Anthony Power Beam® advantages

• Superior strength 3000Fb - 2.1E - 300Fv


• Individually wrapped
• Competitively priced with LVL & PSL
• Surface sealed for stability
• 3-1/2”, 5-1/2” & 7” widths
• Lighter than steel, LVL, and PSL Power Beam® Stamp
• I-Joist compatible depths
• Renewable resource
• No nail laminating - saves time & money
• Precut lengths up to 60’
• Compatible sizes with Anthony Power Joist®
MSR Lumber Stamp
The Anthony POWER BEAM® is a superior glued laminated beam
and header for use where reliable engineered wood applications
are required.
The 3-1/2” and 5-1/2” widths readily match 2x4 and 2x6 wall
framing. The POWER BEAM® depths also match all joist, truss,
LVL, PSL, and I-Joist floor or roof framing. The Anthony POWER
BEAM® uses readily-available Southern Pine lumber, sourced
from our own sawmill close by in Urbana, Arkansas.
Power Beam® Tag
Features
Moisture Control: POWER BEAM® consistently averages 12% Dimensional Stability: POWER BEAM® is a laminated wood
moisture, which is near equilibrium moisture content. product with different grades of lumber. This randomizes
any natural defect so there is greater beam strength and a
Code Evaluations/Standards:
higher degree of reliability. There is also less likelihood of
APA ICC ESR 1940, APA Product Report L 263;
warping, twisting, checking, cupping or shrinking when
ANSI A190.1-2012; APA Y-117-2008; and ASTM D-3737.
surface sealed.
AFP Power Sizer® Software: An easy-to-use structural analysis
Quality Assurance: POWER BEAM® is manufactured in
program capable of sizing AFP Power Products®.
accordance with ANSI A190.1-2012 (Structural Glued
Daily Proof Loading and Destructive Testing: Random beams Laminated Timber) with appropriate modifications. Plant
are loaded daily to 1.5 times design for Quality Assurance. implemented Total Quality Management, statistical process
SFI: Power Beam® is certified by Sustainable control procedures and APA-The Engineered Wood Association
Forestry Initiative. as our third party quality assurance program, ensure consistent
quality and performance in every POWER BEAM®.
The Anthony Forest Products Company, LLC Story
Anthony Forest Products Company, Due to complete computer optimization,
LLC (AFP), headquartered in El Dorado, the sawmill is now producing 30% more
Arkansas, has made some dramatic lumber out of the same size logs milled
changes to position itself for the twenty- previously.
first century. The generations of forest
Not only has our sawmill diversified with
products experience passed down through
changing markets, our laminating plants
the family have made this vision possible.
have diversified and have expanded to
When founded in 1916, the company was meet customer demands. Some of the
Anthony Brothers Lumber Company. The company’s fastest growth has been in the
name of the company has changed, and the engineered wood products sector. The
4th generation of the Anthony Family has demand for engineered wood products like
taken the reigns. I-Joists forced a need to totally modernize Laminating Plant - El Dorado, AR
The company operates a southern pine the El Dorado facility and to add an I-Joist
lumber producing mill in Urbana, plant in Canada in 2000.
Arkansas; and wood chip mills in The company joined forces with EACOM
Plain Dealing, Louisiana, and Troup, Timber Corporation of Montreal, Quebec,
Texas. The company also operates an Canada to produce the Power Joist®. The
engineered wood laminating plant in El Power Joist® is a high quality solid sawn
Dorado, Arkansas, a laminating plant in lumber flange I-Joist. Anthony Forest has
Washington, Georgia, and a joint venture contributed its superior customer service,
I-Joist plant, ANTHONY EACOM, Inc., in plant management, engineered wood
Sault Ste. Marie, Ontario, Canada. products knowledge, and distribution
The company’s sawmill and the El Dorado network to meet demands for an I-Joist
laminating plant have undergone massive to complement the Power Beam® I-Joist
compatible glulam. Laminating Plant - Washington, GA
modernization phases over the years.

Above: New supply warehouse for Quality Electric Company in El Dorado, Arkansas

2
Power Beam
®

Power Beam® Design Properties


Power Beam
Shear
T

Power Beam® Section Properties and Allowable Capacities

* Beam Weights are based on 40 pcf.


** Flexural Stress, Fb , shall be modified by Volume Factor, Cv , as outlined in ICC ESR-1940, APA Product Report-L263 and
APA-EWS Y 117 where;

Cv=KL x [(21/L)0.05 x (12/d)0.05 x (5.125/b)0.05] ≤1.0


where:
KL = loading coefficient (1.0 for uniformly distributed)
L = length of bending member between points of zero moment, ft.
d =depth of bending member, in.
b = width of bending member, in.

Tabulated Moment Capacities are based on a span of 21 feet and modified for other spans. Width and depth portions
of Volume Factor, Cv , are incorporated in tabulted Moment Capacities using Cdb Factor.

Note: Allowable design properties and load capacities are based on a load duration of 100 percent and dry use conditions.

3
Power Beam ®

Garage Door Headers 3000F


Power BeamDoorWindow,
Window, DoorDoor
and Garage
Key - Each cell contains
and Headers
1. Find
Steps in Using This Table:
two the row withheader
nominal the appropriate
sizes: roof loading
conditions (Live Load, Dead Load and LDF). Header
Row 1: Header size2.for bearing
Find length
the clear = 3.0"
opening that meets or exceeds the
Row 2: Header size for window,
bearingdoor or garage
length door size.
= 1-1/2"

Power Beam
3. Find the span of the trusses or rafters that frame
Steps in Using This Table: into the header.
1. Find the row with the appropriate roof
4. Select the loading
proper conditions
header size. (Live Load, Dead Load & LDF). Supported
2. Find the clear opening that
Key:meets
Each or
cellexceeds
containsthe
twowindow, door, or
nominal header garage door size.
sizes:
3. Find the span of the trusses or rafters that frame into the header. Framing - 20’
Row 1: Header size for bearing length = 3.0”
4. Select the proper header size. Single Story - No Storage
Row 2: Header size for bearing length = 1-1/2” Clear opening - 12’ Single Story - No Storage

POWER BEAM® Selection Table for Window, Door and Garage Door Headers - One Story Application

4
3
POWER BEAM® Selection Table for Window, Door and Garage Door Headers - One Story Application

Window, Door and Garage Door Header


Example Problem Load Duration Factor (LDF)

Load Conditions:
Live = 30 psf LDF Duration
Dead = 15 psf
1.00 10 years; normal loads
LDF = 1.15
Clear Opening: 12' 1.15 2 months; snow load
Span of Supported Roof Framing: 20' 1.25 7 days; non-snow or construction
Anthony POWER BEAM® Selected: 3-1/2 x 9-1/4 w/ 1 trimmer
Notes: (Single Story Applications)

10.
** These locations require a longer bearing or wider width beam. Consult PLF tables or AFP Power Sizer® Software for proper beam size.

45
Power Beam
Power Beam
®
Two-Story Applications
Steps in Using This Table:
Supported Framing - 20’ 3000F
1. Find the row with the appropriate roof loading
conditions (Live Load, Dead Load and LDF).
2. Find the clear opening that meets or exceeds the
window, door or garage door size.

Power Beam
3. Find the span of the trusses or rafters that frame
into the header.
4. Select the proper header size.
Key: Each cell contains two nominal header sizes:
Row 1: Header size for bearing length = 3.0” Clear
Row 2: Header size for bearing length = 1-1/2” Opening - 12’
Two Story Header

6
5
Window, Door and Garage Door Header
2-Story Application Example Problem Load Duration Factor (LDF)

Notes: (Two Story Application)


1. This table is for headers carrying floor, roof and wall loads.
2. Deflection is limited to L/360 for Live Load and L/240 for Total Load.
3. Design span is assumed to be the clear opening plus the bearing length of 1-1/2” (1 trimmer) or 3.0” (2 trimmers).
4. For bearing lengths longer than 3.0”, use the Allowable Floor Load Tables to get required header size. Use of longer bearing lengths
may allow the use of a smaller POWER BEAM®.
5. The header size is based on the load carried by 1/2 the span of the roof framing plus a 24” overhang plus 1/4 the span of the floor
load plus the wall load.
6. The wall load is assumed to be 100 PLF.
7. It is assumed that the header has the joist framing attached to its top, and is supported laterally at the bearing points.
8. For loads other than those shown, see the Floor Load PLF Table, or use a load condition that applies a higher load than you have.
9. Live Load reductions may be taken per IRC, IBC and ICC. Live Load reductions have not been taken to produce this table.
10. A 9-1/2” depth member may be substituted for a 9-1/4” member, and an 11-7/8” for an 11-1/4”, etc.

** These locations require a longer bearing or wider width beam. Consult PLF tables or AFP Power-Sizer Software for proper beam size.

67
Power Beam ®

Floor Girder Beams


Power Beam
Supported Joist Framing - 30’
Steps in Using This Table:
1. Find the row with the appropriate floor loading
conditions (Live Load, Dead Load and LDF).
2. Find the clear opening that meets or exceeds the
column spacing.
3. Find the span of the joists that frame into the

Power Beam girder beam.


4. Select the proper header size.
Column
Key: Each cell contains two nominal header sizes: Spacing - 14’

Row 1: Header size for bearing length = 3.0”


Row 2: Header size for bearing length = 1-1/2”
Floor Girder Beam

7
8
Notes: (Floor Girder Beams)
1. This table is for beams carrying floor loads only.
2. Deflection is limited to L/360 for Live Load and L/240 for Total Load.
3. The column spacing equals the design span. The beam is sized to consider simple or continuous beam applications.
4. For bearing lengths longer than 3.0”, use the Allowable Floor Load tables to get the required header size.
5. The beam size is based on the load carried by continuous span joists. The beam load is based upon the load from 5/8 of the span
of the supported floor joists. The intermediate bearing is assumed to be 6” or 3” corresponding to the 3” or 1-1/2” end bearing
conditions, respectively.
6. For simple span floor joists, multiply the sum of the spans by 0.80 and use the calculated span as span of supported joist framing.
7. It is assumed that the beam has the truss or joist framing attached to its top or to the beam sides using hangers, and is supported
laterally at the bearing points.
8. For load conditions other than those shown, see Floor Load Table, or use a load condition that applies a higher load than
you have.
9. Live Load reductions may be taken per IRC, ICC and IBC. Live Load reductions have not been taken to produce this table.
10. A 9-1/2” header may be used for a 9-1/4” header, and an 11-7/8” for an 11-1/4”, etc.
**These locations require a longer bearing or wider width beam. Consult PLF tables or AFP’s Power Sizer® Software
for proper beam size.

ex:
ex:
ex:
: ex:

1. Beam weight is included in all tables and does not have to be concentrated load applications must be analyzed separately
added to the applied load. or converted to an equivalent uniform load.
2. The top edge of the beam or header is assumed to have 5. Dead and Live Loads used to select a beam or header should
continuous lateral support. be equal to or greater than the actual loads applied.
3. Beams and headers are assumed to be used under dry 6. For other beam widths and depths, or for Architectural
conditions and normal temperatures. Grade Appearance Beams, please contact Anthony Forest
Products Company or your local dealer.
4. All tables assume uniform load conditions. Any

9
Power Beam
Allowable Floor Load Tables LDF = 1.0
These tables can be used to size simple span beams and headers that
3000F
Key: For each clear span there are three numbers:

Power Beam
carry uniform loads. The PLF loads must be calculated and take into Row 1: Maximum Total Load with LDF of 1.0, and deflection limited to L/240
Row 2: Maximum Live Load limited by deflection of L/360
account all floor and roof framing loads coming onto the beam or Row 3: Required Bearing Length in trimmer thickness
header. (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.)

10
Power Beam
Allowable Floor Load Tables LDF = 1.0
These tables can be used to size simple span beams and headers that
2800F
Key: For each clear span there are three numbers:

Power Beam
carry uniform loads. The PLF loads must be calculated and take into Row 1: Maximum Total Load with LDF of 1.0, and deflection limited to L/240
Row 2: Maximum Live Load limited by deflection of L/360
account all floor and roof framing loads coming onto the beam or Row 3: Required Bearing Length in trimmer thickness
header. (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.)

11
Power Beam
Allowable Roof Load Tables LDF = 1.15
These tables can be used to size simple span beams and headers
3000F
Key: For each clear span there are three numbers:

Power Beam
that carry uniform loads. The PLF loads must be calculated and Row 1: Maximum Total Load with LDF of 1.15, and deflection limited to L/180
Row 2: Maximum Live Load limited by deflection of L/240
take into account all roof loads only coming onto the beam or Row 3: Required Bearing Length in trimmer thickness
header. (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.)

12
Power Beam
Allowable Roof Load Tables LDF = 1.15
These tables can be used to size simple span beams and headers
2800F
Key: For each clear span there are three numbers:

Power Beam
that carry uniform loads. The PLF loads must be calculated and Row 1: Maximum Total Load with LDF of 1.15, and deflection limited to L/180
Row 2: Maximum Live Load limited by deflection of L/240
take into account all roof loads only coming onto the beam or Row 3: Required Bearing Length in trimmer thickness
header. (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.)

23 3/8

13
Power Beam
Allowable Roof Load Tables LDF = 1.25
These tables can be used to size simple span beams and headers
3000F
Key: For each clear span there are three numbers:

Power Beam
that carry uniform loads. The PLF loads must be calculated and Row 1: Maximum Total Load with LDF of 1.25, and deflection limited to L/180
Row 2: Maximum Live Load limited by deflection of L/240
take into account all roof loads only coming onto the beam or Row 3: Required Bearing Length in trimmer thickness
header. (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.)

*Allowable Roof Load data for 7” width 28F using a LDF=1.25 is available from Anthony Forest Products.

14
Power Beam
76600_Anthony30F:Anthony30F 5/23/11 2:08 PM Page 15

Anthony Power Beam®


Power Beam Notes for Allowable Load Tables

1. Values shown are the maximum uniform loads in pounds per lineal foot (PLF) that can be applied to the beam. Beam weight
has been subtracted from the allowable load. Load tables are based on dry use conditions.
2. LDF = Load Duration Factor per code requirements.
3. Bearing length shown is required at each end of header, and is based on an allowable bearing stress of 805 psi. The beam must
be sitting directly on top of 1 or more trimmers. A longer bearing length may be required depending on the material that the
beam is bearing on. For example, if the beam is sitting on a SPF top plate, a longer bearing length will be required due to the
lower compression perpendicular-to-grain design value for SPF.
4. The bearing lengths show the number of trimmers needed (e.g., 1.5 = 1 trimmer, 3.0 = 2 trimmers, etc.). This is based on the
maximum PLF loads. Shorter bearing lengths may be used with lighter loads.
5. Tables are based on simple span conditions using the actual span as the center-to-center of bearing.
6. The beam is assumed to be loaded on the top edge and supported at bearing points.
7. For floor deflection limits of L/240 and L/480, multiply the Maximum Live Load figure (Row 2) by 1.5 and 0.75, respectively.
For roof deflection limits of L/180 and L/360, multiply the Maximum Live Load figure (Row 2) by 1.333 and 0.667,
respectively. The result shall not exceed the Total Load Figure (Row 1).
8. A 9-1/2” depth member may be substituted for a 9-1/4” member, and an 11-7/8” for an 11-1/4”, etc.

Steps in Sizing Beams or Headers:


1. Determine the Total Load (live + dead) on the beam in PLF (pounds per lineal foot).
2. Determine the Live Load in PLF.
3. Find the actual span that is the same or greater than the span you have.
4. From the actual span row selected, find the PLF load that meets or exceeds the required PLF load for Total Load
(Row 1) and Live Load (Row 2). The required bearing length is given in Row 3.
5. The beam size is found at the top of the column of the selected cell that meets all of your conditions.
6. If the beam selected is too deep or the bearing length too long, continue in the selected row to find another.

(actual span)

Go to the allowable floor load table and find the 15’ actual span. Using the top
row, find a total load greater than 675 plf (3-1/2 x 14). Using the middle row,
find a live load greater than 540 plf (3-1/2 x 14). You must select the larger of
the two beams, or 3-1/2 x 14 and use 3.0” (2 trimmers) of bearing. You could
also use the 5-1/2 x 11-1/4 if you only had 3” (2 trimmers) of bearing.
1
For continuous joist (not simple span), multiply 1.25 times live and dead loads to correct
loading on Power Beam®.

15
Power Beam
76600_Anthony30F:Anthony30F 5/23/11 2:08 PM Page 17

Framing Connectors for Power Beam®


Power Beam ®

Top Mount Hangers Face Mount Hangers


Supported Member Supported Member Maximum Load Supported Member Supported Member Maximum Load
Hanger Hanger
Width Depth (lbs.) Width Depth (lbs.)
BA48 3800
3 - 1/2" 7 - 1/4" 3 - 1/2" 7 - 1/4" HHUS48 4210
WPU 3.56/7.25 4165
BA410 3800 HHUS410 5635
3 - 1/2" 9 - 1/4" 3-1/2" 9 - 1/4" - 9-1/2"
HB3.56/9.25 5650 HGUS410 9100
13.5/9.5 3800 HHUS410 5635
3 - 1/2" 9 - 1/2" 3-1/2" 11 - 1/4" - 11-7/8"
HB3.56/9.5 5650 HGUS412 9100
B3.56/11.25 2590 HHUS410 5635
3 - 1/2" 11 - 1/4" 3 - 1/2" 14" - 18"
HB3.56/11.25 5650 HGUS414 10100
13.56/11.88 3800
3 - 1/2" 11 - 7/8" 5-1/2" 7-1/4" HGUS5.50/8 7460
HB3.56/11.88 5650
BA3.56/14 3800 HHUS5.50/10 5635
3 - 1/2" 14" 5 - 1/2" 9 - 1/4" - 9-1/2"
GLTV3.514 7200 HGUS5.50/10 9100
BA3.56/16 3800 HHUS5.50/10 5635
3 - 1/2" 16" 5 - 1/2" 11 - 1/4" - 11-7/8"
GLTV3.516 7200 HGUS5.50/12 9600
HB3.56/18 5650 HHUS5.50/10 5635
3 - 1/2" 18" 5 - 1/2" 14"
HGLTV3.518 8835 HGUS5.50/14 10100
HGUS5.50/14 10100
5 - 1/2" 7 - 1/4" HB5.507.25 5650 5 - 1/2" 16" - 18"
HGU5.50-SDS 3 14145
HB5.50/9.25 5650 HHUS7.25/10 5635
5 - 1/2" 9 - 1/4" 7" 9 - 1/4" - 9-1/2"
GLTV5.50/9.25 7200 HGUS7.25/10 9100
HB5.50/9.5 5650 HHUS7.25/10 5635
5 - 1/2" 9 - 1/2" 7" 11 - 1/4" - 11-7/8"
GLTV5.59 7200 HGUS7.25/12 9600
HB5.50/11.25 5650 HGUS7.25/14 10100
5 - 1/2" 11 - 1/4" 7" 14"
GLTV5.50/11.25 7200
HGU7.25-SDS 3 14145
HB5.50/11.88 5650 HGUS7.25/14 10100
5 - 1/2" 11 - 7/8" 7" 16" - 18"
HGLTV5.511 8835
HHGU7.25-SDS 3 17845
HB5.50/14 5650
5 - 1/2" 14"
EGQ5.50-SDS3 3 19800 General Notes:
HGLT5.516 8835
5 - 1/2" 16" 1. Maximum loads shown are based on 3 - 1/2” minimum floor
EGQ5.50-SDS3 3 19800
loads at 100% duration. Consult Simpson’s Wood Construction
HGLTV5.518 8835
5 - 1/2" 18" Connectors catalog for allowable increases when other load
EGQ5.50-SDS3 3 19800
durations apply and for installation information. Hangers only
HB7.12/9.25 5650
7" 9 - 1/4"
GLTV49.25-2 7200 achieve Maximum load capacity when all nail holes are filled with
HB7.12/9.5 5650 the proper size nails and the minimum nail penetration. Full
7" 9 - 1/2"
GLTV49.5/2 7200 bearing is required at hanger seat. Hanger values listed are for dry
7" 11 - 1/4"
HB7.12/11.25 5250 service conditions only.
HGLTV411.25-2 8835
HB7.12/11.88 5650 2. Top flange hanger configuration and thickness of top flange need
7" 11 - 7/8"
EGQ7.25-SDS3 3
19800 to be considered for flush frame conditions.

7" 14"
HGLTV414-2 8835 3
When ordering EGQ, HGU, or HHGU specify height.
EGQ7.25-SDS3 3 19800
HGLTV416-2 8835
7" 16"
EGQ7.25-SDS3 3 19800
HGLTV418-2 8835
7" 18"
EGQ7.25-SDS3 3 19800

WPU HU HHGU GLTV


HGUS LBV HHUS
HB (HGLTV)
BA EGQ

16
Power Beam
Framing Connectors for Power Beam®
Power Beam
Top Mount Hangers
USP Fastener Schedule Allowable Loads (Lbs.)
Joist Size Uplift
Stock No. Header Joist 100%
160%
3-1/2 x 7-1/4 HBPH35725 (22) 16d (10) 16d 7000 2705
HBPH35925 (22) 16d (10) 16d 7000 2705
3-1/2 x 9-1/4
HLBH35925 (15) NA16D-RS (6) 16d 10620 1420
HBPH3595 (22) 16d (10) 16d 7000 2705
3-1/2 x 9-1/2
HLBH3595 (15) NA16D-RS (6) 16d 10620 1420
HBPH35112 (22) 16d (10) 16d 7000 2705
3-1/2 x 11-1/4
HLBH35112 (15) NA16D-RS (6) 16d 10620 1420
HBPH35118 (22) 16d (10) 16d 7000 2705 THDH Series
3-1/2 x 11-7/8
HLBH35118 (15) NA16D-RS (6) 16d 10620 1420 U.S. Pat. #5.217,317
HBPH3514 (22) 16d (10) 16d 7000 2705 Heavy Duty
3-1/2 x 14
HLBH3514 (15) NA16D-RS (6) 16d 10620 1420
Face Mount Hanger
HBPH3516 (22) 16d (10) 16d 7000 2705
3-1/2 x 16
HLBH3516 (15) NA16D-RS (6) 16d 10620 1420
HBPH3518 (22) 16d (10) 16d 7000 2705
3-1/2 x 18
HLBH3518 (15) NA16D-RS (6) 16d 10620 1420
5-1/2 x 7-1/4 HBPH55725 (22) 16d (10) 16d 6930 2705
HBPH55925 (22) 16d (10) 16d 6930 2705
5-1/2 x 9-1/4
HLBH55925 (15) NA16D-RS (6) 16d 10620 1605
HBPH5595 (22) 16d (10) 16d 6930 2705
5-1/2 x 9-1/2
HLBH5595 (15) NA16D-RS (6) 16d 10620 1605
HBPH55112 (22) 16d (10) 16d 6930 2705
5-1/2 x 11-1/4
HLBH55112 (15) NA16D-RS (6) 16d 10620 1605
HBPH55118 (22) 16d (10) 16d 6930 2705
5-1/2 x 11-7/8
HLBH55118 (15) NA16D-RS (6) 16d 10620 1605
HBPH5514 (22) 16d (10) 16d 6930 2705 HD Series THD Series
5-1/2 x 14
HLBH5514 (15) NA16D-RS (6) 16d 10620 1605
Heavy Duty Heavy Duty
HBPH5516 (22) 16d (10) 16d 6930 2705
5-1/2 x 16 Face Mount Hanger Face Mount Hanger
HLBH5516 (15) NA16D-RS (6) 16d 10620 1605
HBPH5518 (22) 16d (10) 16d 6930 2705
5-1/2 x 18
HLBH5518 (15) NA16D-RS (6) 16d 10620 1605
HBPH71925 (22) 16d (10) 16d 6930 2705
7 x 9-1/4
HLBH71925 (15) NA16D-RS (6) 16d 10620 1605
HBPH7195 (22) 16d (10) 16d 6930 2705
7x9
HLBH7195 (15) NA16D-RS (6) 16d 10620 1605
HBPH71112 (22) 16d (10) 16d 6930 2705
7 x 11-1/4
HLBH71112 (15) NA16D-RS (6) 16d 10620 1605
HBPH71118 (22) 16d (10) 16d 6930 2705
7 x 11-7/8
HLBH71118 (15) NA16D-RS (6) 16d 10620 1605
HBPH7114 (22) 16d (10) 16d 6930 2705
7 x 14
HLBH7114 (15) NA16D-RS (6) 16d 10620 1605
HBPH7116 (22) 16d (10) 16d 6930 2705
7 x 16
HLBH7116 (15) NA16D-RS (6) 16d 10620 1605 HBPH Series HLBH Series
HBPH7118 (22) 16d (10) 16d 6930 2705 Heavy Duty Heavy Duty
7 x 18
HLBH7118 (15) NA16D-RS (6) 16d 10620 1605
Top Mount Hanger Beam Hanger
Face Mount Hangers
Fastener Schedule Allowable Loads (Lbs.)
USP Notes for Top Mount Hangers:
Joist Size Uplift
Stock No. Header Joist 100% 125%
160% 1. Top flange hanger configuration and thickness of top
3-1/2 x 7-1/4
THD48 (28) 16d (16) 10d 4310 5005 2595 flange need to be considered for flush frame conditions.
THDH48 (36) 16d (10) 16d 7360 7835 3330
3-1/2 x 9-1/4 - 9-1/2
THD410 (38) 16d (20) 10d 5850 7045 3905 2. 10d nails are 0.148” diameter by 3” long and 16d nails are
THDH410 (46) 16d (12) 16d 9010 9010 4370
0.162” diameter by 3-1/2˝ long.
THD412 (48) 16d (20) 10d 7045 7045 3905
3-1/2 x 11-1/4 - 11-7/8
THDH412 (56) 16d (14) 16d 9845 9845 5225 3. NA16D-RS nails are 0.148˝ diameter by 3-1/2˝ long, hardened
THD414 (58) 16d (20) 10d 7045 7045 3905
3-1/2 x 14 - 18
THDH414 (66) 16d (16) 16d 12510 12510 6015
ring shank nails.
5-1/2 x 7-1/4 HD68 (14) 16d (6) 10d 1975 2470 1140
4. Uplift loads have been increased 60% for wind or seismic
THD610 (38) 16d (20) 10d 6535 7605 3410
5-1/2 x 9-1/4 - 9-1/2 loads; no further increase shall be permitted.
THDH610 (46) 16d (16) 16d 8990 8990 5400
THD612 (48) 16d (20) 10d 8255 8415 4255
5-1/2 x 11-1/4 - 11-7/8
THDH612 (56) 16d (20) 16d 10365 10365 5400
Notes for Face Mount Hangers:
THD614 (58) 16d (20) 10d 8415 8415 4255
5-1/2 x 14 - 18
THDH614 (66) 16d (22) 16d 12510 12510 6015 1. 10d nails are 0.148” diameter by 3” long and 16d nails are
THD7210 (38) 16d (20) 10d 6535 7605 3410 0.162” diameter by 3-1/2˝ long.
7 x 9-1/4 - 9-1/2
THDH7210 (46) 16d (12) 16d 8990 8990 4370
7 x 11-1/4 - 11-7/8 THDH7212 (56) 16d (14) 16d 8990 8990 5225 2. Uplift loads have been increased 60% for wind or seismic
7 x 14 - 18 THDH7214 (66) 16d (16) 16d 12510 12510 6015
loads; no further increase shall be permitted.
17
Power Beam
Connections for Two-Piece 3 1/ ” Wide
2
Connections for Two-Piece 3 /2" Wide Anthony
1 Power Beams
Power Beam Anthony Power Beam®
For Top-Loaded Applications
Minimum Connection Required:
Two rows of 1/2" Diameter Lag Screws(3) or Bolts (4) at 24"
on center staggered.
2"

For Side-Loaded Applications


24"

Maximum Uniform Load Applied to Either Side: 2"


12"

Two Rows Spaced At: 24" o.c. 12" o.c. Use either
all bolts or all lag
screws in any one
Lag Screws(3) 500 plf 1000 plf connection -- do not combine.

Bolts(4) 920 plf 1840 plf

Notes:
1. Verify adequacy of beam in uniform load tables.
2. Values listed are for 100% load duration. An increase of 15% for snow load roof applications or 25% for non-snow
roof conditions is allowed where permitted by the building code.
3. Lag screws are to be 1/2" diameter x 7" of material conforming to ASTM Standard A307 with a minimum bending
yield strength of 45,000 psi. A 3/8" lead hole is required for each lag screw. Turn lag screws tight with a wrench to
achieve full penetration. Do not hammer. A standard cut washer is required between the wood and screw head.
4. Bolts are to be of 1/2" diameter material conforming to ASTM Standard A307 with a minimum bending yield strength
of 45,000 psi. Bolt holes are to be the same diameter as the bolt, and located 2" from the top and bottom of the
member. A standard cut washer is required between the wood and bolt head and between the wood and nut.
5. Beams loaded from only one side must be restrained to minimize rotation.

typical connections

Foundation Beam Pocket Detail


When Uplift resistance is required by local building jurisdiction

Minimum 1/2” air space Untreated AFP Minimum 1/2” air space Untreated AFP
required at ends and sides Glulam Beam required at ends and sides Glulam Beam

Moisture break required:


1/4” treated plywood, steel
bearing plate, flashing, plastic
bearing plates, etc. Sized for
bearing of Glulam Beam
Foundation Wall

Moisture break required:


1/4” treated plywood, steel Use anchor of proper
bearing plate, flashing, plastic uplift capacity.
bearing plates, etc. Sized for (e.g. Simpson MTSM)
bearing of Glulam Beam Foundation Wall

18
18
Power Beam
Shear Design Equations for Notched
Power Beam and Tapered Beams

Compression side Compression side

d d

fv = 3V fv = 3V
2bd 2bd

(a) Square End Bearing (b) Slope End Bearing

3de or 1/3 of
3d the span,
maximum whichever is less
e
0.4d
Max.
d d
d/3 de de > 0.6d
Min.
3V
f v = 3V When e < d e , f v =
2bd e d-d
2b d- d e e
e

When e > d e , f v = 3V
(c) Sloped End Cut for Roof Drainage 2bd e

(d) Compression-side Notch

Bearing
Length

(f) Tension-side Notch

fv = shear stress (psi) V = shear force at notch location (lb) b = width of beam (in.)
d = depth of beam (in.) de = effective depth as shown (in.) e = length of notch as shown (in.)

Source: APA
Source: APA EWS S560
19
Power Beam
00_Anthony30F:Anthony30F 5/23/11
76600_Anthony30F:Anthony30F 2:09 PM
5/23/11 2:09Page
PM 21
Page 21

Guidelines for Drilling Vertical


¤

Power Beam and Horizontal Holes


¤

Guidelines for for


Guidelines Drilling Vertical
Drilling andand
Vertical Horizontal Holes
Horizontal Holes
VERTICAL
VERTICAL HOLES
HOLES
VERTICAL HOLES
Whenever possible, avoid drilling vertical holes through glulam beams. As a rule of thumb, vertical holes drilled through
Wheneverthe depthpossible,
possible,
Whenever of a drilling
avoid glulam beam
vertical
avoid drilling will
holes
vertical cause
through
holes a reduction
glulam
through beams.
glulam As in the
a rule
beams. Asofacapacity
thumb, at the
rule of vertical
thumb, location
holes drilled
vertical directly
holesthrough
drilled proportional
the depth
through theofdepth
a glulam to the
of a beam
glulam ratio
cause
beam of 1-1/2
a reduc-
cause a reduc-
times
tion in the the
tioncapacity
diameter
in the capacity
of
at the location the hole to
directly directly
at the location
the
proportional width of
to the ratio
proportional
the beam.
of ratio
to the 1-1/2 of
times For
1-1/2the
example
diameter
times
a one
of the hole
the diameter
inch
to the
of the
drilled
holewidth
hole
to theofwidth
in
the beam. a
of theFor
6-inch-wide
example
beam.
beam
a one inch
For example
would
driller
a one inch driller
reduce beam
in a 6-inch-wide the capacity of thecapacity
beamofatthe that section by approximately (1 x 1-1/2)
(1 x 1-1/2)
in a 6-inch-widewould
beamreduce
wouldthe
reduce the capacity beam
of theatbeam
that section
at that by approximately
section by approximately =25% =25%
6 6
For thisFor
For
this reason,
reason,
this when
reason,it when
whentoitdrill
is necessary is necessary
it is necessary vertical holesto drill avertical
through
to drill vertical
holes the
glulama member,
holes through
through
holes
glulam member,
a glulam
should
the holesbe
member,
positioned
should
the
in areas
be positioned
holes
of areas
in
should
the member be stressed
that are
of the member
positioned
to less in
that are stressed to less
areas of the member that are stressed to less than 50 percent of design in bending. In a simply supported, uniformly loaded
than 50 than
percent of designofindesign
bending. In a simply
50 percent in bending. In asupported, uniformaly
simply supported, loaded beam,
uniformaly loadedthis areathis
beam, would
areabewould
located from thefrom
be located end the
of the
endbeam
of theinward
beam approximately 1/8
inward approximately 1/8
beam,
of the beam
this area would be located from the end of thefrombeam inward approximately 1/8 ofedge
theof beam span. In all cases, the
of thespan.
beamInspan.
all cases,
In allthe minimum
cases, clear edge
the minimum distance,
clear as measured
edge distance, either
fromside of the
sidemember to the nearest the
edgevertical hole, should
hole,be 2-1/2be 2-1/2
minimum clear edge distance, as measured fromaseither
measured
side ofeither
the member of the member
to the tonearest
the nearest
edge ofofthe
the vertical
vertical should
hole, should
times the holethe
times diameter. Use a drill
Useguide
a drilltoguide
minimize “wandering” of the bit
of as it bit
passes
as itthrough knots orknots
material of varying density, density,
and to insure
and toa insure
true alignment
be 2-1/2hole diameter.
times the hole diameter. to minimize
Use a drill“wandering”
guide to the
minimize passes through
“wandering” ofor the
material
bit of
asvarying
it passes through knots a true alignment
or material
of the hole through
of the the depth
hole through of the
the depth beam.
of varying density, and oftothe beam. a true alignment of the hole through the depth of the beam.
insure

HORIZONTAL HOLES
HORIZONTAL
HORIZONTAL HOLESHOLES
Like notches, holes in a glulam beam remove wood fiber, thus reducing the net area of the beam at the hole location and
introducing
Like notches,
Like notches, a stress
holes inholes
glulam concentrations.
in a beam
glulamremove These
wood fiber,
beam remove woodthus effects
reducing
fiber, cause a reduction
the net the
thus reducing area of the
net areabeam in the
atbeam
of the capacity
the hole hole of
location
at the the
and beam
introducing
location instress
theconcentrations.
and introducing area of the These
penetration.
stress concentrations. These
For
effects cause this
effects reason,
a reduction
cause horizontal
in the
a reductioncapacity holes
of the
in the capacitybeam ininbeam
of the glued in laminated
the area of the
the of thetimbers
areapenetration. areFor
For this
penetration. limited
reason, in size
this horizontal
reason, and
holes location
inholes
horizontal tolaminated
gluedinlaminated
glued maintain are the
timbers timbers structural
limited
are in size in size
limited
integrity
and location oftothe
to maintain
and location thebeam.
maintain
Figure
structural
the structural
1integrity
integrity shows
of the zones
the beam.
of theFigure
of a 3uniformly
beam.3Figure
shows the zones
shows a loaded,
theofzones
uniformly simplysimply
loaded,
of a uniformly
supported
loaded,supported
beam where
beam where
simply supported beamthe
the field
fieldthe
where
drilling
drilling of holes ofof
field drilling holes
may be holes mayThese
considered. be considered.
non-critical
may be considered.
These
zones
These non-critical
non-critical
arezones
located in portions
are located
zones are
of the beam
in portions
located
of thestressed to in
lessportions
beam stressed than of50the
50 than
to less percent beam
of design
percent
stressed
ofbending stresstoand
design bending
less
lessthan
stress
50than
thanless
and 50 percent
percent of of of
50 percent
design
design shear bending
stress. stress
moreand lessloading
than 50 percent of design shear diagrams
stress. may
Forbebeams of more complex loading or other than
design shearFor beams
stress. Forofbeams complex
of more complex or other
loading orthan simple
other thanspans,
simplesimilar
spans, similar diagrams developed.
may be developed.
simple spans, similar diagrams may be developed.

1 = length
1 =oflength
beamof beam
d = depth
d =ofdepth
beamof beam

Figure 1
Field-drilled holes shoud
Field-drilled holesbeshoud
used be
for used
access
foronly andonly
access should
andnot be used
should as attachment
not be points for
used as attachment brackets
points or otherorload
for brackets bearing
other hardware
load bearing unless specifically
hardware designeddesigned
unless specifically
Field-drilled
as such by the engineer
as such
holes
by the engineer
should
or designer. be
Examples
or designer.
used for access
of accessofholes
Examples
only
include
access
and
those used
holes include
should
for used
those
not
the passage be used as attachment
wires, electrical
for the passage
points
conduit,conduit,
wires, electrical small diameter for brackets or
sprinklersprinkler
small diameter
other
pipes, fiber optic
pipes,
load
fiber optic
bearing
cables, and other hardware unless specifically designed as such byshould
the engineer or designer. Examples
of access holes include those
cables, andsmall,
otherlightweight materials.
small, lightweight These field
materials. drilled
These fieldhorozontal holes
drilled horozontal holesmeet themeet
should following guidelines:
the following guidelines:
used for the passage wires, electrical conduit, small diameter sprinkler pipes, fiber optic cables, and other small, lightweight
materials. These field drilled horizontal holes should meet the following guidelines:
1. Hole
1. size:
HoleThe hole
size: diameter
The should not
hole diameter exceed
should not 1-1/2
exceedinches
1-1/2or 1/10 the
inches beam
or 1/10 thedepth,
beamwhichever is smallest,
depth, whichever with thewith
is smallest, exception of 1-inch-diameter
the exception or smaller
of 1-inch-diameter or smaller
holes as1. Hole
noted
holes size:
asinnoted
Item The2hole
2 below.
in Item below.diameter should not exceed 1-1/2 inches or 1/10 the beam depth, whichever is smallest, with the
exception of 1-inch-diameter or smaller holes as noted in Item 2 below.
2. Hole 2.
2. Hole
Hole location:
location: The hole
location: The
The hole
should
hole should
have have ahave
a minimum
should a minimum
clear
minimum distance, clear
as measured
clear distance, distance,
from thefrom
as measured asthe
edge ofmeasured
the
edgehole from
to the
of the hole theof
nearest
to the edge ofthe
the beam,
nearest of the 4hole
ofbeam, to thediameters
holeofdiameters
4 hole nearest
to the to the

top end
top or bottom faceof the
or bottomof facebeam,
the beam andandand
8
of the beam 4 hole
hole 8 holediameters
diameters from the to the
end
diameters from theend
of top
the of or
beam.the bottom
Note that
beam. Note face
thethatof
thethe
horizontal beamhole
hole andshould
should
horizontal not8 hole
be not diameters
drilled in the from the end asofzone,
moment-critical
be drilled in the zone,
moment-critical theas
beam.
defined defined
in the figure Note
above, that
unlessthe horizontal
approved by an hole should
engineered or not
architect be drilled
qualified in in the
engineered moment-critical
timber design.
in the figure above, unless approved by an engineered or architect qualified in engineered timber design. zone, as defined in the figure above,
unless approved by an engineered or architect qualified in engineered timber design.

20
1 1
Figure 2
A 1-inch
A 1-inch diameter
diameter oror smaller
smallerhole
holemay
maybe becut
cutatatthe
themiddle
middlehalf
halfofofthe
the Beam depth, Span when
beam depth anywhere along the span, except for the area that is within 66
beam depth anywhere along the span, except for the area that is within d (in.) /d = 10
inches of
inches of clear
clear distance
distance between
between the
the face
face of
of the
the support
supportand andthe
thenearest
nearest
edge of the hole, providing the following conditions are met: 7-1/4 6’-1”
edge of the hole, providing the following conditions are met: 7-1/2 6’-3”
a. a.the
thebeam
beamisisatatleast
least7-1/4
7-1/4inches
inchesinindepth,
depth, 8-1/4 6’-11”
b. b.the beam is subject to uniform loads only,
the beam is subject to uniform loads only, 9 7’-6”
c. the span-to-depth ratio ( /d) is at least 10, 9-1/4 7’-9”
c. the span-to-depth ratio ( /d) is at least 10,
d. the hole spacing and maximum number of holes must meet the 9-1/2 7’-11”
d. the hole spacing and maximum number of holes must meet 9-5/8 8’-1”
requirements specified in Items 1 and 2 below, and
the requirements specified in Items 1 and 2 bellow, and 10-1/2 8’-9”
e. the hole must not be cut in cantilevers.
e. the hole must not be cut in cantilevers. 11 9’-2”
If the depth-to-span ratio of the beam is less than 10, the 1-inch diameter 11-1/4 9’-5”
If
ofthe depth-to-span
smaller hole may be ratio
cutofinthe beam is less
accordance than
with the10, the 1-inch
provisions diameter
listed 11-7/8 9’11”
of smaller hole may be cut in accordance with the provisions
above except that the location of the hole must maintain a clear distancelisted above 12 10’-0”
except
between that
thethe
facelocation of the hole
of the support andmust maintain
the nearest a clear
edge of thedistance
hole ofbetween
at least 12-3/8 10’-4”
the face of the
1/6 of the span. support and the nearest edge of the hole of at least 1/6 of the 13-1/2 11’-3”
span. 14 11’-8”
1. Hole Spacing: The minimum clear spacing between adjacent holes, 15 12’-6”
asHole
1. measured between
Spacing: The the nearestclear
minimum edgespacing
of the holes, should
between be 8 hole
adjacent holes, 15-1/8 12’-8”
diametersbetween
as measured based onthethe largestedge
nearest diameter
of the of any should
holes, adjacent
behole in the
8 hole diam- 16 13’-4”
etersbeam.
based on the largest diameter of any adjacent hole in the beam. 16-1/2 13’-9”
17-7/8 14’-11”
Number
2. 2. Number of of
holes: TheThe
holes: maximum
maximum number
number ofof
holes should
holes shouldnot
notexceed
exceed 18 15’-0”
1 hole per 5 feet of beam length. In other words, the maximum
1 hole per 5 feet of beam length. In other words, the maximum number of 19-1/4 16’-1”
number
holes shouldof holes
not should
exceed 4 fornot exceed 4 forbeam.
a 20-foot-long a 20-foot-long
The holebeam. The
spacing limita- 19-1/2 16’-3”
hole spacing limitation, as given above, should
tion, as given above, should be satisfied separately. be satisfied separately. 20 16’-8”
For glulam members that have been oversized, the guidelines given above 20-5/8 17’-3”
For glulam members that have been oversized, the guidelines give above 21 17’-6”
may be relaxed based on an engineering analysis.
may be relaxed based on an engineering analysis. 22 18’-4”
Regardless of the hole location, holes drilled horizontally through a 22-1/2 18’-9”
Regardless
member shouldof thebe
hole location,and
positioned holes drilled
sized withhorizontally through athat
the understanding mem- 23-38 19’-6”
ber should be positioned and sized with the understanding that
the beam will deflect over a period of time under in-service loading the beam 24 20’-0”
will deflect over
conditions. Thisadeflection
period of could
time under
causein-service
distress toloading conditions.
supported This
equipment
deflection could cause distress to
or piping unless properly considered.supported equipement or piping unless
property considered.

2
2121
Power Beam
76600_Anthony30F:Anthony30F 5/23/11 2:09 PM Page 23

Power Beam Dimensional Tolerances

Power Beam
Power Beam
Power Beam Glulam Appearance Grades
Surfaced to
Reduce Defects
Wane Void Surfaced to
Reduce Defects Voids Over
3/4” Filled

Glue Glue Squeeze Out


Voids Not Filled Removed
Squeeze Out
“Low Lamination”
Areas Filled or
“Low Lamination” Inlaid
“Low Lamination”
Areas Areas
Exposed Edges
Eased

22
Power Beam
Power Beam Power Beam® Handling & Storage

Anthony Power Beam® should be stored and handled in


accordance with the following guidelines to maximize
performance and to minimize necessary field adjustments.
n Protect the glulam products from direct exposure to n Do not install damaged glulam. Notify Anthony Forest
weather conditions (i.e. sun, wind, rain, snow) by storing Products Company or your local distributor for
under cover or by leaving the paper wrap intact until they assistance.

are installed in place.
n Once beams are installed, remove protective wrap.
n Store on stickers or racks above ground moisture and in Allow them to gradually season and adjust to the
orderly stacks at heights that may be handled safely. temperature and moisture conditions of the structure.
n Use care in moving and storing with forklifts to prevent n Do not directly expose glulam members to rapid
damage with forks. changes in moisture and temperature, typical of
temporary heating units. Such exposure may result in
n To minimize checking, seal ends of beams after trimming
excessive surface checking.
or cutting.

In the field glulam is subject to humidity and moisture


that can affect critical size tolerance and appearance.
To maintain the dimensional stability and minimize
checking of beams, each beam is surface sealed with a
special protective wax emulsion coating for wood.

Our sealers are environmentally friendly, water-based


products that help to stabilize the moisture content of
wood. Not only does the seal protect the glulams from
environmental moisture, but it allows the glulam to
adjust to the environment slowly.
Arkansas Laminating Plant

23
Power Beam
Power Beam Frequently Asked Questions

What is a Power Beam®?


Power Beam® is a high strength glulam produced to compete with LVL and Parallam®.
What is the warranty on Power Beam®?
Anthony Forest Products Company, LLC warrants that its Power Beam® will be free from defect in design, materials and
workmanship. When installed and finished according to installation instructions and accepted engineering standards, our
Power Products® will perform in accordance with our current published specification for the lifetime of your home or building.
How is it manufactured?
Power Beam® is manufactured using machine evaluated Southern Pine lumber in accordance with product standard ANSI A190.1-
2012 and ASTM D-3737. Materials are manufactured using wet use adhesives and are certified under APA-EWS quality control
and assurance program. Standard 28F and 30F Power Beam® are manufactured using balanced layups. These layups, designated as
28F-E2 and 30F-E2, are symmetric in their makeup, therefore no top or bottom orientation is required. An unbalanced layup for
Power Beam® is available. The unbalanced Power Beam®, designated as 28F-E1 and 30F-E1, has an asymmetrical layup with
stronger laminations in the tension zone than the compression zone. For this reason, unbalanced beams are marked with top
stamps and should be installed with the compression face upward.
Is Power Beam® cambered like most glulams?
Camber is often manufactured into glulams to offset the long term deflection due to gravity loads thus reducing the adverse
aesthetic effect of in-service deflections. The use of camber is advantageous for long span members supporting large design loads.
Typical residential and light commercial beam and header applications do not require camber. In fact, camber manufactured into
members used in these applications may never relax resulting in a permanent curvature. For this reason, standard 28F-E2 and
30F-E2 Power Beam® is manufactured with zero camber for use in simple, continuous, and cantilevered span applications.
Cambered Power Beam® will be produced in the 28F-E1 and 30F-E1 combinations.
Does it look like a typical glulam?
Power Beam® is a framing appearance grade glulam and is not intended for architectural applications. Power Beam® is side stamped
with Anthony Forest Products trademarks and APA-EWS quality marks.
How is Power Beam® packaged?
Power Beam® comes surface sealed, individually wrapped in water resistant paper or bundle wrapped.
What about storage?
As with any wood product, a well-drained covered storage site is preferred and recommended. Materials should be kept off of
the ground using blocking, skids, or rack systems. For long term storage, slits should be cut in the bottom of the wrapping to allow
ventilation and drainage of any entrapped moisture. Proper storage with adequate ventilation and drainage will reduce the
likelihood of staining, or other affects from water infiltration such as cupping and dimensional changes.
Can you notch or drill holes in Power Beam®?
Since glulams are highly engineered components manufactured from specifically selected and
positioned lumber laminations, an improperly cut notch or hole drilled in the wrong location
can significantly affect the member’s structural performance. For this reason, field modifications
such as notching, cutting, or drilling should be minimized and never done without a thorough
understanding of the effects on the member’s structural integrity. For further information on field
modifications see pages 19, 20 and 21 or contact Anthony Forest Products Company, LLC.

24
Power Beam
Engineered Timbers
Power Beam ...offer versatility, economy, strength and durability

Versatility can be combined with thermally efficient recommended for glulams. Please refer
Anthony glued laminated timber has a insulation materials to keep heat loss at a to APA EWS Y245B report “Calculating
proven track record of reliability for a minimum. Fire Resistance of Glulam Beams and
variety of structural applications. Exposed Strong, Durable, Fire Safe and Stable
Columns” for more information. Typically
beams offer a dramatic design element, Throughout history, wood has been a
an extra tension lamination is required. A
yet provide an unusual sense of softness, durable building material, assuming proper
design professional is required to ensure
natural charm, and inviting warmth. principles of design, construction and compliance with all local building codes.
At the same time, engineered timber maintenance are followed. The Anthony Readily Available
construction provides an exceptionally high Glulam provides an even higher degree of The Anthony Glulam is readily available
level of safety, durability and cost efficiency. proven quality manufacturing. through a network of stocking distributors
Kiln-dried Anthony Glulam offers a strong, Both the 2400F and 3000F Power Products® throughout the country. Glulams are offered
workable long span performance capability exhibit property characteristics superior in specified lengths up to 60’ in framing,
unmatched by any other building material. to solid sawn wood. Extra precautions are industrial, architectural and premium
grades. All beams are either bundled or
Cost Effective/Energy Efficient taken to ensure all laminations are kiln-
individually wrapped with water-resistant
Anthony Glulam is surprisingly economical dried to a maximum 15% moisture content.
paper. Beams are squared-end trimmed and
as compared to the higher cost composites The end product results in a beam member
manufactured with a standard 2000’ radius
or steel. The Glulam has a high strength to with an exceptional level of dimensional
camber or no-camber.
weight ratio and is sized to fit all system- stability, virtually eliminating checking,
type framing applications. One piece twisting, warping and shrinkage. Computer Software
construction reduces building time and Glulam, like large timbers, also has excellent All Power Products®, like the Anthony
cost, and the Glulam can be trimmed to fit natural fire resistant qualities. Although Power Beam®, can be sized for loading and
on the job site. considered a combustible material, glulam spans using our Power Sizer® sizing software
which is downloadable from our website.
The energy efficiency of engineered timber beams and columns may be designed
Please refer to the Power Sizer® software for
can provide additional savings to the for projects requiring a one-hour fire
sizes not shown in this brochure.
property owner. The natural thermal and resistance without the application of
insulating qualities of laminated wood fire retardant chemicals which is not

25
POWER PRODUCTS ®

family

Power Beam®
Power Joist®
Power Rated Glulam (PRG®)
Power Column®
Power Preserved Glulam®
Stock 24F Glulam
Power Pine®

2400F Glulam Power Joist® Treated Glulam Power Pine® Anthony Forest
MSR Lumber Span Calculator

26
DISTRIBUTED BY:

Power Column® Power Preserved Glulam® Power Pine® Power Joist® PRG®
309 N. Washington El Dorado, AR 71730 800-221-2326 www.anthonyforest.com
©
Anthony Forest Products Company, LLC - March 2016 Visit us online!