Ex Symbols, EPLs and IEC Standards (Gas Group)

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Zone System Electrical Equipment Protection Techniques,

Ex Symbols, EPLs and IEC Standards (Gas Group)

Flameproof*
da IEC 60079-1
Intrinsic Safety
ZONE 0 Encapsulation
ia
ma
Ga
IEC 60079-11
IEC 60079-18
Optical Radiation
op is | op sh IEC 60079-28
*Note: Applies to catalytic
sensors only

Flameproof db IEC 60079-1


Purged/pressurized pxb | pyb IEC 60079-2
Powder Filling q IEC 60079-5
ZONE 1 Liquid Immersion ob
Gb
IEC 60079-6
Increased Safety eb IEC 60079-7
Intrinsic Safety ib IEC 60079-11
Encapsulation mb IEC 60079-18
Optical Radiation op is | op sh | op pr IEC 60079-28

Flameproof dc IEC 60079-1


Purged/pressurized pzc IEC 60079-2
Liquid Immersion oc IEC 60079-6
Increased Safety ec IEC 60079-7
Intrinsic Safety ic IEC 60079-11
ZONE 2 Enclosed Break nC Gc IEC 60079-15
Hermetically Sealed nC IEC 60079-15
Non-sparking nA IEC 60079-15
Restricted Breathing nR IEC 60079-15
Encapsulation mc IEC 60079-18
Optical Radiation op is | op sh | op pr IEC 60079-28

Hazloc Directory is the world's most trusted source of information about hazardous
location products, manufacturers, and service providers.
www.hazlocdirectory.com
Toll Free North America: 1 (800) 488-7177 International: +1 (416) 900-0872
Email: contact@hazlocdirectory.com