SF Series Panel Speed Controller

Features:

Adopts MCU digital control technology, which is rich in functions and has excellent performance.
Uses digital display menu options for easy and quick modification of settings.
Can set the display magnification according to user needs, and automatically convert and display target values.
Can achieve slow acceleration and deceleration.
Can be operated via the panel or external switch control.
The panel knob can automatically match the maximum speed, making speed control convenient and safe.
Built-in operating capacitor.
Overload protection function to prevent the motor and speed controller from burning out due to jamming. (Note:
This function can protect against overload caused by jamming, but cannot protect against non-jamming overload).

Model Lineup:
Power Power Voltage SF Series Panel Speed Controller SK Series Built-in Speed Controller
Category 220V 110V 220V 110V
6W SF06E SF06A
15W SF15E SF15A
25W SF25E SF25A
40W SF40E SF40A
SK200E SK200A
60W SF60E SF60A
90W SF90E SF90A
120W SF120E SF120A
200W SF200E SF200A

Performance Parameter
Model SF□□E SF□□A SK200E SK200A
Installation Panel Built-in
Method
Power Single Single Phase Single Phase Single Phase
Phase 220V 110V 220V 110V
Power 50/60 Hz
Frequency
Applicable YT Series Speed Control Motors
Motor Type
Operating Built-in (inside the speed controller) External (packaged separately with
Capacitor the speed control motor, needs to
be connected by the user)
Motion Control Panel or external switch operation External switch operation control,
Functions control, speed control, slow speed control, slow acceleration,
acceleration, slow deceleration slow deceleration, quick stop, 4-
speed stages
Speed Panel “▲” 、 “ ▼ ” Panel ; Panel Panel “▲” 、 “ ▼ ” Panel ; Panel
Adjustment knob knob;0~10V analog signal
Methods
Speed Range 90-3000 r/min. (User can set based on motor poles, power frequency, and
usage requirements)
Operating Temperature: -10℃~ +45℃(no freezing), Humidity: below 85% (no
Environment condensation).

Wiring Diagram for SF Series Panel Mount Speed Controller:

Note: The connection wires between the speed controller U1, U2, Z2 and the motor U1, U2, Z2 are strictly
prohibited from installing switches or relays.

Operating panel buttons control motor operation:

1) No need to install Kl, K2 switches.


2) Menu settings: Select "1" or "4" for operating panel button control in Motor Operation Control Method F-03.

External switches K1, K2 control motor operation:

1) Kl, K2 switches must be installed.


2) Menu settings: Select "2" or "3" for external switch control in Motor Operation Control Method F-03.
The power of YT speed control motor must be consistent with the applicable motor power of the speed
controller.

Please check whether the power of the speed controller model label is consistent with the motor power.

The power voltage must be consistent with the power voltage specification of the speed controller. QF is a circuit
breaker that protects the speed controller and speed control motor in case of a short circuit.

QF Circuit Breaker Current Rating Table:

FWD, REV are controlled by a programmable logic controller (PLC).


PLC output mode:
NPN or open collector transistor output.

Menu settings:
Select "2" or "3" for external switch control in Motor Operation Control Method F-03.

FWD, REV are controlled by sensors such as proximity switches, photoelectric switches, etc.
Switch output mode:
Three-wire NPN transistor output.
Menu settings:
Select "2" or "3" for external switch control in Motor Operation Control Method F-03.

Press and hold MODE for 3 seconds, the screen will display C100.
Press ▲ or ▼ to enter the password, password: 123.
Press ENTER to enter parameter modification mode.
Press ▲ or ▼ to select the parameter code.
Press ENTER to display the current set value.
Press ▲ or ▼ to modify the set value, press ENTER to confirm.
If the parameter is correct, it will briefly display "End" and move on to the next parameter code. If the parameter is
incorrect, it will display "Err" and prompt for re-entry.
Press ▲ or ▼ to modify the set value.
Press ENTER to display the current set value.
Repeat these steps to set the parameters.
Once finished, press the MODE key to exit.

Menu List for SF Series Panel Mount Speed Controller:


Parameter Parameter Setting Range Function Description Factory User Set Value
Code Function Default
Value
F-01 Display Content 1. Motor Speed Set Value Multiplier Speed Set Value =
2. Multiplier Speed Set Value Motor Speed Set Value / 1
Multiplier
F-02 Multiplier Setting 1.0~999.9 Set the displayed target value
1.0
according to visual needs.
F-03 Operation 1. Panel Button Control, Non- Choose "1" to control the motor 1
Control Mode memory using the panel buttons. When
2. External Switch Control, the speed controller power is
Panel STOP Button Disabled turned off and then back on, the
3. External Switch Control, speed controller does not
Panel STOP Button Enabled remember the operating state
4. Panel Button Control, With before power was turned off, and
Memory the motor remains in a stopped
state upon power restoration.

Choose "4" to enable the speed


controller to remember the
operating state before power was
turned off. Upon power
restoration, the motor will
resume its state from before
power was turned off. For
example, if the motor was
rotating forward before power
was turned off, it will immediately
resume forward rotation upon
power restoration. Please use this
function with caution and
prioritize safety.

When selecting external switch


control, use the FWD (forward)
and REV (reverse) external
switches K1 and K2 to control the
motor.
F-04 Rotation Mode: 1. Allow Bi-Directional These options restrict the
Rotation rotation direction of the motor,
2. Allow Forward Rotation, preventing equipment
1
Disable Reverse Rotation malfunctions or accidents.
3. Allow Reverse Rotation,
Disable Forward Rotation
F-05 Rotation 1. No Reversal These options allow for easy
Direction 2. Reversal adjustment of the motor rotation
direction without changing the
motor wiring. It ensures that the 1
rotation direction aligns with
personal preference or specific
requirements.
F-06 Speed 1. Panel ▲▼ Buttons Option 1 allows speed
Adjustment 2. Panel Knob adjustment using the panel ▲▼
Mode buttons within the minimum to
maximum speed range.
Option 2 enables speed 1
adjustment using the panel knob,
with the knob automatically
matching the range from 0 to the
max. speed.
F-07 Maximum Speed 500~3000 Setting a limit on the maximum 1400
motor speed helps prevent
overspeeding, which can lead to
damage or accidents. For a 50Hz
power supply, the maximum
speed is 1400, and for a 60Hz
power supply, the maximum
speed is 1600. If the maximum
speed exceeds these values, the
motor may overheat and vibrate.
F-08 Minimum Speed 90~1000 Setting a limit on the minimum
motor speed helps prevent
instability, overheating, and 90
overload caused by the motor
operating at low speeds.
F-09 Forward Start 0.1~10.0s Setting a longer time will result in
Acceleration a smoother and slower motor
Time start, while setting a shorter time 1.0
will result in a faster and more
abrupt motor start.
F-10 Forward Stop 1. Free Deceleration Stop When selecting the Free
Mode 2. Slow Deceleration Stop Deceleration Stop mode (Option
1), if the motor stops too quickly,
you can choose the Slow
Deceleration Stop mode (Option 1
2) and adjust the F-11 setting.
This allows you to control the
speed of the slow deceleration
stop.
F-11 Slow 0.1~10.0s This parameter is only applicable
Deceleration when F-10 is set to Option 2.
1.0
Time during
Forward Stop
F-12 Reverse Start 0.1~10.0s Setting a longer time will result in
Acceleration a smoother and slower motor
Time start, while setting a shorter time 1.0
will result in a faster and more
abrupt motor start.
F-13 Reverse Stop 1. Free Deceleration Stop When selecting the Free
Mode 2. Slow Deceleration Stop Deceleration Stop mode (Option
1), if the motor stops too quickly,
you can choose the Slow
Deceleration Stop mode (Option 1
2) and adjust the F-14 setting.
This allows you to control the
speed of the slow deceleration
stop.
F-14 Slow 0.1~10.0s This parameter is only applicable
Deceleration when F-13 is set to Option 2.
1.0
Time during
Reverse Stop
F-29 Restore Factory 1. Do not restore. 1
Defaults 2. Restore factory defaults.
F-30 Program Version Code + Version 01. **
Fault Alarm Er-1: 1) Overload or Locked Rotor Troubleshooting 1) Check and troubleshoot the issue.
2) Abnormal connection between the speed Steps: 2) Power off and then power on again
controller and the motor to clear the alarm.