DESIGN REPORT OF PROPOSED B+G+8 STORIED OFFICE BUILDING.

PROJECT ADDRESS:
MOUZA-NAWRA PLOT NO.-16-506-016, SECTOR-16 JALSHIRI ABASHON, RUPGONJ,
NARAYANGONJ, BANGLADESH.
NAME OF THE CLIENT:
MD.MAMUN MIAH

Date of submission: 20th February 2024

Name of the Submitting Engineer


Engr. Abdul Jabber Miah
B.Sc. Engg. (Civil, DUET)
DMINB/CE-0460; MIEB-31825
CEO & Structural Engineer
1

Detailed Engineering Solution (DES)


Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Contents
ABSTRACT .................................................................................................................................... 3
1.0 INTRODUCTION: ...................................................................................................................... 4
2.0 SCOPE OF WORK: .................................................................................................................... 4
3.0 METHODOLOGY: ...................................................................................................................... 4
4.0 MATERIAL SPECIFICATIONS: .................................................................................................... 4
5.0 DETAILS OF FOUNDATION SYSTEM: .......................................................................................... 5
6.0 LOAD APPLIED ON STRUCTURE: ............................................................................................... 5
7.0 LOAD COMBINATIONS:............................................................................................................. 5
8.0 STORY DRIFTS:...................................................................................................................... 11
9.0 MAXIMUM LATERAL DISPLACEMENT: ..................................................................................... 14
10.0 ADEQUACY CHECK OF COLUMN: .......................................................................................... 16
11.0 FOUNDATION ADEQUACY CHECK: ......................................................................................... 23
12.0 BEAM ADEQUACY CHECK: .................................................................................................... 26
13.0 ADEQUACY CHECK OF SHEAR WALL: .................................................................................... 37
14.0 SLAB ADEQUACY CHECK:..................................................................................................... 40
15.0 CONCLUSION & RECOMMENDATION: .................................................................................... 41
2
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
ABSTRACT

This structure was analyzed and designed considering B+G+8 storied office building.
Detailed Engineering Solutions prepared this design report based on Bangladesh National
Building Code 2020. All design parameters as well as seismic & wind load parameter has
been adopted according to BNBC 2020.

End of the analysis we have found the followings:

 All members has been checked considering BNBC-2020 Standard.


 All column and beam members are adequate to resist applied gravity and lateral
load.
 Number of pile are sufficient to carry the total superimposed load.
 Floor slab are capable to carry applied load.
 Serviceability (drift, lateral displacement,) are within allowable limit.
3
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
1.0 INTRODUCTION:
This proposed B+G+8 storied office building has been analyzed for different loading
conditions & different load combinations according to BNBC-2020 and ACI 318-08
standard. This report summarizes the analysis and design related data which indicates
whether the building is safe or not in proposed loading condition.

2.0 SCOPE OF WORK:


The scope of the works as follows-
i) Analysis the RCC Structure
ii) Reporting of RCC Structure based on Structural working drawing by Analysis and
Design.

3.0 METHODOLOGY:
Based on the supplied Architectural Drawing, Structural drawing, field measurement,
material strength parameter, we developed a computer analysis model and carried out
complete analysis of the structure incorporating various design data as per Bangladesh
National Building Code (BNBC2020). Loading values is considered by Architectural Drawing
and BNBC guideline. Strength parameter of concrete and reinforcement is considered based
on existing design documents. The results obtained from computer model analysis were
checked against relevant specifications and hand calculations.

4.0 MATERIAL SPECIFICATIONS:


i) Design Strength of concrete, f’c
-Column & Shear Wall (4000 psi) based on Structural drawing
-Beam (3500 psi) based on Structural drawing
-Slab (3500 psi) based on Structural drawing
ii) Yield Strength of reinforcement, fy
-Column (72500 psi) based on Structural drawing
4

-Shear Wall (60000 psi) based on Structural drawing


Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
5.0 DETAILS OF FOUNDATION SYSTEM:
Type of foundation=20 inch dia 98’-0” long cast is situ pile

6.0 LOAD APPLIED ON STRUCTURE:

Dead load:
a) Self-weight of structure
b) Brick partition wall= as mentioned in architectural drawing
c) Floor finish =20psf

Live load:
a) Floor live load=75psf
b) Stair live load=75 psf
c) Roof live load=21 psf

Wind load:
a) Basic wind speed=61.1m/s (for Narayanganj)
b) Importance factor=1
c) Exposure Category=A

Earthquake load:
a) Seismic zone factor, Z=0.20
b) Importance factor, I=1
c) Response Modifications Factor, R=6.5
d) Soil Type SD
e) Soil Facto, S=1.35

7.0 LOAD COMBINATIONS:

7.1 load combinations for foundation checking:

Name Load Case/Combo Scale Factor Type


D+L Dead 1 Linear Add
D+L Live 1
F1 Dead 1 Linear Add
F2 Dead 1 Linear Add
F2 Live 1
5

F3 Dead 1 Linear Add


Page

F3 Live 0.75

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F4 Dead 1 Linear Add
F4 Wx (BNBC2020) 1
F5 Dead 1 Linear Add
F5 Wx (BNBC2020) -1
F6 Dead 1 Linear Add
F6 Wy (BNBC2020) -1
F7 Dead 1 Linear Add
F7 Wy (BNBC2020) 1
F9 Dead 1 Linear Add
F9 Ex (BNBC2020) 0.7
F9 Ey (BNBC2020) 0.21
F9 Ev 0.7
F8 Dead 1 Linear Add
F8 Ex (BNBC2020) -0.7
F8 Ey (BNBC2020) 0.21
F8 Ev 0.7
F10 Dead 1 Linear Add
F10 Ex (BNBC2020) -0.7
F10 Ey (BNBC2020) -0.21
F10 Ev 0.7
F12 Dead 1 Linear Add
F12 Ex (BNBC2020) 0.525
F12 Ey (BNBC2020) 0.1575
F12 Ev 0.525
F12 Live 0.7
F12-1 Dead 1 Linear Add
F12-1 Ex (BNBC2020) 0.525
F12-1 Ey (BNBC2020) -0.1575
F12-1 Ev 0.525
F12-1 Live 0.7
F12-2 Dead 1 Linear Add
F12-2 Ex (BNBC2020) 0.525
F12-2 Ey (BNBC2020) -0.1575
F12-2 Ev -0.525
F12-2 Live 0.7
F12-3 Dead 1 Linear Add
F12-3 Ex (BNBC2020) -0.525
F12-3 Ey (BNBC2020) -0.1575
F12-3 Ev -0.525
F12-3 Live 0.7
F12-4 Dead 1 Linear Add
F12-4 Ex (BNBC2020) -0.525
F12-4 Ey (BNBC2020) 0.1575
F12-4 Ev -0.525
F12-4 Live 0.7
F12-5 Dead 1 Linear Add
F12-5 Ex (BNBC2020) -0.525
F12-5 Ey (BNBC2020) 0.1575
6

F12-5 Ev 0.525
Page

F12-5 Live 0.7

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F12-7 Dead 1 Linear Add
F12-7 Ey (BNBC2020) 0.525
F12-7 Ex (BNBC2020) -0.1575
F12-7 Ev 0.525
F12-7 Live 0.7
F12-8 Dead 1 Linear Add
F12-8 Ey (BNBC2020) 0.525
F12-8 Ex (BNBC2020) -0.1575
F12-8 Ev -0.525
F12-8 Live 0.7
F12-9 Dead 1 Linear Add
F12-9 Ey (BNBC2020) -0.525
F12-9 Ex (BNBC2020) -0.1575
F12-9 Ev -0.525
F12-9 Live 0.7
F12-10 Dead 1 Linear Add
F12-10 Ey (BNBC2020) -0.525
F12-10 Ex (BNBC2020) 0.1575
F12-10 Ev -0.525
F12-10 Live 0.7
F12-11 Dead 1 Linear Add
F12-11 Ey (BNBC2020) -0.525
F12-11 Ex (BNBC2020) 0.1575
F12-11 Ev 0.525
F12-11 Live 0.7
F12-12 Dead 1 Linear Add
F12-12 Wx (BNBC2020) 0.75
F12-12 Live 0.7
F12-13 Dead 1 Linear Add
F12-13 Wx (BNBC2020) -0.75
F12-13 Live 0.7
F12-14 Dead 1 Linear Add
F12-14 Wy (BNBC2020) -0.75
F12-14 Live 0.7
F12-15 Dead 1 Linear Add
F12-15 Wy (BNBC2020) 0.75
F12-15 Live 0.7
F12-16 Dead 0.6 Linear Add
F12-16 Wx (BNBC2020) 1
F12-17 Dead 0.6 Linear Add
F12-17 Wx (BNBC2020) -1
F12-18 Dead 0.6 Linear Add
F12-18 Wy (BNBC2020) -1
F12-19 Dead 0.6 Linear Add
F12-19 Wy (BNBC2020) 1
F12-20 Dead 0.6 Linear Add
F12-20 Ex (BNBC2020) 0.7
F12-20 Ey (BNBC2020) 0.21
7

F12-20 Ev 0.7
Page

F12-21 Dead 0.6 Linear Add

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
F12-21 Ex (BNBC2020) 0.7
F12-21 Ey (BNBC2020) -0.21
F12-21 Ev 0.7
F12-22 Dead 0.6 Linear Add
F12-22 Ex (BNBC2020) 0.7
F12-22 Ey (BNBC2020) -0.21
F12-22 Ev -0.7
F12-23 Dead 0.6 Linear Add
F12-23 Ex (BNBC2020) -0.7
F12-23 Ey (BNBC2020) -0.21
F12-23 Ev -0.7
F12-24 Dead 0.6 Linear Add
F12-24 Ex (BNBC2020) -0.7
F12-24 Ey (BNBC2020) 0.21
F12-24 Ev -0.7
F12-25 Dead 0.6 Linear Add
F12-25 Ex (BNBC2020) -0.7
F12-25 Ey (BNBC2020) 0.21
F12-25 Ev 0.7
F12-26 Dead 0.6 Linear Add
F12-26 Ey (BNBC2020) -0.7
F12-26 Ex (BNBC2020) 0.21
F12-26 Ev 0.7
F12-27 Dead 0.6 Linear Add
F12-27 Ey (BNBC2020) -0.7
F12-27 Ex (BNBC2020) -0.21
F12-27 Ev -0.7
F12-28 Dead 0.6 Linear Add
F12-28 Ey (BNBC2020) -0.7
F12-28 Ex (BNBC2020) 0.21
F12-28 Ev -0.7
F12-29 Dead 0.6 Linear Add
F12-29 Ey (BNBC2020) -0.7
F12-29 Ex (BNBC2020) 0.21
F12-29 Ev 0.7
F12-30 Dead 0.6 Linear Add
F12-30 Ey (BNBC2020) -0.7
F12-30 Ex (BNBC2020) 0.21
F12-30 Ev 0.7

7.2 load combinations for structural member checking:


Name Load Case/Combo Scale Factor Type Auto
BNBC-1 Dead 1.4 Linear Add 0
BNBC-2 Dead 1.2 Linear Add 0
BNBC-2 Live 1.6 0
8

BNBC-3 Dead 1.2 Linear Add 0


Page

BNBC-3 Live 0.5 0

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
BNBC-4 Dead 1.2 Linear Add 0
BNBC-4 Wx (BNBC2020) 0.8 0
BNBC-5 Dead 1.2 Linear Add 0
BNBC-5 Wy (BNBC2020) 0.8 0
BNBC-6 Dead 1.2 Linear Add 0
BNBC-6 Wx (BNBC2020) -0.8 0
BNBC-7 Dead 1.2 Linear Add 0
BNBC-7 Wy (BNBC2020) -0.8 0
BNBC-8 Dead 1.2 Linear Add 0
BNBC-8 Live 0.5 0
BNBC-8 Wx (BNBC2020) 1.6 0
BNBC-9 Dead 1.2 Linear Add 0
BNBC-9 Live 0.5 0
BNBC-9 Wy (BNBC2020) 1.6 0
BNBC-10 Dead 1.2 Linear Add 0
BNBC-10 Live 0.5 0
BNBC-10 Wx (BNBC2020) -1.6 0
BNBC-11 Dead 1.2 Linear Add 0
BNBC-11 Live 0.5 0
BNBC-11 Wy (BNBC2020) -1.6 0
BNBC-12 Dead 1.2 Linear Add 0
BNBC-12 Live 0.5 0
BNBC-12 Ex (BNBC2020) 1 0
BNBC-12 Ev 1 0
BNBC-12 Ey (BNBC2020) 0.3 0
BNBC-13 Dead 1.2 Linear Add 0
BNBC-13 Live 0.5 0
BNBC-13 Ex (BNBC2020) 1 0
BNBC-13 Ev 1 0
BNBC-13 Ey (BNBC2020) -0.3 0
BNBC-14 Dead 1.2 Linear Add 0
BNBC-14 Live 0.5 0
BNBC-14 Ex (BNBC2020) -1 0
BNBC-14 Ev 1 0
BNBC-14 Ey (BNBC2020) 0.3 0
BNBC-15 Dead 1.2 Linear Add 0
BNBC-15 Live 0.5 0
BNBC-15 Ex (BNBC2020) -1 0
BNBC-15 Ev 1 0
BNBC-15 Ey (BNBC2020) -0.3 0
BNBC-16 Dead 1.2 Linear Add 0
BNBC-16 Live 0.5 0
BNBC-16 Ey (BNBC2020) 1 0
BNBC-16 Ev 1 0
BNBC-16 Ex (BNBC2020) 0.3 0
BNBC-17 Dead 1.2 Linear Add 0
BNBC-17 Live 0.5 0
BNBC-17 Ey (BNBC2020) 1 0
9

BNBC-17 Ev 1 0
Page

BNBC-17 Ex (BNBC2020) -0.3 0

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
BNBC-18 Dead 1.2 Linear Add 0
BNBC-18 Live 0.5 0
BNBC-18 Ey (BNBC2020) -1 0
BNBC-18 Ev 1 0
BNBC-18 Ex (BNBC2020) 0.3 0
BNBC-19 Dead 1.2 Linear Add 0
BNBC-19 Live 0.5 0
BNBC-19 Ey (BNBC2020) -1 0
BNBC-19 Ev 1 0
BNBC-19 Ex (BNBC2020) -0.3 0
BNBC-20 Dead 0.9 Linear Add 0
BNBC-20 Wx (BNBC2020) 1.6 0
BNBC-21 Dead 0.9 Linear Add 0
BNBC-21 Wy (BNBC2020) 1.6 0
BNBC-22 Dead 0.9 Linear Add 0
BNBC-22 Wx (BNBC2020) -1.6 0
BNBC-23 Dead 0.9 Linear Add 0
BNBC-23 Wy (BNBC2020) -1.6 0
BNBC-24 Dead 0.9 Linear Add 0
BNBC-24 Ex (BNBC2020) 1 0
BNBC-24 Ev -1 0
BNBC-24 Ey (BNBC2020) 0.3 0
BNBC-25 Dead 0.9 Linear Add 0
BNBC-25 Ex (BNBC2020) 1 0
BNBC-25 Ev -1 0
BNBC-25 Ey (BNBC2020) -0.3 0
BNBC-26 Dead 0.9 Linear Add 0
BNBC-26 Ex (BNBC2020) -1 0
BNBC-26 Ev -1 0
BNBC-26 Ey (BNBC2020) 0.3 0
BNBC-27 Dead 0.9 Linear Add 0
BNBC-27 Ex (BNBC2020) -1 0
BNBC-27 Ev -1 0
BNBC-27 Ey (BNBC2020) -0.3 0
BNBC-28 Dead 0.9 Linear Add 0
BNBC-28 Ey (BNBC2020) 1 0
BNBC-28 Ev -1 0
BNBC-28 Ex (BNBC2020) 0.3 0
BNBC-29 Dead 0.9 Linear Add 0
BNBC-29 Ey (BNBC2020) 1 0
BNBC-29 Ev -1 0
BNBC-29 Ex (BNBC2020) -0.3 0
BNBC-30 Dead 0.9 Linear Add 0
BNBC-30 Ey (BNBC2020) -1 0
BNBC-30 Ev -1 0
BNBC-30 Ex (BNBC2020) 0.3 0
BNBC-31 Dead 0.9 Linear Add 0
10

BNBC-31 Ey (BNBC2020) -1 0
BNBC-31 Ev -1 0
Page

BNBC-31 Ex (BNBC2020) -0.3 0

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
7.3 load combinations for lateral displacement:
Load Combinations
Name Load Case/Combo Scale Factor Type Auto
DL+0.5LL+0.7Wx Dead 1 Linear Add 0
DL+0.5LL+0.7Wx Live 1 0
DL+0.5LL+0.7Wx Wx (BNBC2020) 1 0
DL+0.5LL-0.7Wx Dead 1 Linear Add 0
DL+0.5LL-0.7Wx Live 1 0
DL+0.5LL-0.7Wx Wx (BNBC2020) -1 0
DL+0.5LL+0.7Wy Dead 1 Linear Add 0
DL+0.5LL+0.7Wy Live 1 0
DL+0.5LL+0.7Wy Wy (BNBC2020) 1 0
DL+0.5LL-0.7Wy Dead 1 Linear Add 0
DL+0.5LL-0.7Wy Live 1 0
DL+0.5LL-0.7Wy Wy (BNBC2020) -1 0

8.0 STORY DRIFTS:


Section 1.5.6.1 part 6 of BNBC 2020 (also ASCE-7-05) will be adapted to calculate drift.
Story drift limit, Δ shall be determined as follows:
∆ ≤ 0.005ℎ 𝑓𝑜𝑟 𝑇 < 0.70 𝑠𝑒𝑐𝑜𝑛𝑑
∆ ≤ 0.004ℎ 𝑓𝑜𝑟 𝑇 ≥ 0.70 𝑠𝑒𝑐𝑜𝑛𝑑
Where,
H =Height of the building in meter.
Period T is the same as used in calculation of earthquake loads.
T=Ct*(hn)m
=0.0488*(37.96)0.75=0.746 sec >0.7 sec

Allowable drift ratio =0.004


11
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
EQX:

Maximum drift=0.004≈0.004; Hence okay


12
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
EQY:

Maximum drift=0.004≈0.004; Hence okay


13
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
9.0 MAXIMUM LATERAL DISPLACEMENT:
For lateral displacement the following load combination has been considered
Load combination= DL+0.5LL+0.70WL (Ref. Section 2.7.5, Part-6, BNBC-2020)
Allowable displacement=h/500=113*12/500=2.712in (Ref. Section 1.5.6.2, Part-6,
BNBC-2020)

DL+0.5LL+0.7W:

Maximum displacement=1.36in<2.712 in; Hence okay


14
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
DL+0.5LL-0.7W:

Maximum displacement=0.57in<2.712 in; Hence okay


15
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
10.0 ADEQUACY CHECK OF COLUMN:

Fig: Column Label Number


16
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID A/A)
17
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID C/C)
18
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Column Utilization ratio (GRID E/E)
19
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Column utilization ratio

PMM PMM Ratio


Label Story Section Location Comment
Combo or Rebar %
C12 ROOF TOP C3- 6 TH TO TOP F Bottom BNBC-19 0.649 Ok
C16 ROOF TOP C3- 6 TH TO TOP F Bottom BNBC-16 0.483 Ok
C1 ROOF C1-6TH TO TOP Bottom BNBC-17 0.517 Ok
C4 ROOF C1-6TH TO TOP Bottom BNBC-16 0.583 Ok
C5 ROOF C5 6TH TOP Bottom BNBC-17 0.435 Ok
C8 ROOF C5 6TH TOP Bottom BNBC-16 0.516 Ok
C9 ROOF C2- 6TH TO TOP Bottom BNBC-15 0.556 Ok
C12 ROOF C3- 6 TH TO TOP F Bottom BNBC-19 0.68 Ok
C13 ROOF C2- 6TH TO TOP Bottom BNBC-14 0.544 Ok
C16 ROOF C3- 6 TH TO TOP F Bottom BNBC-12 0.497 Ok
C21 ROOF C6-6TH TO TOP Bottom BNBC-31 0.358 Ok
C2 ROOF C4- 6TH TOP Bottom BNBC-30 0.553 Ok
C1 8F C1-6TH TO TOP Bottom BNBC-17 0.455 Ok
C4 8F C1-6TH TO TOP Bottom BNBC-16 0.499 Ok
C5 8F C5 6TH TOP Bottom BNBC-17 0.396 Ok
C8 8F C5 6TH TOP Bottom BNBC-16 0.447 Ok
C9 8F C2- 6TH TO TOP Bottom BNBC-15 0.523 Ok
C12 8F C3- 6 TH TO TOP F Bottom BNBC-18 0.741 Ok
C13 8F C2- 6TH TO TOP Bottom BNBC-15 0.466 Ok
C16 8F C3- 6 TH TO TOP F Bottom BNBC-16 0.552 Ok
C21 8F C6-6TH TO TOP Bottom BNBC-19 0.317 Ok
C2 8F C4- 6TH TOP Bottom BNBC-30 0.573 Ok
C1 7F C1-6TH TO TOP Bottom BNBC-17 0.532 Ok
C4 7F C1-6TH TO TOP Bottom BNBC-16 0.579 Ok
C5 7F C5 6TH TOP Bottom BNBC-17 0.452 Ok
C8 7F C5 6TH TOP Bottom BNBC-16 0.51 Ok
C9 7F C2- 6TH TO TOP Bottom BNBC-15 0.616 Ok
C12 7F C3- 6 TH TO TOP F Bottom BNBC-18 0.86 Ok
C13 7F C2- 6TH TO TOP Bottom BNBC-15 0.508 Ok
C16 7F C3- 6 TH TO TOP F Bottom BNBC-16 0.602 Ok
C21 7F C6-6TH TO TOP Bottom BNBC-19 0.393 Ok
C2 7F C4- 6TH TOP Bottom BNBC-30 0.688 Ok
C1 6F C1-4TH TO 5TH F Bottom BNBC-17 0.547 Ok
C4 6F C1-4TH TO 5TH F Bottom BNBC-16 0.589 Ok
C5 6F C5 -4TH TO 5TH F Bottom BNBC-17 0.468 Ok
C8 6F C5 -4TH TO 5TH F Bottom BNBC-16 0.519 Ok
C9 6F C2- 4TH TO 5TH F Bottom BNBC-15 0.642 Ok
C12 6F C3- 4TH TO 5TH F Bottom BNBC-18 0.897 Ok
C13 6F C2- 4TH TO 5TH F Bottom BNBC-15 0.536 Ok
C16 6F C3- 4TH TO 5TH F Bottom BNBC-16 0.611 Ok
C21 6F C6-4TH TO 5TH F Bottom BNBC-19 0.434 Ok
20

C2 6F C4-4TH TO 5TH F Bottom BNBC-30 0.668 Ok


C1 5F C1-4TH TO 5TH F Bottom BNBC-17 0.589 Ok
Page

C4 5F C1-4TH TO 5TH F Bottom BNBC-16 0.629 Ok

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
C5 5F C5 -4TH TO 5TH F Bottom BNBC-15 0.527 Ok
C8 5F C5 -4TH TO 5TH F Bottom BNBC-13 0.575 Ok
C9 5F C2- 4TH TO 5TH F Bottom BNBC-15 0.688 Ok
C12 5F C3- 4TH TO 5TH F Bottom BNBC-18 0.971 Ok
C13 5F C2- 4TH TO 5TH F Bottom BNBC-15 0.606 Ok
C16 5F C3- 4TH TO 5TH F Bottom BNBC-16 0.659 Ok
C21 5F C6-4TH TO 5TH F Bottom BNBC-19 0.51 Ok
C2 5F C4-4TH TO 5TH F Bottom BNBC-30 0.755 Ok
C1 4F C1-2ND TO 3RD Bottom BNBC-17 0.609 Ok
C4 4F C1-2ND TO 3RD Bottom BNBC-16 0.646 Ok
C5 4F C5- 2ND TO 3RD F Bottom BNBC-15 0.564 Ok
C8 4F C5- 2ND TO 3RD F Bottom BNBC-13 0.613 Ok
C9 4F C2- 2ND TO 3RD F Bottom BNBC-15 0.727 Ok
C12 4F C3- 2ND TO 3RD F Bottom BNBC-18 0.969 Ok
C13 4F C2- 2ND TO 3RD F Bottom BNBC-15 0.674 Ok
C16 4F C3- 2ND TO 3RD F Bottom BNBC-18 0.723 Ok
C21 4F C6 2ND TO 3RD F Bottom BNBC-18 0.559 Ok
C2 4F C4 2ND TO 3RD F Bottom BNBC-17 0.769 Ok
C1 3F C1-2ND TO 3RD Bottom BNBC-17 0.654 Ok
C4 3F C1-2ND TO 3RD Bottom BNBC-16 0.691 Ok
C5 3F C5- 2ND TO 3RD F Bottom BNBC-15 0.628 Ok
C8 3F C5- 2ND TO 3RD F Bottom BNBC-13 0.678 Ok
C9 3F C2- 2ND TO 3RD F Bottom BNBC-15 0.758 Ok
C12 3F C3- 2ND TO 3RD F Bottom BNBC-18 0.983 Ok
C13 3F C2- 2ND TO 3RD F Bottom BNBC-15 0.749 Ok
C16 3F C3- 2ND TO 3RD F Bottom BNBC-18 0.849 Ok
C21 3F C6 2ND TO 3RD F Bottom BNBC-18 0.619 Ok
C2 3F C4 2ND TO 3RD F Bottom BNBC-17 0.839 Ok
C1 2F C1-BASE TO 1ST F Bottom BNBC-17 0.67 Ok
C4 2F C1-BASE TO 1ST F Bottom BNBC-16 0.703 Ok
C5 2F C5 BASE TO 1ST F Bottom BNBC-15 0.658 Ok
C8 2F C5 BASE TO 1ST F Bottom BNBC-13 0.708 Ok
C9 2F C2- BASE TO 1ST F Bottom BNBC-15 0.761 Ok
C12 2F C3- BASE TO 1ST F Bottom BNBC-18 0.874 Ok
C13 2F C2- BASE TO 1ST F Bottom BNBC-15 0.794 Ok
C16 2F C3- BASE TO 1ST F Bottom BNBC-18 0.833 Ok
C21 2F C6-BASE TO 1ST F Bottom BNBC-18 0.644 Ok
C2 2F C4 BASE TO 1ST F Bottom BNBC-17 0.855 Ok
C1 1F C1-BASE TO 1ST F Bottom BNBC-14 0.736 Ok
C4 1F C1-BASE TO 1ST F Bottom BNBC-13 0.768 Ok
C5 1F C5 BASE TO 1ST F Bottom BNBC-15 0.758 Ok
C8 1F C5 BASE TO 1ST F Bottom BNBC-13 0.824 Ok
C9 1F C2- BASE TO 1ST F Bottom BNBC-15 0.813 Ok
C12 1F C3- BASE TO 1ST F Bottom BNBC-13 0.883 Ok
C13 1F C2- BASE TO 1ST F Bottom BNBC-19 0.928 Ok
C16 1F C3- BASE TO 1ST F Bottom BNBC-18 0.955 Ok
21

C21 1F C6-BASE TO 1ST F Bottom BNBC-18 0.68 Ok


Page

C2 1F C4 BASE TO 1ST F Bottom BNBC-17 0.902 Ok

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
C1 GF C1-BASE TO 1ST F Bottom BNBC-14 0.839 Ok
C4 GF C1-BASE TO 1ST F Bottom BNBC-13 0.945 Ok
C5 GF C5 BASE TO 1ST F Bottom BNBC-15 0.872 Ok
C8 GF C5 BASE TO 1ST F Bottom BNBC-13 0.986 Ok
C9 GF C2- BASE TO 1ST F Bottom BNBC-16 0.818 Ok
C12 GF C3- BASE TO 1ST F Bottom BNBC-12 0.868 Ok
C13 GF C2- BASE TO 1ST F Bottom BNBC-19 1.035 Ok
C16 GF C3- BASE TO 1ST F Bottom BNBC-18 1.018 Ok
C17 GF C 12X18 Bottom BNBC-31 0.01 Ok
C18 GF C 12X18 Bottom BNBC-31 0.01 Ok
C19 GF C 12X18 Bottom BNBC-31 0.01 Ok
C20 GF C 12X18 Bottom BNBC-18 0.0119 Ok
C21 GF C6-BASE TO 1ST F Bottom BNBC-13 0.831 Ok
C2 GF C4 BASE TO 1ST F Bottom BNBC-17 0.946 Ok
22
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
11.0 FOUNDATION ADEQUACY CHECK:

Fig: Support Joint label


23
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Pile adequacy check

Capacity of each pile = 200.00 kip (FOS= 2.50 )

Gravity load

Ultimate Capacity of
Number of Pile

each Pile (kip)

DL+LL (kip)
Joint Label

REMARKS
FOS
1 2 500.0 347.2 2.88 Adequate
35 4 500.0 580.7 3.44 Adequate
4 2 500.0 367.1 2.72 Adequate
5 5 500.0 821.9 3.04 Adequate
36 8 500.0 1441.4 2.78 Adequate
8 5 500.0 870.4 2.87 Adequate
9 3 500.0 521.6 2.88 Adequate
13 3 500.0 526.5 2.85 Adequate
12 817.9
9 500.0 2.71 Adequate
16 843.5
10 118.1
40 71.6
42 133.3
37 133.4
38 100.1
11 141.9
59 129.0
181 167.6
66 17 500.0 136.2 2.76 Adequate
177 174.0
70 147.1
173 184.7
14 239.8
122 287.5
126 301.5
130 319.8
15 288.6
24
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Capacity of each pile = 200.00 kip (FOS= 2.50 )

Ultimate Capacity
of each Pile (kip)
Number of Pile

BNBC Combo
Joint Label

REMARKS
(kip)

FOS
1 3 500.0 439.9 3.41 Adequate
35 4 500.0 786.1 2.54 Adequate
4 3 500.0 451.9 3.32 Adequate
5 5 500.0 821.9 3.04 Adequate
36 8 500.0 1445.6 2.77 Adequate
8 5 500.0 909.0 2.75 Adequate
9 644.4
7 500.0 2.64 Adequate
13 679.6
12 903.9
10 500.0 2.57 Adequate
16 1040.2
10
40
42
37
38
11
59
181
66 17 500.0 3186.5 2.67 Adequate
177
70
173
14
122
126
130
15

Comments: Number of pile are sufficient to carry superimposed load.


25
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
12.0 BEAM ADEQUACY CHECK:

Fig: Required Flexural reinforcement (in2) Ground Floor beam


26
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 1st floor beam
27
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 2nd floor beam
28
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 3rd floor beam
29
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 4th floor beam
30
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 5th floor beam
31
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 6th floor beam
32
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 7th floor beam
33
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) 8th floor beam
34
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) Roof floor beam
35
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Fig: Required Flexural reinforcement (in2) Roof top beam
Comments: Provided reinforcement is greater than required reinforcement.
36
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
13.0 ADEQUACY CHECK OF SHEAR WALL:
Flexural reinforcement check

Fig.: Shear wall pier level number


37
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
Table: Flexural adequacy of shear wall

Story Pier Label Station Pier Section D/C Ratio Remarks

ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate


ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate
ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate
ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate
ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate
ROOF TOP P1 Bottom SW 4F to Top 0.021 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
ROOF P1 Bottom SW 4F to Top 0.081 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
8F P1 Bottom SW 4F to Top 0.104 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
7F P1 Bottom SW 4F to Top 0.126 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
6F P1 Bottom SW 4F to Top 0.154 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
5F P1 Bottom SW 4F to Top 0.191 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
4F P1 Bottom SW 2F to 3F 0.252 Adequate
3F P1 Bottom SW 2F to 3F 0.333 Adequate
38

3F P1 Bottom SW 2F to 3F 0.333 Adequate


Page

3F P1 Bottom SW 2F to 3F 0.333 Adequate

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
3F P1 Bottom SW 2F to 3F 0.333 Adequate
3F P1 Bottom SW 2F to 3F 0.333 Adequate
3F P1 Bottom SW 2F to 3F 0.333 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
2F P1 Bottom SW Base to 1F 0.403 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
1F P1 Bottom SW Base to 1F 0.542 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
GF P1 Bottom SW Base to 1F 0.628 Adequate
39
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
14.0 SLAB ADEQUACY CHECK:
Calculation for two way slab
Slab Panel C-D/2-3 (Interior Panel, 1st Floor)

Slab Size, La (ft) = 20.33 f'c (psi) = 3500


Lb (ft) = 27.50 fy (psi) = 72500
Floor Finish (psf) = 25
Partition Wall (psf) = 0
Live Load (psf) = 100
Approximate Slab Thickness (in) = 6.38
Provided Slab Thickness (in) = 7.5
Effective Slab Thickness (in) = 6.375
Factored Dead Load, ωdl (psf) = 142.5
Factored Live Load, ωdl (psf) = 160
m= 0.74

Reinforcement Check (Case-2)


Short Direction Long Direction
Positive Positive
Negative Negative
dl ll dl ll
Moment Co-efficient 0.078 0.031 0.046 0.014 0.007 0.013
Mu (Ib-ft) 9752.02 4867.75 3202.72 2327.36
Area of Steel, As (in2) 0.30 0.14 0.09 0.07
Assume, a 0.60 0.29 0.19 0.14
Check, a 0.60 0.29 0.19 0.14
Minimum As (in2) 0.16 0.16 0.16 0.16

Required Reinforcement
0.30 0.16 0.16 0.16
(in)
Provided Reinforcement
0.48 0.43 0.44 0.29
(in)

Comments: Provided reinforcement is greater than required reinforcement.


40
Page

ROAD NO-30, HOUSE NO-424, 3RD FLOOR, NEW DOHS MOHAKHALI -1206
15.0 CONCLUSION & RECOMMENDATION:
We performed analysis and design and the following observation has been found-
 All members has been checked considering BNBC-2020 Standard.
 All column and beam members are adequate to resist applied gravity and lateral
load.
 Number of pile are sufficient to carry the total superimposed load.
 Floor slab are capable to carry applied load.
 Serviceability (drift, lateral displacement,) are within allowable limit.

Thanking You