Professional Documents
Culture Documents
SCHELL角阀产品手册SLL 2352004 Geraeteanschluss-Armaturen GB WEB
SCHELL角阀产品手册SLL 2352004 Geraeteanschluss-Armaturen GB WEB
SCHELL角阀产品手册SLL 2352004 Geraeteanschluss-Armaturen GB WEB
By SCHELL.
SCHELL.
Appliance connection valves, a multi-talented fitting.
Plant 1 Plant 2
Production with administration building and training centre Production with logistics centre
2
FITTING TECHNOLOGY »MADE IN GERMANY«.
Table of contents
3
SCHELL inside.
SCHELL fittings belong in all places where robust, hygienic and resource-
efficient solutions are needed, such as in public, semi-public and commercial
sanitary rooms. Among others, our solutions can be found in the following
locations all over the world:
· Schools · Administrative buildings
· Nurseries · Airports
· Hotels · Railway stations
· Gastronomy · Motorway service stations
· Hospitals · Leisure facilities
· Residential nursing homes · Sports facilities
· Industry · Swimming pools
WC flushing systems
With their comprehensive range of
water-saving and hygienic WC
flushing systems, SCHELL also fulfils
the highest demands. These include
flush valves for wall-mounted
installation, concealed installation
solutions and concealed cisterns.
These can be controlled mechani-
cally or electronically as you choose.
All in all, ideal prerequisites for both
simple and speedy retrofitting in
renovation projects and for new-
build installations. A perfect match
– our mounting modules.
4
Mounting modules
SCHELL offers a complete range of
mounting modules. These are
distinguished by: Models for dry and
wet construction, compliance with
DIN 4109 (noise protection in
building construction) and a consi-
derable number of innovative
detailed solutions.
Angle valves
You can place high expectations on
Europe's market leader for angle
valves, including water-saving
functions, exceptional quality,
attractive design and an extensive
range for all applications. These are
available with an integrated
backflow preventer or filter
depending on requirements, and
almost every model is classified in
noise class I.
5
Quality features of SCHELL.
8 1
6
9
10
Materials made for drinking water 1 The high-tensile brass cone compression 8 The push-on rosette
Quality fittings by SCHELL meet all connection with length compensation s /PTICALLY UNIMPAIRED WALL SURROUND
ensures secure connections with copper variable with an 18 mm push rod
the requirements according to: pipes and flexible connection hoses 9 Metal retaining nut
TrinkwV 2001 German Drinking 2 The metal handwheel on the angle valve 10 Grommet made from stable plastic
Water Ordinance), DIN 50930 Part connection has a filter insert.
3 The filter
6, DIN EN 1717, KTW (German s -ADE FROM EXTREMELY DURABLE
recommendations for plastics that Hostaform C®, protects all sensitive
come into contact with drinking components connected.
s #AN BE EASILY RELEASED WITH A COIN OR
water). DIN 50930/6 states the a screwdriver and then cleaned under
conditions (alloy components) running water.
needed for brass to meet the re- 4 The double O-ring seal ensures ease
of movement, even after many years of
quirements of the Drinking Water operation.
Ordinance (TrinkwV). Responsible 5 The COMFORT handle provides a secure
use of drinking water as a resource grip in an elegant design.
6 The grease chamber upper part
requires the controlled use of s 4O PROTECT THE BRASS SPINDLE AGAINST
materials suitable for contact hard water.
with drinking water. s )S COMPLETELY SEPARATED FROM THE WATER mOW
ensuring continuous ease of movement.
7 The integrated Backflow Preventer (BP)
protects against reverse flow, back pressure
and back absorption of non-drinking water
into the supply system.
6
Tested quality.
Just like our customers, we place great value on materials, quality and
durable function. Our products are continuously tested and distin-
guished by the relevant quality and safety features:
Belgaqua
Test symbol for fittings tested in Belgium.
ASAG easy
The ASAG easy symbol indicates reliable installation, durable sealing
and easy assembly due to the self-sealing connecting thread.
GL
Quality management at SCHELL is certified by Germanischer Lloyd,
in accordance with DIN EN ISO 9001:2000.
7
Draw-off valves by SCHELL – versatile application.
Combination draw-off
valve COMFORT
Appliance connection fittings for reliable use of water in
the bathroom, kitchen, cellar and garden.
8
Draw-off valve COMFORT Combination draw-off valve COMFORT
9
Double auxiliary connection valve COMFORT
10
Auxiliary connection valves.
For subsequent connection of appliances.
AC valve COMFORT AC valve COMFORT for hot water appliances AC valve COMFORT for wall batteries
11
Appliance valves.
For connecting household appliances.
Filter combination angle valve (connect hose to solenoid valve) Easy filter cleaning
12
1
13
Safeguarding water – SECUR.
The lockable handle.
Safeguarding water
SCHELL SECUR is suitable to ensure the water connections are
safeguarded, e.g. in apartment buildings, filling stations, gardens and
greenhouses, industrial buildings, sport complexes, vehicle workshops,
garages, camping sites and all water connections accessible to the public.
14
Sink valves.
By SCHELL.
Sink set
15
Outdoor valves.
By SCHELL.
16
Supplementary products.
17
Protecting drinking water.
Safety fittings maintain the quality of drinking water.
**
Based on the DIN EN 1717, with the new DIN 1988-100 "Technical Regulations for drinking-
water installations", a German standard was created that is to be applied in parallel to the
EN 1717t. The DIN 1988-100 explains and instructs how the EN 1717 must be applied in
Germany. Selection of the suitable safety facilities is determined in the DIN 1988-100 by
a comprehensive list of applications for domestic and non-domestic use.
18
Protecting drinking water.
Water may only flow in one direction.
(without BP)
Stop BP BP
Back suction in a domestic dwelling, e.g. after a pipe bursting in Back pressure, e.g. with closed solenoid valve, cold water ingresses
the cellar. Action: Install a SCHELL wall connection elbow with BP into hot-water system. Action: Install SCHELL angle valves with BP
(Backflow Preventer) (Backflow Preventer).
19
Examples of applications incl. safety facilities, in accordance with DIN 1717 for the
domestic sector
Single tap points Appliance inclined-seat valve COM- Appliance inclined-seat valve COM-
FORT FORT
03 386 06 99
03 392 06 99
EB HD
03 545 06 99
03 549 06 99
EB HD
03 324 06 99
03 326 06 99
EB HD
03 545 06 99
EB
EB
Kitchen
03 908 06 99
EB
03 318 06 99
EB HD
03 390 06 99
EB
Combination angle valve with filter Appliance valve COMFORT AC valve COMFORT Fitting set COMFORT
COMFORT
03 560 06 99
03 374 06 99
03 309 06 99
10 862 06 99
EB EB EB EB
AC valve COMFORT
03 342 06 99
EB
03 387 06 99
03 388 06 99
EB HD
03 562 06 99
Single and multi- Appliance inclined-seat valve AC double valve
COMFORT
ple tap points
03 386 06 99
03 366 06 99
EB EB
tap points
03 459 06 99
External area
HD
Outdoor single Frost-proof outdoor wall fitting Frost-proof outdoor wall fitting POLAR
POLAR II II Set
tap points
03 996 03 99
03 998 03 99
HD HD
22
Draw-off tap SECUR Sanitary handle SECUR Sanitary handle SECUR
03 352 06 99
22 135 06 99
48 006 06 99
HD
23
Selection of appropriate safety fittings.
By SCHELL.
DIN EN 1717 subdivides the groups into five liquid categories, each of
which describes the hazard potential of the liquids.
24
F1 Potential hazard of liquids Examples 2
No hazard to health; water for human consumption that is Drinking water under elevated pressure
drawn directly from a drinking water installation.
No hazard to health with impaired odour, taste or colour. Drinks (coffee or tea), cooking foods, washing foods in
a domestic environment, treated drinking water, chlorine,
stagnant water
Hazard to health through minimally toxic substances Washing machines and dishwashers in a domestic
dwelling without free inflow, bath and shower tubs with
hose shower in a domestic dwelling, installations for filling
heating systems (water without inhibitors), aboveground
3 sprinkler systems, outlet valves with threaded hose
connection
Hazard to health through toxic substances Bath and shower tubs with hose sprays in clinics and care
homes, bath tub inlets under the rim of the tub in
domestic dwellings, underground sprinkler systems,
chemical cleaning facilities, installations (with inhibitors)
4 for filling heating systems
Hazard to health from microbial or virtual pathogens of Bathtub inlets under the rim of tubs in clinics and care
communicable diseases homes; large-scale cooking equipment, high-pressure
cleaners with chemical additives, toilet bowls and urinals,
filling devices for swimming pools
5
1 Category of liquid
2 Further details in Table NA.5 of the DIN EN 1717
25
Safety device
G Air gap with overflow, confirmed by test with negative pressure test
A Pressurized aerator
L
B Pressurized aerator, combined with downstream backflow preventer
26
Category of liquid
EN 17 17
Symbol 1 2 3 4 5
AA ώ ώ ώ ώ
AB ώ ώ ώ ώ
AC ώ ώ – –
AD ώ ώ ώ ώ
AF ώ ώ ώ –
AG Ϗ Ϗ Ϗ Ϗ
BA ώ ώ ώ ώ –
CA ώ ώ ώ – –
DA Ϗ Ϗ Ϗ – –
DB
DC Ϗ Ϗ Ϗ Ϗ Ϗ
EA ώ ώ – – –
EB 1
EC ώ ώ – – –
ED 1
GA ώ ώ ώ – –
GB ώ ώ ώ ώ –
HA ώ ώ Ϗ – – Protection device table:
The safety fittings to be installed are listed
in a table in the DIN EN 1717 norm. This
HB Ϗ Ϗ – – – table is used to determine up to which
liquid category safety is ensured.
HC 1 Note:
Installations with atmospheric ventilation
HD ώ ώ Ϗ – – (e.g. AA, BA, CA, GA, GB, …) must not be
installed if there is a risk of flooding, e.g.
installation in cellars.
LA Ϗ Ϗ – – –
Legend:
ώ covers the risk
LB
ώ ώ Ϗ – – Ϗ only covers the risk when p = atm
– does not cover the risk
1 Only for particular domestic use
27
SCHELL safety fittings cover the following applications.
Extract from DIN 1988-100 Pipe aerator only for Fittings combination
design C (RB) BP+PA
Installation instructions for safety devices
in domestic dwellings: Labelling in accordance with EN 1717 DA HD
The installation height states the distance
Comment:
Installation height: States the distance Large cooking appliances, boilers with
between the highest possible wastewater automatic filling of water for the
30 steam area or recooling facilities con- ώ
level in relation to the safety device.
vection steamers, pressure fermenting
Only use DIN 1988-100 in conjunction with DIN EN 1717:2011-08 and gives explanations
and instructions about using the EN 1717 in Germany. In addition, the user receives a list of
examples for the selection of safety equipment in drinking water installations for the
28 non-domestic environment.
Non-controllable Backflow Double Backflow
Preventer (BP) Preventer (BP) Tap changer
EB ED HC
- - >250 mm
Safety equipment
SCHELL Products
risk when p = atm at location of installation; - : does not cover the risk
- - - 28 612 06 99 DA
water Air
DA EB
Safety fittings can be single valves Pipe aerator DA, design C Backflow preventer EB
or a component of an outlet valve. s &UNCTION 4HE VALVE IS CLOSED s &UNCTION )N mOW DIRECTION
For specific applications, a com- under pressure in flow direction. the flow current opens a spring-
bination of different assemblies If there is a drop in pressure, loaded valve seat. If a liquid
(backflow preventer plus pipe the valve opens automatically flows in the opposite direction,
aerator) or using in the double and prevents the formation of the valve remains closed.
form (double backflow preventer) a pressure gradient towards the s )NSTALLATION INSTRUCTIONS .OTE
is specified. The safety fittings are inlet-side of the installation. flow direction
subdivided into groups (first letter) s )NSTALLATION INSTRUCTIONS 0AY s 3AFETY IN ACCORDANCE WITH
and types (second letter) according attention to the direction of EN 1717: Category 2/3
to DIN EN 1717. Example: back- flow, height above the process (domestic environment)
flow preventer "EB". water level 250/300 mm
s 3AFETY IN ACCORDANCE WITH
EN 1717: Category 2/3
(domestic environment)
30
HD
Combination BP and PA
31
95 414 00 99/1.02/13 C