MEASUREMENT
Tested Tough. Trusted Safe.
Clamp Meters
Large Jaw Size
CL900 - 2" (5 cm)
CL800-600 - 1.38" (3.5 cm)
NCV Sensing
Antenna detects
presence of
AC voltage
Arrow Markings
for optimal wire Work Light (CL800 only)
placement
Data HOLD
on/off button
Magnetic Hanger with and without
strap 69417 & 69445 (optional)
Function Selection
Switch; functions
vary on models
Clamp
Trigger NCV Mode
on/off button
LCD Display
Backlit LCD Screen
CL800
AC Voltage (Volts) 1000V 1000V 1000V 1000V
True RMS
Audible Continuity
Backlight
CL700 Temperature –
-14° – 1000°F -14° – 1000°F
–
(-26° – 538°C) (-26° – 538°C)
The CL700 is an auto-ranging True Root- Differential
Mean Squared (TRMS) digital clamp meter – – – –
Temperature
that measures AC current via the clamp, Digital Temperature
– – – –
Calibration
and measures AC/DC voltage, resistance,
continuity, frequency, capacitance, and Low Impedance –
tests diodes via test leads, and temperature Low-Pass Filter – – – –
via a thermocouple probe. It also features a
Low Impedance (LoZ) mode for identifying Inrush Current 2000A – – –
and eliminating ghost or stray voltages. Non-Contact
Voltage Testing
Auto Ranging
Range Hold
Data Hold
The CL600 is an auto-ranging True Root- Capacitance Test 6000 µF 6000 µF 6000 µF –
Mean Squared (TRMS) digital clamp meter Frequency /
1Hz – 500kHz 1Hz – 500kHz 1Hz – 500kHz –
that measures AC current via the clamp, Duty Cycle
and measures AC/DC voltage, resistance, Max / Min
continuity, and tests diodes via test leads.
Relative Mode – – – –
Available As Available As Available As Available As
Magnet Mount
Accessory Accessory Accessory Accessory
Worklight – – –
Auto-Power Off
CAT III CAT IV
1000V 600V 2m
LCD Display Count 6000 6000 6000 6000
IP40
Specifications subject to change.
Clamp Meters
Large Jaw Size
1.38" (3.5 cm)
NCV Sensing
Antenna detects
presence of
AC voltage
Arrow Markings
for optimal wire
placement
Data HOLD
on/off button
Function Selection
Switch; functions
vary on models Reverse contrast
display on CL390
Clamp
Trigger
NCV SEL Mode
on/off button
LCD Display
Ingress Protection – – – –
Electrical Safety CAT III 600V CAT III 600V CAT III 600V CAT III 600V
CL320 AC Voltage (Volts) 600V 600V 600V 600V
The CL320 is an HVAC auto-ranging True
Root-Mean Squared (TRMS) digital clamp DC Voltage (Volts) 600V 600V 600V 600V
meter that measures 400A AC current AC + DC Voltage – – – –
via the clamp; NCV with the sensor; AC/
DC voltage, DC micro amps, resistance, AC Current (Amps) 400A 400A 400A 400A
capacitance, frequency, duty cycle, diode DC Current (Amps) 400A – – –
test, and continuity via test leads; and
temperature via a thermocouple. Ohms (Resistance) 40MΩ 40MΩ 20MΩ 20MΩ
AC Millivolts –
DC Millivolts
CL220
DC Microamps – –
True RMS –
The CL220 is an auto-ranging True Root-
Mean Squared (TRMS) digital clamp Audible Continuity
meter that measures 400A AC current via Reverse
Backlight
the clamp; NCV with the sensor; AC/DC Contrast Display
-40° – 1832°F -40° – 1832°F -40° – 1832°F
voltage, resistance, and continuity via test Temperature
(-40° – 1000°C) (-40° – 1000°C) (-40° – 1000°C)
–
leads; and temperature via a thermocouple. Differential
– – – –
Temperature
Digital Temperature
– – – –
Calibration
Low Impedance – – – –
Auto-Power Off
CAT III
600V 2m
LCD Display Count 4000 4000 2000 2000
DC Voltage (Volts) 1000V 1000V 1000V 1000V 1000V 600V 600V 600V 600V
AC + DC Voltage – – – – – – – –
AC Current (Amps) 2000A 600A 600A 600A 600A 400A 400A 400A 400A
Ohms (Resistance) 60MΩ 60MΩ 60MΩ 60MΩ 60MΩ 40MΩ 40MΩ 20MΩ 20MΩ
AC Millivolts – –– – – – –
DC Millivolts
DC Microamps – – – – – –
True RMS –
Audible Continuity
Reverse
Backlight
Contrast Display
-14° – 1000°F -14° – 1000°F -40° – 1832°F -40° – 1832°F -40° – 1832°F -40° – 1832°F
Temperature – – –
(-26° – 538°C) (-26° – 538°C) (-40° – 1000°C) (-40° – 1000°C) (-40° – 1000°C) (-40° – 1000°C)
Differential
– – – – – – – –
Temperature
Digital Temperature Calibration – – – – – – – –
Low Impedance – – – – –
Low-Pass Filter – – – – – – – –
Range Hold
Data Hold
Diode Test – –
Relative Mode – – – – – – –
Available As Available As Available As Available As Available As Available As Available As Available As Available As
Magnet Mount
Accessory Accessory Accessory Accessory Accessory Accessory Accessory Accessory Accessory
Worklight – – – – – – – –
Auto-Power Off
LCD Display Count 6000 6000 6000 6000 6000 4000 4000 2000 2000
Specifications subject to change.
FEATURES MM700 MM600 MM400 MM300
Drop Protection 6.6' (2 m) 6.6' (2 m) 3.3' (1 m) 3.3' (1 m)
DC Millivolts
AC Milliamps –
DC Milliamps
AC Microamps –
DC Microamps
True RMS – – –
Audible Continuity
Backlight –
0° – 1500°F 0° – 1000°F 0° – 1000°F
Temperature –
(-18° – 816°C) (-18° – 538°C) (-18° – 538°C)
Low Impedance – – –
Auto Ranging –
Range Hold –
Data Hold
Diode Test
Lead Warning – –
Bar Graph – – –
Available As Available As Available As Available As
Magnetic Mount
Accessory Accessory Accessory Accessory
Auto-Power Off –
Battery Test – – –
Lead Storage
LCD Display
Function
Buttons
Function
Selector
Switch
Kickstand
Meter shown
actual size.
MM700
The MM700 is an auto-ranging True Root-
Mean-Squared (TRMS) digital multimeter
that measures AC/DC voltage, AC/DC
current, and resistance. It also measures
temperature, capacitance, frequency, duty-
cycle, and tests diodes and continuity.
The MM600 is an auto-ranging digital DC Voltage (Volts) 1000V 1000V 600V 600V
multimeter that measures AC/DC voltage,
AC Current (Amps) 10A 10A 10A –
AC/DC current, and resistance. It also
measures temperature, capacitance, DC Current (Amps) 10A 10A 10A 10A
frequency, duty-cycle, and tests diodes
and continuity. Ohms (Resistance) 40MΩ 40MΩ 40MΩ 2MΩ
DC Millivolts
AC Milliamps –
DC Milliamps
AC Microamps –
DC Microamps
MM400 True RMS – – –
The MM400 is an auto-ranging digital
multimeter that measures AC/DC voltage, Audible Continuity
AC/DC current, and resistance. It also
Backlight –
measures temperature, capacitance,
frequency, duty-cycle, and tests diodes 0° – 1500°F 0° – 1000°F 0° – 1000°F
Temperature –
(-18° – 816°C) (-18° – 538°C) (-18° – 538°C)
and continuity.
Low Impedance – – –
Auto Ranging –
Range Hold –
Data Hold
Diode Test
Battery Test – – –
NCVT-4IR
battery compartment, heavy-duty Incorporates a 66-Foot (20 m) Laser
pocket clip, and recessed buttons Distance Meter that can measure in
increase product durability. Enhanced NCVT-4IR detects 12-1000V AC. meters, inches with decimals, inches
LED interface makes the product Designed specifically for HVAC with fractions, feet with decimals, or
easy-to-understand; light indicator applications. This 4:1 distance-to- feet with fractions. The laser distance
clearly marks range being used for spot ratio IR thermometer measures meter functions independently from
testing. from -22 to 482° F (-30 to 250° C). the NCVT with a simple-to-use
Use convenient laser pointer to target intuitive interface.
measurement area for temperature
measurement.
NCVT-3P
CAT IV
1000V
Electrical Safety CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V CAT IV 1000V
Voltage 50-1000V AC Range 1: 12-1000V AC Range 1: 12-1000V AC 12-1000V AC Range 1: 12-1000V AC 12-1000V AC
Range 2: 70-1000V AC Range 2: 70-1000V AC Range 2: 70-1000V AC
Frequency Range 50-500Hz 50-500Hz 50-500Hz 50-500Hz 50-500Hz 50-500Hz
Auto-Power Off
Flashlight – – – – –
Distance Measuring – – – – –
Pocket Clip
CAT IV
600V 2m IP40
Accessories
69409
69410
Line Splitter 10x
Measure current up to
15A without splitting
the power cord