2/81 PS 2500

Technical data
needle :
General data Power supply:
Power consumption:
Dimensions (W
x H x D):
Weight:
Record player
Type:

Drive:
Motor:
Turntable:

Turntable speeds: Needle


contact force:
Synchronization fluctuations:
Rumpel external voltage
distance:
Pickup
Model :
Type: Frequency
response: Channel
separation :
Channel deviation:
Yield (dynamic): Contact
force:
Impedance:
Replacement
able Automatic start automatic
return automatic stop automatic
220 ... 230 V, 50 Hz Belt drive
3W DC motor servo-controlled
Injection-molded aluminum
450 x 128.5 x 372 mm Diameter 31.7 cm
4.6 kg 33'/ and 45 rpm.
adjustable from 0 - 40 mN s 0 - 4 p
A + 0.07s/o Peak DIN B
u
t -70 dB DIN B
o
m
a Audio Technica AT-71 Magnetic
t pickup (MM) 20 Hz to 22 kHz + 2
i dB
c
23 dB at 1 kHz
t < 2 dB at 1 kHz
u 5 x 10"^ cm/dyn at 100 Hz 17.5
r + 2.5 mN (1.75 + 0.25 g)
n 47 kf2 || 100 pF
t
ATN-71

We reserve the right to make changes to the technical data.

The weight and dimensional data given are approximate values.


Note Tone arm lift (Fig. 4)
Do not adjust the tonearm suspension. If the tonearm is After changing the tonearm lift, or if the tonearm lift is not
defective, replace it completely. working, silicone OI must be filled into the hydraulic damping.
Proceed as follows:
Removing the base plate (Fig. 1) Unscrew the adjusting screw (press the tone arm lift
Unscrewsevenscrews andremove the base plate. guide while doing so) and fill in silicone oil.
Only use the original oil (part no. 75982-130.00).

(Fig. 4)

Changing the pickup system


A setting gauge (part no. 75982-240.00) is required when
(Fig. 1) inserting a different pickup system.
Proceed as follows:
1. Remove the foil from the gauge and place the gauge on the
Removing the automatic mechanism (Fig. 2) Six
plate holder (Fig. 5).
screws B out, cable pull through screw
2. Establish the following reference points with the old system
release, automatic mechanism with ladder
(Fig. 6). The center line of the system fastening screws must
remove the plate.
be perpendicular to the line of the gauge.
The outer edges of the system girder must be perpendicular
to the line of the gauge.
3. Carefully lower the tone arm with the lift and
not
e the
poi
nt at which the
ne
edle touches down on
the gauge.
4. Remove old system.
5. Insert the new system and screw it on loosely.
6. Align the needle of the new system with the previously
memorized point.
7. Tighten the system fastening screws.
(Fig. 2)

Removing the motor (Fig. 3)


Unscrewthree screws D and remove the motor.

(Fig. 6)

(Fig. 3)

2
12137
Settings Speed setting
If the speed cannot be set correctly with the speed setting,
Adjusting the tonearm lift height (Fig. 7 and 8) proceed as follows:
The tonearm lift height, i.e. the distance between the tip of 1. Remove the base plate (adjustment is made from below).
the needle and the record surface when the lift lever is raised,
2. Set the knob for speed adjustment to the center position.
has been set to 5 - 10 mm at the factory.
3. Set speed selector switch to 33'/a rpm. Turn control R 3
If you are using a different type of pickup or if further
so that the lower ring on the stroboscope appears to be
adjustments are absolutely necessary, make the adjustments
stationary.
as follows:
4. Set speed IwahI switch to 45 rpm. Turn control R 4 so that
1. Fit the needle guard to protect t h e needle tip from
the upper ring on the stroboscope appears to be
damage.
stationary.
Swivel the tonearm against the turntable axis.
Then check the settings by switching the speed selector
2. Turn the adjustment screw clockwise or counterclockwise switch.
while pressing down the tonearm lift guide.
Clockwise rotation
— The distance becomes
smaller. Counterclockwise Adjusting the tonearm touchdown point
rotation the automatic system (Fig. 9a)
— The distance increases. (Remove the rubber cap)

Note : If the contact point is outside the panel.

Since the adjusting screw with the hexagonal head in the — Turn clockwise.
lift guide i s engaged, the tone arm lift guide must be held If the touchdown point is in the playback section of the record.
down during adjustment so that the screw can be turned. — Turn counterclockwise.

On set point

(Fig. 7)

(Fig. 9)

Adjustment of the automatic


switch-off point (Fig. 9b)
(Remove the turntable support). If the
tonearm returns too early.
— Turn clockwise.
If the tonearm does not return after reaching the run-out
groove.
(Fig. 8) — Turn counterclockwise.

12137 3
Exploded view of
automatic mechanism

4 12137
Exploded view of complete
device

12137 5 6
220...230 V
(50 H z )

R10ì
î0k
2 J2
La1 R10
+C8I C6 100 k
FG 0,1p /
SOV
R9
0V 0,iy /50V 75 k

¡ Tr I 8 7 6 5
* C2
-- 0.02y/ 50y
1C 1 C7
B A 808 + 0.0i y/
C3 50 V

diagram
Circuit
TI R7
2 SD 947 R6 560k
C 11 15 k
2Œl p F R8
l6V C5 374k

R3 R4
20k 20k 15
lVRll R2

RI
10W
î2

Fro
m ¢5 R5
5k
S2 ( VR 3