Professional Documents
Culture Documents
DPK EDW EN 12M26 0000 18 12 21 - 12M26 - ElectricalWiringDiagram - C2002ElectronicGovernor
DPK EDW EN 12M26 0000 18 12 21 - 12M26 - ElectricalWiringDiagram - C2002ElectronicGovernor
DPK EDW EN 12M26 0000 18 12 21 - 12M26 - ElectricalWiringDiagram - C2002ElectronicGovernor
DPK-EDW-EN-12M26-0000-18-12-21 Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
Electric wiring diagram-Connection to the genset control panel
STARTING DROOP
! CAUTION FUEL ON
GAIN SPEED
C2002
SPEED CONTROLLER
IDLE
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Acturator
Remote Speed potentiometer
(Not supplied)
Speed sensor
Power switch for Speed
controller and actuator
(Not supplied)
Shut-down electromagnet
Baudouin.com
Technoparc du Brégadan - 13260 Cassis / France - Tel. +33 488 688 500
Electrical Wiring Diagram Date : 21-12-2018
PowerKit Engine - 12M26 (C2002) Page : 2/5
DPK-EDW-EN-12M26-0000-18-12-21 Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
Connection and schematic diagram for starter
Pilot relay 30
Terminal 50c: M5×0.8 30b
Torque: 2.2~2.8N.m
50
M
50c
31
Pilot relay Solenoid switch Motor
Terminal 31: 1/2"-13NUC (Negative terminal)
Motor Torque: 27.1~29.8N.m
1.The fitting of a starter lockout unit is recommended to prevent the starter restarted while engine is running;
2.Battery discharge current requirements 750CCA-900CCA at low temperature;
3.Total resistance of the main wiring is ≤8mΩ (Including Wiring resistance,contact resistance,internal battery resistance);
Rated Voltage Rated Power 4.Permissible resistance of the starter control wiring is ≤500mΩ.
5.Starter has double wire system, the terminal 31 should connect with the negative of battery.
24V 10kW
Terminal B-: M4
Torque: 0.8~1.2N.m
Terminal B+: M8
Torque:13~15N.m
B- B+ W
C
W
B+
Regulator
V
Terminal D+: M4 G D+
Torque:0.8~1.2N.m
Terminal W: M5
Torque:2.5~3.5N.m
Baudouin.com
Technoparc du Brégadan - 13260 Cassis / France - Tel. +33 488 688 500
Electrical Wiring Diagram Date : 21-12-2018
PowerKit Engine - 12M26 (C2002) Page : 3/5
DPK-EDW-EN-12M26-0000-18-12-21 Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
Connection and schematic diagram of oil pressure sensor A
Connecting fast-on
44 Internal pin M4 Range 0~10bar - Execution: Single pole
- Voltage: 6...24Vcc
WK G
bar Ohm - Measurimg range: 0÷10bar
0 10 +3 - Switching value: Close P=2±0.15bar, max
max 20
-5
2 52±4 5W non-inductive.
4 88±4 - Resistance 10~184Ω, Current: <85mA
6 124±5 - Max Pressure: 30bar for 2s
10 184 +20
-10
- Operating Temp.: -25~+100°C
- Max Operating Temp.: +120°C for 1h
max 40
- Weight: 0.15kg
Ø0.8 - Measurements at 20°C down
max 46 Signal 10~180Ω Alarm Switch
G WK
350
(Resistance value at 60℃ and 105℃ only for reference)
300
2 Detection circuit
250
11±0.3
Ω
40±1
T
200
sensor
150
Signal terminal Alarm switch
2 1 100
Ø10.8±0.3
When measuring the maximum current is less than 1mA;
4. Alarm temperature: 103℃±2℃ 50
M14×1.5-6g Max. loader capacity: 3W
Unlock temp.: Max. 3℃ below alarm temperature. 25 35 45 55 65 75 85 95 105 115 125 135 T(℃)
Baudouin.com
Technoparc du Brégadan - 13260 Cassis / France - Tel. +33 488 688 500
Electrical Wiring Diagram Date : 21-12-2018
PowerKit Engine - 12M26 (C2002) Page : 4/5
DPK-EDW-EN-12M26-0000-18-12-21 Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
Connection and schematic diagram of oil pressure sensor B
Signal terminal
Specification
G
M36x1.5-6g
(Pressure)MPa 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
(Output current)mA 91.5±2 70.5±161.5±1 53±1 47±1 43±1 39±1 35±1 31±1 27.5±1 24.5±1
Instrument (Equivalent resistance)Ω 10+3 48±3 82±3 116±4151±4 184±4 220±5 270±5 330±5 400±10 490±10
R0
-5
MCU sampling Alarming lamp Alarming lamp (Output Voltage)V (±0.1) 0.42 1.52 2.14 2.57 2.89 3.13 3.33 3.55 3.75 3.92 4.08
terminal Max. 24V/3W Max. 24V/3W
Rf 7. Alarming section
Alarming pressure:0.06±0.015MPa;
G WK Max. load capacity 24V/3W (resistance), lighting current of instrument
Cf
Specifications R(Ω)
Match with AMP C-282080 1. Max. permissible tightening torque 19.6N.m (2kgfm); R-T characteristic curve
2. Maximum power: 180mW at 25℃;
3. Sensor maximum working temperature 120℃; maximum 550
Alarm switch Signal terminal permissible temperature is 150℃ (lasts a maximum of 10
minutes); 6Feature point resistance and detection circuit is 500
as follows:
(1)Output resistance 450
S=19 -0.27
0
(2)Detection circuit:
250
T Ω
200
(sensor)
40±1
11±0.3
150
Signal terminal Alarm switch
2
100
1 When measuring the maximum current is less than 1mA;
4. Alarming 50
Lock temp 95℃±2℃ T(℃)
Ø10.8±0.3 Max. loader capacity: 3W
Unlock temp.: Max. 3℃ below lock temp; 25 35 45 55 65 75 85 95 105 115 125 135
M14×1.5-6g
Baudouin.com
Technoparc du Brégadan - 13260 Cassis / France - Tel. +33 488 688 500
Electrical Wiring Diagram Date : 21-12-2018
PowerKit Engine - 12M26 (C2002) Page : 5/5
DPK-EDW-EN-12M26-0000-18-12-21 Moteurs Baudouin reserve the right to modify these specifications, without notice. Document not contractual.
Connection of Shut-down electromagnet
B+ of Shut-down B+ of Shut-down
electromagnet is connected electromagnet isn't connected
Specification
1.Type of working : energized to stop;
2.The Shut-down electromagnet has to be
feed for 15 seconds during the stopping of
the engine
3.Voltage: DC24V
4.Consumed Power: 20W
5.The engine will be stopped after the
electromagnet is connected with battery.
Fuel returning 6.Working Pressure:(0.15-0.8)MPa
7.Switching Frequency:≥0.5Hz
8. Heat Resistance(-40~120)℃
Fuel inlet 9.Starting absorbing Voltage≥19V
10.Releasing Voltage≤6V
Fuel outlet
AMP Connector
Negative of Power Matching Connector
282080-1 (1) Connector
Already connected to the 282446-1 (2) Terminal AMP Connector
engine (ground) 282104-1 (1) Connector
281934-3 (2) Sealing 282465-1 (2) Terminal
281934-3 (2) Sealing
+24V
Negative Positive
Baudouin.com
Technoparc du Brégadan - 13260 Cassis / France - Tel. +33 488 688 500