SUB-CONTRACTOR: OCEAN VANTAGE ENGINEERING SDN. BHD. DISCIPLINE: CIVIL & STRUCTURE
NOTES/COMMENTS:
FOR CONTRACTOR
FOR COMPANY
APPROVED NAME:
APPROVED WITH
POSITION:
COMMENT
REJECTED SIGN/DATE:
COMMENTS IF ANY:
BAGSF2-GEN-EXE-PES-00-QAC-PLN-0002-A_att 1
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
OWNER REVIEW
IFC FDC
IFA Mark -Up
AFC For Info
Reviewed
Reviewed with Minor
Comment
Not Approved &
Resubmit
For Information
Seen: Seen :
Sign/Date Sign/Date
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
OWNER REVIEW
IFC FDC
IFA Mark -Up
AFC For Info
Reviewed
Reviewed with Minor
Comment
Not Approved &
Resubmit
For Information
Seen: Seen :
Sign/Date Sign/Date
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
BAGSF2/MAR/OV/0083
“Polyflow” Water pipes are certified by SIRIM QAS International Sdn Bhd
Products Standards Comply: - MS 1058 (Water Supply)
- MS 1086 (For Gaseous Fuels)
- MS 1058 (For cable/communication/conduit systems)
- ISO 4427(Water Supply)
- ISO 4437(For Gaseous Fuels)
- BS EN50086-2-4 (For cable/communication/conduit systems)
- ASTM D3350(For cable/communication/conduit systems)
BAGSF2/MAR/OV/0083
1
BAGSF2/MAR/OV/0083
Our Products
WATER CABLE/COMMUNICATION GAS
PE PIPES PE PIPES PE PIPES
FITTINGS
1
BAGSF2/MAR/OV/0083
• The weight of PE pipe is only about 1/5 of a steel pipe of a similar size.
• Easy handling.
• Significant savings in costs of handling and transportation.
Light
Weight
• Natural flexibility.
• Can be bent to conform to terrain contours and soil movements.
• Can be bent at a minimum radius of 25 to 40 times the pipe diameter.
• Long length without joints.
Flexibility
Ultra-
Violet
Resistance
• Physiologically harmless.
• Polyflow PE Pipes are protected • Free from toxicity and does not
against Ultra-Violet radiation affect taste of drinking water.
(sunlight). Non-toxic
and
Odorless
• Lower overall
Lower cost results from
Overall all the good
Project Cost properties of PE
Pipes.
Superior
Flowability
• PE Pipes have extremely smooth inner surface giving lowest
flow resistance.
• No scaling or corrosion encrustation.
Impact
Resistance
• High flexural and impact strength.
• Will not easily crack, break or fracture
when handled roughly.
Applications Back-Up
of PE Pipes Service from
1. Potable Water Distribution - On land or
underwater.
Manufacturer
2. Irrigation, Agriculture and Aquaculture.
3. Sewerage and Effluent Disposal. • Installation & Welding Services.
4. Pipes Relining. • Technical Advice Available.
5. Conveyance of Chemicals. • Training on Welding provided for
6. Gas Distribution. Pipe Installation.
7. Cable/Communication Protection Pipe/
Conduit System.
3
BAGSF2/MAR/OV/0083
DIMENSIONS:
PE80
Nominal
OD NB PN 6 PN 8 PN 10 PN 12.5 PN 16
SDR21 SDR17 SDR13.6 SDR11 SDR9
(mm) (inches) t (min) id t (min) id t (min) id t (min) id t (min) id
16
20 2.0 15.6 2.3 15.0
25 2.0 20.6 2.3 20.0 3.0 18.6
32 1.0 2.0 27.6 2.4 26.8 3.0 25.6 3.6 24.2
40 2.4 34.8 3.0 33.4 3.7 32.0 4.5 30.4
50 1.5 2.4 44.8 3.0 43.6 3.7 42.0 4.6 40.2 5.6 38.0
63 2.0 3.0 56.6 3.8 54.8 4.7 53.0 5.8 50.6 7.1 47.8
75 2.5 3.6 67.2 4.5 65.4 5.6 63.0 6.8 60.6 8.4 57.2
90 3.0 4.3 80.8 5.4 78.4 6.7 75.8 8.2 72.6 10.1 68.6
110 4.0 5.3 98.6 6.6 96.0 8.1 92.8 10.0 88.8 12.3 84.0
125 5.0 6.0 112.2 7.4 109.2 9.2 105.4 11.4 100.8 14.0 95.4
160 6.0 7.7 143.6 9.5 139.8 11.8 135.0 14.6 129.2 17.9 122.2
180 6.5 8.6 161.8 10.7 157.4 13.3 151.8 16.4 145.4 20.1 137.6
200 9.6 179.6 11.9 174.8 14.7 169.0 18.2 161.6 22.4 152.8
225 8.0 10.8 202.2 13.4 196.6 16.6 190.0 20.5 181.8 25.2 171.8
250 9.0 11.9 224.8 14.8 218.8 18.4 211.2 22.7 202.2 27.9 191.2
280 10.0 13.4 251.6 16.6 245.0 20.6 236.6 25.4 226.4 31.3 214.0
315 11.0 15.0 283.4 18.7 275.6 23.2 266.0 28.6 254.8 35.2 240.8
355 13.0 16.9 319.4 21.2 310.4 26.1 300.0 32.2 287.2 39.7 271.4
400 14.0 19.1 359.6 23.7 350.0 29.4 338.0 36.3 323.6 44.7 306.0
450 16.0 21.5 404.6 26.7 393.8 33.1 380.2 40.9 364.0 50.3 344.2
500 18.0 23.9 449.6 27.7 439.4 36.8 422.6 45.4 404.4 55.8 382.6
560 20.0 26.7 503.8 33.2 490.0 41.2 473.2 50.8 453.2
630 22.0 30.0 566.8 37.4 551.2 46.3 532.6 57.2 509.6
710 33.9 638.6 42.1 621.4 52.2 600.2
800 38.1 719.8 47.4 700.2 58.8 676.4
900 42.9 809.8 53.3 787.8
1000 47.7 899.6 59.3 875.2
LENGTHS AVAILABLE:
OD 20/25/32 mm 100/200/300 m coiled lengths
OD 50/63 mm 100 m coiled lengths
OD 75/90/110 mm 50 m coiled & 6.1 m straight lengths
OD 160 mm above Available on request
KEY:
OD : Outer Diameter
t (min) : Minimum Wall Thickness
id : Internal Diameter
PN : Nominal Pressure (bar)
NB : Nominal Bore of Metal Pipes
SDR : Standard Dimension Ratio
DIMENSIONS:
PE100
Nominal
OD NB PN 6 PN 8 PN 10 PN 12.5 PN 16 PN 20
SDR26 SDR21 SDR17 SDR13.6 SDR11 SDR9
(mm) (inches) t (min) id t (min) id t (min) id t (min) id t (min) id t (min) id
16
20 2.0 15.6 2.3 15.0
25 2.0 20.6 2.3 20.0 3.0 18.6
32 1.0 2.0 27.6 2.4 26.8 3.0 25.6 3.6 24.2
40 2.0 35.6 2.4 34.8 3.0 33.4 3.7 32.0 4.5 30.4
50 1.5 2.0 45.6 2.4 44.8 3.0 43.6 3.7 42.0 4.6 40.2 5.6 38.0
63 2.0 2.5 57.6 3.0 56.6 3.8 54.8 4.7 53.0 5.8 50.6 7.1 47.8
75 2.5 2.9 68.8 3.6 67.2 4.5 65.4 5.6 63.0 6.8 60.6 8.4 57.2
90 3.0 3.5 82.4 4.3 80.8 5.4 78.4 6.7 75.8 8.2 72.6 10.1 68.6
110 4.0 4.2 101.0 5.3 98.6 6.6 96.0 8.1 92.8 10.0 88.8 12.3 84.0
125 5.0 4.8 114.8 6.0 112.2 7.4 109.2 9.2 105.4 11.4 100.8 14.0 95.4
160 6.0 6.2 146.8 7.7 143.6 9.5 139.8 11.8 135.0 14.6 129.2 17.9 122.2
180 6.5 6.9 165.4 8.6 161.8 10.7 157.4 13.3 151.8 16.4 145.4 20.1 137.6
200 7.7 183.6 9.6 179.6 11.9 174.8 14.7 169.0 18.2 161.6 22.4 152.8
225 8.0 8.6 206.6 10.8 202.2 13.4 196.6 16.6 190.0 20.5 181.8 25.2 171.8
250 9.0 9.6 229.6 11.9 224.8 14.8 218.8 18.4 211.2 22.7 202.2 27.9 191.2
280 10.0 10.7 257.4 13.4 251.6 16.6 245.0 20.6 236.6 25.4 226.4 31.3 214.0
315 11.0 12.1 289.4 15.0 283.4 18.7 275.6 23.2 266.0 28.6 254.8 35.2 240.8
355 13.0 13.6 326.2 16.9 319.4 21.2 310.4 26.1 300.0 32.2 287.2 39.7 271.4
400 14.0 15.3 367.6 19.1 359.6 23.7 350.0 29.4 338.0 36.3 323.6 44.7 306.0
450 16.0 17.2 413.6 21.5 404.6 26.7 393.8 33.1 380.2 40.9 364.0 50.3 344.2
500 18.0 19.1 459.6 23.9 449.6 27.7 439.4 36.8 422.6 45.4 404.4 55.8 382.6
560 20.0 21.4 514.8 26.7 503.8 33.2 490.0 41.2 473.2 50.8 453.2
630 22.0 24.1 579.2 30.0 566.8 37.4 551.2 46.3 532.6 57.2 509.6
710 27.2 652.8 33.9 638.6 42.1 621.4 52.2 600.2
800 30.6 735.6 38.1 719.8 47.4 700.2 58.8 676.4
900 34.4 827.2 42.9 809.8 53.3 787.8
1000 38.2 919.6 47.7 899.6 59.3 875.2
LENGTHS AVAILABLE:
OD 20/25/32 mm 100/200/300 m coiled lengths
OD 50/63 mm 100 m coiled lengths
OD 75/90/110 mm 50 m coiled & 6.1 m straight lengths
OD 160 mm above Available on request
KEY:
OD : Outer Diameter
t (min) : Minimum Wall Thickness
id : Internal Diameter
PN : Nominal Pressure (bar)
NB : Nominal Bore of Metal Pipes
SDR : Standard Dimension Ratio
5
BAGSF2/MAR/OV/0083
Testing Guidelines
for HDPE Water Pipelines
0.7
tabulated in Table A. 0.6
0.5
Table A. Recommended Maximum Working pressure at 30°C 0.4
0.3
PIPE MATERIAL / NOMINAL RECOMMENDED MAXIMUM 0.2
TYPE PRESSURE WORKING PRESSURE (BAR) 0.1
16.0 12.8 0
20 25 30 35 40
PE80 12.5 10.0
Temperature °C
& 10.0 8.0
PE100 8.0 6.4
6.0 4.8
Compression Fittings
Dimension Specifications
(Conform to Standards: BS 5114, AS 4129, ISO 3458, ISO 3459, ISO 3501, ISO 3503 & ISO 14236)
STRAIGHT COUPLER
1. 20mm x 20mm 5. 63mm x 63mm
2. 25mm x 25mm 6. 75mm x 75mm
3. 32mm x 32mm 7. 90mm x 90mm
4. 50mm x 50mm 8. 110mm x 110mm
REDUCING COUPLER
1. 25mm x 20mm 6. 50mm x 32mm 11. 75mm x 63mm
2. 32mm x 20mm 7. 63mm x 25mm 12. 90mm x 63mm
3. 32mm x 25mm 8. 63mm x 32mm 13. 90mm x 75mm
4. 50mm x 20mm 9. 63mm x 50mm 14. 110mm x 90mm
5. 50mm x 25mm 10. 75mm x 50mm
7
BAGSF2/MAR/OV/0083
Compression Fittings
Dimension Specifications
(Conform to Standards: BS 5114, AS 4129, ISO 3458, ISO 3459, ISO 3501, ISO 3503 & ISO 14236)
EQUAL BEND
1. 20mm x 20mm 5. 63mm x 63mm
2. 25mm x 25mm 6. 75mm x 75mm
3. 32mm x 32mm 7. 90mm x 90mm
4. 50mm x 50mm 8. 110mm x 110mm
EQUAL TEE
1. 20mm x 20mm 5. 63mm x 63mm
2. 25mm x 25mm 6. 75mm x 75mm
3. 32mm x 32mm 7. 90mm x 90mm
4. 50mm x 50mm 8. 110mm x 110mm
REDUCING TEE
1. 25mm x 20mm 7. 63mm x 50mm
2. 32mm x 20mm 8. 75mm x 50mm
3. 32mm x 25mm 9. 75mm x 63mm
4. 50mm x 25mm 10. 90mm x 63mm
5. 50mm x 32mm 11. 90mm x 75mm
6. 63mm x 32mm 12. 110mm x 90mm
END CAP
1. 20mm x 20mm 5. 63mm x 63mm
2. 25mm x 25mm 6. 75mm x 75mm
3. 32mm x 32mm 7. 90mm x 90mm
4. 50mm x 50mm 8. 110mm x 110mm
Mechanical Clamp/
Tapping Saddles
(Conform to Standards: ISO 3607, ISO 3609, UNI EN12201, DIN 8072-8074 & DIN 8077)
Name of Part:
Hexagon Nut
Material:
Mild Steel - Zinc Plated
Name of Part:
Body - Bottom
Material: Name of Part:
Reinforce Polypropylene Hexagon Bolt
Material:
Mild Steel - Zinc Plated
9
BAGSF2/MAR/OV/0083
Fabricated Fittings
(Conform to Standards: MS 1058, ISO 4427, ASTM D3261, BS7291 & IS0 13953)
Z
Z
D
Z
r r
Z
Z D
Z Z
D D
Bends
D r Z (TEE)
Z (90o) Z (60o) Z (45o)
63 94 244 204 190 180
90 135 285 228 206 195
110 165 315 245 218 205
125 188 338 258 228 215
160 240 390 288 249 230
225 338 488 345 290 265
250 375 625 466 412 375
280 420 670 492 424 390
345 518 818 599 515 475
400 600 900 646 548 500
450 675 975 689 580 525
500 750 1100 783 665 600
560 840 1190 835 698 630
630 945 1295 896 741 665
Backing Flanges
and Stub Ends
D
k
H1
d2
H2
11
BAGSF2/MAR/OV/0083
Electrofusion Fittings
for Gas and Water Pipes
Fusion Coil
Pipe Wall
Fusion Coil
Cold zone | Fusion zone | Cold zone
Electrofusion fittings feature a unique resistance The effectiveness of electrofusion depends on:
element design, in the form of heating wire embedded a) Preparation of the jointing surfaces.
on/within the outer layer in the inner wall of the
b) Ensuring that the surfaces to be welded have
fittings. The fusion is achieved in the following way:
satisfactory contact during the welding and
cooling cycles.
The fittings are fixed with barcode labels which
contain specification including pipe size, fusion
pressure, heating temperature, SDR, heating/fusion/ The pipe surfaces to be fused need to be scraped to
cooling times etc. A controller with processor unit remove the surface oxidation layer prior to fusion.
and barcode reader will scan the barcode labels,
start the fusion cycle and automatically monitor the To prepare the jointing surfaces, the pipe surface
electrofusion jointing process. When electric current must be scraped with an appropriate pipe scraper, as
is applied via an Automatic Controller equipped with recommended by the pipe or fitting manufacturer, to
power cord leads to the fittings, the plastic around the remove the entire surface of the pipe over the area
heating elements in the fitting and on the pipe surface indicated for the fitting, to a depth of approximately
begins to melt and form a melt pool. With continued 0.3mm. Metal files, rasps, emery paper & etc. are
application of current, the melt pool deepens at the not suitable preparation tools. The scraped surface
pipe and fitting interface which in turn forces internal must be wiped with the recommended isopropanol
pressures to build up. impregnated pipe wipe, as recommended by the pipe
or fitting manufacturer, to remove any dust residue.
The increasing material expansion between pipe and The prepared surfaces must be completely dry before
fitting, which is hindered by the cold zones outside proceeding.
the Fusion (Hot) zone, leads to a buildup of a welding
pressure between pipe and fitting and a homogeneous All electrofusion fittings/couplings (regardless of
welding connection emerges. manufacturer) require the pipe to be restrained or
sufficiently supported on each side of the pipe to:
This process is known as co-crystallization between a) Restrict movement during the fusion and cooling
the melted pipe and fitting material. Re-solidification process.
during cooling phase forms a fusion joint which is as b) Alleviate or eliminate sources of stress and/or
strong as the pipe itself. strain until both the fusion cycle and the cooling
cycle are completed.
As a result of this electro-fusion process, every joint
will be sealed precisely to specification, automatically,
every time, minimizing the risk of human error.
Electrofusion Fittings
(Conform to Standards: BS EN12201-3, EN1555-3, ISO 4427-3 & ISO 4437-3)
ELECTROFUSION COUPLER
1. 20mm 6. 75mm 11. 180mm 16. 355mm
2. 25mm 7. 90mm 12. 225mm 17. 400mm
3. 32mm 8. 110mm 13. 250mm
4. 50mm 9. 125mm 14. 280mm
5. 63mm 10. 160mm 15. 315mm
ELECTROFUSION ELBOW
1. 20mm 5. 63mm 9. 125mm
2. 25mm 6. 75mm 10. 160mm
3. 32mm 7. 90mm 11. 180mm
4. 50mm 8. 110mm
45° ELBOW 90° ELBOW
ELECTROFUSION REDUCER
1. 32mm x 25mm 7. 63mm x 32mm 13. 110mm x 90mm 19. 125mm x 75mm
2. 32mm x 20mm 8. 63mm x 25mm 14. 110mm x 75mm 20. 125mm x 63mm
3. 50mm x 32mm 9. 63mm x 20mm 15. 110mm x 63mm 21. 160mm x 110mm
4. 50mm x 25mm 10. 90mm x 75mm 16. 110mm x 50mm 22. 160mm x 90mm
5. 50mm x 20mm 11. 90mm x 63mm 17. 125mm x 110mm 23. 180mm x 160mm
6. 63mm x 50mm 12. 90mm x 32mm 18. 125mm x 90mm
13
BAGSF2/MAR/OV/0083
PTS 11.14.01
DESIGN AND ENGINEERING OF BUILDINGS January 2017
Page 13 of 40
3.2.2
3.2.2 All buildings structural components shall be designed for the local maximum/minimum
condition i.e. wind, seismic, temperatures, soil condition, etc.
3.2.3 Structural design loads and criteria shall made references to PTS 11.10.01. Live Loads for
building, see UBBL 1984C-Forth Schedule and BS EN 1990 and BS EN 1991.
3.3.1 Drainage systems outside the area of 1.0 m from the building external wall shall comply with
PTS 11.12.03. Within the building boundary, the following minimum requirements are
applicable:
ii. The perimeter drains shall be made of either reinforced concrete or plastered
250mm thick brickwall U-shape drain. The drain shall be covered with precast
concrete or hot-dipped galvanised grating unless specified otherwise. Fiberglass
reinforced plastic may be used as drain cover, subject to Owner’s approval.
iii. Roof guttering with adequately sized with a min. of 100 mm diameter rainwater
down pipes shall be provided to discharge surface water into the oil-free.
iv. For water drainage system, the down pipes and fittings shall be UPVC material.
v. Rainwater down-pipes and other drain pipes shall not pass through electrical
equipment rooms or basements.
vi. The basements shall be provided with an emergency drain pit of 600 mm x 600
mm, depth approximately 250 mm, with cover. This drain pit shall be located near
the access opening to the basement, to facilitate easy connecting of a hose from
a movable emergency pump outside the building.
3.4.1 Complete water supply and plumbing system shall be designed to the various buildings
according to the minimum requirement of this PTS and shall comply with local authority,
codes and regulations.
3.4.2 A complete cold water piping system shall be designed for all buildings.
PTS 11.14.01
DESIGN AND ENGINEERING OF BUILDINGS January 2017
Page 14 of 40
3.4.3 Supply of hot water shall be designed for Pantry Room, kitchen, First Air Room, Rest Room
and wash room unless agreed or specified otherwise.
3.4.4 Substation Battery room shall be provided with an eye-wash and hand basin together with
floor drain for emergency and laboratory room shall be provided with emergency shower and
eye-wash.
3.4.5 For HVAC room, a tap, hose connection and a floor drain shall be provided.
3.4.6 Garden water shall be made available by installing taps and hose connections at convenient
locations on the exterior walls of the buildings and proposed garden areas.
3.4.7 Piping materials shall be copper for hot water and copper or ABS (Acrylonitrile Butadiene
Styrene) or approved equivalent for cold water.
3.4.8 The minimum flow rates for hot and cold water shall be designed as follows:
Shower 7 7
Hand Basin 7 10
3.4.9 All pipes and fittings shall be hydrostatically tested after installation at 1.5 times the system
pressure. Individual stop valve and unions shall be installed at every wet room of all buildings
so that any fitments can be isolated and replaced for easy operation and maintenance.
3.5.1 Buildings sanitary and sewerage system shall be designed, installed and tested as described in
this PTS, PTS 11.12.03 and in compliance with local authority, standard codes and regulations.
3.5.2 Materials shall be selected and laid in such a manner that underground pipes or fittings, traps,
pit, etc., shall not give rise to leakage. All drain pipes shall be resistant to corrosion, erosion,
and the action of acids, detergents, hot water or other wastes to be drained.
3.5.3 All sewer system shall be designed to provide self-cleansing velocities and easy access for
clearing of obstructions. Clean-out or access points within buildings shall have screwed or
bolted airtight covers. Interconnecting pits outside the buildings shall be provided with cast-
iron removable covers.
PTS 11.14.01
DESIGN AND ENGINEERING OF BUILDINGS January 2017
Page 15 of 40
ii. Purification of the effluent from the treating plants shall be designed, so that the
final effluent can be discharged into the natural storm water channels without
objections from the neighbours or local authorities.
iii. Prior to any back-filling, all underground drain and sewer pipes and pits shall be
water-tested in accordance with PTS 11.12.03.
3.6.1 The building shall be provided with the required climatic condition i.e., heating, ventilation
and air conditioning (HVAC), to maintain the temperature, relative humidity and air quality
within defined limits in order to provide reliable operation of electronic equipment and
acceptable human working conditions.
3.6.2 The system shall be able to maintain the temperature, relative humidity and air quality within
defined limit as outlined in the following specification, codes and standards;
i. PTS 12.24.01 Heating, Ventilation and Air Conditioning (HVAC) System for
Onshore Application.
3.6.3 Buildings requiring heating, air conditioning or ventilation shall have properly insulated roofs
and walls. The average thermal transmittance shall be:
3.6.4 All insulation materials shall be stable, fire-resistant or self-extinguishing and properly applied
to eliminate pinching and sagging to maintain their effectiveness. Insulation materials shall be
rot and vermin resistant. Materials that emit very toxic vapour in a fire shall not be used.
Noise from HVAC equipment transmitted through ducts shall not result in sound pressure
levels inside the room higher than 10 dB(A) below the maximum acceptable noise level in that
room.
Noise caused by HVAC installations shall be reduced by applying one or more of the following
measures: