1− ALL DIMENSIONS SHOWN ON DRAWINGS ARE IN

CENTIMETERS METRIC UNITS.

2− DRAWINGS ARE NOT TO BE SCALED. ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

3− ALL MATERIALS USED IN CONSTRUCTION SHALL BE


OF THE BEST QUALITY TO REQUIRED BRITISH OR
EQUIVALENT STANDARDS AND AS APPROVED BY
CONSULTANT PRIOR TO COMMENCEMENT OF WORK.

4− THE CONTRACTOR SHALL SUPPLY SHOP DRAWINGS


SHOWING DETAILS OF SIZES AND INSTALLATION FOR
DOOR,WINDOWS,KITCHEN CUPBOARDS,HAND RAILING,
ENTRANCE GATE ETC. FOR CONSULTANTS APPROVALS
(WITHIN 6 WEEKS FROM DATE OF COMMENCEMENT)

5− THESE DRAWINGS ARE COPYRIGHT OF (D.H.)


THESE DRAWINGS ARE NOT TO BE COPIED OR
REPRODUCED WITHOUT CONSULTANT’S PERMISSION.
ALL THE DRAWINGS SHALL BE RETURNED BACK TO
THE D.H. ENGINEER ON COMPLETION OF THE JOB.

MH-04
MH-5 MH-03 MH-02 MH MANHOLE
60X60
60X60
CL=+30
+30 60X60 60X60
CL=+30 CL=+30
CL=+30
IL=-41
IL=-36 INTER.L. IL=-29 IL=-22
GT
GULLY TRAP

150 mm Ø uPVC Line 150mm Ø uPVC Line slope 1:90 MH


150 mm Ø uPVC Line
MH
MH MH
FLOOR TRAP
FT
slope 1:90 slope 1:90
GT GT

150mm Ø uPVC Line slope 1:90

150mm Ø uPVC Line slope 1:90


RWO RAIN WATER OUTLET

BD TERRACE DRAIN

WP WASTE PIPE

SP SOIL PIPE

MH-06 VP
GT
VENT PIPE
60X60 MH MH-01
CL=+30 60X60
RWP
IL=-47
G+1 VILLA CL=+30 RAIN WATER PIPE
MH
150mm Ø uPVC Line slope 1:90

GT

IL=-15

F/A FROM ABOVE DH STAMP:


+815
T/A TO ABOVE
S.S.L.
T/B TO BELOW

S.V.P SOIL VENT PIPE

W.V.P WASTE VENT PIPE

SCHEDULE OF PIPES
WASH BASIN TO FLOOR TRAP - 40mmØ

BIDET TO FLOOR TRAP - 50mmØ

BATH TUB TO FLOOR TRAP - 50mmØ


1 ‫ﻧﻣﻭﺫﺝ ﻣﻛﺭﻣﺔ‬
SHOWER TRAY TO FLOOR TRAP - 50mmØ
‫ ﻏﺭﻑ‬5 ‫ﺳﻛﻧﻳﺔ‬ ‫ﻭﺣﺩﺓ‬
EL. +30 50mmØ
KITCHEN SINK TO FLOOR TRAP -
INTERLOCK L.
BALCONY DRAIN PIPE - 50mmØ
MH-08
90X90 MH-07 A/C DRAIN PIPE - 25mmØ
CL=+30 90X90
IL=-65 CL=+30
IL=-61 FLOOR TRAP TO GULLY TRAP - 80mmØ
150 mm Ø uPVC Line
MH slope 1:90 MH
W.C TO MANHOLE - 100mmØ

SOIL PIPE - 100mmØ


WASTE PIPE - 100mmØ

GULLY TRAP TO MANHOLE - 75mmØ


75mmØ VP

JOB TITLE:
150mm Ø uPVC Line slope 1:90

SCHEDULE OF MANHOLE PROPOSED


MH-No
MH-SIZE
(cm) COVER LEVEL INVERT LEVEL MH-DEPTH
MH-COVER
TYPE
REMARKS
VILLA G+1
MH-01 60X60 +0.30 -0.15 0.45 HD COVER VENT

MH-02 HD COVER
60X60 +0.30 -0.22 0.52 DRAWING TITLE:
MH-09 MH-03 60X60 HD COVER
+0.30 -0.29 0.59
90X90
CL=+30 MH-04 60X60 +0.30 -0.36 0.66 HD COVER
IL=-90
MH-05 60X60 +0.30 -0.41 0.71 HD COVER
( SETTING LAYOUT )
MH-06 60X60 +0.30 -0.47 0.77 HD COVER VENT

MH-07 90X90 +0.30 -0.61 0.91 HD COVER

75mmØ VP MH-08 90X90 +0.30 -0.65 0.95 HD COVER VENT HEAD OF SEC:
ENG. ABDULLA MAHMOUD
CONNECT WITH SMD LINE MH-09 90X90 +0.30 -0.90 0.120 HD COVER VENT
ARCH.DESIGNED BY: DRAWN BY:
ENG. RAZAN AHMAD ENG.MOHAMMAD FATHI
STRUCT. DESIGN BY: DRAWN BY:
A/C DRAINE PIPE SHOULD BE PLACED ENG.ABDULLA ALMARZOOQI ENG.MOHAMMAD FATHI

AS PER A/C LOCATION. SERVICES DESIGN BY: DRAWN BY:


ENG.MOHAMMED MUSTAFA ENG.MOHAMMED SHAFEEQ
CHECKED BY:
ENG. RAZAN AHMAD
ENG.ABDULLA ALMARZOOQI
ENG. MOHAMMED MUSTAFA
( SETTING LAYOUT )
SCALE : DATE : DRG NO :
1: 100 OCT. 2022 D-01
1− ALL DIMENSIONS SHOWN ON DRAWINGS ARE IN
CENTIMETERS METRIC UNITS.

2− DRAWINGS ARE NOT TO BE SCALED. ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

3− ALL MATERIALS USED IN CONSTRUCTION SHALL BE


OF THE BEST QUALITY TO REQUIRED BRITISH OR
MH-04
MH-5 MH-03 MH-02 EQUIVALENT STANDARDS AND AS APPROVED BY
60X60 CONSULTANT PRIOR TO COMMENCEMENT OF WORK.
60X60 CL=+30 60X60 60X60
CL=+30 CL=+30 CL=+30 4− THE CONTRACTOR SHALL SUPPLY SHOP DRAWINGS
IL=-36 IL=-29
IL=-41 IL=-22 SHOWING DETAILS OF SIZES AND INSTALLATION FOR
150mm Ø uPVC Line slope 1:90 150 mm Ø uPVC Line
DOOR,WINDOWS,KITCHEN CUPBOARDS,HAND RAILING,
MH
150 mm Ø uPVC Line MH
EL. +30
+60 MH MH ENTRANCE GATE ETC. FOR CONSULTANTS APPROVALS
INTERLOCK L.
slope 1:90 F.L. slope 1:90 (WITHIN 6 WEEKS FROM DATE OF COMMENCEMENT)
EL. +30
INTERLOCK L. GT
5− THESE DRAWINGS ARE COPYRIGHT OF (D.H.)
GT

150mm Ø uPVC Line slope 1:90

150mm Ø uPVC Line slope 1:90


THESE DRAWINGS ARE NOT TO BE COPIED OR
+75 REPRODUCED WITHOUT CONSULTANT’S PERMISSION.
ALL THE DRAWINGS SHALL BE RETURNED BACK TO
F.L. 100mmØ S.P F/A THE D.H. ENGINEER ON COMPLETION OF THE JOB.
100mmØ W.P F/A
FT

+105
G.F.L.
FT
+75
F.L.
+90
F.L.

+105
G.F.L.
FT

MH-06 GT

60X60 MH MH-01
CL=+30 60X60
IL=-47 MH CL=+30

150mm Ø uPVC Line slope 1:90


GT
+105
G.F.L. IL=-15
FT
FT

75mmØ VP 100mmØ R.W.P F/A


100mmØ W.P F/A 100mmØ S.P F/A
100mmØ S.P F/A
100mmØ R.W.P F/A 100mmØ W.P F/A
EL. +30
TO BELOW FREE 75mmØ VP INTERLOCK L.

DISCHARGE
SCHEDULE OF MANHOLE
MH-SIZE MH-COVER
MH-No COVER LEVEL INVERT LEVEL MH-DEPTH REMARKS
(cm) TYPE

MH-01 60X60 +0.30 -0.15 0.45 HD COVER VENT


+105
DH STAMP:
G.F.L. MH-02 60X60 +0.30 -0.22 0.52 HD COVER

MH-03 60X60 +0.30 -0.29 0.59 HD COVER

MH-04 60X60 +0.30 -0.36 0.66 HD COVER

MH-05 60X60 +0.30 -0.41 0.71 HD COVER


EL. +30
INTERLOCK L. MH-06 60X60 +0.30 -0.47 0.77 HD COVER VENT

MH-07 90X90 +0.30 -0.61 0.91 HD COVER

MH-08 90X90 +0.30 -0.65 0.95 HD COVER VENT

MH-09 90X90 +0.30 -0.90 0.120 HD COVER VENT


MH-08
90X90 MH-07
CL=+30 90X90 1 ‫ﻧﻣﻭﺫﺝ ﻣﻛﺭﻣﺔ‬
IL=-65 CL=+30
150 mm Ø uPVC Line IL=-61 ‫ ﻏﺭﻑ‬5 ‫ﺳﻛﻧﻳﺔ‬ ‫ﻭﺣﺩﺓ‬
MH slope 1:90 MH MH MANHOLE
A/C DRAINE PIPE SHOULD BE PLACED
GT
GULLY TRAP
AS PER A/C LOCATION.
FT
FLOOR TRAP SCHEDULE OF PIPES
RWO RAIN WATER OUTLET WASH BASIN TO FLOOR TRAP - 40mmØ
75mmØ VP

BD BALCONY /TERRACE BIDET TO FLOOR TRAP - 50mmØ


150mm Ø uPVC Line slope 1:90

DRAIN
BATH TUB TO FLOOR TRAP - 50mmØ
WP WASTE PIPE
SHOWER TRAY TO FLOOR TRAP - 50mmØ
JOB TITLE:
SP SOIL PIPE
KITCHEN SINK TO FLOOR TRAP - 50mmØ
PROPOSED
VP

MH-09
VENT PIPE BALCONY DRAIN PIPE - 50mmØ VILLA G+1
90X90 RWP RAIN WATER PIPE A/C DRAIN PIPE - 25mmØ
CL=+30
DRAWING TITLE:
IL=-90
FLOOR TRAP TO GULLY TRAP - 80mmØ
F/A FROM ABOVE

T/A TO ABOVE W.C TO MANHOLE - 100mmØ


( GROUND FLOOR PLAN )
75mmØ VP T/B TO BELOW
SOIL PIPE - 100mmØ
CONNECT WITH SMD LINE S.V.P SOIL VENT PIPE HEAD OF SEC:
WASTE PIPE - 100mmØ
ENG. ABDULLA MAHMOUD
W.V.P WASTE VENT PIPE GULLY TRAP TO MANHOLE - 75mmØ ARCH.DESIGNED BY: DRAWN BY:
ENG. RAZAN AHMAD ENG.MOHAMMAD FATHI
STRUCT. DESIGN BY: DRAWN BY:
ENG.ABDULLA ALMARZOOQI ENG.MOHAMMAD FATHI
SERVICES DESIGN BY: DRAWN BY:
ENG.MOHAMMED MUSTAFA ENG.MOHAMMED SHAFEEQ
CHECKED BY:
ENG. RAZAN AHMAD
ENG.ABDULLA ALMARZOOQI
( GROUND FLOOR PLAN )
ENG. MOHAMMED MUSTAFA

SCALE : DATE : DRG NO :


1: 100 OCT. 2022 D-02
1− ALL DIMENSIONS SHOWN ON DRAWINGS ARE IN
CENTIMETERS METRIC UNITS.

2− DRAWINGS ARE NOT TO BE SCALED. ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

100mmØ S.P F/A 3− ALL MATERIALS USED IN CONSTRUCTION SHALL BE


OF THE BEST QUALITY TO REQUIRED BRITISH OR
100mmØ W.P F/A 100mmØ W.P F/A EQUIVALENT STANDARDS AND AS APPROVED BY
CONSULTANT PRIOR TO COMMENCEMENT OF WORK.
100mmØ S.P F/A
4− THE CONTRACTOR SHALL SUPPLY SHOP DRAWINGS
SHOWING DETAILS OF SIZES AND INSTALLATION FOR
DOOR,WINDOWS,KITCHEN CUPBOARDS,HAND RAILING,
+300
P) ENTRANCE GATE ETC. FOR CONSULTANTS APPROVALS
F.L.
(TY

SLOPE 1:90 (TYP)


(WITHIN 6 WEEKS FROM DATE OF COMMENCEMENT)
FT

:9 0 SL
1 O
FT

PE PE 5− THESE DRAWINGS ARE COPYRIGHT OF (D.H.)


O ) 1

SLOPE 1:90 (TYP)


SL TYP :90 THESE DRAWINGS ARE NOT TO BE COPIED OR
0( (T REPRODUCED WITHOUT CONSULTANT’S PERMISSION.
1:9 YP
100mmØ R.W.P F/A ALL THE DRAWINGS SHALL BE RETURNED BACK TO
PE ) THE D.H. ENGINEER ON COMPLETION OF THE JOB.
SLO

RIDGE LINE
TO BELOW FREE
DISCHARGE
100mmØ S.P F/A
FT

SLOPE 1:9
0 (TYP)
100mmØ W.P F/A
100mmØ R.W.P F/A +815 75mmØ VP
TO BELOW FREE VALLEY S.S.L.
+465 DISCHARGE VALLEY
F.F.L.
100mmØ S.P F/A RWO 75mmØ VP
0 (TYP)
FT

75mmØ VP RAIN WATER OUTLET


100mmØ W.P F/A 100mmØ W.P F/A SLOPE 1:9 RWO
100mmØ W.P F/A 100mmØ S.P F/A SLO RAIN WATER OUTLET
75mmØ VP P E1
100mmØ S.P F/A 100mmØ R.W.P F/A :9 0
(TY
100mmØ R.W.P F/A TO BELOW FREE P)

SLOPE 1:90 (TYP)


TO BELOW FREE DISCHARGE
SL
DISCHARGE OP

SLOPE 1:90 (TYP)


E1
: 90

)
YP
(T

(T
YP

90
)

1:
E
OP
SL
DH STAMP:

( FIRST FLOOR PLAN ) ( ROOF PLAN )

1 ‫ﻧﻣﻭﺫﺝ ﻣﻛﺭﻣﺔ‬
‫ ﻏﺭﻑ‬5 ‫ﺳﻛﻧﻳﺔ‬ ‫ﻭﺣﺩﺓ‬
MH MANHOLE
A/C DRAINE PIPE SHOULD BE PLACED
GT
GULLY TRAP
AS PER A/C LOCATION.
FT
FLOOR TRAP SCHEDULE OF PIPES
RWO RAIN WATER OUTLET WASH BASIN TO FLOOR TRAP - 40mmØ

BD BALCONY /TERRACE BIDET TO FLOOR TRAP - 50mmØ


DRAIN
BATH TUB TO FLOOR TRAP - 50mmØ
WP WASTE PIPE
SHOWER TRAY TO FLOOR TRAP - 50mmØ JOB TITLE:
SP SOIL PIPE
KITCHEN SINK TO FLOOR TRAP - 50mmØ PROPOSED
VP
VENT PIPE BALCONY DRAIN PIPE - 50mmØ
VILLA G+1
RWP RAIN WATER PIPE A/C DRAIN PIPE - 25mmØ DRAWING TITLE:

FLOOR TRAP TO GULLY TRAP - 80mmØ


F/A FROM ABOVE
( FIRST FLOOR PLAN )
T/A TO ABOVE W.C TO MANHOLE - 100mmØ ( ROOF PLAN )
T/B TO BELOW
SOIL PIPE - 100mmØ
HEAD OF SEC:
S.V.P SOIL VENT PIPE ENG. ABDULLA MAHMOUD
WASTE PIPE - 100mmØ
ARCH.DESIGNED BY: DRAWN BY:
W.V.P WASTE VENT PIPE GULLY TRAP TO MANHOLE - 75mmØ ENG. RAZAN AHMAD ENG.MOHAMMAD FATHI
STRUCT. DESIGN BY: DRAWN BY:
ENG.ABDULLA ALMARZOOQI ENG.MOHAMMAD FATHI
SERVICES DESIGN BY: DRAWN BY:
ENG.MOHAMMED MUSTAFA ENG.MOHAMMED SHAFEEQ
CHECKED BY:
ENG. RAZAN AHMAD
ENG.ABDULLA ALMARZOOQI
ENG. MOHAMMED MUSTAFA

SCALE : DATE : DRG NO :


1: 100 OCT. 2022 D-03
1− ALL DIMENSIONS SHOWN ON DRAWINGS ARE IN
CENTIMETERS METRIC UNITS.

2− DRAWINGS ARE NOT TO BE SCALED. ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

3− ALL MATERIALS USED IN CONSTRUCTION SHALL BE


OF THE BEST QUALITY TO REQUIRED BRITISH OR
EQUIVALENT STANDARDS AND AS APPROVED BY
CONSULTANT PRIOR TO COMMENCEMENT OF WORK.

4− THE CONTRACTOR SHALL SUPPLY SHOP DRAWINGS


SHOWING DETAILS OF SIZES AND INSTALLATION FOR
DOOR,WINDOWS,KITCHEN CUPBOARDS,HAND RAILING,
ENTRANCE GATE ETC. FOR CONSULTANTS APPROVALS
(WITHIN 6 WEEKS FROM DATE OF COMMENCEMENT)

5− THESE DRAWINGS ARE COPYRIGHT OF (D.H.)


THESE DRAWINGS ARE NOT TO BE COPIED OR
REPRODUCED WITHOUT CONSULTANT’S PERMISSION.
ALL THE DRAWINGS SHALL BE RETURNED BACK TO
THE D.H. ENGINEER ON COMPLETION OF THE JOB.

1 TYPICAL DRY MANHOLE DETAIL 2 TYPICAL MANHOLE - PLAN 3 SECTION A-A 4 SECTION B-B 5 6 PLANTER DRAIN DETAIL

TYPICAL CLEANOUT
8 IN THE SLAB
TYP. TWO PIECE FLOOR TRAP ASSY. SCHEDULE OF
10 MOUNTED ON FLOATING FLOORS 11 DRAIN PIPE SLOPE
9 CLASS 'B' BEDDING
DH STAMP:

1 ‫ﻧﻣﻭﺫﺝ ﻣﻛﺭﻣﺔ‬
‫ ﻏﺭﻑ‬5 ‫ﺳﻛﻧﻳﺔ‬ ‫ﻭﺣﺩﺓ‬
FLEXIBLE JOINTS IN DRAINAGE PIPEWORK SCHEDULE OF
7 GREASE INTERCEPTOR - TYPE 'C' DETAIL
12 CLASS 'O' BEDDING 13 CLASS 'O' BEDDING 14 BEDDING SCHEDULE 15 DRAIN PIPE SLOPE

JOB TITLE:

PROPOSED
C SECTION - CC VILLA G+1
DRAWING TITLE:

GENERAL DRAINAGE FITTING


DETAIL

HEAD OF SEC:
ENG. ABDULLA MAHMOUD
ARCH.DESIGNED BY: DRAWN BY:
ENG. RAZAN AHMAD ENG.MOHAMMAD FATHI
STRUCT. DESIGN BY: DRAWN BY:
TYP. CARPARK ENG.ABDULLA ALMARZOOQI ENG.MOHAMMAD FATHI
16 BASE OF STACK DETAIL 17 GULLY (CG) 18 FABRICATED UPVC DRAIN BODY DETAIL OF SEDIMENT SERVICES DESIGN BY: DRAWN BY:
TYPICAL ROOF RAIN WATER ENG.MOHAMMED MUSTAFA ENG.MOHAMMED SHAFEEQ
19 INTERCEPTOR / SAND TRAP OUTLET DETAILS
20 CHECKED BY:
ENG. RAZAN AHMAD
ENG.ABDULLA ALMARZOOQI
ENG. MOHAMMED MUSTAFA

SCALE : DATE : DRG NO :


1: 100 OCT. 2022 D-04
1− ALL DIMENSIONS SHOWN ON DRAWINGS ARE IN
CENTIMETERS METRIC UNITS.

2− DRAWINGS ARE NOT TO BE SCALED. ONLY WRITTEN


DIMENSIONS SHALL BE FOLLOWED.

3− ALL MATERIALS USED IN CONSTRUCTION SHALL BE


OF THE BEST QUALITY TO REQUIRED BRITISH OR
EQUIVALENT STANDARDS AND AS APPROVED BY
CONSULTANT PRIOR TO COMMENCEMENT OF WORK.

4− THE CONTRACTOR SHALL SUPPLY SHOP DRAWINGS


SHOWING DETAILS OF SIZES AND INSTALLATION FOR
DOOR,WINDOWS,KITCHEN CUPBOARDS,HAND RAILING,
ENTRANCE GATE ETC. FOR CONSULTANTS APPROVALS
(WITHIN 6 WEEKS FROM DATE OF COMMENCEMENT)

5− THESE DRAWINGS ARE COPYRIGHT OF (D.H.)


THESE DRAWINGS ARE NOT TO BE COPIED OR
REPRODUCED WITHOUT CONSULTANT’S PERMISSION.
ALL THE DRAWINGS SHALL BE RETURNED BACK TO
THE D.H. ENGINEER ON COMPLETION OF THE JOB.

DH STAMP:

VARIES
1 ‫ﻧﻣﻭﺫﺝ ﻣﻛﺭﻣﺔ‬
‫ ﻏﺭﻑ‬5 ‫ﺳﻛﻧﻳﺔ‬ ‫ﻭﺣﺩﺓ‬

JOB TITLE:

PROPOSED
VILLA G+1
DRAWING TITLE:

GENERAL SEPTIC TANK


SOAKAWAY DETAIL

1.0053 HEAD OF SEC:


ENG. ABDULLA MAHMOUD
ARCH.DESIGNED BY: DRAWN BY:
ENG. RAZAN AHMAD ENG.MOHAMMAD FATHI
STRUCT. DESIGN BY: DRAWN BY:
ENG.ABDULLA ALMARZOOQI ENG.MOHAMMAD FATHI
SERVICES DESIGN BY: DRAWN BY:
ENG.MOHAMMED MUSTAFA ENG.MOHAMMED SHAFEEQ
CHECKED BY:
ENG. RAZAN AHMAD
ENG.ABDULLA ALMARZOOQI
ENG. MOHAMMED MUSTAFA

SCALE : DATE : DRG NO :


1: 100 OCT. 2022 D-05

You might also like