Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1 2 3 4 5 6 7 8 9 10 11 12

NOTES
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE INDICATED.
2. PRESENT DESIGN IS GIVEN FOR VALVE CHAMBER
LOCATED OUTSIDE ASPHALTED ROAD.
3. THE CLEAR DISTANCE "H" BETWEEN THE TOP OF
4700 4700
A THE WALL AND THE NEAREST GROUND LEVEL A
400 3900 400 400 3900 400
MUST BE GREATER THAN 200mm.
4. THE LENGTH OF DOUBLE SPIGOT ROCKER PIPE
SHALL BE BETWEEN 1.5 TO 2.0 DN ACCORDING

(19)
400

400
TO SITE CONDITIONS.
5. THE WELDING OD PUDDLE FLANGE TO THE PIPE
SHALL BE DONE ONLY BY THE MANUFACTURER
8 T16 05-150 T1 IN FACTORY.
25 T16 03-150 B2 22 T16 03-150 T2 6. PRESSURE PIPES SHALL BE CLASS K9, FITTINGS
SHALL BE CLASS K14, THE NOMINAL PRESSURE
PN FOR VALVES AND FLANGES SHALL BE PN16.
7. THE EXACT LOCATION OF THE SURFACE BOX IS
TO BE VERIFIED & FIXED ON SITE.

Ø600mm

Ø600mm
CL CL 8. ALL INTERNAL SURFACES TO BE PAINTED ON A
WATERPROOF NON TOXIC BASED ON
B DN1 DN1 CEMENTITIOUS MATERIAL WHICH ALSO HAS THE B
PROPERTY OF SEALING VOIDS IN PROTECTING
CONCRETE FROM ANY CORROSIVE ACT ON.
ROCKER PIPE ROCKER PIPE 9. ALL GRP LADDER TO BE IN ACCORDANCE WITH
2900

2900
3700

3700
500 THK
SPECIFICATIONS.GRP LADDER WITH CAGE IF
RAFT SLAB DEPTH OF CHAMBER IS MORE THAN 2500mm.
32 T16 02-150 B1 26 T16 02-150 T1 (3) (20) (3)

(4) (4)

20 T16 01-1000
CHAIR BARS 4 T16 04-150 T2 4 T16 06-150 T2 4 T16 04-150 T2
A
A 8 T16 04-150 T1 (4) (4) 4 T16 22-150 T2
C SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1% C

4 T16 22-150 T2
WATER PROOFING (4) (4) WATER PROOFING

(3)
400

400
8 T16 22-150 T1
SUMP 500x500x300 SUMP 500x500x300
Mechanical GA drawing ref.no to be write:
DN107-P01A-QBS-PW-7003
B

B
DN2 DN2

BRANCH VALVE CHAMBER RAFT BOTTOM BRANCH VALVE CHAMBER RAFT TOP REFERENCE: KAHRAMA DRAWING:
D NDS-SD-226 D
REINFORCEMENT DETAILS REINFORCEMENT DETAILS NDS-SD-201
SCALE 1:25 SCALE 1:25
2. Mechanical GA drawing ref.no to be write:
DN107-P01A-QBS-PW-7004

00 19FEB24 ISSUED FOR APPROVAL ANKUSH JM DD

Rev. Date Revision Details Drawn Chkd. Appd.

E 1 T16 29-150 B2 1 T16 29-150 T2 E


5 T16 30-150 B2 1 T16 28-150 B2
4700
1 T16 28-150 B2 5 T16 30-150 B2
Remove chamber 5 T16 30-150 T2 1 T16 28-150 T2
4700
1 T16 28-150 T2 5 T16 30-150 T2

400 3900 400


indication Plate 400 3900 400
(12)

(12)

(12)

(12)
400

400
1 T16 33-150 B2

1 T16 33-150 T2
20 T16 13-1000
Consultant:
1 T16 09-150 B1

CHAIR BARS 21 T16 07-150 T1

ITALCONSULT

1 T16 09-150 T1
P.O. Box 2573
21 T16 07-150 B1 22 T16 07-150 B1 22 T16 07-150 T1 Doha - Qatar, Qatar Tower F
F TEL: 44353662/52

250 THK SLAB 250 THK SLAB Main Contractor :

1 T16 08-150 B1 1 T16 31-150 B1 1 T16 32-150 B1 1 T16 08-150 T1 1 T16 31-150 T1 1 T16 32-150 T1 QBS CONSTRUCTION WLL
PO Box 37082, Doha - Qatar
2900

2900
3700

3700

3700

3700
www.qbsconstruction.com
250 THK SLAB

250 THK SLAB


(2)

(6)

(2)

(6)
T: + 974 421 4672
1 T16 23-150 B1 1 T16 36-150 B2 1 T16 23-150 T1 1 T16 36-150 T2 F: + 974 421 4739
(3)

(3)
1 T16 24-150 B1 1 T16 24-150 T1 Project Name:

13 T16 10-150 B2 (4) (3) (3) (3) (5) (3) (4) 12 T16 10-150 B2 13 T16 10-150 T2 (4) (3) (3) (3) (5) (3) (4) 12 T16 10-150 T2 CONSTRUCTION OF REMAINING WORK OF
C2017/70, ROADS AND INFRASTRUCTURE
1 T16 34-150 B1 1 T16 35-150 B1 1 T16 34-150 T1 1 T16 35-150 T1
5 T16 25-150 B1 5 T16 11-150 B1 5 T16 25-150 B1 5 T16 25-150 T1 5 T16 11-150 T1 5 T16 25-150 T1 IN AL FROOSH /AL KHARITIYAT -
G G
5 T16 11 -50 B1 5 T16 11 -150 T1 PACKAGE 1 (DN107-P01) - C/2023/3
Project Code:
A PA 2022 C 003 G
(4)

(4)

(4)

(4)
Status:
400

400

SHOP DRAWING
Drawing Title:
5 T16 12-150 B2 1 T16 26-150 B2 1 T16 27-150 B2 2 T16 37-150 B2 5 T16 12-150 B2 5 T16 12-150 T2 1 T16 26-150 T2 1 T16 27-150 T2 2 T16 37-150 T2 5 T16 12-150 T2 BRANCH VALVE CHAMBER
REINFORCEMENT DETAILS
BRANCH VALVE CHAMBER COVER SLAB BRANCH VALVE CHAMBER COVER SLAB (600mm DIA. PIPE)
B

H
BOTTOM REINFORCEMENT DETAILS TOP REINFORCEMENT DETAILS Drawn: Checked: H
SCALE 1:25 SCALE 1:25 ANKUSH D.D.
Designed: Approved:

Date: Scale:
FEBRUARY 2024 N.T.S
Drawing Number: Revision:

DN107-P01A- QBS - BVC- 7004 00


1 2 3 4 5 6 7 8 9 10 11 12
V1
1 2 3 4 5 6 7 8 9 10 11 12

NOTES
1. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE INDICATED.
2. PRESENT DESIGN IS GIVEN FOR VALVE CHAMBER
110 T16 14-150 V OF LOCATED OUTSIDE ASPHALTED ROAD.
3 T16 15-150 H OF 16 T16 15-150 H OF 110 T16 38-150 V OF
WALL STARTER 3. THE CLEAR DISTANCE "H" BETWEEN THE TOP OF
4700 4700 THE WALL AND THE NEAREST GROUND LEVEL
A A
400 3900 400 400 3900 400 MUST BE GREATER THAN 200mm.
4. THE LENGTH OF DOUBLE SPIGOT ROCKER PIPE
SHALL BE BETWEEN 1.5 TO 2.0 DN ACCORDING
TO SITE CONDITIONS.

400

400
5. THE WELDING OD PUDDLE FLANGE TO THE PIPE
SHALL BE DONE ONLY BY THE MANUFACTURER
3 T16 16-150 H IF 98 T16 14-150 V IF 16 T16 16-150 H IF 98 T16 38-150 V IF IN FACTORY.
WALL STARTER 6. PRESSURE PIPES SHALL BE CLASS K9, FITTINGS
SHALL BE CLASS K14, THE NOMINAL PRESSURE
PN FOR VALVES AND FLANGES SHALL BE PN16.
7. THE EXACT LOCATION OF THE SURFACE BOX IS
TO BE VERIFIED & FIXED ON SITE.

Ø600mm

Ø600mm
CL CL 8. ALL INTERNAL SURFACES TO BE PAINTED ON A
WATERPROOF NON TOXIC BASED ON
B DN1 DN1 CEMENTITIOUS MATERIAL WHICH ALSO HAS THE B
PROPERTY OF SEALING VOIDS IN PROTECTING
CONCRETE FROM ANY CORROSIVE ACT ON.
ROCKER PIPE ROCKER PIPE 9. ALL GRP LADDER TO BE IN ACCORDANCE WITH
2900

2900
3700

3700
LAP

LAP
800

800
LAP

LAP
800

800
3 T16 17-150 H IF 3 T16 17-150 H IF 16 T16 17-150 H IF 16 T16 17-150 H IF SPECIFICATIONS.GRP LADDER WITH CAGE IF
DEPTH OF CHAMBER IS MORE THAN 2500mm.

A A
C 3 T16 16-150 H IF 16 T16 16-150 H IF C
400

400
3 T16 15-150 H OF 16 T16 15-150 H OF
SUMP 500x500x300 SUMP 500x500x300

Mechanical GA drawing ref.no to be write:


B

B
DN107-P01A-QBS-PW-7003
DN2 DN2

BRANCH VALVE CHAMBER WALL STARTER 750


BRANCH VALVE CHAMBER WALL REFERENCE: KAHRAMA DRAWING:
D REINFORCEMENT DETAILS REINFORCEMENT DETAILS NDS-SD-226 D

750
2x4 T16 18 DIAG. BARS NDS-SD-201
SCALE 1:25 SCALE 1:25
4x2 T16 21 DIAG. BARS

1. Show Wall opening for 400mm branch line. 2x4 T25 20 OPNG ADD'L Ø600

2. Provide section for lifting hook details


3. Show typical dimension of rebars for Slab and wall 2x4 T25 19 OPNG ADD'L
00 19FEB24 ANKUSH JM DD
opening with rebar length Rev. Date
ISSUED FOR APPROVAL

Revision Details Drawn Chkd. Appd.

E E
SLAB OPENING ADDITIONAL (2 NOS.)
WALL OPENING ADDITIONAL (3 NOS.)
As per section A-A to be shown cover opening
As per section B-B to be shown cover opening

COVER
50
T16-150 T2&B2 T12-150 T2&B2 T16-150 T1&B1
CL : 26.600 CL : 26.600 Consultant:
250

250

250

250
350

350

350

350
FGL: 26.250 FGL: 26.250 FGL: 26.250 FGL: 26.250
ITALCONSULT
T16-150 T1&B1 T16-150 T1&B1
T16-150 T2&B2 P.O. Box 2573
COVER

COVER

COVER
Doha - Qatar, Qatar Tower F
F
50

50

50
TEL: 44353662/52

Main Contractor :

QBS CONSTRUCTION WLL


75 75 75 75
PO Box 37082, Doha - Qatar
COVER COVER COVER COVER
www.qbsconstruction.com
T: + 974 421 4672
T16-150 V EF T16-150 V EF T16-150 V EF T16-150 V EF F: + 974 421 4739

T16-150 H EF T16-150 H EF T16-150 H EF T16-150 H EF Project Name:


CONSTRUCTION OF REMAINING WORK OF
75 75 75 75
COVER COVER COVER COVER C2017/70, ROADS AND INFRASTRUCTURE
IN AL FROOSH /AL KHARITIYAT -
G G
PACKAGE 1 (DN107-P01) - C/2023/3
LAP

LAP

LAP
640

640

640
T16-150 V EF T16-150 V EF T16-150 V EF T16-150 V EF Project Code:
COVER

COVER
WALL STARTER WALL STARTER WALL STARTER WALL STARTER PA 2022 C 003 G
75

75
Status:
SHOP DRAWING
150

150

150
Drawing Title:
WATER PROOFING
BRANCH VALVE CHAMBER
500

500

500
TOP OF BLINDING TOP OF BLINDING REINFORCEMENT DETAILS
T16-150 T&B T16-150 T&B
(600mm DIA. PIPE)
COVER

COVER
SUMP 500x500x300
75

75
400 500 2900 500 400 400 500 2400 400
H 4700 3700 Drawn: Checked: H
ANKUSH D.D.
SUMP 500x500x300 Designed: Approved:
SECTION A-A SECTION B-B
Date: Scale:
SCALE 1:25 SCALE 1:25 FEBRUARY 2024 N.T.S
Drawing Number: Revision:

DN107-P01A- QBS - BVC- 7005 00


1 2 3 4 5 6 7 8 9 10 11 12
V1