Professional Documents
Culture Documents
Contact Force Models Including Electric Contact de
Contact Force Models Including Electric Contact de
net/publication/228336560
CITATIONS READS
3 481
2 authors, including:
Ronald A. Coutu, Jr
Marquette University
145 PUBLICATIONS 1,175 CITATIONS
SEE PROFILE
All content following this page was uploaded by Ronald A. Coutu, Jr on 24 January 2014.
Signal line
tems (MEMS) switches depend on having adequate con-
Anchor
tact force to achieve desired, low contact resistance. Beam Width (75µm)
In this study, contact force equations that account for
beam tip deflection and electric contact material defor-
mation are derived. Tip deflection is modeled analyti- Beam Length (400µm)
cally using beam bending theory and contact material
deformation is modeled as elastic, plastic, or elastic-
plastic. Contact resistance predictions, based on Maxwellian
theory and newly derived contact force equations, are
Contact
Areas
compared to experimental results. Contact force pre-
dictions not considering tip deflection or material defor-
mation overestimate contact force and result in under- Figure 1: A captured video image of a 75 µm-wide by
estimated contact resistance. Predictions based on the 400 µm-long micro-switch.
new contact force models agree with measurements.
1 INTRODUCTION
a b
This paper reports on contact force models for elec- d
trostatically actuated, cantilever-style, radio frequency R2 = Fc
(RF), microelectromechanical systems (MEMS) metal
x=0 x=l
contact switches like that shown in Figure 1.
This new contact force modeling approach considers
beam tip deflection and electric contact material defor- Figure 2: Cantilever beam model with a fixed end at
mation that occurs after switch closure. Prior studies x = 0, a simply supported end at x = l, and an inter-
focused on mechanical designs to achieve the high con- mediately placed external load (Fa ) at x = a.
tact force needed for low contact resistance connections
[1]. The effects of tip deflection and material deforma-
tion on contact force in electrostatically actuated, micro- where Fc is contact force (µN ), Fa is applied electro-
switches has not been addressed. Previous work by this static force (µN ), a is the location of the applied elec-
author, showed that contact force, bounded by pull-in trostatic force (µm), and l is beam length (µm). This
and collapse voltages, could be analytically modeled us- simple model does not consider either beam tip deflec-
ing the beam illustrated in Figure 2 [2]. tion or contact material deformation after switch closure
Equation 1 is the resulting contact force equation [3]: or pull-in.
In this study, contact force equations are derived by
Fa 2 assuming elastic, plastic, and elastic-plastic electric con-
Fc = a (3l − a) (1)
2l3 tact material deformation [4] and modeling tip deflec-
∗∗ The views expressed in this article are those of the authors and tion [3]. Beam bending equations, material deformation
do not reflect the official policy or position of the United States models, and the principle of superposition are used to
Air Force, Department of Defense, or the U.S. Government. derive the new contact force equations.
a Fa a2 3EIz
R2 = [ 3
(3l − a)] − [ 3 (dc + α)] (5)
2l l
dc
where dc is the gap between the electric contacts
d
α (µm) and α is contact material vertical deformation
l
(µm). In micro-switches, the beam reaction force (R2 )
R2 = Fc
is equal to contact force and the external load is equal
x=0 x=l to electrostatic force. Substituting Fc for R2 , Equation
2 for Fa , and g = go − d, in Equation 5 results in:
Figure 3: Deflected cantilever beam model with a fixed
end at x = 0, a simply supported end at x = l, an o Asa V
2
3EIz
intermediately placed external load (Fa ) at x = a and Fc = [ a2 (3l − a)] − [ (dc + α)]. (6)
4l3 (go − d)2 l3
contact material deformation (α) at x = l.
3 MATERIAL DEFORMATION
The external load (Fa ), modeled as electrostatic force, Contact force is a compressive force that causes ma-
was found by neglecting fringing fields and using a first- terial deformation similar to that predicted by conven-
order parallel plate capacitor description: tional material tensile testing. The difference being ten-
2
sile loads cause material deformation by necking out
o Asa V and compressive loads cause deformation by bulging.
Fa = (2)
2g 2 Elastic, plastic, and elastic-plastic material deformation
F
where o is dielectric permittivity ( µm ), Asa is sur- models are discussed next.
2
face area (µm ) of one plate, V is applied voltage (V ),
and g is the gap (µm) under the beam.
3.1 Elastic
Like Figure 2, the beam in Figure 3 is statically inde- When electric contact surfaces initially come together,
terminate and another equation is needed to supplement
they experience elastic or reversible material deforma-
the static
equilibrium equations (i.e. Fx = 0, Fy = tion. Equations 7 and 8 define the contact area and
0, and M = 0). Using superposition, tip deflection force as a function of vertical deformation [4]:
is represented by the sum of two statically determinate
systems. The first is a beam with a fixed end, a free end, A = πRα (7)
and an intermediate load (Fa ) and the second is a beam 2
where A is contact area (µm ), R is radius of curvature
with a fixed end, a free end, and an end load (−R2 ).
(µm), and α is vertical deformation (µm) and
Using the method of moments, Equation 3 results
for the maximum tip deflection for the first statically 4 √
determinate system (beam with intermediate load) [3]: Fc = E α Rα (8)
3
Fa a2 where Fc is contact force (µN ) and E is Hertzian mod-
d= (3l − a) (3) ulus (GP a) defined by:
6EIz
where d is maximum cantilever beam tip deflection 1 1 − ν12 1 − ν22
(µm), E is elastic modulus (GP a), and Iz is the area
= + (9)
E E1 E2