Contents
2. Model Description
Programmable
Logic Controller
Model: SMC-H40MR
Power:100-240V~50/60Hz 12.7W
P/N:1605261053011810012
SAVCH ELECTRIC CO.,LTD.
S M C - H 40 M R D - e
Product name Ethernet port
e: Built-in Ethernet port
Product Series
Power supply
H: High performance PLC MPU
D: 24V DC
M: Motion control PLC MPU
Output type
I/O point R: Relay
Built-IO:10-point,16-point,24-point, T: Transistor
32-point,
48-point,40-point,60-point are optional. Module type
M: Main
E: Extension module
Size A
0 1 2 3 4 5 6 7
DI(X)
35.0
95.0
PWR
RUN
SMC-H16MR
COM
ERR
DO(Y)
0 1 2 3 4 5 6 7
3.0
84.4
82.0 93.0
Size B Size C
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
8 9 10 11 8 9 10 11 12 13 14 15
DI(X) 16 17 18 19
DI(X)
168.7
177.0
4. Indicator Description
① PWR: Power indicator,green. Continuous ON - Power good; OFF - Power error.
② RUN: Running indicator,green. Continuous ON - PLC is in running state; OFF - PLC was shutdown.
③ COM: Communication indicator,green. Flickering - PLC is in communicating state, the flicker frequency
indicates the speed of the communication; OFF - No communication.
④ ERR: Error indicator .double (red. yellow), as follows
2
Consult manage Signify information type ERR the state of the indicator
Normal Without error Not light
Normal,just prompt take PLC have the component which Yellow flicker: On 0.2 seconds and
attention to the locked data locked Off 0.8 seconds
Problem in the soft setting ,permit
Modificate the PLC hardward Yellow flicker: On 0.2 seconds and
user keep on operate the user
configure Off 0.8 seconds
program
Check module parallel bus Communication abnormal between
(check the RTC battery; modules, auto dislodge the Yellow flicker: On 0.8 seconds and
check extension module abnormal module, permit user keep Off 0.2 seconds
power supply) on operate the user program
Fireware abnormal or user program
Upgrade the fireware or Red slowly flicker:indicator light
abnormal,can not operate the user
modify the user program 0.5s not light 0.5s
program
Hardware error,user program con
Maintain red constant light
not running
3
Item Environment Specification
4
NPN Internal power NPN External power
5
OUT PUT +24V OUT- X0 X1 X2 X3 GND A+ B- RS485 OUT PUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 GND A+ B- RS485
Max 200mA S/S X4 X5 X6 X7 Max 200mA S/S X8 X9 X10 X11 X12 X13 X14 X15
SMC-H16MR/T(-e) SMC-M16MT(-e) SMC-H32MR/T(-e)
AC L N Y2 Y3 C4 Y6 Y7 L N Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15
AC
IN C0 Y0 Y1 Y4 Y5 C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13
IN
OUT PUT +24V OUT- X0 X1 X2 X3 GND A+ B- RS485 OUT PUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 GND A+ B- RS485
Max 200mA S/S X4 X5 X6 X7 X8 X9 X10 X11 Max 200mA S/S X8 X9 X10 X11 X12 X13 X14 X15 X16 X17 X18 X19
SMC-H24MR/T(-e) SMC-M24MT(-e) SMC-H40MR/T(-e) SMC-M40MT(-e)
AC L N Y2 Y3 C4 Y6 Y7 Y10 Y11 AC L N Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15 Y18 Y19
IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13 C16 Y16 Y17
OUTPUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 X17
Max 200mA S/S X18 X19 X20 X21 X22 X23 X24 X25 X26 X27 X28 X29 X30 X31 X32 X33 X34 X35
SMC-H60MR/T(-e) SMC-M60MT(-e)
AC L N Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15 Y18 Y19 C20 Y22 Y23 GND RS485
IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13 C16 Y16 Y17 Y20 Y21 A+ B-
OUT PUT +24V OUT- X0 X1 X2 X3 GND A+ B- RS485 OUT PUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 GND A+ B- RS485
Max 200mA S/S X4 X5 X6 X7 Max 200mA S/S X8 X9 X10 x11 X12 X13 X14 X15
SMC-H16MRD/TD(-e) SMC-M16MTD(-e) SMC-H32MRD/TD(-e)
DC + 24V IN - Y2 Y3 C4 Y6 Y7 DC + 24V IN - Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15
IN C0 Y0 Y1 Y4 Y5 IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13
OUT PUT +24V OUT- X0 X1 X2 X3 GND A+ B- RS485 OUT PUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 GND A+ B- RS485
Max 200mA S/S X4 X5 X6 X7 X8 X9 X10 X11 Max 200mA S/S X8 X9 X10 X11 X12 X13 X14 X15 X16 X17 X18 X19
SMC-H24MRD/TD(-e) SMC-M24MTD(-e) SMC-H40MRD/TD(-e) SMC-M40MTD(-e)
DC + 24V IN - Y2 Y3 C4 Y6 Y7 Y10 Y11 DC + 24V IN - Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15 Y18 Y19
IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13 C16 Y16 Y17
OUTPUT +24V OUT- X0 X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 X16 X17
Max 200mA S/S X18 X19 X20 X21 X22 X23 X24 X25 X26 X27 X28 X29 X30 X31 X32 X33 X34 X35
SMC-H60MRD/TD(-e) SMC-M60MTD(-e)
DC + 24V IN - Y2 Y3 C4 Y6 Y7 Y10 Y11 C12 Y14 Y15 Y18 Y19 C20 Y22 Y23 GND RS485
IN C0 Y0 Y1 Y4 Y5 C8 Y8 Y9 Y12 Y13 C16 Y16 Y17 Y20 Y21 A+ B-
Computer side (RS-232) DB9 female PLC side (COM1) 4 core S terminal male
7
■ Innovate for more | win forever
■ Industry intelligence | Energy saving | Green power
Savch wechat
Service Number
Quanzhou Factory
Address:3# Zixin Road, Jiangnan Hi-Tech Industrial Park, Sales service contact address
Quanzhou, Fujian, China
Tel:0595-24678267 Fax:0595-24678203
Service Network
Website:www.savch.net
Qualification
Received ISO9001 and CE recognition