Professional Documents
Culture Documents
PG7 Polygraph
PG7 Polygraph
PG7 Polygraph
4 channels
2-Respiratory Sensors
Galvanic Skin Response (GSR) Sensor
Finger Pulse Sensor
PG Series Software
Expert Scoring System
Manual Scoring Interface
Instrument Case
Benefits
PG series polygraph are only products passed the identification of the Chinese Ministry of Public
Security..
Now there are more that 2000 sets of polygraph using in China and our international market are being
expanded day by day. The technology has reached the advanced level in the world.
We drafted the industry standard.
All products have our own IP rights.
The computerized polygraph system consists of sensors, main unit, microprocessor, and test software.
Sensor: it refers to the components which transfer the tested person’s physiological parameters such as
GSR, respiration and radioactivity to the analog signals
Main Unit: it refers to the device which converts the analog signals measured by each sensor to digital
signals, and then send them to microprocessor.
Microprocessor: The device processes the test prepare, test control, and data analysis.
Test Software: the executable files stored on microprocessor. It could process the edition, display,
print, storage, and analysis and automatic judgment
General Determined Parameters
Home / Forensic Comparison / PG7 Series Computerized Polygraph System – Sale Philippines
GRS (Galvanic Skin Response) Skin conductance changes along with the variety of skin sweet
gland’s activity. The tested person’s sympathetic nerve system activity can be reflected by the change
of GSR.
Cardio-activity: The polygraph determines cardio activity by indirect measurement, .ie. by some
special methods putted on the outside of body, it makes the blood preasure pass through some
intermedium such as organize and skin and them be transferred to the sense organ of the measuring
instrument. The psychological behavior is reflected by he change of cardio activity which includes
average flood pressure, blood volume and pulse.
Respiration: it refers to the changes of breath process parameters including breath frequency, the time
ratio of the breath out and breath in, which is caused by the change of physiology behavior. It
includes upper and lower chest assembly, i.e. breast and abdomen reparation.
Pulse: It refers to the elastic distortion of artery wall due to the extruded blood during the periodic beat
of heart.
Performance Paremeters
Size: 160*155*65mm;
Weight: 500g
Power source: Via computer through USB connection
Working environment temperature: -20°C ~+40°C
Working environment humidity: 20% ~80% (relative value)
Measurement of Pneumograph
Range: 0.1 ~5 times per second
Frequency: 0.05HZ – 20HZ
Resolution power: 1%
Measurement of GSR
Range: 10W- 10000W
Frequency: 0.01HZ – 2HZ
Resolution power: 1%
Measurement of blood pressure
Range: 50 ~70mmHg
Frequency: 0.05HZ – 5HZ
Resolution: 1%
Noise: <50dB
PG-7 Polygraph system
Designed as a basic testing system, PG-7 Polygraph system can be record four parameters. It’s simple and
practical, easy to operate and with stable performance.
User manual
Duralumin instrument case
3- year warranty on hardware
2- year warranty software upgrade for free
1- year warranty on accessories
Lifetime technical support