Ground Floor Plan Second Floor Plan Roof Plan: Service Area Kitchen Dining Area Lanai Bedroom 3 Bedroom 2

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 3 2 3 4

1 2 3 4 1 2 3 4 A-3
3 3
A-3 A-3

W
4
W
4
W
4
W
4
A
A A
D
LANAI 5
SERVICE
DINING KITCHEN AREA BEDROOM 2 BEDROOM 3
D
1 AREA
W ACU ACU
5

D
4 B 2 2
T&B1 D D A-3
B 2 B 3 3 2 A-3
2 W
7 PANTRY LINEN/STO.
A-3 2 W
7
COMMON A-3
A-3 STORAGE T & B COMMON
A-3
A R E A
W
7 MTR. T&B
D
4 C
D
C C 3
D
4 D
3 D
ACU 5
LIVING AREA BEDROOM 1
MASTERS'
BEDROOM FAMILY AREA
ACU
W W BALCONY BALCONY
6 6
D
2
CARPORT D
D PORCH D W W W
6 6 6

W
2
W W
E
3 6
E E 3
A-3
3 3
A-3 A-3

PROJECT EL SUKKAH PROJECT EL SUKKAH PROJECT EL SUKKAH


GROUND FLOOR PLAN SECOND FLOOR PLAN ROOF PLAN

1 2 3 4 A B C D E E D C B A

±6500 T. PPT ±6500 T. PPT ±6500 T. PPT

±5700 T.RB ±5700 T.RB ±5700 T.RB

±3000 SF.FL ±3000 SF.FL ±3000 SF.FL

±300 GF.FL ±300 GF.FL ±300 GF.FL

±0.000 NGL ±0.000 NGL ±0.000 NGL

PROJECT EL SUKKAH PROJECT EL SUKKAH PROJECT EL SUKKAH


FRONT ELEVATION LEFT SIDE ELEVATION RIGHT SIDE ELEVATION

ARCHITECTEDMUNDADELACRUZJR©COPYRIGHT FEB2K21
DESIGN BY: IMPORTANT: NOTE: PROJECT TITLE: OWNER/APPROVED BY: SHEET CONTENT: SHEET NO.:

DRAWN BY:
EDMUND A. DELA CRUZ Jr, UAP
Ar.EDMUND A. DELA CRUZ Jr., UAP,RMP ARCHITECT
DATE:

CHECKED BY:
Drawings and specifications duly signed, sealed or stamped, as
instruments of service, are the intellectual property and documents of
the ARCHITECT, whether the object for which they are made is
executed or not. It shall be unlawful for any person to duplicate or to
All measurements must be verified at the site
before construction. Contractors shall notify the
Architect/Designer of any discrepancy before
commencement of work, Architect/Designer Shall
P R O J E C T E L S U K K A H A101
PRC NO. : IAPOA NO. : DATE: OF:
A R C H I T E C T / M A S T E R P L U M B E R make copies of said documents for use in the repetition of and for other not be held responsible for any errors should the P R O P O S E D T W O - S T O R E Y R E S I D E N T I A L B U I L D I N G
REGISTRATION DATE: VALID UNTIL : PROJECT NO.: projects or buildings, whether executed partly or in whole, without the contractor fail to observe this procedure. The MR. AND MRS. VICENTE J.
2 4
written consent of the architect or author of said documents. contractor shall be responsible for any errors
VALID UNTIL: PTR NO. : REVISION:
R.A.9266; Sec.33 resulting from failure to do so. S A N T I A S J R .
est.2016 ADD.: TUGUEGARAO CITY CONTACT NO.: +63956-978-3534 E-MAIL: delacruzedmundjr@gmail.com TIN NO. : DATE ISSUED : STATUS: LOCATION: ANNAFUNAN WEST, TUGUEGARAO CITY, CAGAYAN

You might also like