Project: Projet Hiba
Variant: Nouvelle variante de simulation
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
Project summary
Geographical Site Situation Project settings
Kebili Latitude 33.71 °N Albedo 0.20
Tunisia Longitude 8.97 °E
Altitude 57 m
Time zone UTC+1
Meteo data
Kebili
Meteonorm 8.1 (1991-2000), Sat=100 % - Synthétique
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 108 units Nb. of units 3 units
Pnom total 72.4 kWp Pnom total 72.0 kWac
Pnom ratio 1.005
Results summary
Produced Energy 120323 kWh/year Specific production 1663 kWh/kWp/year Perf. Ratio PR 85.92 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 5
Loss diagram 6
Predef. graphs 7
Single-line diagram 8
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer CSI Solar Manufacturer SofarSolar
Model CS7N-670MS Model SOFAR 24KTLX-G3
(Original PVsyst database) (Custom parameters definition)
Unit Nom. Power 670 Wp Unit Nom. Power 24.0 kWac
Number of PV modules 108 units Number of inverters 3 units
Nominal (STC) 72.4 kWp Total power 72.0 kWac
Array #1 - Champ PV
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 25.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs
Array #2 - Sous-champ #2
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 26.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs
Array #3 - Sous-champ #3
Number of PV modules 36 units Number of inverters 2 * MPPT 50% 1 unit
Nominal (STC) 24.12 kWp Total power 24.0 kWac
Modules 2 Strings x 18 In series
At operating cond. (50°C) Operating voltage 140-1000 V
Pmpp 22.14 kWp Max. power (=>25°C) 26.4 kWac
U mpp 623 V Pnom ratio (DC:AC) 1.01
I mpp 36 A No Power sharing between MPPTs
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 289 mΩ Loss Fraction -0.4 %
Uc (const) 20.0 W/m²K Global wiring resistance 96 mΩ
Uv (wind) 0.0 W/m²K/m/s Loss Fraction 1.5 % at STC
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
Main results
System Production
Produced Energy 120323 kWh/year Specific production 1663 kWh/kWp/year
Performance Ratio PR 85.92 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
Loss diagram
1736 kWh/m² Global horizontal irradiation
+11.5% Global incident in coll. plane
PVsyst V7.3.1
VC0, Simulation date:
28/03/24 15:20
with v7.3.1
Predef. graphs
Diagramme d'entrée/sortie journalier