CODES OF PRACTICE:
Building is designed for B+G+25 Floor
The structural design of the building will be documented in accordance with the
following codes.
I. Building Code of Pakistan
II. Uniform Building Code (UBC‐1997)
MATERIAL PROPERTIES:
MODULUS OF ELASTICITY:
SUPERIMPOSED LOADS:
S no. Pile Dia (inch) Pile Capacity (Ton) Pile Length (ft)
1- 36 345 Ton 85 ft
Zone 2B
Seismic Zone Factor "Z" 0.2 (Table 16‐I)
Soil profile Type (Soil Report) SD (Table 16‐J)
Occupancy Category "I" 1.0 (Table 16‐k)
Over Strength Factors "R" 5.5 (Table 16‐n)
Seismic Coefficient "Ca" 0.28 (Table 16‐Q)
Seismic Coefficient "Cv" 0.40 (Table 16‐R)
ACCIDENTAL TORSION:
The building with rigid diaphragm shall be design with the provision of 5%
eccentricities (in some cases) in seismic load application as per section 1630.6.
Method B TETABS
DURABILITY:
Concrete cover and minimum section dimension are chosen to satisfy the
fire endurance requirement of at least two hours, Minimum concrete clear
covers to main reinforcement as per ACI 7.7.1 shall be as follows:
Slabs 3/4”
Beams 1‐1/2”
Columns 1‐1/2”
Foundation (Bottom) 3”
Foundation (Top) 2”