Professional Documents
Culture Documents
Double Pipe Heat Exchanger New
Double Pipe Heat Exchanger New
Double Pipe Heat Exchanger New
http://excelcalculations.blogspot.com
Instructions
1) Define your Parameters (blue cells). Provide initial guesses for the parameter you will change in step 2 (i.e. mass flowrates)
2) Use Goal Seek to set value in Heat Balance to 0 by varying a parameter (e.g. flowrates)
Notes
Hot fluid is on the shell side, cold fluid is on the tube side
The log mean temperature difference is set up for cocurrent flow (but can be eaily modified for countercurrent flow)
PARAMETERS
Inside Pipe Thermal Conductivity kp 40 W m-1K-1
Hot Fluid Cold Fluid
Inlet Temperature Tin 120 9C
Outlet Temperature Tout 85 35 C
Thermal Conductivity k 0.7 0.78 W m-1K-1
Specific Heat Capacity Cp 4100 4070 J kg-1 K-1
Viscosity m 0.0003 0.0008 Pa s
Density rho 970 1000 kg m-3
Mass Flow Rate m 1.0323902 1.4 kg s-1
Inside Diameter di 0.07 0.0508 m
Outside Diameter do 0.08 0.054 m
Pressure Loss Coefficient Kp 1.23 1.23