Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Mechatronic

Pressure Measurement

Bourdon Tube Pressure Gauges with Switch Contacts


Plastic Case
Model PGS10
WIKA Data Sheet PV 20.01

Applications

 Pressure gauge for indicating and monitoring the


pressure in tanks and for signalling leaks
 General industrial applications

Special Features

 High switching reliability and long service life


 Design per EN 837-1
 Pressure indication over 270 angular degrees
 Adjustable contact between 10 and 90 % of the
scale range

switchGAUGE Model PGS10

Description

Design Operating temperature


per EN 837-1 Ambient: -40 ... +60 °C
Medium: +60 °C maximum
Nominal size in mm
50 Temperature effect
When temperature of the measuring system deviates from
Accuracy class reference temperature (+20 °C):
2.5 max. ±0.4 %/10 K of the span

Switch point tolerance Process connection


+/- 4 % Cu-alloy, male thread
Lower mount (LM) or centre back mount (CBM)
Scale ranges
Pressure element
0 ... 0.6 to 0 ... 400 bar
Cu-alloy
or all other equivalent vacuum or combined pressure and
≤ 60 bar: C-type
vacuum ranges
> 60 bar: helical type
Pressure limitation Movement
Steady: 3/4 x full scale value Cu-alloy
Fluctuating: 2/3 x full scale value
Short time: full scale value Dial
Aluminium, white

WIKA Data Sheet PV 20.01 ∙ 08/2009 Page 1 of 2

Data Sheets showing similar devices:


switchGAUGE, Stainless Steel Case; Model PGS11; see data sheet PV 21.01
switchGAUGE, Stainless Steel Case; Model PGS21; see data sheet PV 21.02
Pointer Options
Plastic, black
 Other process connection
Case  Nominal size 40 (on request)
Plastic  All-plastic design
 Switch point tolerance +/- 2.5 %
Window  Accuracy class 1.6 (Model PGS11/21)
Polycarbonate  Stainless steel case (Model PGS11/21)
 Approval per EN 12094-10 (Model PGS11/21)
Ingress protection
IP 44 per EN 60 529 / lEC 529
Dimensions in mm
Helium leakage test Standard version
Leak rate 10-5 mbar*l/s
Lower mount (LM)
Electrical data
Switching voltage: 4.5 ... 24 VDC/VAC
Switching current: 5 ... 100 mA
Contact load: max. 2.4 W
Switching contact: breaks (NC - normally closed) or
makes (NO - normally open)
Contact adjustment: adjustable between 10 and 90 %
of the scale range
Potential-free

11475707.02
Electrical connection
Flying leads

Centre back mount (CBM)

11475669.02
NS Connection Dimensions in mm Weight in kg
location D a b1 ± 0.5 b2 ± 1 h±1 G SW
50 lower mount (LM) 49 10 32 - 47 G 1/4 B 14 0.10
50 centre back mount (CBM) 49 - 34 54 - G 1/4 B 14 0.10

Process connection per EN 837-1 / 7.3

Ordering information
Model / Nominal size / Scale range / Connection size / Connection location / Switch point and function / Options

Modifications may take place and materials specified may be replaced by others without prior notice.
Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing.

Page 2 of 2 WIKA Data Sheet PV 20.01 ∙ 08/2009


08/2009 GB

WIKA Alexander Wiegand SE & Co. KG


Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel. (+49) 9372/132-0
Fax (+49) 9372/132-406
E-mail info@wika.de
www.wika.de

You might also like