“53” Maintenance Instructions for Alarm Problems

1. Error Code

2. Check the steps

2.1

TX7 D40/D47

Check D47/D40/TX7:
Components Normal range (Value) Remark
D40 VF=0.46~0.49V REF Multi meter diode position
D PAJ/RS1J 1A 600V SMD
D47 VF=0.46~0.49V REF Multi meter diode position
D PAJ/RS1J 1A 600V SMD
TX7 401-070006-00G

2.2 Check Inverter driver circuit


D1 ZD8

ZD1 D19

ZD2 ZD7

ZD19
ZD4
D20

ZD3 D2

Components Normal range Remark


(Value)
ZD2,ZD4,ZD7,ZD19 VF=0.7V REF Multi meter diode position
ZD NXP/BZT52-C5V6 0.41W 5.6V
SOD123F SMD
ZD1,ZD3,ZD8 VF=0.7V REF Multi meter diode position
ZD PANJIT/MMSZ5248B 0.5W
18V SMD
D4,D7,D8,D44,D45 VF=0.25V REF Multi meter diode position
D PANJIT/BAT54 0.2A 30V SMD
U1,U2,U3,U4,U12 V2-3=0.6V REF
IC PHO FAIRCHILD/FOD3150ASD
8PIN/SO-8 SMD V6-8=0.25V REF
V5-6=0.45V REF
V5-8=0.46~0.5V REF