Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Lab 1- PV PANEL STUDY

GAGAN C JAIN
201EE220

Fig- PV Solar Panel

Fig - Junction Box


Solar Panels Specifications:
1. Model - HHV Solar HST36F150P
2. Pmax= 150W
3. Voc=22.75 V
4. Isc= 8.65 A
5. Max System Voltage= 1000V
6. Output Tolerance= -0/+4.99 W

In each condition , there are 3 testcases -


1. When all cells are functional
2. When one of the cell is covered(dis functional)
3. When two cells are covered (dis functional)

Readings and calculations-

At no-load conditions
North-South
Case 1- V= 8.29 V
Case 2- V= 4.5 V
Case 3- V=3.95 V

South-North
Case 1- V= 15.19 V
Case 2- V=9.6 V
Case 3- V=7.01 V

East West
Case 1- V= 15.3 V
Case 2- V= 8.15 V
Case 3- V=4.1 V

West-East
Case 1- V= 16.28 V
Case 2- V= 8.41 V
Case 3- V=4.3 V

At Load condition of R=5Ohms


North-South
Case 1- V= 11.6 V
Case 2- V= 7.35 V
Case 3- V=2.65 V

South-North
Case 1- V= 8.8 V
Case 2- V=6.9 V
Case 3- V=2.41 V

East West
Case 1- V= 10.5 V
Case 2- V= 7.11 V
Case 3- V=2.518V
West-East
Case 1- V= 12.34 V
Case 2- V=7.67 V
Case 3- V=2.82 V