Pty. Ltd. VESDA LaserPLUS, LaserSCANNER, LaserCOMPACT, VESDAnet, VESDAlink, ASPIRE, AutoLearn, VSM, VConfig and InfoWORKS are trademarks of Vision Products Pty. Ltd.

No: 19276 Revision: 0 Printed: February 2001

You might also like