Connection Number :
Node Number :

Inputs
H = 450 mm
B = 200.0 mm
tf = 19.00 mm
tw = 9 mm
Beff = 330 mm
Fyb = 345 Mpa
D = 406 mm
t = 19 mm
Fyc = 345 Mpa
Cross Section area, A = 23100 mm 2
Fx = 1000 kN
My = 100 kN.m

Check for the actual load at flanges

Fmax = (IFxI/2) + (IMy1I / H - tf)


= 732.0 Mpa

Allowable, Na = [σeok x t2 x (4.2 + 21.3 x ẞ2)] x f(n)


f(n) = 1.0
ẞ, Beff/D
= 0.81

Document No.XXXXXX Page No.1 of 2


Flange Punching

Design value for yield stress of column, σeok = Ɣ x s x Fyb Ɣ = 1.0 for operating
= 207.0 Mpa s = 0.6

Na, = 1365.4 kN

Unity Check, UC = Fmax/Na


0.54 < = 1, OK

Check for 50% capacity of flange

F1/2cap = 0.5 x (0.6 x Fyb) x B x tf


= 393.30 kN

Unity Check, UC = F1/2cap/Na


= 0.29 < = 1, OK