Kipor Kaynak Jeneratörü - Kde180xw
Kipor Kaynak Jeneratörü - Kde180xw
WELDER AND
G E N E R AT O R S E T
K D E 18 0 X W
K D E 18 0 E W
K D E 18 0 T W
5. Inspection, Repair and Trouble Shooting for Welder and Generator Set 29
5.1 Maintenance and rimedy 29
5.2 Question and problem 29
6. Appendixes 30
6.1 List for Tools, Accessories and Fittings with the Machine 30
6.2 Technical Documentation 30
6.3 The choice of the electric cable 31
6.4 Modified coefficient table of ambient condition power 32
- -
Set Type 2.2.2 Under the following conditions, the set should output the stipulated power
KDE180XW/EW KDE180TW
Item
and word reliably.
Rated frequency (Hz)
Generating Working
50 60 50 60
Rated power (kW) 2.8 2.8 2.8 2.8 Altitude height(m) Environment temperature( ) Relative humidity
State (AC)
Rated voltage (AC)(V) 230 240/120 230 240/120 1000 5-40 90%
Rated current (AC)(A) 12.2 11.7/23.3 12.2 11.7/23.3
Phase No. Single phase
Power factor (Cos ) 1.0
Welder and Generator Set
- - - -
1 QF1 Breaker 1
2 V Voltmeter (0-300V) 1
4 X1 X2 Receptacle 2
5 1
7 DT Stop electromagnet 1
9 Z1 Rectifier bridge 1
Winding
10 Z2 Rectifier bridge 1
Sampling
11 W1 Generating and sampling winding
Current Sampling
Black
Yellow/Green
12 W2 Excitation winding
13 W3 Vice winding
Red
Red
14 W4 Flywheel generator winding
Plate
- -
Driving
15 W5 12V winding
Absorb Plate
Red/Black Blue/Black White/Black
Blue
Plastic Sheath
16 W6 Welding winding
Plastic
Sheath
Pressure Switch
Plastic Sheath
20 SW Welding current select switch 1 Low oil pressure protector
21 Lp Shunt 1
23 IGBT 1
Welding output
24 IGBT control black and its assy 1
25 C Capacitor 2
27
28
1 QF1 Breaker 1
2 V Voltmeter (0-300V) 1
3 HL Operating indicator light (green) 1
4 X1 X2 Receptacle 2
5 SA Ignition switch 1 Charge Adjustor
Green
7 DT Stop electromagnet 1
Red
9 Z1 Rectifier bridge 1
Red
10 Z2 Rectifier bridge 1
Current Sampling
Black
Yellow/Green
Green
Red
Yellow/
Plate
Driving
13 W3 Vice winding
Plastic Sheath
14 W4
Absorb Plate
Red/Black Blue/Black White/Black
- -
Green
15 W5 12V winding
Yellow
White
16 W6 Welding winding
2.4.2 KDE180EW type electric wiring diagram
Start
Relay
17 W7 Control winding
Start
Motor
Plastic Sheath
21 Lp Low Oil
Blue
Shunt 1
Black
Black
Pressure Switch
22 L1 Plain wave reactor 1
Welding output
23 IGBT 1
Protector
24
Black
Protector
3.1.1 Fire prevention. The combustion oil used in the diesel engine is light
Start
diesel oil. The gasoline, kerosene and other oils should not be used.
Charge Adjustor
Relay
Use a clean cloth to wipe off the overflowed oil. The gasoline, kerosene, match
Start
Motor and other inflammable and explosive matters should not be put near the set
because the temperature for the place around the exhaust noise suppressor is
Pressure
Low Oil
Switch
Operating the welder and generator set should be carried out on a smooth floor. If
the set is oblique, the oil will overflow.
Red Blue
3.1.2 Prevent the suction of the exhausted gas
Plastic Sheath
Plastic
Sheath
The exhausted gas includes the poison carbon monoxide. At the places with poor
IGBTControl Black and its Assy
ventilation, the welder and generator set should not be used. If it is necessary to
operate the set indoors, the suitable ventilation condition should be supplied to
Plastic Sheath
Driving
Plate
prevent the personnel and livestock from the affection.
3.1.3 Prevent the burn. When the diesel engine is running and is hot, it is not
Qty.
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
3.1.4 Electric shock and short-circuit. In order to avoid the electric shock or the
Welding current select switch
Description
short-circuit, when the welder and generator set is wet or when your hand is wet,
Voltmeter (0-300V)
Welding winding
Charge adjustor
Control winding
Rectifier bridge
Rectifier bridge
Fuse( 6 30)
Ignition switch
contacting the welder and generator set is not allowed. This welder and generator
Vice winding
12V winding
4 X1 X2 Receptacle
Capacitor
Breaker
Battery
Shunt
set is not waterproof so that it should not be used at places in rain, snow and
IGBT
No. Parts No.
water mist.
AVR
QF1
FU1
SW
W1
W2
W3
W4
W5
W6
W7
GB
SA
YV
HL
Rp
Z1
Z2
Lp
L1
C
V
10
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
11
1
2
3
5
6
7
8
9
-6- -7-
NOTE At the time of the start, most motors will exceed their
rated power. On any sockets, the current should not
exceed the stipulated limit. Speed change lever
Stop
3.1.5 Other safety main points
Start/Run
In order to know how to quickly brake the set, the operators should be familiar
with operating all the switches. Anyone without passing through the correct
guidance should not carry out the operation. The operators should wear the
safety shoes and the suitable clothes. The children and livestock should be kept
far from the welder and generator set.
a. After purchasing the fuel, put the fuel in the
3.1.6 Charge the battery. barrel for 3 to 4 days.
The electrolyte of the battery contains sulphuric acid. In order to protect your eyes, b. After 3 to 4 days, put the suction pipe into
skin and clothes, if you touch it, it is necessary to use water for wash. If your eyes the barrel at the place with a half depth of the
barrel (water and foreign matter will be sunk a b
touch it, you should go to a clinic for wash.
The hydrogen produced from the battery is the explosive gas. Don't smoke onto the lower position in the barrel.)
particularly at the charge time. Any spark should not be splashed to the places
near the battery. NOTE At the places of filling the oil into the diesel engine or
of storing the diesel oil, don't smoke. Don't let any
Charge the battery at the places with good ventilation.
spark go into this area. At the time of filling the oil, the
oil should not be overflowed. After the oil filling, be
sure fastening the cover nut on the oil inlet.
-8- -9-
Top Limit
Operating temperature Don't fill the machinery oil into the diesel engine
WARNING
Recommended value when the diesel engine id running.
Type Applicable limit
Volume KM186FG A.P.I. Diesel engine maintenance
3.2.3 Check the air filter.
Volume (L) English gallon 1.65 (0.36) classification. The lubrication oil
should be CC or CD grade. (1) Unfasten the butterfly nut, open the filter cover, and take out the filter
core. Never wash the filter core by using any detergents. When the output
is reduced or the color of the exhausted gas is not good, change the filter
The factor of the affection, to the performance and reliability of the diesel engine,
core. Never start the generator set without the air filter core. Otherwise the
caused by your lubrication oil, is bigger than other factors. If you use any poor
diesel engine will soon be worn out.
quality machinery oil or if you do not change the oil for your diesel engine
according to stipulation, it is easy to block up the piston. It is also to quicken the Check Cover of Air-filter
wearing of the cylinder, bearings, and other moving components so that the life of
your diesel engine is reduced. Filtration Cover
Cover of Air-filter
Butterfly Screw
About one month or 20 hours Interval of 3 months or 100 hours
(2) After mounting the filter core, cover the air filter housing and fasten the
butterfly nut.
- - - -
3.2.5. Before delivering the diesel engine from the factory, the fuel oil and
the machinery oil had been discharged.
Before filling the fuel oil and starting the diesel engine, it is necessary to check
whether there is any air mixed into the oil circuit. If there is any, the air should be
discharged. The concrete method is to unfasten the connecting nut between the 3.3.3 Trial run operation
oil injection pump and the oil transmission pipe so as to discharge the air in the
When your diesel engine is a new set, a large loading will reduce the engine's
fuel oil until there is no air bubbles to be appeared. Then fasten the connecting
life. Within the first 20 hours, it is necessary to carry out the trial run.
nut again.
- - - -
Start the engine according to the following d. In the cold days, when it is difficult to start the
(1) Switch on the fuel oil switch (in ON rocker arm of the diesel engine and fill in 2ml
(2) Set the speed handle of the engine at Speed Handle cause the fast wearing of the inside components.
Speed Hande
3.4.2 Electric start
3.4.2.1 Start (the preparation for this start is the
same as the hand start.)
(1) Insert the electric door key and make it in
OFF position.
(2) Set the speed handle of the diesel engine in
(3) Draw out the buffer start handle. Decompression Lever run position.
a. Draw out the handle till you feel your hand (3)Turn the start switch to start position
let it restore to the initial position. (4) After the diesel engine starts, your hand should relieve the switch handle. Let
b. Press down the pressure reduction handle the switch restore to ON position automatically.
(when the buffer starter is drawn, it will (5)If the diesel engine doesn't start after 10 seconds, please wait for anther 15
automatically be restored.). seconds and make the start again.If the start motor rotates for a long time and the
voltage of the battery will go down to cause the start motor running hysteresis.
When the diesel engine is in operation always leave the start key in ON position.
- - - -
3.4.2.2. Battery
Check the electrolyte level height of the Liquid Top Limit
- - - -
Adjustment Bolt
-18- -19-
- - - -
- - - -
Air cleaner element replacement (Service more frequently when used in dusty areas) (Replace)
" " The chart above indicates which checks to make and when to make them, the mark ( )
indicates that special tools and skills one required, consult your dealer.
- - - -
- - - -
The control lever of speed is not at RUN position Put the control level to RUN position.
4.2.3 Pull out the rubber plug at the cover of diesel engine and ass 2ml of
lubricate in cylinder, and finally put the plug on its original place. Check the level of lubricant The specified oil level should be between
upper level H and lower lever L
4.2.4 Maintenance of starting position The speed and force to pull the recoil starter is not enough Start the diesel engine according to the
requirements of operating procedure of start.
(1) Manual starting The oil nozzle has dirty Clean the oil nozzle.
Press the pressure-reduce handle (non-compressin position), pull the recoil The battery has no electricity Charge it or replace it with a new one.
handle 2~3 times. (Don't start the diesel engine).
the electricity, without welder voltage.
The generator does not generate
Main switch (NFB) is not closed Put the main switch to the ON position.
(2) Electric starting The carbon brush of generator is not good Change the carbon brush.
When the starting handle is in the position of non-compressing position, operate The contact of socket is not good Adjust the feet of socket.
the diesel engine 2~3 seconds. When the switch is in the position of istart, don't The rated speed of generator ban not be reached Adjust if according to the requirements.
start the diesel engine. AVR auto-voltage regulator is damaged Change the AVR auto-voltage regulator.
The potentiometer for adjusting the welder current is damaged Change the potentiometer.
4.2.5 Pull the pressure-reduce handle out, pull the recoil starter slowly.
When fell it is fasten, then stop. (At this time the intake and drain valve is at the If electricity is still not generated, take the generator to a our Dealer.
status of close, it is suitable to prevent from rust).
5.2 Question and problem
If you have any question or problem when you meet in your operation, please
4.2.6 Clean and store it in a dry place. contact with our company or our dealer and tell the following information:
(1) The type of diesel generator sets, the No. and type of diesel engine and the
No. and type of generator.
(2) Status
What problem had been taken place when operation and explain how much
speed it is operated.
(3) Time of operation
(4) The other cetailed conditions, for example, when the problem took and what
time, etc.
For details, please fill the sheet of soliciting opinions from the customers and
send it to our company.
- - - -
Length
beneath 50m 75m 100m 125 150 200
Current
50A 14 14 22 22 30 38
100A 38 38 38 50 50 60
200A 38 2 38 2 38 2 50 2 50 2 50 2
300A 60 2 60 2 60 2 60 2 80 2 100 2
- - - -
Ambient temperature ( )
Altitude
(m)
25 30 35 40 45
Note: When the relative humidity is 60%, the modified coefficient is C-0.01
When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
When the rated power of generator is PN =5KW, altitude is 1000m, ambient
- -