Hilti PROFIS Engineering 3.0.

92

www.hilti.com.sg
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

Specifier's comments:

1 Anchor Design
1.1 Input data

Anchor type and diameter: HIT-RE 500 V4 + HAS 8.8 M24


Return period (service life in years): 50
Item number: not available (element) / 2287553 HIT-RE 500 V4
(adhesive)
Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 180.0 mm (hef,limit = - mm)
Material: 8.8
Evaluation Service Report: ETA 20/0541
Issued I Valid: 09/06/2023 | -
Proof: SOFA based on EN 1992-4, Chemical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 25.0 mm

Anchor plate
CBFEM
: lx x ly x t = 400.0 mm x 1,100.0 mm x 25.0 mm;

Profile: Flat bar, ; (L x W x T) = 20.0 mm x 1,000.0 mm


Base material: 2
uncracked concrete, C30/37, fc,cyl = 30.00 N/mm ; h = 600.0 mm, Temp. short/long: 30/30 °C,
User-defined partial material safety factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: reinforcement spacing < 150 mm (any Ø) or < 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12.0 [mm] + close mesh (stirrups, hangers) s <= 100.0
[mm]
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present

CBFEM
- The anchor calculation is based on a component-based Finite Element Method (CBFEM)

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 Combination 1 N = 0.000; Vx = 0.000; Vy = 700.000; no no 105
Mx = 0.000; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

1.2 Load case/Resulting anchor forces 11 y 12

Anchor reactions [kN] 9 10


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.373 56.352 0.229 56.351 7 8
2 0.374 56.356 -0.213 56.356 x
3 0.000 58.087 0.252 58.086
5 6
4 0.000 58.092 -0.247 58.092
5 0.000 59.314 -0.118 59.314
6 0.000 59.317 0.104 59.317 3 4
7 0.314 59.597 -0.276 59.596
8 0.317 59.594 0.254 59.593
1 2
9 0.684 58.937 -0.513 58.934
10 0.689 58.926 0.506 58.924 Tension
11 0.033 57.726 -0.404 57.725
12 0.033 57.713 0.426 57.711

resulting tension force in (x/y)=(0.3/36.9): 2.817 [kN]


resulting compression force in (x/y)=(0.0/0.0): 0.000 [kN]

Anchor forces are calculated based on a component-based Finite Element Method (CBFEM)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.3 Tension load EN 1992-4, Section 7.2.1

Load [kN] Capacity [kN] Utilization bN [%] Status


Steel Strength* 0.689 188.267 1 OK
Combined pullout-concrete cone failure** 2.070 242.729 1 OK
Concrete Breakout Failure** 2.070 362.457 1 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

1.3.1 Steel Strength

N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NEd [kN]


282.400 1.500 188.267 0.689

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.3.2 Combined pullout-concrete cone failure

N
NEd £ NRd,p = Rk,p EN 1992-4, Table 7.1
gM,p
0 Ap,N
NRk,p = NRk,p · 0
· y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13)
Ap,N
0
NRk,p = y sus · t Rk · p · d · hef EN 1992-4, Eq. (7.14)
y sus =1 EN 1992-4, Eq. (7.14a)

scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef EN 1992-4, Eq. (7.15)


0,5
y g,Np
0
= y g,Np -
s
s
( ) · (y g,Np - 1) ³ 1.00
cr,Np
0
EN 1992-4, Eq. (7.17)
1,5
0
y g,Np = √n - (√n - 1) · (tt )
Rk

Rk,c
³ 1.00 EN 1992-4, Eq. (7.18)
k3
t Rk,c = · √hef · fck EN 1992-4, Eq. (7.19)
p·d
c
y s,Np = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.20)
ccr,Np £
1
y ec1,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec1,N £
1+ (
scr,Np )
1
y ec2,Np = 1.00 EN 1992-4, Eq. (7.21)
2 · ec2,N £
1+ (
scr,Np )
2 0 2 2 2
Ap,N [mm ] Ap,N [mm ] t Rk,ucr,20 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ]
695,600 291,600 13.00 540.0 270.0 300.0 30.00
0
yc t Rk,ucr [N/mm ]
2
k3 t Rk,c [N/mm ]
2
y g,Np y g,Np
1.041 13.54 11.000 10.72 1.000 1.000

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.4 0.999 54.6 0.832 1.000 1.000
0
y sus asus y sus
0.720 0.000 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NEd [kN]
183.733 364.093 1.500 242.729 2.070

Group anchor ID
7-12

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.3.3 Concrete Breakout Failure

N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = 1.00 EN 1992-4, Eq. (7.6)
2 · eN,1 £
1+ (
scr,N )
1
y ec2,N = 1.00 EN 1992-4, Eq. (7.6)
2 · eN,2 £
1+ (
scr,N )
z
y M,N = 2.0 - 1.00 EN 1992-4, Eq. (7.7)
1.5 · hef ³

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
695,600 291,600 270.0 540.0 30.00

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.4 0.999 54.6 0.832 1.000 1.000
0
z [mm] y M,N k1 NRk,c [kN] gM,c NRd,c [kN] NEd [kN]
30.9 1.886 11.000 145.500 1.500 362.457 2.070

Group anchor ID
7-12

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.4 Shear load EN 1992-4, Section 7.2.2

Load [kN] Capacity [kN] Utilization bV [%] Status


Steel Strength (without lever arm)* 59.597 112.960 53 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 700.000 758.168 93 OK
Concrete edge failure in direction x-** 350.011 336.015 105 not recommended

* highest loaded anchor **anchor group (relevant anchors)

1.4.1 Steel Strength (without lever arm)

V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)

0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
141.200 1.000 141.200 1.250 112.960 59.597

1.4.2 Pryout Strength (Concrete Breakout Strength controls)

V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · min {NRk,c; NRk,p} EN 1992-4, Eq. (7.39c)
0 A
NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)

2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
1,139,600 291,600 270.0 540.0 2.000 30.00

ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N y M,N


0.0 1.000 0.0 1.000 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c,p VRd,cp [kN] VEd [kN]
11.000 145.500 1.500 758.168 700.000

Group anchor ID
1-12

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.4.3 Concrete edge failure in direction x-

V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2

= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)

lf [mm] dnom [mm] k9 a b 2


fc,cyl [N/mm ]
180.0 24.00 2.400 0.077 0.060 30.00
2 0 2
c1 [mm] Ac,V [mm ] Ac,V [mm ]
300.0 855,000 405,000

y s,V y h,V aV [°] y a,V ec,V [mm] y ec,V y re,V


1.000 1.000 89.71 2.000 0.5 0.999 1.000
0
VRk,c [kN] kT gM,c VRd,c [kN] VEd [kN]
119.523 1.0 1.500 336.015 350.011

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.5 Combined tension and shear loads (EN 1992-4, Section 7.2.3)
Steel failure

bN bV a Utilization bN,V [%] Status


0.002 0.528 2.000 28 OK

a a
bN + bV £ 1.0

Concrete failure

bN bV a Utilization bN,V [%] Status


0.009 1.042 1.000 88 OK

(bN + bV) / 1.2 £ 1.0

1.6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates as per current regulations (ETAG 001/Annex C, EOTA
TR029, etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor
plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates
the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.
The proof if the rigid base plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for
agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Characteristic bond resistances depend on short- and long-term temperatures.
• Edge reinforcement is not required to avoid splitting failure
• Design is only valid if hole is filled to remove clearance, clearance as per EN 1992-4 Table 6.1
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The anchor design methods in PROFIS Engineering require rigid anchor plates, as per current regulations (AS 5216:2021, ETAG 001/Annex
C, EOTA TR029 etc.). This means that the anchor plate should be sufficiently rigid to prevent load re-distribution to the anchors due to
elastic/plastic displacements. The user accepts that the anchor plate is considered close to rigid by engineering judgment."
• The characteristic bond resistances depend on the return period (service life in years): 50

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

1.7 Installation data


2 2
Anchor plate, steel: S 355; E = 210,000.00 N/mm ; fyk = 355.00 N/mm Anchor type and diameter: HIT-RE 500 V4 + HAS 8.8 M24
Profile: Flat bar, ; (L x W x T) = 20.0 mm x 1,000.0 mm Item number: not available (element) / 2287553 HIT-RE
500 V4 (adhesive)
Hole diameter in the fixture: df = 26.0 mm Maximum installation torque: 200 Nm
Plate thickness (input): 25.0 mm Hole diameter in the base material: 28.0 mm
Hole depth in the base material: 180.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 236.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HIT-RE 500 V4 injection mortar with 180 mm embedment h_ef, M24, Steel galvanized, Hammer drilled
installation per ETA 20/0541, with annular gaps filled with Hilti Filling set or any suitable gap solutions

1.7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Torque wrench
the hole
• Proper diameter wire brush

y
200.0 200.0
50.0

11 12
200.0

9 10
550.0
200.0

7 8
200.0

x
5 6
200.0

550.0

3 4
200.0

1 2
50.0

100.0 200.0 100.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y Anchor x y c-x c+x c-y c+y
1 -100.0 -500.0 300.0 500.0 1,125.0 - 7 -100.0 100.0 300.0 500.0 1,725.0 -
2 100.0 -500.0 500.0 300.0 1,125.0 - 8 100.0 100.0 500.0 300.0 1,725.0 -
3 -100.0 -300.0 300.0 500.0 1,325.0 - 9 -100.0 300.0 300.0 500.0 1,925.0 -
4 100.0 -300.0 500.0 300.0 1,325.0 - 10 100.0 300.0 500.0 300.0 1,925.0 -
5 -100.0 -100.0 300.0 500.0 1,525.0 - 11 -100.0 500.0 300.0 500.0 2,125.0 -
6 100.0 -100.0 500.0 300.0 1,525.0 - 12 100.0 500.0 500.0 300.0 2,125.0 -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

2 Anchor plate rigidity check

2.1 Input data


Anchor plate: Shape: Rectangular
lx x ly x t = 400.0 mm x 1,100.0 mm x 25.0 mm
Calculation: Anchor Plate Rigidity Check
Material: S 355; Fy = 355.00 N/mm²; εlim = 5.00%
Anchor type and size: HIT-RE 500 V4 + HAS 8.8 M24, hef = 180.0 mm
Anchor stiffness: The anchor is modeled considering stiffness values determined from load displacement curves tested in an
independent laboratory. Please note that no simple replacement of the anchor is possible as the anchor
stiffness has a major impact on the load distribution results.
Design method: EN-based design using component-based FEM
Stand-off installation: eb = 0.0 mm (No stand-off); t = 25.0 mm
Profile: Custom; (L x W x T x FT) = 20.0 mm x 1,000.0 mm x - x -
Material: S 235; Fy = 235.00 N/mm²; εlim = 5.00%
Eccentricity x: 0.0 mm
Eccentricity y: 0.0 mm
Base material: Uncracked concrete; C30/37; fc,cyl = 30.00 N/mm²; h = 600.0 mm; E = 33,000.00 N/mm²; G = 13,750.00
N/mm²; v = 0.20
Welds (profile to anchor plate): Type of redistribution: Plastic
Material: S 355
Mesh size: Number of elements on edge: 8
Min. size of element: 10.0 mm
Max. size of element: 50.0 mm

2.2 Anchor plate classification


Results below are displayed for the decisive load combinations: Combination 1
Anchor tension forces Equivalent rigid anchor plate (CBFEM) Component-based Finite Element Method
(CBFEM) anchor plate design
Anchor 1 0.000 kN 0.373 kN
Anchor 2 0.000 kN 0.374 kN
Anchor 3 0.000 kN 0.000 kN
Anchor 4 0.000 kN 0.000 kN
Anchor 5 0.000 kN 0.000 kN
Anchor 6 0.000 kN 0.000 kN
Anchor 7 0.000 kN 0.314 kN
Anchor 8 0.000 kN 0.317 kN
Anchor 9 0.046 kN 0.684 kN
Anchor 10 0.046 kN 0.689 kN
Anchor 11 0.188 kN 0.033 kN
Anchor 12 0.188 kN 0.033 kN

User accepted to consider the selected anchor plate as rigid by his/her engineering judgement. This means the anchor design guidelines can
be applied.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

11
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 12
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

2.3 Warnings
● By using the CBFEM calculation functionality of PROFIS Engineering you may act outside the applicable design codes and your specified
anchor plate may not behave rigid. Please, validate the results with a professional designer and/or structural engineer to ensure suitability
and adequacy for your specific jurisdiction and project requirements.
● The anchor is modeled considering stiffness values determined from load displacement curves tested in an independent laboratory.
Please note that no simple replacement of the anchor is possible as the anchor stiffness has a major impact on the load distribution
results.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

12
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 13
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

3 Summary of results
Load combination Max. utilization Status
Anchors Combination 1 105% NOT OK

Fastening does not meet the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

13
Hilti PROFIS Engineering 3.0.92

www.hilti.com.sg
Company: Page: 14
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Concrete - Mar 22, 2024 Date: 22/03/2024
Fastening point:

4 Remarks; Your Cooperation Duties


● Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,
formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc.,
that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be
conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based
essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the
relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and
cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility.
The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and
the relevance of the results or suitability for a specific application.
● You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you
do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the
Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery
of lost or damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

14