SCAFF TAG NO: DV - AREA/LOCATION:

INSPECTED BY: IN GOOD CONDITION: YES NO


DESIGNATION : INSPECTION DATE:
SIGNATURE: NEXT INSPECTION DATE:
MINIMUM CHECKS TICK BOX MINIMUM CHECKS TICK BOX
FOUNDATIONS FIRM GROUND YES NO TIES CORRECT SPACING YES NO
BASE PLATE YES NO CORRECT DUTY YES NO
SOLE PLATE YES NO NOT RMOVED YES NO
NOT UNDERMINED YES NO LOAD BEARING FIITNGS YES NO
STANDARDS PLUMB YES NO FASTENED ACROSS 2 LEDGERS YES NO
CORRECT BAY SIZE YES NO DISTANCE FROM NODE POINTS YES NO
STAGGERED JOINTS YES NO ACCESS POINTS SUITABLE FOR THE TASK YES NO
FOOT TIES YES NO CLEAR OF ALL OBSTRUCTIONS YES NO
LEDGERS HORIZONTAL / LEVEL YES NO LADDERS CORRECT TYPE YES NO
CORRECT LIFT HEIGHTS YES NO GOOD CONDITIONS YES NO
STAGGERED JOINTS YES NO MIN. 1.05 M PAST STEP POINTS YES NO
SLEEVES YES NO CORRECT ANGLE YES NO
PAST END FITTING MIN 50MM YES NO MIN. TIED TWICE YES NO
TRANSOMS HORIZONTAL / LEVEL YES NO CORRECT LASHING / LIFTING USED YES NO
CORRECT SPACING YES NO TIE TUBE BENEATH RUNGS YES NO
CORRECT FITTINGS YES NO TIE TUBE SUITABLY STURDY YES NO
PAST END FITTING MIN 50MM YES NO NO BOUNCE ON LONG LADDERS YES NO
LEDGER BRACING ALTERNATE PAIR OF STANDARDS YES NO FIXED INTERNALLY ABOVE PROJECT LIMITS YES NO
END BASE BRACED YES NO GIN WHEEL CORRECT FIX TO SCAFFOLD YES NO
CORRECT FITTINGS YES NO CLEAR AREA FOR LIFTING/LOWERING YES NO
CORRECT ANGLE YES NO EXCLUSION AREA WHEN IN USE YES NO
EVERY LIFT YES NO CLEAR IDENFICATION MARKING YES NO
WITH IN 300MM OF NODE POINTS YES NO CLEAR SWL 50 KG MARKING YES NO
SWAY/FACADE EVERY SIXTH BAY YES NO ROPES CORRECT SIZE ( 18 MM ) YES NO
CORRECT FITTINGS YES NO GOOD CONDITION YES NO
EVERY LIFT YES NO CLEAR IDENTIFICATION MARKING YES NO
WITH IN 300MM OF NODE POINTS YES NO CORRECT KNOTS IN USE YES NO
POSITIONED TO LEDGER BRACED BAYS YES NO PREFABRICATED BEAMS GOOD CONDITIONS YES NO
PLAN/KNEE BRACINGS CORRECT FITTINGS YES NO BRACING IN PLACE YES NO
COMPLETE THROUGH AREA YES NO CHORD STIFFNER SPACING YES NO
WITHIN 300 MM OF NODE POINTS YES NO CORRECT FITTINGS YES NO
BOARDING CLOSE BOARD /NO GAPS YES NO BOTTOM LATERAL TIE TUBE YES NO
NO BAD BOARDS YES NO CHECK PINTS YES NO
NO TRAP END BOARDS YES NO REKERS , SPURS , TIE BACK/ NOT OVER EXTENDED YES NO
CORRECTLY LASHED / SECURED YES NO HANGERS & PUNCHEON CLOSE TO NOTE POINTS YES NO
BUILT END BOARDS YES NO LOAD BEARING FITTTINGS YES NO
NO CORRECT LAPPED BOARDS YES NO CORRECT CHECK FITTINGS YES NO
NO INCORRECT NAILED BOARDS YES NO CORRECT ANGLES YES NO
GUARDRAILS FULL EDGED PROTECTION YES NO CANTILEVER NEEDLES HORIZONTEL/ LEVEL YES NO
DOUBLE HAND RAILS YES NO LOAD BEARING FITTTINGS YES NO
MIN TOP RAIL HEIGHT 950 MM YES NO NOT OVER EXTENDED YES NO
MAX VERTICAL GAP 470MM YES NO LOADING CAPACITY MARKED ON SCAFFF TAG YES NO
CORRECT FITTINGS YES NO SUITABLE GRID SIZE YES NO
SOLID YES NO FITTINGS TIGHT YES NO
STOP ENDS IN ALL PRICE YES NO CORRECT QUALITY AND TYPE YES NO
TOE BOARDS MIN 150 MM HEIGHT YES NO HOUSE KEEPING TIDY SITE YES NO
COMPLETE / NO GAPS YES NO NO LOOSE MATERIAL YES NO
NO OVERSIZED / OVER SAILING YES NO PLATTFORMS CLEAR YES NO
MIN SECURED TWICE YES NO CLEAR WALKWASY / ACCESS WAYS YES NO
CORRECT FITTINGS YES NO SCAFF TAG CORRECTLY POSITIONED YES NO
YES NO AT EVERY ACCESS POINT YES NO

Decovision
SCAFFOLDING INSPECTION CHECKLIST

COMPLETE THE TICK BOX’S TO CHECK EACH ITEMS OF THE SCAFFOLD. TICK BOX
IN GOOD ORDER
REMEMBER ONE FAIL AND THE SCAFFOLD MUST NOT BE GREEN TAGGED
FAILED INSPECTION

N/ A
NOT APPLICABLE
DV-HSE-FM-40 REV 0 Issue Date: 01.01.2023