PowlVac® Series 4 Circuit Breakers

ANSI PowlVac Circuit Breakers for 5kV through 38kV Applications


Designed to Meet your Requirements
One of our core values is continous improvement. With this in mind, we are constantly adapting and K Factor = 1.0 for constant interrupting
introducing new options and features to our circuit breakers. Need a solution for a reduced footprint rating
so that you can fit your equipment into an existing space? We have a narrow design that can meet this
requirement. Additionally, PowlVac circuit breakers have a variety of options, including manual and
Tested up to 10,000 operations
automatic racking as well as our intelligent devices. Low Maintenance Current Transfer
Upgraded Design Features and Enhancements 2 Second Short-Time
The PowlVac® Series 4 Breaker is the next generation of Powell metalclad vacuum circuit breakers since our
initial breaker was first introduced to the marketplace in 1982. Updates and design enhancements include: Wide variety of racking options
• Upgrade of Primary Disconnects on all 36-inch frame breakers, allowing a greater degree of
alignment tolerance between the circuit breaker and cell mounted stab assembly. Contact
assemblies are separable from the breaker stab assembly and can be removed or replaced for
maintenance and repairs.
• Secondary control wiring harnesses are now a universal design for each breaker frame size and rating.
• All Series 4 breakers now include a 32-pin secondary disconnect assembly. This upgraded secondary
disconnect is now a universal design for each breaker frame size and includes wiring for all control
options of Powell’s CBM® device. Four of the pins are reserved for future communications use.
• All Series 4 frames and wiring harnesses are designed to support installation of Circuit Breaker
Monitor® at the factory or in the field at a later date.
• Full interchangeability with older PowlVac® breakers can be accommodated with minor
modifications.
• All Series 4 PowlVac® breakers offer on-board racking as an option.

Powered by Safety ®
PowlVac® Circuit Breaker Series 4 Ratings

Cubicle ​
Voltage Short Circuit Power
Product Width ​BIL Continuous Current Rating
Class Rating Frequency
Form Factor
(kV) (in) (kA) (kV) (kV) ​1200A ​2000A ​3000A ​5000A2
36 ​60 19 ​​• •
5kV​ ​ PowlVac-ND® ​26
50 ​60 19 • •
36 ​60 19 • • •
5kV​ ​ PowlVac®​ ​36 50 ​60 19 ​​• • •
​63 60​ 19 • • •
25 ​95 36 • • •
36 ​95 36 • • •
​36 50 ​95 36 • • •
​15kV PowlVac®​
​63 ​95 36 • • •
​63G1 ​95 36 • • •
48 ​63G1 ​95 36 •
​27kV ​36 25 ​125 60 • •
PowlVac-ND®
29.8kV ​36 25 ​125 60 • •
25 ​125 60 • •
27kV ​PowlVac® 40
40​ 125 60 • •
25 ​150 80 • •
​PowlVac® 40
​38kV ​ ​ ​40 ​150 80 • •
​PowlVac® ​54 ​40 ​150 80 •
1
63G indicates a generator rated circuit breaker tested in accordance with C37.013
2
The 5000 amp circuit breaker is applied in stationary metal-enclosed applications. An isolation switch is required.