EE1000

You might also like

Download as pdf
Download as pdf
You are on page 1of 2
NATIONAL INSTITUTE OF TECHNOLOGY, ROURKELA Department of Electrical Engineering End-Semester Examination, 2020 - 2021 (Spring) B.Tech r Subject Name: Basic Electrical Engineering Subject Code: E1000 Number of Pages: 2 Full Marks: 50 Duration: 2 Hours Figures at the right hand margin indicate marks. All parts of a question should be answered at one place. Attempt all questions. Be brief and to the point. 41, Find the load current J, through the load resistance R,, in the given circuit in Fig. 1 6) Fig. 1 2. For the circuit in Fig. 2, use the superposition theorem to find i %V gg G>) 49 42 fi 32 3a Fig.2 Contd. to the next page. 3, 10. End-Semester Examination Page 2 of 2 ‘The current source, “in Fig.3. Find the voltage across the 8 © resistor. av 6a 6a 6a sa or Fig. 3 A resistance of 60 ©, an inductance of 0.18 H and a capacitance of 120 uF are connected in parallel across a 100 V, 50 Hz supply. Calculate: (i) Current in each path, (Gi) Resultant current. (iii) Phase angle between the resultant current and the supply voltage. (iv) Power factor of the circuit. (¥) Draw the phasor diagram, © Two coils A and B are connected in series across a 230 V, 50 Hz supply. The resistance of coil A is 5 ohm and inductance of coil B is 5 mH. If the active and reactive power from the input are 4 KW and 3 KVAR respectively, then find the inductance of coil A and resistance of coil B. ©) A three-phase system supplies 1200 W to a star-connected load at 0.8 pf lagging when supplied from a 400 V star connected source. Determine the line and phase currents and the phase impedance. Also calculate the value of resistance and inductance of the load. (5) V,, = 231260" V is connected to a A- connected balanced load. The complex power absorbed by each phase of load is 2.5— jl.2 kVA. Calculate the phase and line currents and the per phase load impedance. (©) ‘An iron ring of mean length 40 em has an air gap of 2 mm and a coil with 1000 tums on it. If relative permeability of iron is 800 when a current of 1.5 A flows through the coil; find the flux. density. ) The efficiency of a 10 kVA, 2000V/400V, single phase transformer at unity power factor is 97% at full load and also at half load. Determine (i) its core loss and copper loss at full load (ii) the load current at which maximum efficiency occurs and value of the maxii iency. A balanced abe-sequence Y-connected source jum eff © The open and short circuit test data of a 250/500 V, 50Hz single phase transformer are as follows: (a) O.C. Test: 250V, | A, 80 W (on LV side) (b) S.C. Test: 20V, 12 A, 100 W (on HV side) Determine all the equivalent circuit parameters referred to the LY side. Draw the equivalent circuit. (5) End of Questions. ALL THE BEST

You might also like