Chapter contents Syphonic rainwater drainage 7

Roof drainage       Syphonic rainwater drainage   

Cast iron (EN-GJL‑200)


Cast iron flat Consists of an iron-carbon alloy in which the carbon is bonded in the metallic base in
roof drains an lamellar fashion. This so-called graphite grid gives cast iron excellent resistance to
corrosion and is thus perfect for use in waste water engineering.

Stainless steel (material grade 304)


Stainless steel flat refers to especially highly-pure alloyed or non-alloyed steels. Suitable for a range of
roof drains uses, steel is resistant to water, steam and humidity. Typical areas of use include roof
drainage for large factory buildings.

Informations
Decision diagram . . . . . . . . . . . . . . 288
Basics . . . . . . . . . . . . . . . . . . . . . . 289

287
K9/1
Vacuum drains
7 Planning references
Roof drain   Vacuum drain  

Decision diagram - vacuum drain

Basic requirements

Vacuum drainage Open channel drainage

■■ Large roof areas, ■■ Small roof areas,


per drain ≥ 150 m2 per drain < 150 m2
■■ Sufficient difference in ■■ Lots of space
height of 4.2 m between ■■ Short collecting line
the roof and the under-
ground pipes
■■ In limited installation situa-
tions below the ceiling (no
drop installation possible)
■■ In long collecting line

Influencing factors

■■ Local rain event


■■ Underground pipe connection
■■ Arrangement of pipe installation
■■ Roof structure
■■ Height level

Dimensioning

DIN 1986-100 EN 12056


Drainage systems for build- DIN 1986-100
ings and properties Gravity drainage
systems inside
buildings

Material selection

Stainless steel or cast iron jet Stainless steel or cast iron


drains Spin drains

GM-X drain pipe


GM-X composite pipe

288
K9/1
Vacuum drains

Roof drain   Vacuum drain  


Planning references 7
Basics
The vacuum drain works with special ■■ the possibility is available that the overall system. The volume flow, which
flat roof drains, which are operated with individual drains, which are connected must be discharged over the pipe system
routinely filled pipes in contrast to the to a downpipe, can be coordinated based on the dimensioning rain, is the
open channel drainage (degree of filling hydraulically. calculation principle. A relevant hydraulic
h/d 1.0). In order to achieve this, it must ■■ a starting height (distance between calculation can be verified with the aid of
include whirling in air into rain water the inlet level up to the centre of the a programme.
(suctioning in air) must be stopped when installation line) of at least 0.3 - 0.4 m
entering into the pipe. This is achieved by is available. Planning service:
using special functional parts in the ACO ■■ the distance between two drains equals
flat roof drains Jet. As soon as the meas- no more than 20 meters. ■■ Calculation of the number and location
uring rainfall necessary for the operation of roof drains
is achieved, the system will operate with The functionality of pressure drainage ■■ Hydraulic calculation of the roof drain-
completely filled pipes in the pressure flow pipes is only available above the backflow ing system
range, whereby the connected roof area level. Rainwater pipes located underneath ■■ Determination of strand geometry with
will be quickly and safely drained. The roof must be dimensioned as open channel details for the nominal width of the
drain can be operated with a pressure lines. required pipes and fittings; Isometric
powered flow, if Drainage in the open channel system is drawing of the piping systems
■■ a sufficient height difference of at least more advantageous for the drainage of ■■ Hydraulic calculation verification
four meters is available between the traffic and walk-in areas (such as parking ■■ Material lists
roof and the underground pipe. decks or terraces with public traffic) due ■■ System check after completed as-
■■ large roof areas have to be drained, to the pollution risk, since small pipe sembly
whereby the a draining capacity of at diameters become clogged more quickly
least 1.0 l/s must be removed per than large ones. A vacuum drain calcula-
drain. tion is required for the safe function of the

289
K9/1
Vacuum drains
7 Planning references
Roof drain   Vacuum drain  

Planning references
The roof cover is the ultimate limit of a interior pipes. The increase in damages, especially on
building. Due to the high demands on Drains without odour seals with compres- flat roofs of light construction, due to
these ceilings by rainfall, fluctuating cli- sion-sealing flanges are used in these heavy rainfalls occurring more frequently,
matic conditions and varied traffic loads, areas. The roof drains must be arranged makes the engineering design and calcula-
the seal in the roof structure receives so that the rain water is drained quickly. tion of the emergency drainage on flat
special importance regarding its physical roofs a must.
construction. Distance between the drains: According to DIN 1986-100, the emer-
■■ Max. 20 m for flat roof drains gency drain may not be connected to the
ACO has developed flat roof drains for the ■■ Max. 10 m for channel drains drainage system, but must be drained by
functional drainage of rainwater and the a free outlet to property areas that can be
secure connection of the seal. The current ACO provides a modular system for flooded without causing damage.
version of EN 12056-3 in conjunction this, consisting of drains of the nominal The utilization must be checked for veg-
with DIN 1986-100 must be observed for widths DN 40, DN 50, DN 70, DN 80 and etated roof areas and inverse roofs (water
planning. DN 100, in 1 or 2-part version as well as volumes).
in stainless steel and cast iron. In addi-
Roof drains are installed to drain rain tion, accessories are offered for the most
water that accumulates on roof areas. diverse flat roof structures.
They absorb rain water and drain it over

Roof structures
Solid construction Lightweight construction

This type of roof construction, for Flat roofs of this construction are gener-
example, of prestressed concrete or fer- ally unsuitable for rainwater storage or
roconcrete are generally suitable for rain retention. They are mainly used in com-
water storage or retention. The resulting mercial buildings, for example, as a trap-
loads must be calculated in dimensioning ezoidal sheet metal structures provided on
the structure by the structural engineers. light frames.
Relevant information about the desired The additional rain water load at an
water over-fill must be provided to the increased backflow would create a burden
planner in time. that would even surpass snow loads.

Roof construction
The top floor ceiling is generally the best Flat roofs are designed as warm roof (non- The waterproof roof seal of the flat roof
part of the roof structure in flat roofs in ventilated roof), as cold roof (ventilated takes over the protection from penetrat-
multi-story buildings. Usually these are roof) or also as an inverted roof with ex- ing water. Typical materials for sealing
solid ferroconcrete sheets, fitted sheet ternal insulation. Roofs without insulation, flat roofs are bitumen - welding beads
metal or reinforced concrete structures. such as parking decks and terraces, and (now generally polymer modified) and
other roof areas above unheated spaces plastic roof sheeting.
Flat roofs are roofs that generally only are a special form.
have a low pitch.

Roof structure with


a sealing membrane

ACO flat roof/terrace drains have a mould-


ed compression-sealing flange. The drain
body is built into the flat roof or roof terrace
ceiling, whereby the compression-sealing
flange is slightly recessed in the ceiling.

290
K9/1
Vacuum drains

Roof drain   Vacuum drain  


Planning references 7
Roof structure with two
sealing membranes

If a second sealing level is required, a


cast iron drain body can be expanded
with an additional upper part, which has a
moulded compression-sealing flange. The
top section is cut to length according to
the insulation thickness and inserted in
the drain body and is sealed with a sealing
ring against water backflow.

For stainless steel, this drain is sup- ACO also provides specifically matched bed, stilted panels, green roof and gravel
plemented by a bottom part, into which accessories for the various roof types, covered roof.
the vapour barrier is pressed in. The top such as non-ventilated roof, inverted roof,
sealing membrane must be pressed into multi-storey car park, plates in gravel
the drain.

Drain types
Two drain types are used for the safe The 1-piece drains are used for roofs EN 12056-3 and the current
drainage of rain water and the safe con- without insulation and inverted roofs. DIN 1986-100 must be observed when
nection of the sealing membranes: The 2-part drains are used on non-ventilat- planning flat roof drains.
■■ Flat roof, terrace, parking deck drains ed roofs. The compression-sealing flange The drains of the Jet series are used for
1-piece with a compression-sealing of the drain body/lower part is used for the vacuum drainage. The connecting lines
flange including the vapour barrier. The sealing must be designed according to
■■ Flat roof, terrace, parking deck drains membrane is securely connected to the DIN 1986-100.
2-piece with a compression-sealing compression-sealing flange of the upper
flange each flange section.

Selection criteria for roof drains


Roof drains channel the rain water from Rain water volume   N ominal Traffic load 
roof surfaces into the drainage lines harm- width classification
less to humans and harmless to buildings. The drainage value of the roof drains is in The traffic areas are classified according
They should be provided wherever rain wa- direct conjunction with the nominal width to DIN 1253. In accordance, there are
ter can accumulate on the roof and must of the roof drain. Depending on the ac- load classifications H 1,5, K 3, L 15 and
be safely drained. They must be installed cumulating rain water volume, the nominal M 125. Depending on the traffic area, the
where demanded by DIN 1986-100. width DN 40, DN 50, DN 70, DN 80 or DN correspondingly classified drain/grating
100 must be selected and the number of must be selected.
roof drains must be defined.
Fire behaviour
Pipe distortion  Cast iron and stainless steel roof drains
socket inclination correspond with building material class A1
The connecting line is distorted in or according to DIN 4102. These drainage
under the ceiling depending on the struc- systems do not burn. These are ideal
tural conditions. Accordingly, a roof drain conditions for preventive structural fire
with a socket inclination of 1.5° or 90° is protection.
selected.

291
K9/1
Section contents Cast iron flat roof drains 7

Roof drainage       Syphonic rainwater drainage       Cast iron

Syphonic rainwater drainage


Page
Basics 294
Flat roof drains 298

Drain body DN 50 Components 299

Cast iron
Accessories 300
Flat roof drains Jet
Flat roof drains 302

Drain body DN 80 Components 303

Accessories 304

293
K9/1
Vacuum drain (cast iron)
7 Planning references
Roof drain   Vacuum drain   Cast iron

Vacuum drain of cast iron

Cast iron material


Grey cast iron with lamellar graphite of safety in relation to fire protection basically possible to waive any surface
(EN-GJL-200) is an ideal construction for building drainage at a melting point coating for corrosion protection.
material with a good basic performance of about 1,100 ° C. Roof drains Wal-
and many uses. Cast iron according to Selecta are made of cast iron, material
EN 1561 designates a ferrous alloy with a EN-GJL-200. Based on the layered deposit
high content of carbon, silicon and other of carbon in the metal base, cast iron re-
components, such as manganese, chrome ceives an excellent corrosion resistance.
or nickel. Cast iron offers a high degree This so-called graphite grating makes it

Single part drain body with compression-sealing flange

A compression-sealing flange consists of


Vacuum drain

■■ A non-rotatable flange
Cast iron

Flange which is solidly connected to the


drain body.
■■ A rotatable flange
Flange with which the seal is pressed
against the non-rotatable flange to cre-
ate a tight connection.

Two-part drain body with compression-sealing flange

Installation in insulated roofs

■■ Drain body
Compression-sealing flange to connect
with the vapour barrier.
■■ Top section
with compression-sealing flange to con-
nect with the sealing membrane above
the insulation.
■■ Sealing ring standard, prevents the
penetration of waste water backflow
from the downpipe into the insulation
and also the water drainage of the seal-
ing membrane into the drain body.

294
K9/1
Vacuum drain (cast iron)

Roof drain   Vacuum drain   Cast iron


Planning references 7
Insulating body and rings for flat roof drains Jet DN 50/DN 80

■■ Moulded parts of vapour diffusion-tight


foam glass (FOAM GLASS) for the heat
insulation of the drain body, i.e. the
upper part.
■■ The condensation development in the
drain area is thereby prevented.
■■ The moulded parts can be used as
lost shuttering when concreting the roof
ceiling .
■■ The insulating rings and bodies are of
non-combustible foam glass, building
material class A1, according to
DIN 4102.
■■ Foam glass is non-combustible and
does not contribute to the further develop-
ment of fire.
■■ Foam glass corresponds with building

Vacuum drain
materialsclass A1, according to

Cast iron
EN 13501-1.

Flat roof heater


ACO optionally offers a heater for roof cially in houses in an extreme location, In order to prevent unnecessary energy
drains to prevent freezing of the drain. when connected to separate sewage consumption, it is advisable to regulate
This not only increases the functional system, for buildings that are not heated the heated roof drains via an additional
reliability of the drainage system even at at times during the winter months, drains thermostat.
subzero temperatures, but is also recom- that are located in shady areas, etc. The
mended by DIN 1986-100. requirements of the VDE and the local EVU
A flat roof heater is recommended espe- regulations must be observed.

295
K9/1
Vacuum drain (cast iron)
7 Planning references
Roof drain   Vacuum drain   Cast iron

Cast iron vacuum drain DN 50

Top frame with grating Gravel trap

L15 M125

Top ring

Loose flange
Height-adjustment
Vacuum drain
Cast iron

Top section

Pitot tube

Sealing ring

Insulating ring

Compensation
element

Function elements

Loose flange

Drain body

Flat roof
heater

Insulating body

296
K9/1
Vacuum drain (cast iron)

Roof drain   Vacuum drain   Cast iron


Planning references 7
Cast iron vacuum drain DN 80
Gravel trap Top frame with grating Gravel trap

not screwed on screwed on

Height Height-adjustment
adjustment

Pitot tube Top ring Pitot tube

Loose flange

Vacuum drain
Cast iron
Top section

Sealing ring

Insulating ring

Compensation
element

Function elements

Loose flange

Drain body

Flat roof
heater

Insulating body

297
K9/1
Flat roof drains Jet
7 Drain body DN 50
Roof drainage   Syphonic rainwater drainage   Cast iron

Flat roof drains Jet syphonic rainwater drainage

Product information
■■ Drain body DN 50 ■■ With compression-sealing flange
■■ Coated cast iron ■■ With seepage openings
■■ Building material class A1 ■■ With function element
■■ Certified in accordance with DIN 1253

Ordering information
Core hole dimension

Nominal Øa Øc b Article No.


Selection assistant

Øa
size [mm] [mm] [mm]
Syphonic rainwater drainage

b
For drain body without isolating body

DN 50 300 150 30 7037.10.10

For drain body with isolating body


Cast iron

DN 50 315 220 45 7037.10.10 Øc

Nominal Socket incli- Outflow Recess Weight Article No.


width nation value
[l/s] [mm] [kg]
Ø290
Ø141

DN 50 90° 9,0 230 x 320 5,0 7037.10.10


195

76

298
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Cast iron


Drain body DN 50 7
Components

Drain bodies upper part DN 50

Ordering information

Designation compatible with Description Article No.


Ø290
Ø150 ■■ Coated cast iron
Ø142
■■ With compression-
sealing flange in accor-
dance with EN 1253
70

■■ Flat roof drains Jet ■■ Non-flammable in ac-


††DN 50 cordance with building
Upper part 7047.10.25
■■ Flat roof drains Spin materials class A1
250

††DN 70 ■■ With seepage openings

Syphonic rainwater drainage


and lip-seal
■■ Height-adjustability:
62 – 200 mm
■■ Weight: 8.0 kg
DN100

Cast iron
Top sections and gratings

Ordering information

Designation compatible with Description Article No.


□200
45

■■ Cast iron
■■ Cast iron Jet flat roof
10

Top frame with grating ■■ Load class: M 125 7000.44.00


drains DN 50
■■ Weight: 5.0 kg

□200
45

■■ Cast iron
■■ Cast iron Jet flat roof
10

Top frame with grating ■■ Load class: L 15 7000.43.00


drains DN 50
■■ Weight: 4.0 kg

Ø287 ■■ Flat roof drains Jet


■■ Stainless steel
††DN 50
Shingle filter ■■ With 2 mounting screws 7000.02.00
15

■■ Flat roof drains Spin


■■ Weight: 1.2 kg
75

††DN 70

299
K9/1
Flat roof drains Jet
7 Drain body DN 50
Roof drainage   Syphonic rainwater drainage   Cast iron

Accessories

Designation compatible with Description Article No.


■■ Flat roof drains Jet
††DN 50
■■ Upper part for flat roof drains
Spin
††DN 70
Ø136 ■■ 1-/2 piece flat roof/terra-
ce drains Spin DN 70 for
Lip seal ring ■■ Diameter: 136 mm 7047.00.26
customer-side provision of a
11

ventilation pipe
††Cast iron SML pipe DN 100
for grey water downpipe
over roofs, length accor-
ding to DIN 12056 and
DIN 1986‑100
Syphonic rainwater drainage

40
80

Ø145
Cast iron

■■ Cast iron flat roof drains Spin


††Socket inclination: 90°
††DN 70 ■■ Foam glass
Insulating body 7040.22.00
■■ Cast iron flat roof drains Jet ■■ Weight: 0.75 kg
††Socket inclination: 90°
††DN 50
270
316
290

Ø110
■■ For upgrade of the drain
body DN 50 to an emergency
■■ Flat roof drains Jet overflow
Pilot tube 7047.10.55
55

††DN 50 ■■ With lip seal ring


■■ For 1-/2piece design
■■ Weight: 0.1 kg

■■ Mains supply: 220 – 240 V AC


■■ Nominal performance: 25 W
■■ Protection rating: I
■■ Protection type: IP X7
■■ All flat roof drains are made of
■■ Connection conduit:
Flat roof heating cast iron 7000.85.00
††SIHF 3 x 1 mm²
††DN 50 – DN 150
††Length: 1.5 m
■■ Certified in accordance with DIN
VDE 0700, parts 1 and 223
■■ Weight: 0.5 kg
□300 ■■ Flat roof drain upper part Spin
††DN 70 ■■ Foam glass
Insulating ring 7040.12.00
■■ Flat roof drain upper part Jet ■■ Weight: 0.7 kg
60

††DN 50
□300
Ø145 ■■ Flat roof drain upper part Spin
Compensation ††DN 70 ■■ Foam glass
50

7040.02.00
element ■■ Flat roof drain upper part Jet ■■ Weight: 0.7 kg
††DN 50

■■ Stainless steel
Ø285
■■ With 2 mounting screws
■■ Shingle filter
■■ Height: 65 mm
height adjustment ††7000.12.00 7000.11.00
■■ Can only be used in connection
65

††7000.02.00
with a shingle filter
■■ Weight: 0.5 kg

300
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Cast iron


Drain body DN 50 7
Designation compatible with Description Article No.
Ø150
■■ Top frame with grating

21
■■ Cast iron
††7000.08.00
Top ring ■■ Load class: M 125 7000.05.00
††7000.44.00
■■ Weight: 0.8 kg
††7000.43.00
Ø152

■■ Top sections
■■ Coated cast iron
□200 ††5084.80.00
■■ Frame dimensions:
45

■■ Cellar drains DN 100


200 x 200 mm
Top frame ††5001.00.00 5079.80.00
■■ For incremental adjustment by
††5002.00.00
185 45 mm
■■ Top frame with grating
■■ Weight: 2.5 kg
††7000.43.00

Syphonic rainwater drainage


Cast iron

301
K9/1
Flat roof drains Jet
7 Drain body DN 80
Roof drainage   Syphonic rainwater drainage   Cast iron

Flat roof drains Jet syphonic rainwater drainage

Product information
■■ Drain body DN 80 ■■ With seepage openings
■■ Coated cast iron ■■ With function element
■■ With compression-sealing flange

Ordering information
Core hole dimension

Nominal Øa Øc b Article No.


Selection assistant

Øa
size [mm] [mm] [mm]

b
For drain body without isolating body
Syphonic rainwater drainage

DN 80 380 200 35 7038.10.10

For drain body with isolating body


Cast iron

DN 80 430 270 65 7038.10.10 Øc

Nominal Socket incli- Outflow Recess Weight Article No.


width nation value
[l/s] [mm] [kg]
Ø360
Ø188

DN 80 90° 17,0 290 x 410 12,1 7038.10.10


246

105

302
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Cast iron


Drain body DN 80 7
Components

Drain bodies upper part

Ordering information

Designation compatible with Description Article No.


Ø360
Ø200
■■ Coated cast iron
■■ With compression-
sealing flange in accor-
dance with EN 1253
■■ Flat roof drains Spin ■■ Non-flammable in ac-
††DN 100 – DN 150 cordance with building
Upper part 7044.10.25
■■ Flat roof drains Jet materials class A1
††DN 80 ■■ With sealing ring
275

Syphonic rainwater drainage


■■ With seepage openings
■■ Height-adjustability:
50 – 200 mm
■■ Weight: 12.6 kg

Cast iron
Ø154

Top sections and gratings

Ordering information

Designation compatible with Description Article No.


□296
80

44

■■ Not screwed in place 7000.41.00


16 ■■ Flat roof drains Spin
††DN 100 – DN 150
Top frame with grating
■■ Flat roof drains Jet
††DN 80
■■ Screwed in place 7000.42.00

Ø287 ■■ Flat roof drains Jet ■■ Stainless steel


††DN 80 ■■ With 2 mounting screws
Shingle filter 7000.12.00
15

■■ Flat roof drains Spin ■■ Load class: H 1.5


75

††DN 100 – DN 150 ■■ Weight: 1.2 kg

303
K9/1
Flat roof drains Jet
7 Drain body DN 80
Roof drainage   Syphonic rainwater drainage   Cast iron

Accessories

Designation compatible with Description Article No.


Ø117 ■■ Flat roof drains Spin
■■ Diameter: 117 mm
††DN 100 – DN 150
Sealing ring ■■ Thickness: 2 mm 7044.00.26
■■ Flat roof drains Jet
Ø12 ■■ For 2 piece design upper parts
††DN 80
Ø368
60
130

Ø190
■■ Flat roof drains Spin
††Socket inclination: 90°
††DN 100 – DN 150 ■■ Foam glass
Insulating body 7040.21.00
■■ Flat roof drains Jet ■■ Weight: 1.3 kg
††Socket inclination 90°
Syphonic rainwater drainage

††DN 80

266
430
400
Cast iron

210 ■■ For upgrade of the drain body


Ø135 ■■ Flat roof drains Jet DN 80 to a emergency overflow
Pilot tube
††DN 80 ■■ With sealing ring
■■ Weight: 1.3 kg
55
150

For 1 piece design 7048.10.50


For 2 piece design 7048.20.50
Ø135

■■ Mains supply: 220 – 240 V AC


■■ Nominal performance: 25 W
■■ Protection rating: I
■■ Protection type: IP X7
■■ All flat roof drains are made of ■■ Connection conduit:
Flat roof heating cast iron ††SIHF 3 x 1 mm² 7000.85.00
††DN 50 – DN 150 ††Length: 1.5 m
■■ Certified in accordance with
DIN VDE 0700, parts 1 and
223
■■ Weight: 0.5 kg
□450
100

■■ Foam glass
Insulating ring ■■ Flat roof drain upper part 7040.11.00
■■ Weight: 1.9 kg

Ø220

□450
50

Compensation ■■ Foam glass


■■ Flat roof drain upper part 7040.01.00
element ■■ Weight: 0.8 kg
Ø220

Ø199
Ø189 ■■ Top frame with grating, load
class: L 15 and M 125 ■■ Cast iron
45

Top ring 7000.45.00


■■ Gratings, load class: H 1.5 and ■■ Weight: 2.0 kg
L 15

■■ Stainless steel
Ø285
■■ With 2 mounting screws
■■ Shingle filter
■■ Height: 65 mm
height adjustment ††7000.12.00 7000.11.00
■■ Can only be used in connection
65

††7000.02.00
with a shingle filter
■■ Weight: 0.5 kg

304
K9/1
Hinweis: @@ Dies ist eine Infobox-VORLAGE
Zubehör AAAAA ➔ Seite xxx.
Zubehör BBBBB ➔ Seite xxx.
Infobox
Section contents Stainless steel flat roof drains 7

Roof drainage       Syphonic rainwater drainage       Stainless steel

Page
Basics 308

Flat roof drains 312

Flat roof drains Jet Drain body DN 40 – DN 100 Drain bodies lower part 314

Accessories 315

Syphonic rainwater drainage


Stainless steel

307
K9/1
Vacuum drain (stainless steel)
7 Planning references
Roof drain   Vacuum drain   Stainless steel

Basics

Stainless steel
The area of non-corrosive steels is de- example, in areas in which are located
scribed as stainless steel. However, this The flat roof drains of ACO Haustechnik directly by the ocean - the suitability of
generic term does not provide any conclu- are mass-produced from material grade the material used must be checked in any
sion of the quality of the steel grade used. 304. This material is resistant against case.
In waste water technology, material grade water and humidity. However, the material
304 with 18% chromium (Cr) and 10% is not suitable for all media, despite its
nickel (Ni) has prevailed. An austenitic, high-quality properties.
acid-resistant stainless steel suitable for In the event of an accumulation of aggres-
high temperatures has excellent hydraulic sive waste water or waste water contami-
characteristics due to its smooth surface. nated with chloride ions - this occurs, for

Single part drain body with compression-sealing flange


A compression-sealing flange consists of:

■■ A non-rotatable flange
Flange which is solidly connected to the
drain body.
■■ A rotatable flange
Flange with which the seal is pressed
against the non-rotatable flange to cre-
ate a tight connection.

2-part drain body with compression-sealing flange


Stainless steel
Vacuum drain

Installation in insulated roofs:

■■ Lower section
with compression-sealing flange to con-
nect with the vapour barrier.
■■ Drain body
with compression-sealing flange to con-
nect with the sealing membrane above
the insulation.
■■ Sealing element
standard, prevents the waste water
backflow from the downpipe from pen-
etrating the insulation.

308
K9/1
Vacuum drain (stainless steel)

Roof drain   Vacuum drain   Stainless steel


Planning references 7
Installation instructions
Recesses in concrete ceilings Insulated roof drains Protective cover during construc-
The recesses must be designed so that The insulating bodies of the roof drains of tion period
concrete can also be filled below the Styrofoam (PS 30 DIN 18164) may not be In order to keep the inlet bodies free of
flange (i.e. by inclining a side of the damaged. contaminants during the construction
recess). phase, they must be provided with a
Adjustment to the roof structure protective cover during the construction
Concreting in the roof drains Insulating layers of 25 - 200 mm thickness period (sleeve cap). The protective covers
The roof drains must be stabilized prior to may be bridged with the stacking element must be removed prior to the assembly
concreting so that the position cannot be of 2-part roof drains. An additional fitted of the stacking elements or gravel trap
shifted when sealing the concrete. pipe with an identical nominal width of the baskets.
inlet body must be inserted in
Sealing the roof drains DN 70 or DN 100 in an appropriate length Fire protection
Providing the roof drains with compres- in thicker insulation layers. The vertical flat roof drains Jet DN 70 can
sion-sealing flanges makes it possible to be equipped with a functional part with fire
include sealing membranes and foils of Backflow safety valve protection. The insulation here must be
various qualities in thicknesses up to 10 2-part roof drains are always delivered in designed in foam glass.
mm in the drain bodies. Depending on a backflow-safe version. This is required
the quality of the sealing membrane, the according to the valid DIN standards.
flange seals of EPDM/PVC soft or another
quality must also be inserted under the
sealing membrane.

Flat roof heater


ACO offers a heater for flat roof drains as in buildings at an extreme location, when In order to prevent an unnecessary energy
an option, so that the drain will not freeze. connected to a separate sewage system, consumption, it is recommended to

Stainless steel
Vacuum drain
This not only increases the functional in buildings that are occasionally not control the heated flat roof drains with an
reliability of the drainage system even heated during the winter months, drains additional thermostat.
at subfreezing temperatures, but is also that are located in shady areas, etc..
recommended by DIN 1986-100. A flat The regulations according to VDE and the
roof heater is recommended especially local EVU regulations must be observed.

309
K9/1
Vacuum drain (stainless steel)
7 Planning references
Roof drain   Vacuum drain   Stainless steel

Stainless steel vacuum drain

Gravel trap Gravel trap Overfill ring Gravel trap Overfill ring
top section top section top section

Gravel trap

Loose flange

Flange
seal

Drain
body

Insulating Insulating
ring ring
Stainless steel
Vacuum drain

Drain
body

Insulating
body Bottom part Drain Bottom part Drain
body body
Flat roof
heater

Insulation/insulating body Insulation/insulating body Insulation/insulating body Insulation/insulating body

310
K9/1
Vacuum drain (stainless steel)

Roof drain   Vacuum drain   Stainless steel


Planning references 7

Stainless steel
Vacuum drain

311
K9/1
Flat roof drains Jet
7 Drain body DN 40 – DN 100
Roof drainage   Syphonic rainwater drainage   Stainless steel

Flat roof drains Jet syphonic rainwater drainage

Product information
■■ Drain body ■■ Certified in accordance with EN 1253
††Horizontal: DN 40 – DN 70 ■■ With compression-sealing flange
††Vertical: DN 70/DN 100
■■ Stainless steel, material grade 304

Ordering information

Core hole dimension

Nominal Øa Øc b Article No. Øa


Selection assistant

size [mm] [mm] [mm]

b
For drain body without isolating body
DN 70 340 90 10 0174.46.79

DN 100 340 110 10 0174.46.81


For drain body with isolating body
DN 70 340 290 10 0174.46.79

DN 100 340 290 10 0174.46.81 Øc

Nominal Socket Flow rate Weight Article No.


width inclination
Syphonic rainwater drainage

in accor- with 75 mm
dance with accumula-
DIN tion
Stainless steel

[l/s] [l/s] [kg]


Ø332
85

DN 70 90° 15,0 15,0 3,3 0174.46.79


364

DN70

312
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Stainless steel


Drain body DN 40 – DN 100 7
Nominal Socket Flow rate Weight Article No.
width inclination
in accor- with 75 mm
dance with accumula-
DIN tion
[l/s] [l/s] [kg]
Ø332
Ø301

98

DN 100 90° 38,9 37,1 3,8 0174.46.81


370

DN100

Ø332
63

DN 40 1,5° 5,2 5,2 2,6 0174.46.43

Syphonic rainwater drainage


250

Ø332

Stainless steel
DN 50 1,5° 8,5 8,5 2,8 0174.46.44
71

72

250

Ø332

DN 70 1,5° 16,1 16,1 3,5 0174.46.45


92

250

313
K9/1
Flat roof drains Jet
7 Drain body DN 40 – DN 100
Roof drainage   Syphonic rainwater drainage   Stainless steel

Components

Lower part for DN 70 – DN 100

Ordering information

Designation compatible with Description Article No.


Ø233
■■ Stainless steel, material
grade 304
■■ Socket inclination: 90°
■■ With long socket
■■ Stainless steel flat roof ■■ With compression-
drains Jet sealing flange and
Lower part ††DN 70 loose flange in accor- 0174.46.69
370

††Socket inclination: dance with EN 1253


90° ■■ Plastic protective cover
during construction
period
■■ Inc. GM-X sealing
element
DN70

Ø233

■■ Stainless steel, material


grade 304
■■ Stainless steel flat roof
■■ Socket inclination: 90°
Lower part drains Jet/Spin 0174.47.16
Syphonic rainwater drainage

■■ With compression-
370

††DN 100
sealing flange in accor-
dance with EN 1253
Stainless steel

DN100

314
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Stainless steel


Drain body DN 40 – DN 100 7
Accessories

Designation compatible with Description Article No.


■■ Stainless steel flat roof drains
■■ Stainless steel, material grade
Jet/Spin series
Ø332 Slide flange 304
††DN 70
Ø232,5 ■■ Weight: 2.3 kg
††Socket inclination: 90°

For unheated version 0174.46.53


For heated version 0174.46.54
■■ Stainless steel, material grade
405
304
■■ Stainless steel flat roof drains ■■ Dimensions: 400 x 400 mm
120

Control shaft 0153.73.05


80

Jet/Spin series ■■ Height: 120 mm


10
□460 ■■ Load class: K 3
■■ Weight: 5.34 kg
Ø323
40

■■ Stainless steel, material grade


Shingle filter for inver- ■■ Stainless steel flat roof drains 304
0153.60.01
220

ted roof Jet/Spin series ■■ Load class: H 1.5


■■ Weight: 0.63 kg

LK=Ø233
14

□393 ■■ Stainless steel flat roof drains


20

■■ Installation height: 50 mm
Gulley grating Profiline Jet/Spin series
■■ Dimensions: 400 x 400 mm
50

■■ Profiline
□400
Galvanized steel 38150
Stainless steel, material grade 38156
304

Syphonic rainwater drainage


40
40

Stainless steel
■■ Stainless steel flat drains Jet/ ■■ Height-adjustability: 78 –
78-108

Gulley grating Profiline Spin series 108 mm


□400 ■■ Profiline ■■ Dimensions: 400 x 400 mm

Galvanized steel 38801


Stainless steel, material grade 38803
304

■■ Stainless steel flat roof drains


Flat roof heating 0174.84.32
Jet/Spin series
■■ Stainless steel flat roof drains
■■ Thickness: 4 mm
Flange seal Jet/Spin series
■■ Weight: 0.3 kg
■■ Parapet wall roof drains Spin

EPDM rubber 0174.42.87


DN

3
30 Soft PVC 0174.42.92
NBR/SBR 0174.42.97
■■ EPDM rubber
■■ Stainless steel flat roof drains
Flange seal ■■ For box channels 0174.42.95
Jet/Spin series
■■ Thickness: 5 mm

315
K9/1
Flat roof drains Jet
7 Drain body DN 40 – DN 100
Roof drainage   Syphonic rainwater drainage   Stainless steel

Designation compatible with Description Article No.


Ø92
Ø80
15
250 ±1,5

200 ±1,5

■■ Stainless steel flat roof drains ■■ For inlet/pipe socket


Jet ■■ Styrofoam, PS 30
Insulation 0174.46.55
††Socket inclination: 90° ■■ In accordance with DIN 18164
Ø73 ††DN 70 ■■ Weight: 0.09 kg
□145
50

Ø168
Ø160
32
57

70

Ø86 ■■ Styrofoam, PS 30
Insulation ■■ Intake guide ■■ In accordance with DIN 18164 0174.46.56
■■ Weight: 0.04 kg
□195
Syphonic rainwater drainage

250
Stainless steel

■■ Stainless steel flat roof drains ■■ For inlet/pipe socket


Jet/Spin series ■■ Rock wool, building material
Ø74 Insulation 0174.46.57
††Socket inclination: 90° class A1
Ø154
††DN 70 ■■ Weight: 0.06 kg
250

■■ Stainless steel flat roof drains ■■ For inlet/pipe socket


Jet/Spin series ■■ Rock wool, building material
Ø102 Insulation 0174.47.21
††Socket inclination: 90° class A1
Ø160
††DN 100 ■■ Weight: 0.06 kg

□205 ■■ Styrofoam
■■ Stainless steel flat roof drains
■■ Height: 250 mm
Insulation Jet/Spin series
■■ Length x width 205 x 205 mm
††Socket inclination: 90°
150

110

■■ Weight: 0.2 kg

DN 70 0174.47.18
5

5
105

DN 100 0174.47.19

Ø323
1,5 ■■ Stainless steel flat roof drains ■■ Stainless steel, material grade
Damming ring Jet 304 0174.46.75
††Socket inclination: 90° ■■ Weight: 1.1 kg
5,5
59

316
K9/1
Flat roof drains Jet

Roof drainage   Syphonic rainwater drainage   Stainless steel


Drain body DN 40 – DN 100 7
Designation compatible with Description Article No.
620
■■ Flat roof drains Jet
††DN 70
Ø215 ■■ Galvanized steel panel
Support sheet for ††Socket inclination: 90°
■■ Thickness: 1.5 mm 0174.46.61
trapezoidal tin roof ■■ Flat roof drains Spin
500

■■ Weight: 3.14 kg
††DN 70 – DN 125
††Socket inclination: 90°
620
■■ Stainless steel flat roof drains
Spin
■■ Galvanized steel panel
Support sheet for ††DN 70 – DN 125
92 ■■ Thickness: 1.5 mm 0174.47.26
Ø2 trapezoidal tin roof ■■ Stainless steel flat roof drains
500

■■ Weight: 3.0 kg
Jet
††DN 100

Ø292
Ø122
Ø96
96

13

Ø128 ■■ Construction with fire protection


Ø10
Ø171 ■■ Stainless steel flat roof drains
Shingle trap with compound
Jet 0174.77.03
airlock ■■ With technical authorization
††DN 70
(ABZ) Z‑19.17‑1872

Syphonic rainwater drainage


■■ Stainless steel flat roof drains ■■ Stainless steel


Ø76 Heat shield Jet ■■ With drive-in plug M8 and hexa- 0174.77.97
††DN 70 gon head screw M8 x 16

Stainless steel


0
Ø9
■■ Stainless steel flat roof drains
■■ Foam glass
341

Jet
Insulating body ■■ Socket inclination: 90° 0150.12.69
††Lower section DN 70
■■ Height: 100 mm
††Socket inclination: 90°
Ø370 5
34

5
Ø7
■■ Stainless steel flat roof drains
341

Ø1
68 Jet ■■ Foam glass
Insulating body 0150.12.70
††Socket inclination: 90° ■■ Height: 100 mm
††DN 70
Ø370 5
34

□145

■■ Stainless steel flat roof drains


■■ Foam glass
Jet
Insulating sheath ■■ Height: 100 mm 0174.77.93
DN ††Socket inclination: 90°
■■ For length adjustment
††DN 70

317
K9/1
Flat roof drains Jet
7 Drain body DN 40 – DN 100
Roof drainage   Syphonic rainwater drainage   Stainless steel

Designation compatible with Description Article No.


□205

■■ Stainless steel flat roof drains


■■ Foam glass
Jet/Spin series
Insulating sheath ■■ Height: 150 mm 0174.77.94
Ø105 ††DN 100
■■ As length adjustment
††Socket inclination: 90°

20 ■■ Stainless steel flat roof drains


Ø1
341

Spin ■■ Foam glass


Insulating body 0174.77.96
††DN 70/DN 100 ■■ Height: 100 mm
††Socket inclination: 90°
345
Ø370

DN1
■■ Stainless steel flat roof drains
Jet ■■ Galvanized steel
Optimization piece
††Socket inclination: 90° ■■ Weight: 0.5 kg
††DN 70
l

DN 70/DN 40 0174.12.69
89

Length: 95 mm
DN2
DN 70/DN 50 0174.12.70
Length: 105 mm
Syphonic rainwater drainage

DN1
■■ Stainless steel flat roof drains
Jet ■■ Galvanized steel
Stainless steel

Optimization piece
††Socket inclination: 90° ■■ Weight: 0.9 kg
††DN 100
l

DN 100/DN 70 0174.12.73
89

Length: 130 mm
DN2
DN 100/DN 80 0174.12.74
Length: 120 mm
■■ Galvanized steel
■■ Gulley grating Profiline
■■ Mesh width 30 x 10 mm
Mesh grating ††38150 38570
■■ Not screwed in place
††38801
■■ Weight: 0.9 kg
■■ Galvanized steel
Gulley grating Profiline
■■ Mesh width 30 x 14 mm
Mesh grating ■■ 38150 36754
■■ Not screwed in place
■■ 38801
■■ Weight: 0.9 kg
■■ Stainless steel, material grade
304
■■ Gulley grating Profiline
††Etched
Mesh grating ††38156 38573
■■ Mesh width 30 x 10 mm
††38803
■■ Not screwed in place
■■ Weight: 0.9 kg
■■ Stainless steel, material grade
304
■■ Gulley grating Profiline
††Etched
Mesh grating ††38156 36760
■■ Mesh width 30 x 14 mm
††38803
■■ Not screwed in place
■■ Weight: 0.9 kg

318
K9/1

You might also like