Professional Documents
Culture Documents
rb1 Building
rb1 Building
PROJECT ADDRESS:
MOUZA-NAWRA PLOT NO.-16-506-016, SECTOR-16 JALSHIRI ABASHON, RUPGONJ,
NARAYANGONJ, BANGLADESH.
NAME OF THE CLIENT:
MD.MAMUN MIAH
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Contents
ABSTRACT .................................................................................................................................... 3
1.0 INTRODUCTION: ...................................................................................................................... 4
2.0 SCOPE OF WORK: .................................................................................................................... 4
3.0 METHODOLOGY: ...................................................................................................................... 4
4.0 MATERIAL SPECIFICATIONS: .................................................................................................... 4
5.0 DETAILS OF FOUNDATION SYSTEM: .......................................................................................... 5
6.0 LOAD APPLIED ON STRUCTURE: ............................................................................................... 5
7.0 LOAD COMBINATIONS:............................................................................................................. 5
8.0 STORY DRIFTS:...................................................................................................................... 11
9.0 MAXIMUM LATERAL DISPLACEMENT: ..................................................................................... 14
10.0 ADEQUACY CHECK OF COLUMN: .......................................................................................... 16
11.0 FOUNDATION ADEQUACY CHECK: ......................................................................................... 23
12.0 BEAM ADEQUACY CHECK: .................................................................................................... 26
13.0 ADEQUACY CHECK OF SHEAR WALL: .................................................................................... 37
14.0 SLAB ADEQUACY CHECK:..................................................................................................... 40
15.0 CONCLUSION & RECOMMENDATION: .................................................................................... 41
2
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
ABSTRACT
This structure was analyzed and designed considering B+G+8 storied office building.
Detailed Engineering Solutions prepared this design report based on Bangladesh National
Building Code 2020. All design parameters as well as seismic & wind load parameter has
been adopted according to BNBC 2020.
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
1.0 INTRODUCTION:
This proposed B+G+8 storied office building has been analyzed for different loading
conditions & different load combinations according to BNBC-2020 and ACI 318-08
standard. This report summarizes the analysis and design related data which indicates
whether the building is safe or not in proposed loading condition.
3.0 METHODOLOGY:
Based on the supplied Architectural Drawing, Structural drawing, field measurement,
material strength parameter, we developed a computer analysis model and carried out
complete analysis of the structure incorporating various design data as per Bangladesh
National Building Code (BNBC2020). Loading values is considered by Architectural Drawing
and BNBC guideline. Strength parameter of concrete and reinforcement is considered based
on existing design documents. The results obtained from computer model analysis were
checked against relevant specifications and hand calculations.
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
5.0 DETAILS OF FOUNDATION SYSTEM:
Type of foundation=20 inch dia 98’-0” long cast is situ pile
Dead load:
a) Self-weight of structure
b) Brick partition wall= as mentioned in architectural drawing
c) Floor finish =20psf
Live load:
a) Floor live load=75psf
b) Stair live load=75 psf
c) Roof live load=21 psf
Wind load:
a) Basic wind speed=61.1m/s (for Narayanganj)
b) Importance factor=1
c) Exposure Category=A
Earthquake load:
a) Seismic zone factor, Z=0.20
b) Importance factor, I=1
c) Response Modifications Factor, R=6.5
d) Soil Type SD
e) Soil Facto, S=1.35
F3 Live 0.75
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F4 Dead 1 Linear Add
F4 Wx (BNBC2020) 1
F5 Dead 1 Linear Add
F5 Wx (BNBC2020) -1
F6 Dead 1 Linear Add
F6 Wy (BNBC2020) -1
F7 Dead 1 Linear Add
F7 Wy (BNBC2020) 1
F9 Dead 1 Linear Add
F9 Ex (BNBC2020) 0.7
F9 Ey (BNBC2020) 0.21
F9 Ev 0.7
F8 Dead 1 Linear Add
F8 Ex (BNBC2020) -0.7
F8 Ey (BNBC2020) 0.21
F8 Ev 0.7
F10 Dead 1 Linear Add
F10 Ex (BNBC2020) -0.7
F10 Ey (BNBC2020) -0.21
F10 Ev 0.7
F12 Dead 1 Linear Add
F12 Ex (BNBC2020) 0.525
F12 Ey (BNBC2020) 0.1575
F12 Ev 0.525
F12 Live 0.7
F12-1 Dead 1 Linear Add
F12-1 Ex (BNBC2020) 0.525
F12-1 Ey (BNBC2020) -0.1575
F12-1 Ev 0.525
F12-1 Live 0.7
F12-2 Dead 1 Linear Add
F12-2 Ex (BNBC2020) 0.525
F12-2 Ey (BNBC2020) -0.1575
F12-2 Ev -0.525
F12-2 Live 0.7
F12-3 Dead 1 Linear Add
F12-3 Ex (BNBC2020) -0.525
F12-3 Ey (BNBC2020) -0.1575
F12-3 Ev -0.525
F12-3 Live 0.7
F12-4 Dead 1 Linear Add
F12-4 Ex (BNBC2020) -0.525
F12-4 Ey (BNBC2020) 0.1575
F12-4 Ev -0.525
F12-4 Live 0.7
F12-5 Dead 1 Linear Add
F12-5 Ex (BNBC2020) -0.525
F12-5 Ey (BNBC2020) 0.1575
6
F12-5 Ev 0.525
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F12-7 Dead 1 Linear Add
F12-7 Ey (BNBC2020) 0.525
F12-7 Ex (BNBC2020) -0.1575
F12-7 Ev 0.525
F12-7 Live 0.7
F12-8 Dead 1 Linear Add
F12-8 Ey (BNBC2020) 0.525
F12-8 Ex (BNBC2020) -0.1575
F12-8 Ev -0.525
F12-8 Live 0.7
F12-9 Dead 1 Linear Add
F12-9 Ey (BNBC2020) -0.525
F12-9 Ex (BNBC2020) -0.1575
F12-9 Ev -0.525
F12-9 Live 0.7
F12-10 Dead 1 Linear Add
F12-10 Ey (BNBC2020) -0.525
F12-10 Ex (BNBC2020) 0.1575
F12-10 Ev -0.525
F12-10 Live 0.7
F12-11 Dead 1 Linear Add
F12-11 Ey (BNBC2020) -0.525
F12-11 Ex (BNBC2020) 0.1575
F12-11 Ev 0.525
F12-11 Live 0.7
F12-12 Dead 1 Linear Add
F12-12 Wx (BNBC2020) 0.75
F12-12 Live 0.7
F12-13 Dead 1 Linear Add
F12-13 Wx (BNBC2020) -0.75
F12-13 Live 0.7
F12-14 Dead 1 Linear Add
F12-14 Wy (BNBC2020) -0.75
F12-14 Live 0.7
F12-15 Dead 1 Linear Add
F12-15 Wy (BNBC2020) 0.75
F12-15 Live 0.7
F12-16 Dead 0.6 Linear Add
F12-16 Wx (BNBC2020) 1
F12-17 Dead 0.6 Linear Add
F12-17 Wx (BNBC2020) -1
F12-18 Dead 0.6 Linear Add
F12-18 Wy (BNBC2020) -1
F12-19 Dead 0.6 Linear Add
F12-19 Wy (BNBC2020) 1
F12-20 Dead 0.6 Linear Add
F12-20 Ex (BNBC2020) 0.7
F12-20 Ey (BNBC2020) 0.21
7
F12-20 Ev 0.7
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F12-21 Ex (BNBC2020) 0.7
F12-21 Ey (BNBC2020) -0.21
F12-21 Ev 0.7
F12-22 Dead 0.6 Linear Add
F12-22 Ex (BNBC2020) 0.7
F12-22 Ey (BNBC2020) -0.21
F12-22 Ev -0.7
F12-23 Dead 0.6 Linear Add
F12-23 Ex (BNBC2020) -0.7
F12-23 Ey (BNBC2020) -0.21
F12-23 Ev -0.7
F12-24 Dead 0.6 Linear Add
F12-24 Ex (BNBC2020) -0.7
F12-24 Ey (BNBC2020) 0.21
F12-24 Ev -0.7
F12-25 Dead 0.6 Linear Add
F12-25 Ex (BNBC2020) -0.7
F12-25 Ey (BNBC2020) 0.21
F12-25 Ev 0.7
F12-26 Dead 0.6 Linear Add
F12-26 Ey (BNBC2020) -0.7
F12-26 Ex (BNBC2020) 0.21
F12-26 Ev 0.7
F12-27 Dead 0.6 Linear Add
F12-27 Ey (BNBC2020) -0.7
F12-27 Ex (BNBC2020) -0.21
F12-27 Ev -0.7
F12-28 Dead 0.6 Linear Add
F12-28 Ey (BNBC2020) -0.7
F12-28 Ex (BNBC2020) 0.21
F12-28 Ev -0.7
F12-29 Dead 0.6 Linear Add
F12-29 Ey (BNBC2020) -0.7
F12-29 Ex (BNBC2020) 0.21
F12-29 Ev 0.7
F12-30 Dead 0.6 Linear Add
F12-30 Ey (BNBC2020) -0.7
F12-30 Ex (BNBC2020) 0.21
F12-30 Ev 0.7
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
BNBC-4 Dead 1.2 Linear Add 0
BNBC-4 Wx (BNBC2020) 0.8 0
BNBC-5 Dead 1.2 Linear Add 0
BNBC-5 Wy (BNBC2020) 0.8 0
BNBC-6 Dead 1.2 Linear Add 0
BNBC-6 Wx (BNBC2020) -0.8 0
BNBC-7 Dead 1.2 Linear Add 0
BNBC-7 Wy (BNBC2020) -0.8 0
BNBC-8 Dead 1.2 Linear Add 0
BNBC-8 Live 0.5 0
BNBC-8 Wx (BNBC2020) 1.6 0
BNBC-9 Dead 1.2 Linear Add 0
BNBC-9 Live 0.5 0
BNBC-9 Wy (BNBC2020) 1.6 0
BNBC-10 Dead 1.2 Linear Add 0
BNBC-10 Live 0.5 0
BNBC-10 Wx (BNBC2020) -1.6 0
BNBC-11 Dead 1.2 Linear Add 0
BNBC-11 Live 0.5 0
BNBC-11 Wy (BNBC2020) -1.6 0
BNBC-12 Dead 1.2 Linear Add 0
BNBC-12 Live 0.5 0
BNBC-12 Ex (BNBC2020) 1 0
BNBC-12 Ev 1 0
BNBC-12 Ey (BNBC2020) 0.3 0
BNBC-13 Dead 1.2 Linear Add 0
BNBC-13 Live 0.5 0
BNBC-13 Ex (BNBC2020) 1 0
BNBC-13 Ev 1 0
BNBC-13 Ey (BNBC2020) -0.3 0
BNBC-14 Dead 1.2 Linear Add 0
BNBC-14 Live 0.5 0
BNBC-14 Ex (BNBC2020) -1 0
BNBC-14 Ev 1 0
BNBC-14 Ey (BNBC2020) 0.3 0
BNBC-15 Dead 1.2 Linear Add 0
BNBC-15 Live 0.5 0
BNBC-15 Ex (BNBC2020) -1 0
BNBC-15 Ev 1 0
BNBC-15 Ey (BNBC2020) -0.3 0
BNBC-16 Dead 1.2 Linear Add 0
BNBC-16 Live 0.5 0
BNBC-16 Ey (BNBC2020) 1 0
BNBC-16 Ev 1 0
BNBC-16 Ex (BNBC2020) 0.3 0
BNBC-17 Dead 1.2 Linear Add 0
BNBC-17 Live 0.5 0
BNBC-17 Ey (BNBC2020) 1 0
9
BNBC-17 Ev 1 0
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
BNBC-18 Dead 1.2 Linear Add 0
BNBC-18 Live 0.5 0
BNBC-18 Ey (BNBC2020) -1 0
BNBC-18 Ev 1 0
BNBC-18 Ex (BNBC2020) 0.3 0
BNBC-19 Dead 1.2 Linear Add 0
BNBC-19 Live 0.5 0
BNBC-19 Ey (BNBC2020) -1 0
BNBC-19 Ev 1 0
BNBC-19 Ex (BNBC2020) -0.3 0
BNBC-20 Dead 0.9 Linear Add 0
BNBC-20 Wx (BNBC2020) 1.6 0
BNBC-21 Dead 0.9 Linear Add 0
BNBC-21 Wy (BNBC2020) 1.6 0
BNBC-22 Dead 0.9 Linear Add 0
BNBC-22 Wx (BNBC2020) -1.6 0
BNBC-23 Dead 0.9 Linear Add 0
BNBC-23 Wy (BNBC2020) -1.6 0
BNBC-24 Dead 0.9 Linear Add 0
BNBC-24 Ex (BNBC2020) 1 0
BNBC-24 Ev -1 0
BNBC-24 Ey (BNBC2020) 0.3 0
BNBC-25 Dead 0.9 Linear Add 0
BNBC-25 Ex (BNBC2020) 1 0
BNBC-25 Ev -1 0
BNBC-25 Ey (BNBC2020) -0.3 0
BNBC-26 Dead 0.9 Linear Add 0
BNBC-26 Ex (BNBC2020) -1 0
BNBC-26 Ev -1 0
BNBC-26 Ey (BNBC2020) 0.3 0
BNBC-27 Dead 0.9 Linear Add 0
BNBC-27 Ex (BNBC2020) -1 0
BNBC-27 Ev -1 0
BNBC-27 Ey (BNBC2020) -0.3 0
BNBC-28 Dead 0.9 Linear Add 0
BNBC-28 Ey (BNBC2020) 1 0
BNBC-28 Ev -1 0
BNBC-28 Ex (BNBC2020) 0.3 0
BNBC-29 Dead 0.9 Linear Add 0
BNBC-29 Ey (BNBC2020) 1 0
BNBC-29 Ev -1 0
BNBC-29 Ex (BNBC2020) -0.3 0
BNBC-30 Dead 0.9 Linear Add 0
BNBC-30 Ey (BNBC2020) -1 0
BNBC-30 Ev -1 0
BNBC-30 Ex (BNBC2020) 0.3 0
BNBC-31 Dead 0.9 Linear Add 0
10
BNBC-31 Ey (BNBC2020) -1 0
BNBC-31 Ev -1 0
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
7.3 load combinations for lateral displacement:
Load Combinations
Name Load Case/Combo Scale Factor Type Auto
DL+0.5LL+0.7Wx Dead 1 Linear Add 0
DL+0.5LL+0.7Wx Live 1 0
DL+0.5LL+0.7Wx Wx (BNBC2020) 1 0
DL+0.5LL-0.7Wx Dead 1 Linear Add 0
DL+0.5LL-0.7Wx Live 1 0
DL+0.5LL-0.7Wx Wx (BNBC2020) -1 0
DL+0.5LL+0.7Wy Dead 1 Linear Add 0
DL+0.5LL+0.7Wy Live 1 0
DL+0.5LL+0.7Wy Wy (BNBC2020) 1 0
DL+0.5LL-0.7Wy Dead 1 Linear Add 0
DL+0.5LL-0.7Wy Live 1 0
DL+0.5LL-0.7Wy Wy (BNBC2020) -1 0
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
EQX:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
EQY:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
9.0 MAXIMUM LATERAL DISPLACEMENT:
For lateral displacement the following load combination has been considered
Load combination= DL+0.5LL+0.70WL (Ref. Section 2.7.5, Part-6, BNBC-2020)
Allowable displacement=h/500=113*12/500=2.712in (Ref. Section 1.5.6.2, Part-6,
BNBC-2020)
DL+0.5LL+0.7W:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
DL+0.5LL-0.7W:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
10.0 ADEQUACY CHECK OF COLUMN:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID A/A)
17
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID C/C)
18
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID E/E)
19
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Column utilization ratio
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
C5 5F C5 -4TH TO 5TH F Bottom BNBC-15 0.527 Ok
C8 5F C5 -4TH TO 5TH F Bottom BNBC-13 0.575 Ok
C9 5F C2- 4TH TO 5TH F Bottom BNBC-15 0.688 Ok
C12 5F C3- 4TH TO 5TH F Bottom BNBC-18 0.971 Ok
C13 5F C2- 4TH TO 5TH F Bottom BNBC-15 0.606 Ok
C16 5F C3- 4TH TO 5TH F Bottom BNBC-16 0.659 Ok
C21 5F C6-4TH TO 5TH F Bottom BNBC-19 0.51 Ok
C2 5F C4-4TH TO 5TH F Bottom BNBC-30 0.755 Ok
C1 4F C1-2ND TO 3RD Bottom BNBC-17 0.609 Ok
C4 4F C1-2ND TO 3RD Bottom BNBC-16 0.646 Ok
C5 4F C5- 2ND TO 3RD F Bottom BNBC-15 0.564 Ok
C8 4F C5- 2ND TO 3RD F Bottom BNBC-13 0.613 Ok
C9 4F C2- 2ND TO 3RD F Bottom BNBC-15 0.727 Ok
C12 4F C3- 2ND TO 3RD F Bottom BNBC-18 0.969 Ok
C13 4F C2- 2ND TO 3RD F Bottom BNBC-15 0.674 Ok
C16 4F C3- 2ND TO 3RD F Bottom BNBC-18 0.723 Ok
C21 4F C6 2ND TO 3RD F Bottom BNBC-18 0.559 Ok
C2 4F C4 2ND TO 3RD F Bottom BNBC-17 0.769 Ok
C1 3F C1-2ND TO 3RD Bottom BNBC-17 0.654 Ok
C4 3F C1-2ND TO 3RD Bottom BNBC-16 0.691 Ok
C5 3F C5- 2ND TO 3RD F Bottom BNBC-15 0.628 Ok
C8 3F C5- 2ND TO 3RD F Bottom BNBC-13 0.678 Ok
C9 3F C2- 2ND TO 3RD F Bottom BNBC-15 0.758 Ok
C12 3F C3- 2ND TO 3RD F Bottom BNBC-18 0.983 Ok
C13 3F C2- 2ND TO 3RD F Bottom BNBC-15 0.749 Ok
C16 3F C3- 2ND TO 3RD F Bottom BNBC-18 0.849 Ok
C21 3F C6 2ND TO 3RD F Bottom BNBC-18 0.619 Ok
C2 3F C4 2ND TO 3RD F Bottom BNBC-17 0.839 Ok
C1 2F C1-BASE TO 1ST F Bottom BNBC-17 0.67 Ok
C4 2F C1-BASE TO 1ST F Bottom BNBC-16 0.703 Ok
C5 2F C5 BASE TO 1ST F Bottom BNBC-15 0.658 Ok
C8 2F C5 BASE TO 1ST F Bottom BNBC-13 0.708 Ok
C9 2F C2- BASE TO 1ST F Bottom BNBC-15 0.761 Ok
C12 2F C3- BASE TO 1ST F Bottom BNBC-18 0.874 Ok
C13 2F C2- BASE TO 1ST F Bottom BNBC-15 0.794 Ok
C16 2F C3- BASE TO 1ST F Bottom BNBC-18 0.833 Ok
C21 2F C6-BASE TO 1ST F Bottom BNBC-18 0.644 Ok
C2 2F C4 BASE TO 1ST F Bottom BNBC-17 0.855 Ok
C1 1F C1-BASE TO 1ST F Bottom BNBC-14 0.736 Ok
C4 1F C1-BASE TO 1ST F Bottom BNBC-13 0.768 Ok
C5 1F C5 BASE TO 1ST F Bottom BNBC-15 0.758 Ok
C8 1F C5 BASE TO 1ST F Bottom BNBC-13 0.824 Ok
C9 1F C2- BASE TO 1ST F Bottom BNBC-15 0.813 Ok
C12 1F C3- BASE TO 1ST F Bottom BNBC-13 0.883 Ok
C13 1F C2- BASE TO 1ST F Bottom BNBC-19 0.928 Ok
C16 1F C3- BASE TO 1ST F Bottom BNBC-18 0.955 Ok
21
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
C1 GF C1-BASE TO 1ST F Bottom BNBC-14 0.839 Ok
C4 GF C1-BASE TO 1ST F Bottom BNBC-13 0.945 Ok
C5 GF C5 BASE TO 1ST F Bottom BNBC-15 0.872 Ok
C8 GF C5 BASE TO 1ST F Bottom BNBC-13 0.986 Ok
C9 GF C2- BASE TO 1ST F Bottom BNBC-16 0.818 Ok
C12 GF C3- BASE TO 1ST F Bottom BNBC-12 0.868 Ok
C13 GF C2- BASE TO 1ST F Bottom BNBC-19 1.035 Ok
C16 GF C3- BASE TO 1ST F Bottom BNBC-18 1.018 Ok
C17 GF C 12X18 Bottom BNBC-31 0.01 Ok
C18 GF C 12X18 Bottom BNBC-31 0.01 Ok
C19 GF C 12X18 Bottom BNBC-31 0.01 Ok
C20 GF C 12X18 Bottom BNBC-18 0.0119 Ok
C21 GF C6-BASE TO 1ST F Bottom BNBC-13 0.831 Ok
C2 GF C4 BASE TO 1ST F Bottom BNBC-17 0.946 Ok
22
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
11.0 FOUNDATION ADEQUACY CHECK:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Pile adequacy check
Gravity load
Ultimate Capacity of
Number of Pile
DL+LL (kip)
Joint Label
REMARKS
FOS
1 2 500.0 347.2 2.88 Adequate
35 4 500.0 580.7 3.44 Adequate
4 2 500.0 367.1 2.72 Adequate
5 5 500.0 821.9 3.04 Adequate
36 8 500.0 1441.4 2.78 Adequate
8 5 500.0 870.4 2.87 Adequate
9 3 500.0 521.6 2.88 Adequate
13 3 500.0 526.5 2.85 Adequate
12 817.9
9 500.0 2.71 Adequate
16 843.5
10 118.1
40 71.6
42 133.3
37 133.4
38 100.1
11 141.9
59 129.0
181 167.6
66 17 500.0 136.2 2.76 Adequate
177 174.0
70 147.1
173 184.7
14 239.8
122 287.5
126 301.5
130 319.8
15 288.6
24
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Capacity of each pile = 200.00 kip (FOS= 2.50 )
Ultimate Capacity
of each Pile (kip)
Number of Pile
BNBC Combo
Joint Label
REMARKS
(kip)
FOS
1 3 500.0 439.9 3.41 Adequate
35 4 500.0 786.1 2.54 Adequate
4 3 500.0 451.9 3.32 Adequate
5 5 500.0 821.9 3.04 Adequate
36 8 500.0 1445.6 2.77 Adequate
8 5 500.0 909.0 2.75 Adequate
9 644.4
7 500.0 2.64 Adequate
13 679.6
12 903.9
10 500.0 2.57 Adequate
16 1040.2
10
40
42
37
38
11
59
181
66 17 500.0 3186.5 2.67 Adequate
177
70
173
14
122
126
130
15
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
12.0 BEAM ADEQUACY CHECK:
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 1st floor beam
27
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 2nd floor beam
28
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 3rd floor beam
29
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 4th floor beam
30
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 5th floor beam
31
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 6th floor beam
32
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 7th floor beam
33
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 8th floor beam
34
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) Roof floor beam
35
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) Roof top beam
Comments: Provided reinforcement is greater than required reinforcement.
36
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
13.0 ADEQUACY CHECK OF SHEAR WALL:
Flexural reinforcement check
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Flexural adequacy of shear wall
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
3F P1 Bottom SW 2F to 3F 0.333 Adequate
3F P1 Bottom SW 2F to 3F 0.333 Adequate
3F P1 Bottom SW 2F to 3F 0.333 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
39
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
14.0 SLAB ADEQUACY CHECK:
Calculation for two way slab
Slab Panel C-D/2-3 (Interior Panel, 1st Floor)
Required Reinforcement
0.30 0.16 0.16 0.16
(in)
Provided Reinforcement
0.48 0.43 0.44 0.29
(in)
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
15.0 CONCLUSION & RECOMMENDATION:
We performed analysis and design and the following observation has been found-
All members has been checked considering BNBC-2020 Standard.
All column and beam members are adequate to resist applied gravity and lateral
load.
Number of pile are sufficient to carry the total superimposed load.
Floor slab are capable to carry applied load.
Serviceability (drift, lateral displacement,) are within allowable limit.
Thanking You
Attachment:
1.0 Soil test report
41
Page
ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206