Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

Navigating the intricate landscape of academic literature can be a daunting task, especially when it

comes to crafting a comprehensive literature review. This critical component of scholarly research
requires meticulous attention to detail, extensive research, and adept synthesis of existing literature.
For those delving into topics like flat slab construction, the challenge is even greater, given the depth
and breadth of available literature.

Writing a literature review on flat slab construction involves sifting through numerous scholarly
articles, books, conference papers, and other relevant sources to gather pertinent information. It
requires not only identifying key studies but also critically evaluating their methodologies, findings,
and contributions to the field. Moreover, synthesizing disparate sources into a coherent narrative that
highlights gaps, trends, and debates requires a high level of analytical skill and finesse.

Given the complexities involved, many researchers find themselves overwhelmed by the task of
crafting a literature review that meets the rigorous standards of academic scholarship. That's where
⇒ StudyHub.vip ⇔ comes in. Our team of experienced writers specializes in assisting scholars with
literature reviews on a wide range of topics, including flat slab construction.

By entrusting your literature review to ⇒ StudyHub.vip ⇔, you can rest assured that you'll receive a
meticulously researched, expertly written document that adheres to the highest academic standards.
Our writers possess the expertise and resources necessary to tackle even the most challenging topics,
delivering comprehensive literature reviews that demonstrate a deep understanding of the subject
matter.

Don't let the daunting task of writing a literature review hold you back in your academic pursuits.
Trust ⇒ StudyHub.vip ⇔ to provide you with the assistance you need to succeed. Contact us today
to learn more about our services and how we can help you achieve your scholarly goals.
IRJET Journal A REVIEW ON THE PERFORMANCE OF COCONUT FIBRE REINFORCED
CONCRETE. Fig. 1.4 Slab with drop and column with column head. Shear wall are specially
designed structure walls include in the building to resist horizontal forces that are includes in the
plane of the wall due to wind, EQ and other forces. The non-linear dynamic analysis i.e. Time
History approach used of Seismic response of the building. The peak value of the moment
determined at the column axis is. Effect of Camber and Angles of Attack on Airfoil Characteristics
Effect of Camber and Angles of Attack on Airfoil Characteristics A Review on the Progress and
Challenges of Aluminum-Based Metal Matrix Compos. International Research Journal of
Engineering and Technology (IRJET) e-ISSN: 2395-0056. From this analysis shear wall at core
having square shape is most suitable case for construction of shear wall. The article showcases the
parametric study in terms of storey drift, displacement and base shear comparison for different
location of shear wall in the building. Along with this, how its behavior varies and improves with the
introduction of shear wall is studied using static nonlinear analysis, i.e., pushover analysis, and the
results are presented. Using flat slab buildings has numerous benefits over standard RC frame
buildings in terms of simpler formwork, space use, architectural flexibility as well as quicker
construction times. IRJET Journal Dynamic Urban Transit Optimization: A Graph Neural Network
Approach for Real-. IRJET- Performance of Flat Slabs and Flat Plates in High Seismic Zone with Va.
In modern-day construction, RC systems are generally used for construction. As a result of that the
buildings which consist of flat slab must to be devoted to requirements of connecting to public
utilities such as deflation pipes or gas pipes or others. IRJET Journal COMPARATIVE STUDY ON
SEISMIC ANALYSIS OF CONVENTIONAL SLAB AND FLAT SLAB STRU. Fig. 1.2 Slab
without drop and column with column head. Among many type of loads due to point loads the slabs
may subjected to flexure and shear. Main object or aim of this comparison is to use this result in
future to get more economical and more strengthen slab for long span or long panel. In this method
tendon ducts are left without grouting and grouting process is only used at anchorage portion.
Reinforced flat slabs may need to be sensibly pre-cambered (not overdone) to control deflection.
Frame consists of vertical and horizontal elements. As per local conditions and availability of
materials different countries have adopted different methods for design of flat slabs and given their
guidelines in their respective codes. Flat slab structures result in financial savings, aesthetic views,
and greater artistic flexibility for the architect in contrast to typical slab structures. The buildings
with soft storey are very susceptible under earthquake load which create disasters. Keywords:
R.C.C, Flat slab with or without drop, strengthening and Concrete, Rate analysis per sq m, Etabs
software. Considering zone 2 and zone 3 of seismicity according to Indian codes. All slab
reinforcement should be anchored property at discontinuous edges. From results, it can be concluded
that bubble deck slab has vast amount of concrete saving as it reduces the dead weight of the
structure and hence the quantity of concrete is reduced considerably. Flat slabs are more vulnerable
to punching shear because of absence of beam.
IRJET- Study of Literature on Seismic Response of RC Irregular Structure IRJET- Study of
Literature on Seismic Response of RC Irregular Structure More from IRJET Journal TUNNELING
IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO SUNGAL TUNNE.
IRJET- Performance of Flat Slabs and Flat Plates in High Seismic Zone with Va. After studying all
the model post-analysis result, they. To determine extreme values of positive and negative moments
and. These slabs have been proved to be the most economical when compared to the RCC slabs. The
report includes detailed analysis of a multi storey Commercial building using software ETABs. Flat
slab structures provide more advantages such as large spans, plain ceiling, and low shuttering cost
and less construction time, increases building height etc. However, there remains the most critical
forces moments and punching shear. For columns sections with re-entrant angles, the critical section
shall be taken as indicated in Fig. 1.7. Comparative study on the maximum displacement of storey
and centre of mass of different shaped buildings due to static loading has been explored. To browse
Academia.edu and the wider internet faster and more securely, please take a few seconds to upgrade
your browser. To support heavy loads the thickness of slab near the support with the column is
increased and these are called drops, or columns are generally provided with enlarged heads called
column heads or capitals. Any structure is made up of structural elements (load carrying, such as
slabs, beams and columns) and non-structural elements (such as partitions, false ceilings, doors).
Wind and Seismic Analysis of Building with Bracing System Resting on Sloping. This paper
presents the review of various techniques and methods used to investigate uses of belt truss and
outrigger system in a tall building. Considering zone 2 and zone 3 of seismicity according to Indian
codes. The shear walls are the reinforced walls which when combined with structure, increases the
lateral resisting capacity of structure. Also an attempt has been made to design the structural
elements manually. IRJET- Seismic Performance of Geometric Vertical Irregular Flat Slab Multisto.
Adobe Express Go from Adobe Express creation to Issuu publication. Each and every structure will
be subjected to either one or the groups of loads, the various kinds of loads normally considered are
dead load, live load, earth quake load and wind load. In this study, the seismic behavior of different
sizes of conventional slab, flat slab and bubble deck slab is evaluated under different loadings with
the help of SAP 2000 software, along with this quantities of steel and concrete are estimated for
comparison. These effects combine with lateral loading causing critical issue in design of slab. As
this structure means flat slab and having there types) are compared more flexible than conventional
concrete frame structure, therefore becoming more vulnerable to earthquake loading. Whereas the
conventional beam slab buildings perform better in seismic regions. It is concluded that there is
increase in bases shear, story displacement and story drift in irregular building than in regular
building due to earthquake forces in the seismic zone ii using ETABS Software 2016. IRJET- Seismic
Analysis of Buildings with Shear Wall having Horizontal Ir. The response spectrum analysis was
carried out by using software of ETAB's version 9.7.4.considering bracing and shear wall at a
different location in the building. The non-linear dynamic analysis i.e. Time History approach used
of Seismic response of the building. Digital Sales Sell your publications commission-free as single
issues or ongoing subscriptions.
IRJET- An Innovative Method of Electricity Generation from Speed-Breakers of. The minimum
percentage of the reinforcement is same as that in solid slab i.e., 0.12 percent if. The method used for
analysing the model is Linear Time history analysis considering Locc-North seismic condition using
software namely ETABS 2015. Seismic load is a major component in the collapse of many high-rise
buildings. The response spectrum analysis was carried out by using software of ETAB's version
9.7.4.considering bracing and shear wall at a different location in the building. A Review on
Investigation of Effect of Floating Column and Infill Wall on the. The slab rests on the column
directly and load from the slab is directly transferred to the columns and then to the foundation. The
consequences of shear pressure, Bending Moment, story shear, story displacement, story drift and
amount of concrete and steel indicates that the general end result values makes flat slab an
appropriate in comparison to different slab arrangement. IRJET Journal Seismic Performance and
Shear Wall Location Assessment of a RC Building- Eva. The report includes detailed analysis of a
multi storey Commercial building using software ETABs. A Review on Investigation of Effect of
Floating Column and Infill Wall on the. Long Term Trend Analysis of Precipitation and Temperature
for Asosa district. The following seismic parameters were analyzed and the behavior of the structure
was studied in detail. The objective of this paper is to present analysis and design of RC flat slab
using two different methods and compare the superiority of the two methods over one another by
various aspects. Statistics Make data-driven decisions to drive reader engagement, subscriptions, and
campaigns. Example 1.4: A flat slab system consists of 5 m ? 6 m panels and is without drop and
column head. Analysis were done by dynamic method as per IS: 1893-2016, and all the RCC
members were designed as per IS: 456-2000. Fig. 1.3 Slab with drop and column without column
head. You can download the paper by clicking the button above. Teams Enable groups of users to
work together to streamline your digital publishing. It is widely used in heavy structures like bridges,
mat foundation etc. It uses simple formwork arrangement and reinforcing arrangement, and requires
the least story height. A Comprehensive Review of Integrating IoT and Blockchain Technologies in
the. To avoid this, collapse two methods are used, first method is increasing the column dimensions
and, the other is to use drop panel if the first method leads to uneconomical, design. Help Center
Here you'll find an answer to your question. They are mainly a flexural member and usually provided
in the high rise building to avoid the total collapse of the high rise building under seismic forces. QR
Codes Generate QR Codes for your digital content. Microstrip Bandpass Filter Design using EDA
Tolol such as keysight ADS and An. A building is analyzed having regular and irregular shape under
the effect of earthquake loading by using latest software Aid. After studying all the literature review,
they conclude that.
The present paper work was made in the interest of studying various research works involved in
enhancement of flat slab, shear wall and flat slab with shear wall and their behavior towards lateral
loads. Help Center Here you'll find an answer to your question. Different design methodologies have
been adopted and critically reviewed and inferences are made for the selection of the particular
method of designing the flat slab. The present work also provides comparative results between RC
slab and PT slab at the same loading conditions. Present work provides a good source of information
on storey drift, storey displacement, base shear, storey shear, column forces and time period. As IS
code is silent about flat slab structure design provisions in higher seismic zones, while analyzing
these structures in such zones, we must have certain provisions to get rid of its poor performance.
Structural Analysis and Design of Multi-Storey Symmetric and Asymmetric Shape. Download Free
PDF View PDF Comparative Study of Reinforced Concrete Flat Slabs with and without Openings
using Finite Element Analysis IJIRST - International Journal for Innovative Research in Science and
Technology A reinforced concrete flat-plate floor system is widely used in various types of building
structures including condominiums, parking garages, and office buildings. It uses simple formwork
arrangement and reinforcing arrangement, and requires the least story height. Download Free PDF
View PDF IRJET-Seismic study and performance of 30 storey high rise building with beam slab, flat
slab and alternate flat-beam slab systems in Zone-V IRJET Journal The use of flat slab building
provides many advantages over conventional RC Frame building in Terms of architectural flexibility,
use of space, easier formwork and shorter construction time. Video Say more by seamlessly including
video within your publication. See Full PDF Download PDF See Full PDF Download PDF Related
Papers ISSN: 2277-3754 ISO 9001:2008 Certified JOJO JOHN Download Free PDF View PDF A
Review on Seismic Assessment of Post- Tensioned Flat Slab IJSTE - International Journal of Science
Technology and Engineering The use of post-tensioned flat slab is increasing widely, due to its
advantages over traditional concrete. The behavior of Conventional slab and Flat slab structure with
and without shear wall in seismic zone II, III, IV and V with type II (medium) soil are taken for all
instances. Issuu turns PDFs and other files into interactive flipbooks and engaging content for every
channel. The consequences of shear pressure, Bending Moment, story shear, story displacement, story
drift and amount of concrete and steel indicates that the general end result values makes flat slab an
appropriate in comparison to different slab arrangement. From the above studies carried out by
researcher, following. This abstract deal with work carried out to compare the bubble deck voided
slab system and conventional flat slab system by finite element analysis using SAP 2000 as well as
manual calculation by Direct design method using IS456:2000 to study the behavior of bending
moments, shear force, deflections and reactions due to change in span for various load conditions.
Issuu turns PDFs and other files into interactive flipbooks and engaging content for every channel.
It's like a masterclass to be explored at your own pace. Majorly because of the relatively thin slab
depths, lighter in weight and smaller floor to floor heights, Post-tensioned slabs have been used for
such construction. Absence of beam gives a plain ceiling, thus giving better architectural appearance
and also less vulnerability in case of fire than in usual cases where beams are used. RELATED
PAPERS Velocita critiche di galloping e risposta post-critica di cavi laschi soggetti all’azione del
vento Walter Lacarbonara Download Free PDF View PDF Validation of a Chemiluminescence
Immunoassay for Measuring Amyloid-. The design of structures is the subject of research not only in
India but also in other developed nations. Using flat slab buildings has numerous benefits over
standard RC frame buildings in terms of simpler formwork, space use, architectural flexibility as
well as quicker construction times. Absence of beam gives a plain ceiling, thus giving better
architectural appearance and also less vulnerability in case of fire than in usual cases where beams are
used. For columns sections with re-entrant angles, the critical section shall be taken as indicated in
Fig. 1.7. Post tensioning method is very popular now days, because difficult method of construction.
IRJET Journal IRJET- Seismic Analysis of Buildings with Shear Wall having Horizontal Ir. The
present work provides reasonable information regarding the suitability of Post-tensioned flat slab
over RC flat slab. QR Codes Generate QR Codes for your digital content.
Storey with a plan area 37.5 m x 37.5 m. is untaken for analysis in CSI-ETABSvr.2016 Software. The
commercial building under taken in the earthquake Zone-IV for the city Rajkot in Gujarat. See Full
PDF Download PDF See Full PDF Download PDF Related Papers PARAMETRIC STUDY OF
FLAT SLAB BUILDING WITH AND WITHOUT SHEAR WALL TO SEISMIC
PERFORMANCE eSAT Journals Recently there has been a considerable increase in the number of
tall buildings, both residential and commercial, and modern trend is towards taller structures.
Microstrip Bandpass Filter Design using EDA Tolol such as keysight ADS and An. The initial cost of
the flat slab is high and also results shows that the ductility of building and stiffness of the building
is within the codal provision. While designing the flat slab structures with slender column, response
under seismic loading for different zones is very important.This paper deals with study on literature
review of different-authors on behavior of flat slab structures under seismic loading for better
understanding of flat slab structures and concept of slender column. The resultant conclusion will be
used in defining the failing mechanism that can be useful in the formulation of an adequate
mathematical model. It's like a masterclass to be explored at your own pace. Analysis of flat and
conventional slab structures has been done using ETABS software. You can download the paper by
clicking the button above. The feeble amount of space is forcing us to lift the high level of structures
as much as possible to give space to greatest point number of people.Flat bit of material buildings are
the ones in which slab is directly supported by columns for the advantage of reducing floor to floor
height to make the structure cost effective and meet structural demands. The reviewed approach for
the design and development of tall building using outrigger and belt truss is useful to provide a
potential solution. Earthquake is causing more damage to different configuration of building and
their main problem is in the slenderness ratio. High density polythene (HDPE) hollow spheres are
placed in the center of slab by replacing the ineffective concrete to decrease its dead weight so
increase the efficiency of floor. Download Free PDF View PDF Seismic Behaviour of R.C Frame
Building with and Without Masonry Infill Walls GRD JOURNALS Reinforced concrete frame
structure is very common in present times due to its ease in construction. Evaluation of Flat Slab by
Varying Percentage of Infill Wall in RC Building U. Due to advancements in civilization emphasis
has been put on the construction of newer and more advanced structures like buildings, shopping
malls, airports, railway stations, etc. Analysis is carried out by static method and design is done as
per IS 456:2000 guidelines. More Features Connections Canva Create professional content with
Canva, including presentations, catalogs, and more. Download Free PDF View PDF A Review of
Comparative Study on R.C.C and Post Tensioned Flat Slab Considering Seismic Effect International
Journal of Scientific Research in Science, Engineering and Technology IJSRSET This review paper
is focused on post tensioned and flat slab. The flat slab has less stiffness and less shear strength with
more flexibility feature than the conventional slab. IRJET- A Review on R.C.C. Structure with Fully,
Partially and without Infille. IOSR Journal of Engineering (IOSRJEN) Vol. 06, Issue 09. Palma,
Arch PhD. Going Staff Going Staff Tobias Pfeiffer Microstrip Bandpass Filter Design using EDA
Tolol such as keysight ADS and An. Articles Get discovered by sharing your best content as bite-
sized articles. Resources Dive into our extensive resources on the topic that interests you. Design of
flat plate slab and its Punching Shear Reinf. IRJET Journal More from IRJET Journal ( 20 )
TUNNELING IN HIMALAYAS WITH NATM METHOD: A SPECIAL REFERENCES TO
SUNGAL TUNNE. The most critical force is the punching shear force becaus e it's sudden failure.
IRJET Journal Dynamic Urban Transit Optimization: A Graph Neural Network Approach for Real-.
Hence singly reinforced section can be designed i.e., thickness provided is satisfactory from the.
This paper reviewed the several study done on voided slab system. These forces' effects increased
when an opening is placed at a location at which cut the path of th e load to column. Fig. 1:
Punching shear failure A. These slabs have been proved to be the most economical when compared
to the RCC slabs. Statistics Make data-driven decisions to drive reader engagement, subscriptions,
and campaigns. These include the design of RCC Flat slab as well as RCC beam-and-slab floor
systems and then comparing the results. Considering zone 2 and zone 3 of seismicity according to
Indian codes. Download Free PDF View PDF A STUDY ON SEISMIC ANALYSIS OF MULTI-
STOREY FLAT SLAB AND CONVENTIONAL STRUCTURES WITH AND WITHOUT SHEAR
WALLS USING ETABS IRJET Journal Download Free PDF View PDF See Full PDF Download
PDF Loading Preview Sorry, preview is currently unavailable. The equivalent static method is used
to design and analyze the structures, as categorized by Indian Standard Code for earthquake resistant
structures. In addition, flat slab constructions do not restrict the positioning of horizontal services
and partitions and help to minimize floor-to-floor heights. The analysis and design is verified all
Indian stranded codal provision in manual calculations as well as a power full computer software
SAP2000. By the study of literature in the research areas of Post-Tensioned Slab technique, some
secondary moment effects are observed in the analysis of this slab. Here evaluation And layout of a
Conventional Slab, Flat Slab, Waffle Slab, Grid Slab, and Load bearing wall is finished the usage of
ETABS. You can download the paper by clicking the button above. To browse Academia.edu and the
wider internet faster and more securely, please take a few seconds to upgrade your browser. Thus, to
resist this lateral loading, this system is provided with lateral load resisting elements such as shear
walls. In this paper analysis of RC flat slab with drop and post-tensioned flat slab with drop is
carried out. Its function is to resist effectively the action of gravitational and environmental loads,
and to transmit the resulting forces to the supporting ground, without significantly disturbing the
geometry, integrity and serviceability of the structure. As IS code is silent about flat slab structure
design provisions in higher seismic zones, while analyzing these structures in such zones, we must
have certain provisions to get rid of its poor performance. In flat slab design, this is major concern
and utmost importance is provided to safe guard the slab against the punching failure. The method
used for analysing the model is Linear Time history analysis considering Locc-North seismic
condition using software namely ETABS 2015. The aim of the present study is to evaluate the
behavior of multi-storeyed building of conventional R.C.C. having flat slab with or without shear
walls and to analyze the. QR Codes Generate QR Codes for your digital content. The thickness of
slab near the support with the column is increased to support with the columns is increased to support
heavy loads, and these are called drops, or columns are generally provided with column heads or
column capitals. Common practice of design and construction is to support the slabs by beams and
support the beams. There are two methods of analysis of RC flat slab viz. Adobe Express Go from
Adobe Express creation to Issuu publication. Download Free PDF View PDF Comparison of
Analysis Methods of Flat Slab IJIRST - International Journal for Innovative Research in Science and
Technology A floor system plays an important role in overall cost and service of the building. Social
Posts Create on-brand social posts and Articles in minutes. It is necessary to analyze seismic behavior
of building to see what parameters are going to changes in conventional RC Frame building, flat slab
building and alternate floor flat-beam slab building with corner shear wall, middle shear wall and
without shear wall. The use of different types of plates is developing as a new trend and is becoming
a major challenge for structural engineers.

You might also like