Features:
Adopts MCU digital control technology, which is rich in functions and has excellent performance.
Uses digital display menu options for easy and quick modification of settings.
Can set the display magnification according to user needs, and automatically convert and display target values.
Can achieve slow acceleration and deceleration.
Can be operated via the panel or external switch control.
The panel knob can automatically match the maximum speed, making speed control convenient and safe.
Built-in operating capacitor.
Overload protection function to prevent the motor and speed controller from burning out due to jamming. (Note:
This function can protect against overload caused by jamming, but cannot protect against non-jamming overload).
Model Lineup:
Power Power Voltage SF Series Panel Speed Controller SK Series Built-in Speed Controller
Category 220V 110V 220V 110V
6W SF06E SF06A
15W SF15E SF15A
25W SF25E SF25A
40W SF40E SF40A
SK200E SK200A
60W SF60E SF60A
90W SF90E SF90A
120W SF120E SF120A
200W SF200E SF200A
Performance Parameter
Model SF□□E SF□□A SK200E SK200A
Installation Panel Built-in
Method
Power Single Single Phase Single Phase Single Phase
Phase 220V 110V 220V 110V
Power 50/60 Hz
Frequency
Applicable YT Series Speed Control Motors
Motor Type
Operating Built-in (inside the speed controller) External (packaged separately with
Capacitor the speed control motor, needs to
be connected by the user)
Motion Control Panel or external switch operation External switch operation control,
Functions control, speed control, slow speed control, slow acceleration,
acceleration, slow deceleration slow deceleration, quick stop, 4-
speed stages
Speed Panel “▲” 、 “ ▼ ” Panel ; Panel Panel “▲” 、 “ ▼ ” Panel ; Panel
Adjustment knob knob;0~10V analog signal
Methods
Speed Range 90-3000 r/min. (User can set based on motor poles, power frequency, and
usage requirements)
Operating Temperature: -10℃~ +45℃(no freezing), Humidity: below 85% (no
Environment condensation).
Note: The connection wires between the speed controller U1, U2, Z2 and the motor U1, U2, Z2 are strictly
prohibited from installing switches or relays.
Please check whether the power of the speed controller model label is consistent with the motor power.
The power voltage must be consistent with the power voltage specification of the speed controller. QF is a circuit
breaker that protects the speed controller and speed control motor in case of a short circuit.
Menu settings:
Select "2" or "3" for external switch control in Motor Operation Control Method F-03.
FWD, REV are controlled by sensors such as proximity switches, photoelectric switches, etc.
Switch output mode:
Three-wire NPN transistor output.
Menu settings:
Select "2" or "3" for external switch control in Motor Operation Control Method F-03.
Press and hold MODE for 3 seconds, the screen will display C100.
Press ▲ or ▼ to enter the password, password: 123.
Press ENTER to enter parameter modification mode.
Press ▲ or ▼ to select the parameter code.
Press ENTER to display the current set value.
Press ▲ or ▼ to modify the set value, press ENTER to confirm.
If the parameter is correct, it will briefly display "End" and move on to the next parameter code. If the parameter is
incorrect, it will display "Err" and prompt for re-entry.
Press ▲ or ▼ to modify the set value.
Press ENTER to display the current set value.
Repeat these steps to set the parameters.
Once finished, press the MODE key to exit.