PVsyst - Simulation report


Grid-Connected System

Project: Projet Hiba


Variant: Nouvelle variante de simulation
No 3D scene defined, no shadings
System power: 72.4 kWp
Kebili - Tunisia

Auteur
Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

Project summary
Geographical Site Situation Project settings
Kebili Latitude 33.71 °N Albedo 0.20
Tunisia Longitude 8.97 °E
Altitude 57 m
Time zone UTC+1

Meteo data
Kebili
Meteonorm 8.1 (1991-2000), Sat=100 % - Synthétique

System summary
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation Near Shadings User's needs


Fixed plane No Shadings Unlimited load (grid)
Tilt/Azimuth 30 / 0 °

System information
PV Array Inverters
Nb. of modules 108 units Nb. of units 3 units
Pnom total 72.4 kWp Pnom total 72.0 kWac
Pnom ratio 1.005

Results summary
Produced Energy 120323 kWh/year Specific production 1663 kWh/kWp/year Perf. Ratio PR 85.92 %

Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Predef. graphs 7
Single-line diagram 8

28/03/24 Page 2/8


Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

General parameters
Grid-Connected System No 3D scene defined, no shadings

PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate

Horizon Near Shadings User's needs


Free Horizon No Shadings Unlimited load (grid)

PV Array Characteristics
PV module Inverter
Manufacturer CSI Solar Manufacturer SofarSolar
Model CS7N-670MS Model SOFAR 24KTLX-G3
(Original PVsyst database) (Custom parameters definition)
Unit Nom. Power 670 Wp Unit Nom. Power 24.0 kWac
Number of PV modules 108 units Number of inverters 3 units
Nominal (STC) 72.4 kWp Total power 72.0 kWac

Array #1 - Champ PV
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 25.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs

Array #2 - Sous-champ #2
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 26.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs

Array #3 - Sous-champ #3
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 26.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs

Total PV power Total inverter power


Nominal (STC) 72 kWp Total power 72 kWac
Total 108 modules Number of inverters 3 units
Module area 335 m² Pnom ratio 1.00
No Power sharing

28/03/24 Page 3/8


Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 289 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Global wiring resistance 96 mΩ
Uv (wind) 0.0 W/m²K/m/s Loss Fraction 1.5 % at STC

Module mismatch losses Strings Mismatch loss


Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %

IAM loss factor


Incidence effect (IAM): User defined profile

10° 20° 30° 40° 50° 60° 70° 80° 90°


0.998 0.998 0.995 0.992 0.986 0.970 0.917 0.763 0.000

28/03/24 Page 4/8


Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

Main results
System Production
Produced Energy 120323 kWh/year Specific production 1663 kWh/kWp/year
Performance Ratio PR 85.92 %

Normalized productions (per installed kWp) Performance Ratio PR

Balances and main results

GlobHor DiffHor T_Amb GlobInc GlobEff EArray E_Grid PR


kWh/m² kWh/m² °C kWh/m² kWh/m² kWh kWh ratio
January 82.5 35.0 10.96 122.3 120.6 8182 8026 0.907
February 95.0 47.9 12.75 122.0 120.2 8080 7924 0.897
March 136.6 74.2 17.29 156.8 154.3 10210 10017 0.883
April 165.1 83.4 20.96 173.4 170.4 11051 10835 0.864
May 195.5 97.5 25.46 188.1 184.6 11776 11551 0.849
June 199.8 100.9 29.35 185.1 181.4 11427 11208 0.837
July 213.4 96.6 32.88 201.3 197.5 12196 11967 0.822
August 194.4 89.4 32.39 197.6 194.3 11992 11764 0.823
September 158.6 70.6 28.28 179.3 176.5 11088 10874 0.838
October 125.2 60.7 24.22 157.1 154.8 9959 9770 0.859
November 92.7 42.4 17.00 133.1 131.2 8725 8560 0.889
December 77.3 34.6 12.17 119.1 117.4 7979 7829 0.908
Year 1736.1 833.2 22.03 1935.3 1903.3 122665 120323 0.859

Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings

28/03/24 Page 5/8


Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

Loss diagram
1736 kWh/m² Global horizontal irradiation
+11.5% Global incident in coll. plane

-1.65% IAM factor on global

1903 kWh/m² * 335 m² coll. Effective irradiation on collectors

efficiency at STC = 21.65% PV conversion

138236 kWh Array nominal energy (at STC effic.)


-0.22% PV loss due to irradiance level

-8.55% PV loss due to temperature

+0.37% Module quality loss

-2.10% Mismatch loss, modules and strings

-1.04% Ohmic wiring loss


122665 kWh Array virtual energy at MPP
-1.91% Inverter Loss during operation (efficiency)
0.00% Inverter Loss over nominal inv. power
0.00% Inverter Loss due to max. input current
0.00% Inverter Loss over nominal inv. voltage
0.00% Inverter Loss due to power threshold
0.00% Inverter Loss due to voltage threshold
120323 kWh Available Energy at Inverter Output
120323 kWh Energy injected into grid

28/03/24 Page 6/8


Project: Projet Hiba
Variant: Nouvelle variante de simulation

PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1

Predef. graphs
Diagramme d'entrée/sortie journalier

Distribution de la puissance de sortie système

28/03/24 Page 7/8


PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1