EP-3169 Upgrade Firmware (WEB) - 1 - Service Manual
EP-3169 Upgrade Firmware (WEB) - 1 - Service Manual
EP-3169 Upgrade Firmware (WEB) - 1 - Service Manual
EP-3169 Series
2009/6/6
1
Chapter 1
Hardware Connection
2
1.1 External RS232 Cable
3
1.2 RS232 Cable Install to RS232 Port of Controller 1
4
1.3 RS232 Cable Install to RS2323 port of SES Board
5
Chapter 2
6
2. Firmware Version List
Controller Firmware / Expander Firmware / proSES Firmware/ proRAID Manager / Web GUI
1.10 / v379 / 1.13 / 1.5.25 / Not Support
1.11 / v379 / 1.13 / 1.5.25 / Not Support
1.20 / v388 / 1.16 / 1.5.34 / Not Support
1.30 / v389 / 1.18 / 1.5.35 / Yes
1.31 / v407 / 1.19 / 1.5.37 / Yes
Please install the correct proRAID Manager version for each firmware.
7
2.1 Firmware Upgrade From 1.1x or 1.20 to 1.3x
8
2.2 Firmware Upgrade From 1.30 to 1.31
9
2.1 Firmware Upgrade Approved List
SATA Disks
New 1.11 1.2 1.21 --> 1.30 1.21 --> 1.31 Remark
Original
From 1.01 to 1.20
1.01 OK OK OK OK or 1.21 IP need to
reassign
1.07 OK OK OK OK V3 Controller
1.09 OK OK OK OK V3 Controller
1.10 OK OK OK OK V3 Controller
V3 Controller
1.20 Not Approve No Need OK OK
V4 Controller
V3 Controller
1.30 Not Approve Not Approve No Need OK
V4 Controller
V3 Controller
1.31 Not Approve Not Approve Not Approve OK
V4 Controller
10
2.1 Firmware Upgrade Approved List
SAS Disks
New 1.11 1.2 1.21 --> 1.30 1.21 --> 1.31 Remark
Original
1.09 OK OK OK OK V3 Controller
1.10 OK OK OK OK V3 Controller
V3 Controller
1.20 Not Approve No Need OK OK
V4 Controller
V3 Controller
1.30 Not Approve Not Approve No Need OK
V4 Controller
V3 Controller
1.31 Not Approve Not Approve Not Approve OK
V4 Controller
FAIL : RAID become to inaccessible.
How to Upgrade
Backup of all SAS Raid volume data at Firmware 1.01 or 1.07.
Subsequent upgrade new firmware as you need, SAS Raid and volume(s) re-creation, and Restore of all data, would provided for
repeat availability of data.
11
Chapter 3
Java-Based
proRAID Manager
Uninstall / Install
12
3.1 Uninstall proRAID Manager
13
3.2 Install proRAID Manager
Insert CD
proRAIDManager
14
3.2 Support OS
Instruction
includes without
Platform s
Java VM Java VM
Download
MacOSX (12.6M) View
Download
Windows (39.6M) View
Download
AIX (72.1M) View
Download
HPUX (76.1M) View
Download
Linux (45.9M) View
Download
Solaris (65.8M) View
Any Unix Download
Platform (13.4M) View
Download
Solaris Intel (60.9M) View
Other Java-
enabled Download
Platforms (13.2M) View
15
3.3 Install proRAID Manager on Windows
Windows Instructions:
Instructions
•After downloading, double-click install.exe
Notes
•You do not need to install any other software. A Java virtual machine is
included with this download.
(Go To Top)
16
3.4 Install proRAID Manager on MAC
Mac OS X Instructions:
Instructions
•After downloading, double-click install
Notes
•Be sure you have Java installed. You can download Java from
Apple's site
•The compressed installer should be recognized by Stuffit
Expander and should automatically be expanded after
downloading. If it is not expanded, you can expand it manually
using StuffIt Expander 6.0 or later.
•If you have any problems launching the installer once it has
been expanded, make sure that the compressed installer was
expanded using Stuffit Expander. If you continue to have
problems, please contact technical support.
(Go To Top)
17
3.5 Install proRAID Manager on Aix
AIX Instructions:
Instructions
•After downloading open a shell and, cd to the directory where you
downloaded the installer.
•At the prompt type: sh ./install.bin
Notes
•A Java virtual machine is included with this download. It will run
automatically when you run the shell script.
(Go To Top)
18
3.6 Install proRAID Manager on Solaris
Solaris Instructions:
Instructions
•After downloading open a shell and, cd to the
directory where you downloaded the installer.
•At the prompt type: sh ./install.bin
Notes
•A Java virtual machine is included with this
download. It will run automatically when you run the
shell script.
(Go To Top)
19
3.7 Install proRAID Manager on Linux
Linux Instructions:
Instructions
•After downloading open a shell and, cd to the directory where you
downloaded the installer.
•At the prompt type: sh ./install.bin
Notes
•A Java virtual machine is included with this download. It will be run
automatically when you run the shell script.
(Go To Top)
20
3.8 Install proRAID Manager on HP-UX
HP-UX Instructions:
Instructions
•After downloading open a shell and, cd to the directory where you
downloaded the installer.
•At the prompt type: sh ./install.bin
Notes
•A Java virtual machine is included with this download. It will be run
automatically when you run the shell script.
(Go To Top)
21
3.9 Install proRAID Manager on Solaris_Intel
Solaris_Intel Instructions:
Instructions
•After downloading open a shell and, cd to the directory where you
downloaded the installer.
•At the prompt type: sh ./install.bin
Notes
•A Java virtual machine is included with this download. It will be run
automatically when you run the shell script.
(Go To Top)
22
3.10 Install proRAID Manager on General_Unix
Notes
•You need to install a Java virtual machine. You can download one
from Sun's Java web site or contact your OS manufacturer.
(Go To Top)
23
3.11 Install proRAID Manager on Other Platform
24
3.12 Install proRAID Manager on Other Platform
25
Chapter 4
SES
Firmware Upgrade
26
4.1 SES Boards Version
To upgrade the SES firmware, first you need to check SES board
version number. Check in the LCD display the SES version (use
arrow down key).
27
4.2 SES2 (5601) Board
Another option is to check the SES board version. Power off the
RAID subsystem and remove the SES module. Check the board
version from the label marked on the SES board.
28
4.3 SES2 (5601) Upgrade Procedure – Setup
29
4.4 SES2 (5601) Upgrade Procedure - Upgrading
30
4.5 SES2 (5601) Upgrade Procedure - Upgrading
31
4.6 SES2 (5601) Upgrade Procedure - Upgrading
1.Select Ymodem
Ymodem
EP95601_118.bin
EP95601_118.bin
32
4.7 SES (6601) Board
PRO-90-6601 Ver: 1.x
6601 SES Board can’t show IP address in LCD Panel after
upgrade firmware finished
Page 53 provide another way to get IP address
33
4.8 SES (6601) Upgrade Procedure – Setup
NOTE: The upgrade process is done twice. The first time needs a
jumper in JP8. The second time does not need a jumper.
•Power off the RAID system. Remove the SES Module. Insert a jumper in JP8 of
SES board PRO-90-6601.
JP8
34
4.9 SES (6601) Upgrade Procedure - Setup
35
4.10 SES (6601) Upgrade Procedure - Upgrading
36
4.11 SES (6601) Upgrade Procedure - Upgrading
Select Xmodem
37
4.12 SES (6601) Upgrade Procedure - Upgrading
EP96601_119.bin
EP96601_119.bin
38
4.12 SES (6601) Upgrade Procedure – Upgrade 2 times
39
4.13 SES Firmware version confirm
1. LCD Panel
You can refer chapter 4.1
You can refer the below chart of 6.2 and 6.3 for command mode using.
40
4.13 SES Firmware version confirm
login: root
Password:00000000
# qm
please put a command
show enclosures
thanks
processing command line: show enclosures
41
Chapter 5
Controller
42
5.1 Java-Based proRAID Manager – Start Up
43
5.2 Java-Based proRAID Manager – User name & Password
Enter the
User Name : admin
Password : admin
44
5.3 Java-Based proRAID Manager – LAN Connection
On Line : You can upgrade firmware from your PC to Controller
EP-3169D-F4S3
Version1.20
45
5.3 Java-Based proRAID Manager – LAN Connection
Off Line : You can not upgrade firmware from your PC to Controller
EP-3169D-F4S3
Version1.20
46
5.4 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
Version1.20
47
5.4 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
48
5.4 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
2 Controller Bridge Firmware upgrade
EP-901045-1.21.bin
EP-901045-1.21.bin
49
5.4 Java-Based proRAID Manager – Controller Bridge Firmware Upgrade
Notice :
Firmware will auto upgrade to controller 2 if you have
redundant controllers model.
50
5.5 Controller Bridge Firmware Version Confirm
Version 1.21
51
5.6 Power off / power on
Notice!
52
Chapter 6
Controller Expander
Firmware Upgrade
53
6.1 Java-Based proRAID Manager – Start Up
54
6.2 Java-Based proRAID Manager – User name & Password
Enter the
User Name : admin
Password : admin
55
6.3 Java-Based proRAID Manager – Controller Expander Upgrade
Version1.21
56
6.3 Java-Based proRAID Manager – Controller Expander Upgrade
57
6.3 Java-Based proRAID Manager – Controller Expander Upgrade
Select All Files on File Type item and choose you want
upgrade expander firmware version.
V 407.s3r
58
6.3 Java-Based proRAID Manager – Controller Expander Upgrade
Click OK
EP-3169D-F4S3
OK
59
6.3 Java-Based proRAID Manager – Controller Expander Upgrade
Click OK
EP-3169D-F4S3
OK
60
6.4 Upgrading could take several minutes to complete
Notice!
61
6.5 Controller Expander Firmware Version Confirm
0407
0407
62
6.6 Power off / power on
Notice!
63
Chapter 7
Controller
Firmware Upgrade
64
7.1 Java-Based proRAID Manager – Start Up
65
7.2 Java-Based proRAID Manager – User name & Password
Enter the
User Name : admin
Password : admin
66
7.3 Java-Based proRAID Manager – Controller Firmware Upgrade
Version1.21
67
7.3 Java-Based proRAID Manager – Controller Firmware Upgrade
Choose “Upgrade Controller” tab
68
7.3 Java-Based proRAID Manager – Controller Firmware Upgrade
Select you want to upgrade firmware version
EP-901045-1.31.bin
File Type
69
7.3 Java-Based proRAID Manager – Controller Firmware Upgrade
Notice !
Don’t Click “Yes”, please click “No”
70
7.4 Power off / on
Notice!
71
7.5 Controller Firmware Version Confirm
Version 1.31
72
Chapter 8
Web-Based
proRAID Manager
73
8.1 Show IP address - LCD Panel
74
8.2 Show IP address - Console of Controller
You can see the IP address on console for 6601(SES) board
Login to console of controller via RS232 cable.
( Refer Chapter1.2 )
Login : netadmin
************Current ip setting*********
Dynamic Ip address
netmask ::: 255.255.0.0 Å Type command follow left table
inet addr ::: 10.11.1.40
gateway ::: 10.11.1.3
dns1 ::: 10.11.1.2
dns2 ::: 84.203.255.34
domain ::: raidtec.ie
***************** end **************
please enter a command
75
8.2 Web-Based proRAId Manager – User name and Password
76
8.3 Web-Based proRAId Manager - Enable proRAID Manager
How to change to Java-based from Web-based proRAID manager on firmware 1.30?
(1.31 firmware no this item.)
Notice !
Web GUI is the
default Management
tool when you power
on with 1.30 firmware.
77
8.4 Web-Based proRAId Manager - Enable Web GUI
You can return to Web GUI Management with 1.30 firmware. (1.31 firmware no this item)
78
8.5 Controller Firmware Version Confirm
79
8.6 Expander Firmware Version Confirmation From Web
80
8.7 Upgrade from 1.30 to higher
81
8.7.1 Upgrade from 1.30 to higher
Click on “Administration>Upgrade Firmware” menu
82
8.7.2 Locate the FW File
Click on “Browse” to locate the firmware
83
8.7.3 Upgrade process
Click on “Upgrade” button to start the firmware upgrade process
NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host
access before proceeding to upgrade
84
8.7.4 Upgrade in progress
Upgrade in progress
NOTE: For dual controller, the firmware will auto upgrade the other boards.
85
8.7.5 Upgrade Complete
Upgrade Complete.
86
8.7.6 Upgrade Complete
System Online after reset, the EP-3169 is now ready to use.
87
8.7.7 Verify New Version
Click “System Information “menu to verify new version.
EP-3169D-F4S3
88
8.8. Upgrading the Expanders
Click on “Administration>Upgrade Firmware” menu to upgrade the expander firmware
89
8.8.1 Locate the Expander FW File
Click on “Browse” to locate the expander firmware ,the firmware should in
.s3r extension
90
8.8.2 Expander Upgrade Start
Click on “Upgrade” button to start the expander firmware upgrade process
NOTE: Stop all RAID operation e.g. “Rebuild, Initialization, verify” and host
access before proceeding to upgrade the expander.
91
8.8.3 Upgrade in progress
Firmware uploading in progress
NOTE: For EP-3169D dual controller and EP-3169JD , the firmware will auto
upgrade the expanders firmware on the other boards and on the jbod. Each
expanders upgrade process will take around 3~5 minutes.
92
8.8.4 Background Install
Background installation is progress.
NOTE: For EP-3169D dual controller and EP-3169JD , the firmware will auto
upgrade the expanders firmware on the other boards and on the jbod. Each
expanders upgrade process will take around 3~5 minutes.
93
8.8.5 Verify new Firmware version
Click “System Information” menu
NOTE: For dual controller, the firmware will auto upgrade the expanders
firmware on the other boards.
94