General .
The consistency transmitter is installed in the pipe line, either
through a measuring vessel or a weld-in stud. The measuring
vessel is used for small pipe dimensions and the weld-in stud
for larger dimensions.
The length of the measuring chamber, i.e. the part of the vessel
in which the sensing element of the transmitter rotates,
depends on type of selected consistency transmitter and mea-
suring conditions.
Pipe pressure Low/medium press. - max 10/16 bar (150/240 psi) High pressure - max 25bar (360 psi)
Intended for transmitter MEK-xx00, -xx08, -xx10, -xx11, -xx20 MEK-xx12, -xx14, -xx15.
och -xx50.
Mounting in Measuring vessel* Weld-in stud* Measuring vessel* Weld-in stud*
(PN10) (PN16)
Pipe size - DN Ø D 100 - 250 mm/ Ø D > 300 mm/12" Ø D 150 - 250 mm/ Ø D 300-450 mm/
4 - 10" 6 - 10" 12-18" > 500 mm/20"
- Mounting Weld connection acc. For welding to main Weld connection acc. For welding to main
to ID, ISO or other pipe pipe. to ID, ISO or other pipe pipe.
standard. Please state standard. Please state
pipe dimension with pipe dimension with
your order. your order.
Flanged connection For welding to main Flanged connection For welding to main
- on request. Acc. to pipe. - on request. Acc. to pipe.
DIN 2642 or ANSI 150 DIN 2655 or ANSI 300
lbs. lbs.
Max operating pressure/ NP 10 NP 10 25 bar/226° C 25 bar/226° C
medium temperature (150 psi/68°F) (150 psi/68°F). 360 psi/440°F 360 psi/440°F
(Dimensional values) Note: see also shut-off Note: see also shut-off
valve. valve.
Material SS 2343/ SS 2343/ SS 2343. SS 2343/
SS 2562/ SS 2562/ SS 2562/
Hastelloy C-276. Hastelloy C-276. Hastelloy C-276.
Inspection cover Standard Recommended -- --
Blind flange On request. On request. On request. On request.
* Calculated and approved according to Swedish standard: AFS 1990:15/RN-78/TKN-87.
Calculated according to American National Standard ASME section VIII - Div. 1.
Transmitter type Measuring chamber length M at Normal or medium consistency/high pressure design
MEK-xx00. cons. < ≈ 5 % = 150 mm/6" at Measuring vessel and weld-in stud for:
cons. > ≈ 5 % = 70 mm/2.8" Transmitter type Measuring chamber length, weld-in
MEK-xx12, -xx14, stud M = 60 mm/2.4". For the
• The measuring chamber length is always based on the mea- and -xx15. measuring vessel M = 65-90 mm/2.5-
suring conditions. Therefore, please contact BTG for proper 3.5" depending on size. The
selection. measuring vessel is equipped with a
deflector. The weld-in stud is
Transmitter type M = 70 mm/2.8" delivered with a deflector.
MEK-xx08.
Transmitter type M = 100 mm/4"
MEK-xx20.
Shut-off valve
Note! The shut-off valve should only be used at low operating pres-
sure/low temperature/innoxious suspensions as complete tightness
cannot be guaranteed over the entire slide gate during removal of
the transmitter. Incautious handling is a potential risk of injury.
A B C D
mm/inch mm/inch mm/inch mm/inch
Fig 5 Measuring vessel for MEK-xx12, (-xx14), -xx15**.
Size 150-250 mm/6-10", 25 bar/226°C (360 psi/ 165/6.5 285/11.2 410/16.1 150/6"
440°Φ) 165/6.5 285/11.2 410/16.1 200/8"
200/8 310/12.2 460/18.1 250/10"
See installation instruction in user manual for transmitter for
detailed instructions regarding installation and start-up. Alt. A.Weld connection acc. to ID or ISO standard.
BTG reserves the right to make technical improvements without previous notice.
BTG Instruments AB
Box 602, SE-661 29 Säffle Tel: +46 533 426 00 btg@btg.com
Sweden Fax: +46 533 125 00 www.btg.com