Odom Echo Trac

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ODOM

ECHOTRAC™
MKIII MODEL

GENERAL DESCRIPTION
Like to keep your options open? Then Odom’s Echotrac™
MKIII is the echo sounder for you! It’s the only sounder on
the market offering you the choice of either a high-resolution
thermal paper recorder or a full-sized high bright color LCD
chart in interchangeable module format.

When it comes from Odom, you know it’s durable, easy


to use and backed by the best customer service in the
industry. Both high and low channels feature frequency agility,
enabling the operator to precisely match the transceiver
to almost any existing transducer. This matching ability
minimizes nearsurface noise caused by transducer ringing
while increasing echo return strength.

The MKIII is capable of both shallow and deep-water


operations and it features unsurpassed interfacing exibility
with four serial ports and high speed Ethernet capability
for maximum efciency. With all of these features in such
a compact and portable package, it’s easy to see why the
Echotrac™ MKIII is such a respected echo sounder.

Making OCEANSCAN LIMITED


technology DENMORE ROAD, BRIDGE OF DON, ABERDEEN,
SCOTLAND, U.K., AB23 8JW
work for you! TEL; +44(0)1224 707000, FAX: +44(0)1224 707001
Email: rental@oceanscan.co.uk, Website: www.oceanscan.co.uk
Accredited to BS EN ISO 9001:2000
ODOM
ECHOTRAC™
MKIII MODEL
TECHNICAL SPECIFICATIONS
Frequency Interfaces
• High band: 100 kHz – 1 MHz • 4 X RS232 or 3 X RS232 and 1 X RS422
• Low band: 3.5 kHz – 50 kHz • Inputs from external computer, motion sensor,
sound velocity
Output Power • Outputs to external computer, remote display
• High: 100kHz–1 kW RMS max 200kHz–900 W • Outputs with LCD chart – video out
RMS max, 750kHz – 300W RMS max • Ethernet interface
• Low: 3.5kHz–2kW RMS max, 50kHz–2kW RMS • Heave – TSS1 or sounder sentence
max
Blanking
Input Power • 0 to full scale
• 110 or 220 V AC/24 V DC 50 watts
Installation
Resolution • Desktop, optional rack mount or bulkhead
• 0.01m mount

Accuracy Help
• 0.01m +/- 0.1% of depth @ 200 kHz • The function of each parameter and it’s
• 0.10m +/- 0.1% of depth @ 33 kHz minimum and maximum values can be printed
• 0.18m +/- 0.1% of depth @12 kHz on the paper chart. The record of settings in
(corrected for sound velocity) tabular format is available on demand, and
a continuous printoutof parameters is available
Depth Range on thermal paper models.
• 0.2 – 200 m @ 200 kHz Log les are automatically created by Echotrac
• 0.5 – 1500 m @ 33 kHz Control when that software is used to control
• 1.0 – 6000 m @ 12 kHz the sounder.

Phasing Environmental Operating Temperature


• Automatic scale change, 10%, 20%, 30% • 0’ – 50’ C, 5 – 90% relative humidity, non-
overlap or Manual condensing

Printer Dimensions
• High resolution 8 dot/mm (203 dpi), 16 gray • 450 mm H x 450 mm W x 300 mm D
shades
• 216mm wide thermal paper or lm Weight
• External ON/OFF switch • 15.9 kg
• Paper advance control
Options
Paper Speed • Remote Display
• 1cm/min. to 22 cm/mm • Side Scan Transducer 200 kHz or 340 kHz
Auto = one dot row advance for each Ping • Built-in DGPS

Sound Velocity Features:


• 1370 – 1700 m/s • Selectable Receiver
• Resolution 1 m/s • Bandwidth for shallow/deep water echo
sounding
Transducer Draft Setting • Silas compatible output for sediment analysis
• 0 – 15 m

Depth Display
• On control PC and LCD display

Clock
• Internal battery backed time, elapsed time and
date clock

Annotation
• Internal – date, time, optional GPS position
from built-in Rx.
• External – up to 80 ASCII characters from
RS232 Serial or Ethernet port

Marketed By

Making
technology
work for you!
Oceanscan Limited reserve the right to alter or amend any published specication without notice.