IN09 Vol VII 1 PD Preamble

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 156

CONTRACT NO: IN-09

VOLUME VII

Pricing Document
Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

VOLUME VII: PRICING DOCUMENT


Indore Metro Rail Project (Yellow Line & Depot)
TABLE OF CONTENTS
1. PREAMBLE ................................................................................................................. 2
1.1 General Requirements.............................................................................................. 2
1.2 Procurement Program .............................................................................................. 3
1.3 Tender Prices ............................................................................................................ 3
1.4 Price Variation........................................................................................................... 4
1.5 Quantities .................................................................................................................. 6
1.6 Units and Currency ................................................................................................... 6
1.7 Rates & Sums to be for Work Finished Complete .................................................. 6
1.8 Allowances in Rates and Prices .............................................................................. 7
1.9 Non-priced Items ...................................................................................................... 8
1.10 Tender Pricing........................................................................................................... 8
1.11 Measurement and Payment...................................................................................... 9
2. EXPLANATORY NOTES TO BILL OF QUANTITIES (“BOQ”).................................. 15
2.1 General .................................................................................................................... 15
2.2 132 kV / 33kV Receiving SUBSTATIONS ............................................................... 15
2.3 33 kV Cables ........................................................................................................... 25
2.4 33kV Switchgear ..................................................................................................... 29
2.5 Auxiliary Substations ............................................................................................. 33
2.6 Traction Substations .............................................................................................. 44
2.7 Third Rails and Stinger ........................................................................................... 53
2.8 Earthing & Bonding ................................................................................................ 63
2.9 SCADA ..................................................................................................................... 66
2.10 General .................................................................................................................. 104
2.11 Civil and Building Works including Electrifications Works for RSS & TSS ...... 109
2.12 Items not covered vide above Subhead .............................................................. 112
Annexure – A. Details of all Taxes/Duties/Levies/Royalties etc.
Annexure – B. IEEMA Circular (PC clause no. 13.7, Vol-II) for Price Variation.

Volume VII – Pricing Document Page 1 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

1. PREAMBLE
1.1 General Requirements
1.1.1 The Pricing Document as contained in this Volume VII, is comprising two parts.
The first part includes Preamble, instructions and conditions. The other part
includes Financial Bid, a bidding sheet in excel file form. The Tenderer shall
complete the Pricing Document in accordance with the instructions given. The
completed Pricing Document including duly signed Preamble (first part) and a true
copy of all documents of Financial Bid (other part) with prices left blank shall be
submitted with the Technical Package. The Financial Bid duly completed and
priced in all respect shall be submitted under Second Cover “FINANCE” only.
1.1.2 This Pricing Document shall be read in conjunction with the Instructions to
Tenderers, General and Particular Conditions of Contract, Notice Inviting Tender,
Employer’s Requirements, Technical Specifications, Material & Workmanship
Specifications, Tender Drawings and any Reference Documents etc., including
annexure, appendix, addendum or corrigendum and any - other documents
forming part of the Tender Documents. If the specifications in the scope of work,
Employer’s Requirement, Technical Specifications and/or Material & Workmanship
Specifications are inferior with respect to relevant codes and standards then
provision of the Codes and Standards shall prevail and vice-versa. The decision of
the Engineer regarding this issue shall be binding on the contractor.
1.1.3 The Pricing Document comprises Bill of Quantities for Indore Metro Rail Project
(Yellow Line & Depot). This Preamble shall serve as a definitive guide to the
measurement of quantities and payment.
1.1.4 This Contract is a re-measurement Contract for “Engineering, Supply, Erection,
Testing and Commissioning of Power Supply Receiving Sub–Station (RSS),
Traction Sub-Station (TSS), Auxiliary Sub-Station (ASS), 750 V DC 3rd Rail and
SCADA System”. The scope also includes Integrated Testing and Commissioning
of 132 KV Receiving Substations, 33 KV Rings, Auxiliary Substations, Traction
Substations, DC Cables, SCADA, Stray current Monitoring system and associated
works. The Contract also involves design and supply of equipment and accessories
for 3rd rail system and erection, testing and commissioning of the 3rd Rail system.
The Contract includes associated civil works (RSS, Depot TSS). The Contract
includes the following but is not limited to:
1.1.4.1 The construction studies and drawings, validation of design, verification of site
data, drawings, programs for execution, schedule of ordering, schedule of receipt
of equipments at site etc.
1.1.4.2 The procurement of the whole equipments including:
a) spare parts,
b) tools, testing equipment,
1.1.4.3 The on-site erection and setting to work of the electrical fixed installations and
technical buildings described in the relevant Basic Design documents,
1.1.4.4 The in-plant testing, and acceptance tests,

Volume VII – Pricing Document Page 2 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

1.1.4.5 The on-site testing,


1.1.4.6 The commissioning of installation, acceptance protocols and integrated testing and
commissioning of the system.
1.1.4.7 The supply of relevant documentation mainly including:
a) Installation, execution, and as-built drawings,
b) Test procedures,
c) Maintenance operation manuals: The Contractor is required to submit soft
copies of all the documents,
1.1.4.8 Training in India.
1.1.5 The Tender shall be for systems, subsystems etc. for (i) one corridor viz. Yellow
Line of Indore Metro (ii) the depot at Gandhi Nagar, Indore (iii) the Integrated
Operation Control Centre (OCC) at Gandhi Nagar Depot and back up control
centre (BCC) at Khajrana Square. .
1.1.5.1 Quantities under the Tender have been estimated to cover the above works /
sections.
1.2 Procurement Program
1.2.1 The Contractor shall submit a detailed works program as per the provisions of the
GC and PC (Vol-II). This shall also include a detailed procurement program. The
Contractor shall obtain approval of works program and procurement program from
Engineer before commencing with the procurement of material.
1.2.2 The procurement of the material shall be planned in a phased manner such that
the material reaches at site three to six months in advance of the proposed erection
plan for the same.
1.3 Tender Prices
1.3.1 The Tenderer's attention is drawn to the following facts while quoting the prices for
the Contract:
1.3.2 The rates and prices to be quoted by the Tenderer for each item in the Bill of
Quantities shall be inclusive of all taxes, levies, duties and any other charges
leviable, including tax deducted at source. The details of all
Taxes/Duties/Levies/Royalties etc. included in the Quoted price are required to be
furnished separately as estimated by the tenderer as per Annexure-A.
1.3.3 The Tenderer should note that MPMRCL will not make any separate payment
towards any taxes, duties levies or any other charge leviable.
1.3.4 The rates and prices quoted by the Tenderer and accepted by the Employer shall
be 'fixed' throughout the Contract Period except for items as mentioned in Clause
1.4 of this Document, which will be subject to Price variation. Sub Clause 13.7 of
Particular Conditions of Contract- Volume II may be referred.
1.3.5 The prices quoted in the excel sheet “BoQ” of the Financial Bid (excel workbook)
shall match with the quoted prices in the excel sheet “TT” (Financial Bid: Tender

Volume VII – Pricing Document Page 3 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Total) of the Financial Bid (excel workbook). In case of any mismatch the prices of
the excel sheet “TT” (Financial Bid: Tender Total) of the Financial Bid (excel
workbook) shall prevail. The excel sheet “BoQ” of the Financial Bid (Financial
Package) excel workbook and comparison generated by eProcurement portal shall
not be considered for determining inter-se position of tenderers.
1.4 Price Variation
1.4.1 Prices quoted by the Tenderer shall be fixed throughout the Tenderer’s
performance of the Contract and not subject to variation on any account except for
items indicated in following clause.
1.4.2 For items manufactured in India and quoted in Indian rupees in the tender the price
variation shall be subject to price variation as per relevant IEEMA formula, given in
Annexure-B at the end of this Volume and prescribed in PC Clause No 13.7 of
Volume-II.
Table 1: Items under Price Variation

SN Item Description Reference Bill No. Reference Item


No.

1. Power IN-1.1, IN-1.2, IN -1.3 B.1.1


Transformer

2. 33 KV Cable IN -2.1, A.1.1


A.2.1,
A.3.1, A.3.2
A.4.1, A.4.2

3. 33 KV Switchgear IN-1.1, IN-1.2, IN-1.3 C.1.1


Panel
IN-3.1, A.1.1, A.1.2,
A.1.3, A.1.4,
A.1.5, A.1.6,

4. 750 V DC Cables IN-5.1, B.2.1, B.2.2,


B.3.1, B.3.2
B.4.1, B.4.2

5. Return Feeder IN-5.1, B.5.1, B.5.2


DC Cable

6. Structure Earth IN-7.1, A.2.1


Cable

7 Bus Duct IN-5.1, B.1.1

Volume VII – Pricing Document Page 4 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

SN Item Description Reference Bill No. Reference Item


No.

8 Battery Charger IN-1.1, IN-1.2, IN-1.3 F.1.2


(RSS)

9 Battery Charger IN-4.1 B.1.2, B.1.4


(ASS & TSS)

1.4.3 The price variation shall be payable on the basis of relevant IEEMA formulas
(website www.ieema.org) for items in above table.
1.4.4 For items manufactured offshore (outside India) and quoted in foreign currency
(USD, EURO) the price variation will be governed by the formula given below. For
“Conductor Rail” [BOQ Bill No. IN-6.1– Item No. A.1], the price adjustment shall be
linked to spot rate of aluminium quoted at London Metal Exchange (LME), and shall
be as under:
Price Adjustment = 0.75 x Accepted Price x [Current Index – Base Index] x f
Base Index
Where;
Current Index is the spot rate cost of aluminium as given on the L.M.E. (London
Metal Exchange) 28 (twenty-eight) days prior to the date of notification to Engineer
/ Employer for inspection of material;
Base Index is the cost of aluminium as given by the L.M.E. (London Metal
Exchange) 28 (twenty-eight) days prior to the latest date of Tender submission;
f = Zo / Z1
Zo is the number of units of the currency of the index which is equivalent to one unit
of bid currency as applicable on 28 (twenty-eight) days prior to the latest date of
Tender submission; and
Z1 is the number of units of the currency of the index which is equivalent to one unit
of bid currency as applicable on 28 (twenty-eight) days prior to the date of
notification for inspection.
Note: The exchange rates to be employed for such conversion shall be the TT
selling rate of State Bank of India at the close of business of the State Bank of India
on the respective date.
1.4.5 The price variation on equipment indicated in clause 1.4.2 and 1.4.4 above shall
be applicable for supply prices only. The erection prices shall be subjected to price
variation as per PC Clause No 13.7 of volume-II.
1.4.6 For items covered under IEEMA price variation clause, the latest date of delivery
for considering price variation shall not be later than 180 (one hundred and eighty)
days before the relevant Key Date for commissioning. However, if the price
variation calculated as per the actual date of delivery is resulting in a price

Volume VII – Pricing Document Page 5 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

advantage to the Employer; the actual date of delivery shall be considered for
evaluating the price variation.
1.4.7 For Conductor Rail, the latest date of notification for inspection of material for
considering price variation shall not be later than 60 (sixty) days before that
relevant Key Date for procurement of Third Rails and associated items. However,
if the price variation calculated as per the actual date of notification of inspection is
resulting in a price advantage to the Employer; the actual date of notification shall
be considered for evaluating the price variation.
1.4.8 The total admissible price variation amount for this Contract shall be subject to a
ceiling of ± 5 % (five percent) of the Contract Price.
1.4.9 Price variation that may accrue during the period from the date of tender
submission will not be considered for Tender evaluation and for deciding inter-se
position of the Tenderers.
1.5 Quantities
1.5.1 For the purpose of this Contract, all unit quantities given in the Bills of Quantities
are the estimated quantities of the Works and are intended in the first instance to
provide a common basis for Tendering and Tender Evaluation. When a contract
has been entered into, the function of priced Bills of Quantities is to provide for the
valuation of the work executed. No alteration of any rate or price shall be allowed
on account of any difference between the quantities billed and the actual quantities
measured from the drawings.
1.5.2 The Tenderer shall make himself completely acquainted with all conditions,
obligations, specifications, drawings, etc. of the Tender Documents before giving
his prices. He shall have no right to claim any price revision on the basis of
ignorance of the Tender Documents or local conditions, or to make any claims as
regards the integrity of the unit prices of the Bills of Quantities.
1.6 Units and Currency
1.6.1 All sizes and quantities entered in the Bills of Quantities are in metric units.
1.6.2 The Tenderer shall fill in each column with unit rate or lump sum, whichever the
case may be, for each bill item of the various Bills, on the basis of the Tender
Documents and pre-tender survey.
1.6.3 The Tenderer, in addition to Indian Rupees, may quote in foreign currencies
(restricted to US, Dollar & Euro).
1.7 Rates & Sums to be for Work Finished Complete
1.7.1 Tenderers shall be deemed to have read the Work’s Requirements and other parts
of the Tender Documents and reviewed the Drawings to ascertain the full scope of
the requirements included in each item prior to filling in the rates and prices. The
entered rates and prices shall be deemed to include the full scope of the Contract,
including overheads and profits and shall bear a proper relationship to the cost of
carrying out the work described.
1.7.2 Notwithstanding any limits that may be implied by the wording of the individual

Volume VII – Pricing Document Page 6 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

items and/or the explanations in the Preamble, the rates and prices, which the
Tenderer enters in the Bill of Quantities, shall be for the work finished complete in
every respect.
1.7.3 The Tenderer shall be deemed to have taken full account of all requirements,
liabilities, obligations and risks, whether expressed or implied, and to have priced
the items accordingly. The Items in the Bills of Quantities are the only items against
which payment will be made. The cost of any item of work not specifically described
or measured in the Bills of Quantities but required for the execution of the Contract
shall be included in the rates and prices for the measured items in the Bills of
Quantities. The rates and prices shall therefore include for all incidental and
contingent expenses and risks of every kind necessary to supply, install, test and
commission (including Integrated Testing and Commissioning) complete, and
remedying any defects in the whole of the Works in accordance with the Contract.
1.8 Allowances in Rates and Prices
1.8.1 Full allowance shall be made in the rates and prices against the various items in
the Bills of Quantities for all costs involved in performing the following except to the
extent that work is specifically described and paid for in the Bills of Quantities. The
list below is not exhaustive and the Tenderers are expected to take all costs
involved while quoting the rates and prices that will not be subject to variation on
any account.
a) all setting out and final survey work;
b) temporary access roads and bridges, fencing, watching and security, lighting;
c) paying fees and giving notices to Authorities;
d) payment of all patent rights and royalties;
e) reinstatement of the Site;
f) safety precautions and all measures to prevent erosion and suppress fire and
other hazards;
g) interference to the Works by persons, vehicles, and the like being legitimate
users of the facilities on or in the vicinity of the Site;
h) the protection and safety of MPMRCL trains and services;
i) the protection and safety of Railway trains and services on adjacent tracks;
j) supplying, maintaining and removing on completion, the Contractors own
accommodation, offices, depots, stores, workshops, transport, welfare
services and other facilities including telephones and facsimile machines and
all charges in connection therewith;
k) the supply, inspection, testing, packaging and transportation of materials and
of the Works as specified including the provision and use of equipment and
arrangements for the Engineer's Inspectors and others;
l) maintaining public thoroughfares and footpaths, and maintaining access upon
existing recognised routes;

Volume VII – Pricing Document Page 7 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

m) providing, transporting to the Site, setting to work, operating (including all fuel
and consumable stores), maintaining and removing from the Site upon
completion all Construction Plant and Contractor's Equipment necessary for
the execution of the Works and including the cost of all tests and other
requirements in respect of such; plant and equipment;
n) working adjacent to or across existing services and installations;
o) complying with the requirements of the Employer in regard to Safety and
Health, Quality Assurance, Environmental and project implementation plans
and making periodical submissions;
p) co-ordination and interference to the Works by the works of Designated
Contractors and others employed by MPMRCL being legitimate users of the
facilities on or in the vicinity of the Site;
q) remedying of defects and shrinkage, and works of amendment,
reconstruction, replacement of other faults, fair wear and tear excepted,
during Defects Notification Periods;
r) protections to be implemented against Electromagnetic interference effects
following line energization;
s) Insurance, including all risks in supply, erection, storage, transit, third party,
Workmen’s Compensation and others;
t) All tools, and equipment required for all tests prior and after delivery and for
testing and commissioning installed systems;
u) Carrying out all modifications to the given drawings, preparing construction
detailed drawings and supplying originals, copies, and electronic files in
accordance with employer’s requirement.
v) Marine Insurance
w) All risk Insurance after arrival of goods in India
x) Custom clearance / Port Clearance
y) Handling at Port of arrival in India
z) Inland transportation from port of arrival to site of work
aa) Various bank guarantees / warranties/undertakings
1.9 Non-priced Items
1.9.1 Items against which no rate or price is entered by the Tenderer whether quantities
are stated or not, shall be regarded as covered by other rates in the Bills of
Quantities.
1.10 Tender Pricing
1.10.1 The Tenderer shall take regard of the actual site conditions and the estimated
quantities entered in the various bills. The Tenderer shall price his tender
accordingly and the rates and prices entered against a bill line item shall be the full
and only price paid for all work performed against that item except as described in

Volume VII – Pricing Document Page 8 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

the Tender Documents.


1.10.2 The Tenderer shall quote the rates and prices in words as well as in figures in the
summary sheet. Any cutting/overwriting in Bill of Quantities shall be initialled by
the authorized representative of the Tenderer.
1.11 Measurement and Payment
1.11.1 This Contract is primarily a re-measure contract with items that are described
herein. For the re-measure items the total price paid for a work item will be varied
by the quantities actually performed. The contract also contains provisional sum
in BoQ for those Items which are not covered in BoQ and towards quantity/scope
variation and for some unforeseen items like 33 kV cables connectivity between
ISBT/ MR10 flyover RSS and Gandhinagar RSS in the event of delay in
commissioning of Indore Super Corridor GSS..
1.11.2 The measurement and payment described is for the purpose of making a valuation
of the work acceptable to the Engineer, and Interim Payments to the Contractor,
as work proceeds. The Works as executed will be measured for assessment of
progress for interim payments in accordance with the method adopted in the
relevant standard/Specification, the Bills of Quantities and under the items as set
forth notwithstanding any custom to the contrary.
1.11.3 Associated Civil & Building works will be measured as proposed by the Contractor
and accepted and approved by the Employer. For the measurement of “Numbers”
and “Sets” these shall be by count, using dimensions and contents as described in
the specifications and relevant drawings.
1.11.4 For the purposes of making interim payment for line items described as “Set”, the
Contractor shall submit with his tender a breakdown of the rates making up the
total for those items for which the Contractor may wish to receive interim payments.
These breakdowns shall be subject to the approval of the Engineer, and no interim
payment shall be made on such items until the breakdown has been approved.
1.11.5 Notwithstanding anything stated herein, the Engineer retains the right to withhold
payment on any pay item due for payment when the works to be performed are not
performed, or are not carried out to the Engineer’s satisfaction in accordance with
Specifications and Drawings.
1.11.6 Prices so assigned in the BOQ for supply items shall be for the full compensation
for supplying the items in accordance with the approved drawings and
specifications. The Bill items covered by this clause are:

Volume VII – Pricing Document Page 9 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Table 3: Full Compensation Supply Items

SN Bill No. Items Covered

1. IN-1.1, IN-1.2, IN-1.3 A.1.1, A.1.2, A.1.3, A.1.4, A.2.1,


B.1.1, B.1.2,
C.1.1,
D.1,
E.1, E.2,
F.1.1, F.1.2, F.1.3, F.2, F.3, F.4

2. IN-2.1, A.1.1, A.2.1, A.3.1, A.3.2, A.4.1, A.4.2

3. IN-3.1, A.1.1, A.1.2, A.1.3, A.1.4, A.1.5, A.1.6,

4. IN-4.1, A.1.1, A.1.2, A.1.3,


B.1.1, B.1.2, B.1.3, B.1.4,
B.2.1, B.2.2, B.2.3, B.2.4, B.2.5
B.3.1, B.3.2, B.3.3, B.3.4, B.3.5
B.4, B.5
C.1.1, C.1.2, C.1.3, C.1.4, C.1.5
E.1, E.2

5. IN-5.1, A.1.1, A.2.1,


A.3.1, A.3.2, A.3.3, A.3.4
A.4.1,
A.5.1, A.5.2, A.5.3, A.5.4, A.6.1, A.7.1,
A.8.1
B.1.1, B.2.1, B.2.2,
B.3.1, B.3.2
B.4.1, B.4.2
B.5.1, B.5.2

6. IN-6.1, A.1, A.2, A.3, A.4, A.5, A.6, A.7, A.8, A.9.
B.1, B.2, B.3, B.4, B.5, B.6, B.7
C.1, C.2, C.3

7. IN-7.1, A.1.1, A.1.2, A.1.3, A.1.4, A.1.5

Volume VII – Pricing Document Page 10 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

SN Bill No. Items Covered


A.2.1, A.2.2

8. IN-8.1, A.1, A.2, A.3, A.4, A.5, A.6, A.7, A.8, A.9,
A.10, A.11, A.12, A.13.
B.1, B.2, B.3, B.4, B.5, B.6, B.7.
C.1, C.2, C.3, C.4, C.5, C.6.
D.1, D.2, D.3, D.4, D.5, D.6, D.7, D.8, D.9.
E.1, E.2, E.3, E.4, E.5, E.6, E.7, E.8, E.9.
F.1, F.2, F.3, F.4, F.5, F.6, F.7, F.8, F.9.
G.

9 IN-9.1 E.1, F.1, H.1.

1.11.7 Compensation for items covered in Clause 1.11.6 above & Bill No. IN-10, shall
include for all costs incurred in procurement/manufacture, factory testing,
inspection, shipping, hauling, off-loading, storing at site in Indore. Payment will be
made for the items delivered and stored in a place and manner approved by the
Engineer. Payment shall be made on the basis of 80% of the supply price quoted
in the bid on delivery to the Contractor’s respective storage place in Indore and
balance 20% of the supply price after installation, testing, and commissioning in
the depot and/or on the section as certified by the Engineer. Payment on delivery
will be made against the submission of following documents:
a. Certificate of type tests;
b. Certification of Factory Acceptance Tests;
c. Certificate of inspection by the Engineer;
d. Provision of Safe Custody Bank Guarantee;
e. Proof of insurance; and
f. Technical literature and equipment manual.
g. Packing list
1.11.8 NOT USED
1.11.9 Prices so assigned in the BOQ, for erection and commissioning portion of items of
materials, plant and equipment shall be for the full compensation for the installation
/ erection, testing and commissioning of material, plant and equipment in
accordance with the drawings and specifications. Compensation shall include for
all costs incurred for transporting to location, off-loading and moving to point of
installation/erection; provision of specified foundations; preparing for installation /
erection and mounting on foundations; supply of left out items, aligning, fastenings
and securing devices; adjusting as necessary, making good and clearing the

Volume VII – Pricing Document Page 11 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

location on completion, all to the approval of the Engineer. Payment for erection
and commissioning shall be made for 80% of the item on completion of Partial
Acceptance Test of the system. Balance payment of 20% towards erection and
commissioning shall be made when the plant, equipment is tested and
commissioned and become eligible for payment under Clause 1.11.10 below.
1.11.10 Prices for Testing and Commissioning shall be full compensation for the testing
and commissioning of plant and equipment supplied under the Contract in
accordance with the drawings and specifications including integrated testing and
commissioning. Testing and commissioning shall include for all testing and putting-
to-work of all equipment, sub-systems, and systems; re-testing, fault finding,
adjustments and reworking as necessary; submittal of all test reports and other
documents all to the approval of the Engineer. Payment will be made after
certification by the Contractor and acceptance by the Engineer that the sub-
systems and systems, including all equipment have successfully completed the
test procedures, and have been set-to-work and that all test results and other
documentation, as described in the specifications, have been approved by the
Engineer.
1.11.11 Items covered under Civil and Building Works including Electrification [Bill Nos. IN-
10] shall be operated on plinth area pro rata basis. Civil and Building works shall
include but not limited to land and buildings associated with Receiving Sub-Station,
power supply works and other works necessitated by the works under the Contract
and as described in the drawings and specifications. Compensation shall include
for transporting to site; all clearing and grubbing; excavation and removal offsite to
spoil; levelling; local excavation and backfilling to foundations; structural,
architectural, and sundry building works; roof and surface drainage, transformer
drainage, septic tank and effluent filtration system; road works; excavating,
providing and installing cable troughs; excavating and subsequent backfilling of
cable trenches; internal utility services such as water supply, water closets and
wash facilities with outlet connections to septic tank, electrical and communication
systems in each building; landscaping; perimeter fencing and gates; and clearing
the site on completion, all to the approval of the Engineer. Compensation shall
include all necessary attendance upon other trades working in buildings, drilling,
fixing, securing, etc.; sundry excavation and concreting, and generally making
good after other trades. Partial payments will be made for work completed in place
to provide progressive payments as approved by the Engineer.
1.11.12 Prices for training of Employer’s staff shall be pro-rata compensation for the
training of Employer’s staff in different disciplines including training in Metros in
India in accordance with the specifications. Compensation shall include for
preparation, submittal and revisions as required by the Engineer of training
manuals and curricula, employment of approved training staff and all associated
costs and travel costs; provision of all manuals for each training course; provision
and maintenance of training facilities. Payment shall be made at the quoted man-
week rate for each attendee on completion of training. Payment shall be made in
no more than four stages.

Volume VII – Pricing Document Page 12 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

1.11.13 Prices for Manuals and Drawings shall be full compensation for documents and the
like in accordance with the specifications. Compensation shall include for the
preparation, submission, and all subsequent revisions, changes required and re-
submittals as necessary as required by the specifications until accepted by the
Engineer.
a) Review of design and preparation of drawings: Shall include but not be limited
to review of design, documents, drawings, calculations as issued by the
Employer to the Contractor, other drawings to be prepared by the Contractor
as specified in the Particular specification for approval of the Engineer as
required by construction at site. This will also include shop drawings
containing the information related to Permanent Works.
b) Operation and Maintenance Manuals: Shall include but not be limited to
preparation and revision of Operation and Maintenance Manuals as specified
in Employer requirements (Vol-III) & Technical specifications (Vol-IV)
pertaining to all equipments / systems / subsystems which have been used /
deployed in the Project.
c) As built drawings: Shall include but not be limited to supply of as built drawings
of all equipments / systems / subsystems in the Permanent Work constructed
under this Contract. Payment shall be made when all the As-Built drawings
for each discipline have been reviewed and accepted by the Engineer.
1.11.14 Prices for Maintenance Supervision during Defect Notification Period (DNP) shall
be pro-rata compensation for the supervision by the Contractor of the Employer’s
maintenance staff in different disciplines in accordance with the specifications.
Compensation shall include for the approval of the supervisors and replacement
as required by the Employer, employment of approved staff including salaries,
overtime, airfares, lodging allowances, their office expenditure, telephones / mobile
bills, local travel costs to and from site, training materials, income tax and other
taxes deducted at source. Payment shall be made at the quoted man-month rate
for each approved supervisor who is at site. Payment shall be made in no more
than four stages.
1.11.15 Prices for Integrated Testing and Commissioning shall be full compensation for the
integrated testing and commissioning of plant and equipment supplied under the
Contract in accordance with the drawings and specifications. Compensation shall
include for preparation, submittal, and revisions as required by the Engineer of
testing plans and procedures; co-ordination with other Designated Contractors;
conduct of approved tests as directed by the Engineer on equipment, sub-systems,
and systems; revisions, re-testing, fault finding, adjustments and reworking as
necessary; submittal of all test reports and other documents all to the approval of
the Engineer. 80% Payment will be made for each Section (refer to Table 1.3 of
Chapter-1 of TS, Vol-IV) after certification by the Contractor and acceptance of the
Engineer that the sub-systems and systems, including all equipment have
successfully completed the test procedures, and have been set-to-work and
submission of all test results and other documentation, as described in the
specifications. Balance 20% of each Section shall be released after completion of

Volume VII – Pricing Document Page 13 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

all Sections and integration of the entire Works under this Contract.
1.11.16 Prices for Tools and Plant shall be full compensation for supplying all tools, special
tools and special test instruments and equipment in accordance with the
specifications as per supply schedule described in Chapter-9 of TS. Compensation
shall include provision of tools etc., as required by the specifications, complete in
every respect with operating instructions as necessary. Payment shall be made
when all tools have been delivered to the Employer and accepted by the Engineer.
Full payment shall be made on completion of supply for each stage.
1.11.17 Prices for spares shall be full compensation for supplying the spare parts for the
equipment, sub-systems, and systems provided under the Contract in accordance
with the specifications as per supply schedule described in Chapter-9 of TS.
Compensation shall include provision of spare parts and lists as required by the
specifications, complete in every respect, fully catalogued and marked for
identification purposes for each discipline and to the approval of the Engineer.
Payment shall be made when all spare parts and associated documentation have
been delivered to the Employer and accepted by the Engineer. Full payment shall
be made on completion of supply for each stage.
1.11.18 Compensation for Employer’s Facilities shall include all costs incurred in provision
of Principal Office, site office, furniture, office equipment and support staff as
described in Chapter-5 of TS. Payment shall be made on the basis of 60% on
delivery of all these facilities and balance 40% after the completion of Defect
Notification Period.

Volume VII – Pricing Document Page 14 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

2. Explanatory Notes To Bill Of Quantities (“BOQ”)


2.1 General
2.1.1 The item description is intended to briefly describe the work to be performed under
that item and to identify associated work. It is not a full and complete description
of the work to be performed. The Contractor shall carry out all the work necessary
to meet the requirements of the Specification.
2.2 132 kV / 33kV Receiving SUBSTATIONS
2.2.1 The Bill of Quantity for RSS at Gandhi Nagar Depot, ISBT/MR10 Flyover, Khajrana
Square, is presented in BOQ Bill Nos. IN-1.1, IN-1.2, IN-1.3 respectively. For
detailed specifications, the Chapter 12 of TS Vol-IV shall be referred to.
2.2.2 Following notes are explanation of the items under these Bill Nos.:

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description

A 132 KV BAYS (AIS)

A.1 132 kV Switchgear BOQ Bill Nos.


IN-1.1,

A.1.1 Supply and erection Supply:


including testing and
o Triple pole incoming circuit breaker
commissioning of
incoming Circuit o Lightning arrestor in each of three phases
Breaker Bay o Triple Pole Line Isolator with Earthing isolator
to earth incoming cable
o Two Voltage transformers in each phase
o Two Current transformers in each phase
o Two Triple pole motor operated isolator
o Structures to support the equipment including
support insulator
o Fittings, terminals & other components for
completion of bay
o Rigid Bus, connectors, terminations, jumpers
& connectors with steel structures etc. to
mount and support the equipment
o Tariff Metering Equipment’s as per PSA
requirements
Erection & Commissioning:
o Erection of all above equipment

Volume VII – Pricing Document Page 15 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
o Testing & commissioning of all above
equipment’s

A.1.2 Supply and erection Supply:


including testing and
o Triple pole gang operated incoming circuit
commissioning of
breaker
coupling Circuit
Breaker Bay o Two Voltage transformers in each phase
o Two Current transformers in each phase
o Two Triple pole motor operated isolator
o Rigid Bus, terminations, jumpers &
connectors with steel structures etc. to mount
and support the equipment
o Support Structures to mount and support the
equipment including support insulator
o Aluminum rigid bus, tubular/gantry structures
o Fittings, terminals & other components,
including high post insulators for completion
of bay
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.3 Supply and erection Supply:


including testing and
o Triple pole incoming circuit breaker
commissioning of
transformer feeding o Lightning arrestor in each of three phases
Circuit Breaker Bay o Current transformer in each phase
o One Triple pole motor operated isolator
o Rigid Bus, connectors, terminations, jumpers
&connectors with steel structures etc. to
mount and support the equipment including
support insulator.
o Fittings, terminals & other components for
completion of bay
Erection & Commissioning:

Volume VII – Pricing Document Page 16 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.4 Supply and erection Supply:


including testing and
o Rigid Bus, connectors, terminations, jumpers
commissioning
& connectors with steel structures, gantry etc.
Steel structure &
to mount and support the equipment
Busbars

Erection & Commissioning:


o Erection of all above equipment
Testing & commissioning of all above
equipment’s

A.1 132 KV GIS BOQ Bill Nos.


IN-1.2 & IN-1.3-GIS RSS

A.1.1 Supply, erection, Supply:


testing and
o Supply of 132KV SF6 Gas insulated
commissioning of
incoming feeder Bay each comprising of
incoming Circuit
SF6 gas insulated circuit breaker, current
Breaker Bay
Transformer, PT modules ,Two bus bar
disconnectors with grounding switch, line
disconnector with safety grounding switch,
high speed fault making grounding
switch,SF6 gas monitoring system for
complete bay, LCC, Cable termination,SF6 to
Air bushings and Accessories with GIS etc,
with complete incoming feeder bay module
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment

A.1.2 Supply, erection, Supply:


testing and
o Supply of 132 KV SF6 Gas insulated Bus
commissioning of
coupler Bay each comprising of SF6 gas
Bus coupler Bay
insulated circuit breaker, current
Transformers ,Bus PT modules, Two bus bar

Volume VII – Pricing Document Page 17 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
disconnectors with grounding switch,SF6 gas
monitoring system for complete bay, LCC,
Accessories with GIS etc,

Erection & Commissioning:


o Erection of all above equipment
o Testing & commissioning of all above
equipment

A.1.3 Supply, erection, Supply:


testing and
o Supply of 132 KV SF6 Gas insulated
commissioning of
transformer Bay each comprising of
transformer feeding
SF6 gas insulated circuit breaker,
Circuit Breaker Bay
current Transformer, Two bus bar
disconnectors with grounding switch,
SF6 gas monitoring system for complete
bay, LCC, Cable termination, SF6 to Air
bushings and Accessories with GIS etc,
with complete transformer bay module
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment

A.1.4 Supply and Supply:


Erection including
o 5 Ton EOT Crane including all
testing and
associated accessories and fixtures.
commissioning of
other items for GIS o Lightning arrestor including all
associated accessories and fixtures.
o 132 kV Post insulator with all
associated accessories and
connectors.
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment

Volume VII – Pricing Document Page 18 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description

A.2 Control & Relay BOQ Bill Nos.


Panel
IN-1.1, IN-1.2, IN-1.3

A .2.1 Supply and erection Supply:


including testing and
o Control & protection cubicle
commissioning of
Control & Relay o Numerical protection relays for incoming
Panel for 132 KV bays
Bays o Numerical protection relays for bus coupler
bay
o Numerical protection relays for transformer
feeding bays
o Numerical protection for bus bar protection
o Energy Metering for incoming bays
o Transducers, Auxiliary relays, cables,
terminal, fuses and all other components for
completion of panel.
Erection & Commissioning:
o Erection of all above equipment
o Laying power and control cable
o Testing & commissioning of all above
equipment’s
NOTE: -
Payments for control cables shall be covered in
D.1 schedule

B.1 Transformer BOQ Bill Nos.


IN-1.1, IN-1.2, IN-1.3

B.1.1 Supply and erection Supply:


including testing and
o Power transformer along with OLTC and
commissioning of
forced cooling arrangement
132 KV/33 KV,
30/40 MVA Power o Secondary neutral earthing system along
transformer with Neutral Grounding Resistor, CTs, LAs,
isolators
o Nitrogen Injection Fire Protection System

Volume VII – Pricing Document Page 19 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
including all accessories
o Current transformer for tank protection
o Mounting rails and oil retaining materials and
equipment
o RTCC Panel including Automatic voltage
regulator
o Fittings & other components for completion of
Power Transformer
Erection & Commissioning:
o Erection of all above equipment
o Laying power and control cable
o Testing & commissioning of all above
equipment’s including oil filtration

B.1.2 Supply and erection Supply:


including testing and
o Auxiliary transformer along with enclosure
commissioning of 33
KV/ 415V, 200 KVA o Neutral CT
Auxiliary Station o Protection CTs
transformer, 40 KVA
Lighting transformer o Mounting rails
o Temperature sensor, alarm and trip modules
o Fire protection system
o Fittings & other components for completion of
job
o Lighting Transformer along with all
accessories
Erection & Commissioning:
o Erection of all above equipment
o Laying power and control cable
o Testing & commissioning of all above
equipment’s

C 33 KV SWG PANEL BOQ Bill Nos. IN-1.1

C.1 33 kV SWG Panel

Volume VII – Pricing Document Page 20 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description

C.1.1 Supply and erection Supply:


including testing and
o 11 panel board of 33 KV Vacuum switchgear
commissioning of a
consisting of two incomers, one bus coupler
set of 11 panel
including adopter, two bus PTs and Six
board of 33 KV
feeders.
Vacuum switchgear
consisting of two o Bus riser panel
incomers, one bus o Protection relays as per specification
coupler including
adopter, two bus o CTs, PTs as per specifications
PTs and Six o Energy Meters at the incomers
feeders.
o Mounting channels if required
o Fire protection system
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Erection of all above equipment
o Laying power and control cable
o Testing & commissioning of all above
equipment’s

C 33 KV SWG PANEL BOQ Bill Nos. IN-1.2, IN-1.3

C.1.1 Supply and erection Supply:


including testing and
9 panel board of 33 KV Vacuum switchgear
commissioning of a
consisting of two incomers, one bus coupler
set of 9 panel board
including adopter, two bus PTs and Four
of 33 KV Vacuum
feeders
switchgear
consisting of two o Bus riser panel
incomers, one bus o Protection relays as per specification
coupler including
adopter, two bus o CTs, PTs as per specifications
PTs and Four o Energy Meters at the incomers
feeders
o Mounting channels if required
o Fire protection system

o Padlocks, Fittings & other components for


completion of Job

Volume VII – Pricing Document Page 21 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description

Erection & Commissioning:


o Erection of all above equipment
o Laying power and control cable
o Testing & commissioning of all above
equipment’s

D LV & Control BOQ Bill Nos.


Cables
IN -1.1, IN -1.2, IN -1.3

D.1 Supply, laying, Supply:


testing and
o LV control (inclusive of optical fiber cable)
commissioning of
and power cables of suitable cross section for
LV Control &
entire RSS including the cables from yard to
associated power
control room, among the equipment’s, CRP
cables including
Panel connection, RTU connection cables
optical fibre cable
etc.
(OFC)
o Termination lugs, glands, ferrules, ties,
markers etc.
Erection & Commissioning:
o Laying of cable, erection of accessories and
all components as indicated above
o Testing & commissioning of cable &
accessories

E EARTHING BOQ Bill Nos.


IN -1.1, IN -1.2, IN -1.3

E.1 Supply, laying and Supply:


Connections of
o MS round rod for yard earth mat
Earth Mat to achieve
the resistance value o Earth risers
described in Vol-IV o Interconnection cable from yard earth mat to
of Chapter-12 control room earth mat and other structures
o Other components for completion of Job
Erection & Commissioning:
o Design of earth mat

Volume VII – Pricing Document Page 22 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
o Laying of earth mat as per approved design
o Laying of earth risers as per approved design
o Laying of interconnections, welding/brazing
etc.
o Testing & commissioning of earth mat

E.2 Supply, laying and Supply:


Connections of
o connection to equipment
50X6 GI Strip for
connections of o Welding/brazing etc.
equipment with o Clamps and Other components for
Earth mat completion of Job
Erection & Commissioning:
o Laying of GI strip along with accessories
o Connection to equipment, Testing &
commissioning of earth system

F AUXILIARIES BOQ Bill Nos.


IN -1.1, IN -1.2, IN -1.3

F.1 Supply and erection Supply:


including testing and
o Two set of 110 V battery banks as per
commissioning of
specification
Battery & Battery
Chargers o One set of battery chargers, comprising of in
all 3 Battery Chargers as per specification
o One set of UPS along with battery bank as
per specification
o Mounting rack for battery, protection and
connections.
o Other components for completion of Job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

F.2 Supply and erection Supply:


including testing and
o Three cabinets each containing a Master

Volume VII – Pricing Document Page 23 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
commissioning of circuit breaker
ACDB
o Copper bus bar as per specification
o Protection circuit breakers
o Outgoing feeders with MCBs
o Locks, interlocks and other components for
completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

F.3 Supply and erection Supply:


including testing and
o Two cabinets each containing a Master
commissioning of
circuit breaker
DCDB
o Isolating switch, non-return diodes
o Copper bus bar as per specification
o Over current and under voltage protection
relays
o Outgoing feeders with MCBs
o Automatic and normal device for changeover
o Locks, interlocks and other components for
completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

F.4 Supply and erection Supply:


of Safety Equipment
o All safety equipment’s like Rubber mat of
including yard
6mm thickness, hand gloves, CO2 fire
extinguisher, fire bucket, First aid box etc.
o Laminated SLD on sun board/Hard board
o Lockable key board
o Fire detection and alarm system for RSS

Volume VII – Pricing Document Page 24 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

BOQ Item
Item No. Explanation BOQ Bill Nos.
Description
o Locks, and other components for completion
of job
Erection & Commissioning:
o Installation & placement of above
equipment’s
o Testing & commissioning of above
equipment’s if required

G RSS Manning BOQ Bill Nos.


IN -1.1, IN -1.2, IN -1.3

G.1 Skilled Supervisor Provision of skilled supervisor as per


specification.

G.2 Skilled Worker Provision of skilled worker as per specification.

G.3 Unskilled Worker Provision of skilled unskilled worker as per


specification.

2.3 33 kV Cables
2.3.1 The Bill of Quantity for Yellow Line of 33 KV HT Cables is presented in BOQ Bill
Nos. IN-2.1. For detailed specifications chapter 13 of TS Vol-IV shall be referred
to.
2.3.2 Following notes are explanation of the items under these Bill Nos.:

Explanation
Item No. BOQ Item Description
BOQ Bill Nos. IN -2.1,

A 33 KV CABLES

A.1 Power Tr. Secondary


to 33kV Swgr I/C at
RSS

A.1.1 Supply, laying, Supply:


termination, testing and
o 33KV Cable as per specification, Power Tr.
commissioning of 33 kV
Secondary to 33kV Swgr I/C at RSS
Cables and
connections. From o 33 KV Cable consists of 3 cables for one
Power Tr. secondary to circuit
incomer of 33kV o Control cables for protection and

Volume VII – Pricing Document Page 25 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation
Item No. BOQ Item Description
BOQ Bill Nos. IN -2.1,
Switchgear interlocking including glands and copper
lugs
o Straight Through Joint kit for all phases
o Termination kit for all phases
o HDPE/GI Pipe, Sand, RCC slabs, warning
tape
o Route markers, warning tapes and boards
o Any mounting arrangement, G I Structures
o HDPE Pipe and clamps
o Other components like Cables Brackets,
Channel, angles etc. for completion of Job
Erection & Commissioning:
o Construction of open trenches, trenchless
drilling, laying of HDPE pipes and other
activities required for laying of cables
o Laying of cable, erection of accessories
and all components as indicated above
o Appropriate sealing of cutout as per
specifications and drawings
o Testing & commissioning of cable &
accessories

A.2 RSS To ASS/TSS


BOQ Bill Nos. IN -2.1,
Feeder

A.2.1 Supply, laying, Supply:


termination, testing and
o 33KV Cable as per specification in the 33
commissioning of 33kV,
KV ring circuit among various ASS /TSS
Cable connections from
33 KV CB in RSS to o 33 KV Cable ring inside the depots for
incoming CB in ASS & feeding depot ASS & TSS
TSS at viaduct including o 33 KV interconnecting Cables at Pul Bogda
the rings inside Depot for feeding ASS/TSS of other corridor.
Sub-Stations
o 33 KV Cable consists of 3 cables for one
circuit.
o Control cables for protection and
interlocking including glands and copper

Volume VII – Pricing Document Page 26 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation
Item No. BOQ Item Description
BOQ Bill Nos. IN -2.1,
lugs.
o Heat shrinkable Termination kit for all
phases
o Heat Shrinkable Straight Through Joints for
all phases
o Barricades, bridges over nallah
o HDPE/GI Pipe, Sand, RCC slabs, warning
tape
o Route markers, warning tape and boards
o Mounting arrangement on panel end
o Other components like Trefoil clamps,
Heavy duty lugs, Cable Brackets on
Viaduct and Platform, Anchor Fasteners,
Channel, angles, phase marking/Tags etc.
for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories
and all other components as indicated
above
o Cable sealing arrangement as per
specification
o Appropriate sealing of cutout as per
specifications and drawings
o Testing & commissioning of cable &
accessories

A.3 Ring Cables at


BOQ Bill Nos. IN -2.1,
Elevated/Underground

A.3.1 Supply, laying, Supply:


termination, testing and
o 33KV Cable as per specification in the 33
commissioning of 33 kV
KV ring circuit among various ASS /TSS
Cables and
connections. Ring main o 33 KV interconnecting Cables at Pul Bogda
between ASS and TSS for feeding ASS/TSS of other corridor.
station for o 33 KV Cable consists of 3 cables for one
elevated/underground circuit.

Volume VII – Pricing Document Page 27 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation
Item No. BOQ Item Description
BOQ Bill Nos. IN -2.1,
o Control cables for protection and
interlocking including glands and copper
lugs.
o Heat shrinkable Termination kit for all
phases
o Heat Shrinkable Straight Through Joints for
all phases
o Mounting arrangement on panel end
o Other components like Trefoil clamps,
Heavy duty lugs, Cable Brackets on
Viaduct and Platform, Anchor Fasteners,
Channel, angles, phase marking/Tags etc.
for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories
and all other components as indicated
above
o Appropriate sealing of cutout as per
specifications and drawings
o Testing & commissioning of cable &
accessories

A.3.2 Supply, laying, testing Same as above item except that cables and
and commissioning of joint / termination kits shall be FRLSOH type
33 kV Cables and for underground sections instead of FRLS
connections for type
ASS/TSS for
underground sections

A.4 TRANSFORMER CONNECTION

A.4.1 Supply, laying, Supply:


termination, testing and
o 33KV Cable as per specification for
commissioning of 33 kV
connection from Power Transformer to 33
Cables and connections
KV CB in RSS
from 33 kV CB to
Aux./Rectifier o 33KV Cable as per specification for
transformer for connection from 33 KV CB to Aux
elevated/ at grade Transformer in RSS & ASS

Volume VII – Pricing Document Page 28 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation
Item No. BOQ Item Description
BOQ Bill Nos. IN -2.1,
o 33KV Cable as per specification for
connection from 33 KV CB to Traction
Transformer in TSS
o 33 KV Cable consists of 3 cables for one
circuit
o Termination kit for all phases.
o Mounting arrangement on CB end and
transformer end
o Cable support arrangements, GI Structures
o Other components like Cables Brackets,
Channel, angles etc. for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories
and all components as indicated above
o Testing & commissioning of cable &
accessories

A.4.2 Supply, laying, testing Same as above item except that cables and
and commissioning of joint / termination kits shall be FRLSOH type
33kV Cables and for underground sections instead of FRLS
connections from 33 kV type.
CB to Transformer for
underground sections

2.4 33kV Switchgear


2.4.1 The Bill of Quantity for Yellow Line is presented in BOQ Bill no: IN-3.1. For detailed
specifications chapter 14 of TS Vol – IV shall be referred to following notes are
explanation of the items under these Bill Nos.:

Explanation 33 kV Switchgear
Item No. BOQ Item Description
BOQ Bill Nos. IN -3.1

A.1 33 KV SWITCHGEAR Panels

A.1.1 Supply and erection Supply and erection including testing and
including testing and commissioning of Three panel boards of
commissioning of a set Vacuum CBs
of three panel boards Supply:
o 3 panels, 3 pole 33 kV switchboard

Volume VII – Pricing Document Page 29 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation 33 kV Switchgear
Item No. BOQ Item Description
BOQ Bill Nos. IN -3.1
consisting of one incoming, one outgoing
and one Aux. Transformer feeder Vacuum
circuit breaker
o Protection relays as per specification
o CTs, PTs as per specifications
o Mounting channels/Support, if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers.

Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.2 Supply and erection Supply and erection including testing and
including testing and commissioning of four panel boards of
commissioning of a set Vacuum CBs
of four panel boards
Supply:
o 4Panels, 3 pole 33 kV switchboard
consisting of one incoming, one outgoing
and two Aux. Transformer feeder Vacuum
circuit breaker
o Protection relays as per specification
o CTs, PTs as per specifications
o Mounting channels if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers
Erection:

Volume VII – Pricing Document Page 30 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation 33 kV Switchgear
Item No. BOQ Item Description
BOQ Bill Nos. IN -3.1
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.3 Supply and erection Supply and erection including testing and
including testing and commissioning of Six panel boards of Vacuum
commissioning of a set CBs
of Six panel boards
Supply:
o 6 panels, 3 pole 33 kV switchboard
consisting of one incoming, Two outgoing,
for other ASS/TSS on the station and three
Transformer feeder Vacuum circuit breaker
o Protection relays as per specification
o CTs, PTs as per specifications
o Mounting channels if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.4 Supply and erection Supply and erection including testing and
including testing and commissioning of nine panel boards of
commissioning of a set Vacuum CBs
of Nine panel boards
Supply:
o 9 panels, 3 pole 33 kV switchboard
consisting of two incoming, two outgoing,
two Aux. Transformer feeder, two traction
transformer and one bus coupler Vacuum
circuit breaker
o Protection relays as per specification
o CTs, PTs as per specifications

Volume VII – Pricing Document Page 31 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation 33 kV Switchgear
Item No. BOQ Item Description
BOQ Bill Nos. IN -3.1
o Mounting channels if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.5 Supply and erection Supply and erection including testing and
including testing and commissioning of Eleven panel boards of
commissioning of a set Vacuum CBs
of Eleven panel boards
Supply:
o 11 panels, 3 pole 33 kV switchboard
consisting of Two incomer from RSS, two
incoming, two outgoing for ring circuit, two
Aux. Transformer feeder, two future CBs
and one bus coupler Vacuum circuit breaker
o Protection relays as per specification
o CTs, PTs as per specifications
o Mounting channels if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.6 Supply and erection Supply and erection including testing and
including testing and commissioning of one panel boards of
commissioning of a set Vacuum CBs
of One panel board
Supply:
between Inverter

Volume VII – Pricing Document Page 32 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation 33 kV Switchgear
Item No. BOQ Item Description
BOQ Bill Nos. IN -3.1
transformer to 33KV o 1 panel, 3 pole 33 kV VCB
Supply
o Protection relays as per specification
o CTs, PTs as per specifications
o Mounting channels if required
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
o CB withdrawal Trolley two numbers
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

2.5 Auxiliary Substations


2.5.1 The Bill of Quantity for Yellow Line is presented in BOQ Bill Nos. IN-4.1 . For
detailed specifications, the Chapter 14 of TS Vol-IV shall be referred to.
2.5.2 Following notes are explanation of the items under these Bill Nos.

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1

A.1 33 KV / 415 V TRANSFORMER

A.1.1 Supply and erection Supply and erection including testing and
including testing and commissioning of 33kV/415V, 500kVA Dry Type
commissioning of Transformers
33kV/415V, 500kVA
Supply:
Dry Type
Transformers o Auxiliary transformer along with enclosure
o Neutral CT
o Mounting rails
o Temperature sensor, alarm and trip modules
o Fire protection system as per Specifications
o Fittings & other components for completion of
job

Volume VII – Pricing Document Page 33 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.2 Supply and erection Supply and erection including testing and
including testing and commissioning of 33kV/415V, 2500 kVA Dry
commissioning of Type Transformers
33kV/415V, 2500 kVA
Supply:
Dry Type
Transformers o Auxiliary transformer along with enclosure
o Neutral CT
o Mounting rails
o Temperature sensor, alarm and trip modules
o Fire protection system as per Specifications
o Fittings & other components for completion of
job
Erection:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.1.3 Supply and erection Supply and erection including testing and
including testing and commissioning of 33kV/415V, 2000kVA Dry
commissioning of Type Transformers with forced Ventilation.
33kV/415V, 2000 kVA
Supply:
Dry Type
Transformers in Depot o Auxiliary transformer along with enclosure
ASS1. o Neutral CT
o Mounting rails
o Temperature sensor, alarm and trip modules
o Fire protection system as per Specifications
o Fittings & other components for completion of
job
Erection:
o Erection of all above equipment

Volume VII – Pricing Document Page 34 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Testing & commissioning of all above
equipment’s

B AUXILIARIES

B.1 BATTERY & BATTERY CHARGER

B.1.1 & Supply and erection Supply:


B.1.2 including testing and
o Battery and battery chargers for at
commissioning of
grade/elevated corridor substation with ASS
Battery & Battery
only, underground substations with ASS only
Chargers (Type – 1
and depot substations with ASS only.
system)
o One set of 110 V battery banks (min 180 AH)
as per specification
o One set of battery chargers, comprising of 2
Battery Chargers as per specification
o Mounting rack for battery, protection and
connections.
o Other components for completion of Job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.1.3 & Supply and erection Supply:


B1.4 including testing and
o Battery and battery chargers for elevated / at-
commissioning of
grade and underground corridor with ASS &
Battery & Battery
TSS.
Chargers (Type – 2
system) o One set of 110 V battery banks (min 300 AH)
as per specification
o One set of battery chargers, comprising of 2
Battery Chargers as per specification
o Mounting rack for battery, protection and
connections.
o Other components for completion of Job
Erection & Commissioning:

Volume VII – Pricing Document Page 35 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.2 ACDB

B.2.1 Supply and erection Supply:


including testing and
o ACDB for underground substation with one
commissioning of
ASS only
ACDB (type 1)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
Testing & commissioning of above equipment’s

B.2.2 Supply and erection Supply:


including testing and
o ACDB for underground substation with one
commissioning of
ASS & one TSS only
ACDB (type 2)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.2.3 Supply and erection Supply:


including testing and
o ACDB for at grade/elevated corridor
commissioning of
substation, depot substation with ASS only
ACDB (type 3)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars

Volume VII – Pricing Document Page 36 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.2.4 Supply and erection Supply:


including testing and
o ACDB for at grade/elevated corridor
commissioning of
substation with ASS and one TSS only
ACDB (type 4)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.2.5 Supply and erection Supply:


including testing and
o ACDB for depot/elevated substation with one
commissioning of
TSS only
ACDB (type 5)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.3 DCDB

Volume VII – Pricing Document Page 37 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1

B.3.1 Supply and erection Supply:


including testing and
o DCDB for underground substation with one
commissioning of
ASS only
DCDB (type 1)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
Testing & commissioning of above equipment’s

B.3.2 Supply and erection Supply:


including testing and
o DCDB for underground substation with one
commissioning of
ASS & one TSS only
DCDB (type 2)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.3.3 Supply and erection Supply:


including testing and
o DCDB for at grade/elevated corridor
commissioning of
substation, depot substation with ASS only
DCDB (type 3)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:

Volume VII – Pricing Document Page 38 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.3.4 Supply and erection Supply:


including testing and
o DCDB for at grade/elevated corridor
commissioning of
substation with ASS and one TSS only
DCDB (type 4)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.3.5 Supply and erection Supply:


including testing and
o DCDB for depot/elevated substation with one
commissioning of
TSS only
DCDB (type 5)
o Single cabinet containing incoming MCB,
outgoing MCB, fuses, copper bus bars
o Auxiliary contactors, indication lamps
o Mounting arrangement and other
components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s

B.4 Supply and erection of Supply:


Safety Equipment
o All safety equipment’s like Rubber mat of
thickness 6mm, hand gloves, CO2 fire
extinguisher, fire bucket, First aid box etc.
o Lockable key board
o Locks, and other components for completion

Volume VII – Pricing Document Page 39 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
of job
Erection & Commissioning:
o Installation & placement of above
equipment’s
o Testing & commissioning of above
equipment’s if required

B.5 Supply and erection Supply:


including testing and
o ETS Box as per specification
commissioning of ETS
o Other components for completion of job
Erection & Commissioning:
o Erection of above equipment’s
o Testing & commissioning of above
equipment’s
Note:
o The SCADA & power cable supply, laying and
connection shall be covered under LV
Cables.

C CABLES

C.1 LV Power & Control


Cables

C.1.1 Supply, laying, testing Supply:


and commissioning of
o LV & control Cables for underground station
LV Cables for Type 1
with one ASS only
SS
o LV control and power cable, OFC cables of
required sizes forinter connecting all
equipment’s in ASS/TSS including the cables
for RTU, ETS and among the equipment,
Disconnection switches and track
equipment’s for complete commissioning of
Sub-station
o Termination lugs, glands, ferrules, cable ties,
markers etc.
Erection & Commissioning:

Volume VII – Pricing Document Page 40 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Laying of cable, erection of accessories and
all components as indicated above
Testing & commissioning of cable & accessories

C.1.2 Supply, laying, testing Supply:


and commissioning of
o LV Cables for underground station with one
LV Cables for Type 2
ASS & one TSS only
SS
o LV control and power cable, OFC cables of
required sizes for interconnecting all
equipment’s in ASS/TSS including the cables
for RTU, ETS and among the equipment,
Disconnection switches and track
equipment’s for complete commissioning of
Sub-station
o Termination lugs, glands, ferrules, cable ties,
markers etc.
Erection & Commissioning:
o Laying of cable, erection of accessories and
all components as indicated above
o Testing & commissioning of cable &
accessories

C.1.3 Supply, laying, testing Supply:


and commissioning of
o LV Cables for at grade/elevated corridor
LV Cables for Type 3
station, with ASS only
SS
o LV control and power cable, OFC cables of
required sizes for interconnecting all
equipment’s in ASS/TSS including the cables
for RTU, ETS and among the equipment,
Disconnection switches and track
equipment’s for complete commissioning of
Sub-station.
o Termination lugs, glands, ferrules, cable ties,
markers etc.
Erection & Commissioning:
o Laying of cable, erection of accessories and
all components as indicated above

Volume VII – Pricing Document Page 41 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o Testing & commissioning of cable &
accessories

C.1.4 Supply, laying, testing Supply:


and commissioning of
o LV Power & Control Cables for at
LV Cables for Type 4
grade/elevated corridor station with ASS and
SS
one TSS only
o LV control and power cable, OFC cables of
required sizes for interconnecting all
equipment’s in ASS/TSS including the cables
for RTU, ETS and among the equipment,
Disconnection switches and track
equipment’s for complete commissioning of
Sub-station.
o Termination lugs, glands, ferrules, cable ties,
markers etc.
Erection & Commissioning:
o Laying of cable, erection of accessories and
all components as indicated above
o Testing & commissioning of cable &
accessories

C.1.5 Supply, laying, testing Supply:


and commissioning of
o LV Power & Control Cables for depot TSS
LV Cables for Type 5
only
SS
o LV control and power cable, OFC cables of
required sizes for interconnecting all
equipment’s in ASS/TSS including the cables
for RTU, ETS and among the equipment,
Disconnection switches and track
equipment’s for complete commissioning of
Sub-station.
o Termination lugs, glands, ferrules, cable ties,
markers etc.
Erection & Commissioning:
o Laying of cable, erection of accessories and
all components as indicated above
o Testing & commissioning of cable &

Volume VII – Pricing Document Page 42 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
accessories

D SS MANNING

D.1 Skilled Supervisor Provision of skilled supervisor as per


specification.

D.2 Skilled worker Provision of skilled worker as per specification.

D.3 Unskilled worker Provision of unskilled worker as per


specification.

E`.1 Transformer to LV LV Bus Duct for 2000 KVA Auxiliary


Panel Connection Transformer to LV Panel
Supply:
LV Bus duct o TP, 3200 A, indoor sandwich type aluminum
bus duct as per specification.
o Earth bus connection strip as per
specification
o All hardware, connection pieces, horizontal /
vertical bends etc., as required
o Aluminum laminated flexible joint as required
o Flexible termination at both ends with
aluminum lamination per TPN set
o Support arrangement from ceiling walls etc.
o Mounting channels if required
Erection & Commissioning:
o Erection of all above equipment including
terminations at both ends
Testing & commissioning of all above
equipment

E.2 LV Cable connections LV Cable connections– Auxiliary Transformer to


LV Panel
Supply:
o 300 SQMM ,2 run for 500KVA trf; Aluminium
Cables connections for Phase & 1 run for
Neutral as per specification

Volume VII – Pricing Document Page 43 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item BOQ Item Explanation - Auxiliary Substations


No. Description BOQ Bill Nos. IN-4.1
o All hardware, connection pieces, horizontal /
vertical bends etc., as required
o Termination at both ends
o Support arrangement from ceiling walls etc.
o Mounting channels if required

Erection & Commissioning:


o Erection of all above equipment including
terminations at both ends
o Testing & commissioning of all above
equipment

2.6 Traction Substations


2.6.1 The Bill of Quantity for Purple and Red Line is presented in BOQ Bill Nos. IN-5.1.
For detailed specifications, the Chapter 15 of TS Vol-IV shall be referred to.
2.6.2 Following notes are explanation of the items under these Bill Nos.:

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1

A.1 33 KV / 585-585 V TRACTION TRANSFORMER

A.1.1 Supply and erection Supply:


including testing and
o Traction transformer along with enclosure
commissioning of
33kV/585-585 V, 2850 o Mounting rails
kVA Dry Type o Temperature sensor, alarm and trip modules
Transformers
o Fire protection system as per Specifications
o Fittings & other components for completion of
job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.2 RECTIFIER

Volume VII – Pricing Document Page 44 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1

A.2.1 Supply and erection Supply:


including testing and
o Rectifier along with enclosure
commissioning of
Rectifier, 2.5 MW o Mounting rails
o Temperature sensor, alarm and trip modules
o Fire protection system as per Specifications
o Fittings & other components for completion of
job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.3 HSCB

A.3.1 Supply and erection Supply:


including testing and
o 6 panel, 1 pole 900 V DC switchboard
commissioning of six
consisting of two incomer circuit breaker, four
panel boards HSCB
third rail feeding circuit breaker
with two incomer and
four Outgoing feeders o Protection relays as per specification
o Current and Voltage sensor as per
specifications
o Elevated platform structure for mounting of
HSCB
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Construction of raised platform for mounting of
switchboard in at grade/elevated corridor
stations
o Erection of all above equipment
o Testing& commissioning of all above
equipment’s

A.3.2 Supply and erection Supply:

Volume VII – Pricing Document Page 45 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1
including testing and o 8 panel, 1 pole 900 V DC switchboard
commissioning of Eight consisting of two incomer circuit breaker, four
panel boards HSCB third rail feeding circuit breaker, two stinger
including two incomers feeding circuit breaker
and six outgoing
o Current and Voltage sensor per specifications
feeders
o Elevated platform structure for mounting of
Switches
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Construction of raised platform for mounting of
switchboard in at grade/elevated corridor
stations
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.3.3 Supply and erection Supply:


including testing and
2 panel, 1 pole 900 V DC switchboard
commissioning of
consisting of two DC load break switches and
Bypass Coupling Panel
Motorized isolator suitable for 750 V DC supply
with two load break
along with mounting insulators
switches and four
motorized Isolators o Current and Voltage as per specifications
o Elevated platform structure for mounting of
Switches
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Construction of raised platform for mounting of
switchboard in at grade/elevated corridor
stations
o Erection of all above equipment
o Testing & commissioning of all above

Volume VII – Pricing Document Page 46 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1
equipment’s

A.3.4 Supply and erection Supply:


including testing and
1 panel, 1 pole 900 V DC switchboard
commissioning of one
consisting of two DC load break switches and
panel board HSCB
Motorized isolator suitable for 750 V DC supply
feeders for 750V DC
along with mounting insulators
busbar in Inverter Ckt.
o Current and Voltage sensors as per
specifications
o Elevated platform structure for mounting of
Switches
o Fire protection system as per Specifications
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Construction of raised platform for mounting of
switchboard in at grade/elevated corridor
stations
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.4 DISCONNECTION SWITCHES

A.4.1 Supply and erection Supply:


including testing and
o Motorized isolator suitable for 900 V DC supply
commissioning of
along with mounting insulator
motorized
Disconnection Switch o Enclosure panel
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Erection of all above equipment
o Testing& commissioning of all above
equipment’s

A.5 Over voltage protection device (OVPD), Portable SCD, VD & 4 Pole
Motorized SCD.

Volume VII – Pricing Document Page 47 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1

A.5.1 Supply and erection Supply:


including testing and
o Contactor suitable for breaking in 0.1 sec
commissioning of Over
Voltage Protection o Voltage and current sensing equipment
Device (OVPD) o HMI Equipment and protection relay
(including ASS)
o Auxiliary contactor
o Enclosure panel
o Padlocks, Fittings, body earth connection &
other components for completion of Job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.5.2 Portable SCD Supply of Portable Short-Circuiting Device for


Short Circuiting 3rd Rail in complete with rating of
100 kA, 35 msec

A.5.3 Voltage Detector Supply of Voltage detector suitable for 3rd Rail
Voltage detection for each station and Depot.

A.5.4 4 Pole Motorized SCD o Four pole motorized short circuit and earthing
panel along with all necessary accessories as
per specifications.
o All necessary cable along with terminations
(Power & Control) shall we consider (FRLS for
Elevated/At-Grade and FRLSOH for
Underground Stations)
o Fittings and other components for completion
of job as per specifications.
o Floor and insulation mats of appropriate voltage
rating for placement of DC Equipments
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

Volume VII – Pricing Document Page 48 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1

A.6 NEGATIVE RETURN PANEL

A.6.1 Supply and erection Supply:


including testing and
o Manual isolator along with mounting insulator
commissioning of
as per specifications
Negative Return Panel
for Two rectifier set o Connectors for cables
o Enclosure panel
o Padlocks, Fittings & other components for
completion of Job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.7 INVERTER TRANSFORMER

A.7.1 Supply and erection Supply:


including testing and
o Inverter transformer along with enclosure
commissioning of 1000
kVA ;585/33000 V, Dry o Mounting rails
Type Inverter o Temperature sensor, alarm and trip modules
Transformer as per
specification o Fire protection system as per Specifications
o Fittings & other components for completion of
job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

A.8 INVERTER

A.8.1 Supply and erection Supply:


including testing and
o Inverter along with enclosure
commissioning of 1000
kVA inverter & its o Mounting rails
Connections o Temperature sensor, alarm and trip modules
o Fire protection system as per Specifications

Volume VII – Pricing Document Page 49 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1
o Fittings & other components for completion of
job
Erection & Commissioning:
o Erection of all above equipment
o Testing & commissioning of all above
equipment’s

B.1 TRANSFORMER – RECTIFIER CONNECTION

B.1.1 Supply and erection Supply:


including testing and
o TP, 2000A, indoor sandwich type aluminum bus
commissioning of LV
duct as per specification
Bus Duct – Rectifier
Transformer to Rectifier o All hardware, connection pieces, horizontal /
connection vertical bends etc., as required
o Aluminum laminated flexible joint as required
o Flexible termination at both ends with aluminum
lamination per TPN set
o Support arrangement from ceiling walls etc.
o Mounting channels if required
Erection & Commissioning:
o Erection of all above equipment including
terminations at both ends
o Testing & commissioning of all above
equipment

B.2 DC POSITIVE CABLES (3.3 kV Class)

B.2.1 Supply, laying, Supply:


termination, testing and
o Flexible class 5, DC Cable (3.3 kV insulation
commissioning of
class) for mainline and depots as per
1Cx400 sqmm FRLS
specifications from rectifier to HSCB, HSCB to
unarmoured DC Cable
third rail, etc.
for DC feeder circuit in
the elevated / at-grade o Termination kit (Heat shrinkable tape and
stations & Viaduct Heavy duty long barrel copper lugs).
o Cutout/Opening Sealing arrangements as per
Specifications.

Volume VII – Pricing Document Page 50 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1
o Mounting arrangement at HSCB, rectifier
o Other components for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories and all
components as indicated above
o Appropriate sealing of cutout as per
specifications and drawings
o Testing & commissioning of cable &
accessories

B.2.2 Supply, laying, Same as above item except that cables and joint
termination, testing and / termination kits shall be FRLSOH type for
commissioning of underground sections instead of FRLS type.
1Cx400 sqmm
FRLSOH unarmoured
DC Cable for DC feeder
circuit in the
underground stations &
tunnel

B.3 DC NEGATIVE CABLES (1.1 kV Class)

B.3.1 Supply, laying, testing Supply:


and commissioning of
o Flexible class 5, DC Cable (1.1 kV insulation
1Cx400sqmm DC
class) for mainline and depots as per
negative cable and
specifications NR Panel to running rail etc.
connection for DC
return circuit in the o Termination kit (Heat shrinkable tape and
elevated / at-grade Heavy-duty long barrel copper lugs).
section & station. o Cutout/Opening Sealing arrangements as per
specifications.
o Mounting arrangement NR panel
o Other components for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories and all
components as indicated above
o Appropriate sealing of cutout as per
specifications and drawings

Volume VII – Pricing Document Page 51 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1
o Testing & commissioning of cable &
accessories

B.3.2 Supply, laying, testing Same as above item except that cables and joint
and commissioning of / termination kits shall be FRLSOH type for
1Cx400sqmm DC underground sections instead of FRLS type.
negative cable and
connection for DC
return circuit in the
underground sections
and stations.

B.4 FRAME CONNECTIONS

B.4.1 Supply, laying, testing Supply:


and commissioning of
o Unarmored DC Cable (1.1 kV insulation class)
1Cx400 sqmm Cables
for interconnections as per the specifications
for interconnection of
casings / frame etc. of o Termination kit (Heat shrinkable tape and
HSCB panel, NR panel, Heavy-duty long barrel copper lugs).
bypass panel, frame o Cutout/Opening Sealing arrangements as per
leakage relay etc. for specifications.
elevated / at-grade
TSSs o Mounting arrangement
o Cable support arrangements
o Other components for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories and all
components as indicated above
o Testing & commissioning of cable &
accessories

B.4.2 Supply, laying, testing Same as above item except that cables and joint
and commissioning of / termination kits shall be FRLSOH type for
1Cx400sq.mm Cables underground sections instead of FRLS type.
for interconnection of
casings / frame etc. of
HSCB panel, NR panel,
bypass panel, frame
leakage relay etc. for
underground TSSs

Volume VII – Pricing Document Page 52 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation TSS
Item No. BOQ Item Description
BOQ Bill Nos. IN-5.1

B.5 RETURN FEEDER CABLE

B.5.1 Supply, laying, testing Supply:


and commissioning of 1
o Unarmored DC Cable (1.1 kV insulation class)
x 1C x 630 sqmm XLPE
for parallel track return current as per
FRLS Al Cables for
specification.
parallel track feeder
connected to track o Termination kit (Heat shrinkable tape and
every 250 m, including Heavy-duty long barrel copper lugs).
two cross bonds every o Fixing arrangement to running rail
250 m between rails &
Track o Cable support arrangement
o Cutout/Opening Sealing arrangements as per
specifications.
o Other components for completion of Job
Erection & Commissioning:
o Laying of cable, erection of accessories and all
components as indicated above
o Testing & commissioning of cable &
accessories

B.5.2 Supply, laying, testing Same as above item except that cables and joint
and commissioning of 1 / termination kits shall be FRLSOH type for
x 1C x 630 sqmm XLPE underground sections instead of FRLS type.
FRLSOH Al Cables for
parallel track feeder
connected to track
every 250 m, including
two cross bonds every
250 m between rails &
Track

2.7 Third Rails and Stinger


2.7.1 The Bill of Quantity for Purple and Red Line of Third Rail is presented in BOQ Bill
Nos. IN-6.1. For detailed specifications, and the Chapter 16 of TS Vol-IV shall be
referred to.
2.7.2 Following notes are explanation of the items under these Bill Nos.:
General Note:
1. The Design of 3rd Rail Systems, including Stingers System is in the scope of

Volume VII – Pricing Document Page 53 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Power Supply Contractor.


2. The Third Rail shall be installed by Power Supply Contractor in both mainlines
and Depots and required to Interface with Trackwork contractor accordingly.
3. The testing and commissioning of the installed third rails shall be undertaken
by Power Supply Contractor. All special tools, plants and other equipment’s
etc. required to provide provision in track plinth and depot for installation of the
third rail system shall be provided by Traction Contractor to Trackwork
Contractor.

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1

A THIRD RAIL

A.1 Design, supply, Supply:


installation, interfacing,
o Conductor rails
and testing &
commissioning of o All hardware and accessories
conductor rails as per o Zinc-loaded contact grease
Specifications
o Other components for completion of Job
including Numbering/Labeling.
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.2 Design, supply, Supply:


installation, interfacing,
o Splice joint assembly
and testing &
commissioning of splice o All hardware and accessories
joint assemblies as per o Zinc-loaded contact grease
Specifications
o Other components for completion of Job
including Numbering/Labeling
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for

Volume VII – Pricing Document Page 54 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.3 Design, supply, Supply:


installation, interfacing,
o Protective UPVC / GRP cover with all
and testing &
required hardware
commissioning of
UPVC / GRP insulated o Zinc-loaded contact grease
cover for Conductor o Other components for completion of Job
Rails as per including Numbering/Labeling
Specifications
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.4 Design, supply, Supply:


installation, interfacing,
o Expansion joint assembly with all hardware
and testing &
and accessories required to make it a
commissioning of
complete functional unit
Expansion Joint
Assemblies as per o Splice joint assembly with all hardware
Specifications o Special Protective UPVC / GRP cover with
all required hardware
o Zinc-loaded contact grease
o Type test, batch test and routine test
certificates as per the specifications
o Other components for completion of Job
including Numbering/Labeling
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for

Volume VII – Pricing Document Page 55 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.5 Design, supply, Supply:


installation, interfacing,
o Ramp assembly with all hardware and
and testing &
accessories required to make it a complete
commissioning of High
functional unit
Speed Ramp
Assemblies o Splice joint assembly with all hardware
Specifications o Special Protective UPVC / GRP cover with
all required hardware
o Zinc-loaded contact grease
o Other components for completion of Job
including Numbering/Labeling
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.6 Design, supply, Supply:


installation, interfacing,
o Ramp assembly with all hardware and
and testing &
accessories required to make it a complete
commissioning of Low
functional unit
Speed Ramp
Assemblies as per o Splice joint assembly with all hardware
Specifications o Special Protective UPVC cover with all
required hardware
o Zinc-loaded contact grease
o Other components for completion of Job
including Numbering/Labeling
Erection, interface and Testing &
Commissioning:

Volume VII – Pricing Document Page 56 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.7 Design, supply, Supply:


installation, interfacing,
o Design of site specific support assemblies
and testing &
commissioning of Third o Galvanized MS brackets
rail Brackets including o Insulated support assembly with insulator,
Insulated Support all hardware and accessories required to
Assemblies as per make it a complete functional unit
Specifications
o Special Protective UPVC / GRP cover with
all required hardware
o Zinc-loaded contact grease
o Other components for completion of Job
including Numbering/Labeling
Erection, supervision, interface and
Testing & Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.8 Design, supply, Supply:


installation, interfacing,
o Rail Anchors with all hardware and
and testing &
accessories required to make it a complete
commissioning of Mid
functional unit
Point Anchor
Assemblies as per o Special Protective UPVC / GRP cover with
Specifications all required hardware
o Zinc-loaded contact grease
o Other components for completion of Job

Volume VII – Pricing Document Page 57 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
including Numbering/Labeling
Erection, interface and Testing &
Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

A.9 Design, supply, Supply:


installation, interfacing,
o Power Feed assembly with all hardware
and testing &
and accessories required to make it a
commissioning of
complete functional unit
Power Feed
Assemblies as per o Bimetallic copper / aluminium interface as
Specifications required
o Special Protective UPVC / GRP cover with
all required hardware
o Zinc-loaded contact grease
o Other components for completion of Job
including Numbering/Labeling
Erection, supervision, interface and
Testing & Commissioning:
o Design review and installation designs
o Deployment of supervision experts for
installation
o Acceptance tests, system tests and
commissioning including all necessary tools
& plants required for this purpose.

B STINGER SYSTEM

B.1 Design, supply, Supply:


installation, testing and
o Conductor rails
commissioning of
enclosed conductor rail o Fixing brackets
(of 4.5m length each), o Support accessories
complete with all fixing /

Volume VII – Pricing Document Page 58 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
support brackets, all o All hardware
accessories, hardware
o Zinc-loaded contact grease
etc. for stinger system in
Inspection Bay lines o Other components for completion of Job
and as per the including Numbering/Labeling
specifications Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the conductor rails
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.2 Design, supply, Supply:


installation of
o Cover for Conductor rails
commissioning of end
cover for above o Fixing brackets
enclosed conductor rail o Support accessories
including all hardware
as required o All hardware
o Other components for completion of Job
including Numbering/Labeling
Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the covers for conductor
rails
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.3 Design, supply, Supply:


installation, testing and
o Splice assembly
commissioning of splice
assembly for above o Support accessories
enclosed conductor rail o All hardware
complete with all
hardware and o Zinc-loaded contact grease

Volume VII – Pricing Document Page 59 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
accessories as required o Other components for completion of Job
including Numbering/Labeling
Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the splice assembly
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.4 Design, supply, Supply:


installation, testing and
o Suspension clamps
commissioning of
suspension clamp for o Fixing brackets
stinger system o Support accessories
complete with all
hardware and o All hardware
accessories as required o Other components for completion of Job
including Numbering/Labeling
Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the suspension clamp
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.5 Design, supply, Supply:


installation, testing and
o Power feed assembly
commissioning of power
feed assembly for o Support accessories
above enclosed o All hardware
conductor rail complete
with all hardware and o Zinc-loaded contact grease
accessories as required o Other components for completion of Job
including Numbering/Labeling
Erection & Commissioning:

Volume VII – Pricing Document Page 60 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
o Assembling, installing, testing and
commissioning of the power feed assembly
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.6 Design, supply, Supply:


installation, testing and
o Collection trolley
commissioning of
collection trolley for o Support accessories
above enclosed o All hardware
conductor rail complete
with all hardware and o Other components for completion of Job
accessories as required including Numbering/Labeling
Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the collection trolley
o All the manpower, small materials, tools,
plants, testing equipments etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

B.7 Design, supply, Supply:


installation, testing and
o Isolator switch
commissioning of
isolator switch complete o Fixing brackets
with support tray, cable, o Operating arrangement
cover, enclosure,
distribution cubicle and o Support trays,
other all accessories as o Cable, cover
required and as per the
o Enclosure
specifications
o Distribution cubicle
o Support accessories
o All hardware
o Other components for completion of Job

Volume VII – Pricing Document Page 61 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
including Numbering/Labeling
Erection & Commissioning:
o Assembling, installing, testing and
commissioning of the isolator switch
o All the manpower, small materials, tools,
plants, testing equipment’s etc. required for
installation and testing of the conductor rails
are included in this item
o Interface with the designated contractor

C Floating Depot

C.1 Design, supply, Supply:


installation, testing and
o VLD-F Diode Panel
commissioning of
Voltage Limiting device- o Other components like mounting structure
fault (VLD-F) system etc. for completion of Job
complete with all Erection & Commissioning:
hardware and
accessories as required o Assembling, installing, testing and
commissioning of the VLDF
o All the manpower, small materials, tools,
plants, testing equipment etc. required for
installation and testing commissioning are
included in this item
o Interface with the Depot/Track contractor

C.2 Design, supply, Supply:


installation, testing and
o Sacrificial earth pit including associated civil
commissioning of
work and running rail pieces.
Sacrificial earth pit
including associated o All necessary component and accessories
civil work and running to completion of job
rail pieces for for safety
of working personnel
complete with all Erection & Commissioning:
hardware and o Erection, testing and Commissioning
accessories as required of above

C.3 Design, supply, Supply:


installation, testing and

Volume VII – Pricing Document Page 62 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation Third Rail


Item No. BOQ Item Description
BOQ Bill Nos. IN-6.1
commissioning of 2 pole o 2 pole Load Break Switch (2 pole LBS)
load break switch (2
o Connectors for cables
pole LBS) system
complete with all o Enclosure panel
hardware and o Padlocks, Fittings & other components for
accessories as required
o LV control and power cables of required
sizes from RTU at Depot TSS
o Termination lugs, glands, ferrules, ties,
markers etc
o Testing & commissioning of cable &
accessories

Erection & Commissioning:


o Assembling, installing, testing and
commissioning of the 2 pole LBS including
laying of cable, erection of accessories and
all components as indicated above
o All the manpower, small materials, tools,
plants, testing equipment etc. required for
installation and testing commissioning are
included in this item
o Interface with the designated contractor

2.8 Earthing & Bonding


2.8.1 The Bill of Quantity for Purple and Red Line is presented in BOQ Bill Nos. IN-7.1 .
For detailed specifications, the Chapter 17 of TS Vol-IV shall be referred to.
2.8.2 Following notes are explanation of the items under these Bill Nos.:

Item Explanation Earthing & Bonding


BOQ Item Description
No. BOQ Bill Nos. IN-7.1

A EARTHING AND BONDING

A.1 Earthing in ASS/TSS

A.1.1 Supply, laying and Supply:


Connections of Earthing

Volume VII – Pricing Document Page 63 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item Explanation Earthing & Bonding


BOQ Item Description
No. BOQ Bill Nos. IN-7.1
from equipment’s to METs o Earthing of all equipment’s covered
inside the Type 1 SS under underground station with ASS
only
o 50X6 GI Flats as per specifications
o Welding/brazing and connections
o Other components for completion of
Job
Erection & Commissioning:
o Laying & connection of material as per
approved design
o Testing & commissioning

A.1.2 Supply, laying and Supply:


Connections of Earthing
o Earthing of underground station with
from equipment’s to METs
ASS & TSS only
inside the Type 2 SS
o 50X6 GI Flats as per specifications
o Welding/brazing and connections
o Other components for completion of
Job
Erection & Commissioning:
o Laying & connection of material as per
approved design
o Testing & commissioning

A.1.3 Supply, laying and Supply:


Connections of Earthing
o Earthing of at grade/elevated corridor
from equipment’s to METs
station, depot substation with ASS only
inside the Type 3 SS
o 50X6 GI Flats as per specifications
o Welding/brazing and connections
o Other components for completion of
Job
Erection & Commissioning:
o Laying & connection of material as per
approved design

Volume VII – Pricing Document Page 64 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item Explanation Earthing & Bonding


BOQ Item Description
No. BOQ Bill Nos. IN-7.1
o Testing & commissioning

A.1.4 Supply, laying and Supply:


Connections of Earthing
o Earthing of at grade/elevated corridor
from equipment’s to METs
station with ASS and TSS only
inside the Type 4 SS
o 50X6 GI Flats as per specifications
o Welding/brazing and connections
o Other components for completion of
Job
Erection & Commissioning:
o Laying & connection of material as per
approved design
o Testing & commissioning

A.1.5 Supply, laying and Supply:


Connections of Earthing
o Earthing of depot/elevated substation
from equipment’s to METs
with TSS only
inside the Type 5 SS
o 50X6 GI Flats as per specifications
o Welding/brazing and connections
o Other components for completion of
Job
Erection & Commissioning:
o Laying & connection of material as per
approved design
o Testing & commissioning

A.2 Earthing in Stations,


Viaduct and other place as
per requirement

A.2.1 Supply, laying and Supply:


Connections of 185 sqmm
o 185 mm2 Al conductor (SEC)
bare Al Structure Earth
Conductor on viaduct & o Appropriate supporting structure and
tunnel sections with clamps
ASS/TSS substations at o Connectors and other components for
grade/elevated/Underground completion of job

Volume VII – Pricing Document Page 65 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item Explanation Earthing & Bonding


BOQ Item Description
No. BOQ Bill Nos. IN-7.1
on stich concrete using GI Erection & Commissioning:
cleats of suitable size
o Erection of all above items, laying and
connection of various conductors
o Earth cable to MET connection
o Checking & commissioning of
connection

A.2.2 Supply, laying and Supply:


Connections of 120 sqmm
o 120 mm2 insulated Al conductor
unarmoured Al cable with all
hardware including Al lugs o Connectors and other components for
for connections for hand rail, completion of job
Pier head, bonding, plinth Erection & Commissioning:
continuity, track-bed
continuity, walkway bonding, o Erection of all above items, laying and
station structure bonding, connection of various conductors
viaduct lightning system etc o Connection to 185 sqmm SEC
o Checking & commissioning of
connection

2.9 SCADA
2.9.1 The Bill of Quantity for Yellow Line of SCADA is presented in BOQ Bill Nos. IN-8.1.
For detailed specifications, Chapter 18 of TS Vol-IV shall be referred to.
2.9.2 Following notes are explanation of the items under these Bill Nos.:

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1

A Operation and Control Centre (OCC)

A.1 Servers

A.1.1 Dual Redundant SCADA Supply: -


Communication Servers (Main
One Set of Server includes two
and Standby, including MS
SCADA servers (one main and one
Office Professional & Antivirus
standby SCADA server system) in
Software)
redundant configuration needed for
the control & monitoring of electrical
installations included in the scope of
work, from the OCC.

Volume VII – Pricing Document Page 66 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
One Set of this item shall essentially
include but not limited to the following:
o Two SCADA Communication
Servers (one main & one standby)
o Basic Software’s (OS, All Drivers,
MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
Keyboard and Mouse for each set
of servers
o 1 No. KVM switch with cables &
connectors for Monitor, Mouse &
Keyboard interface for each set of
servers.
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Servers and
Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
o Communication interface of
Servers over OFC backbone with
RTUs
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

A.1.2 Dual Redundant SCADA Supply: -


Database cum Application
One Set of Server includes two
Servers (Main and Standby,
SCADA servers (one main and one
including MS Office
standby SCADA server system) in

Volume VII – Pricing Document Page 67 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Professional, Antivirus Software redundant configuration needed for
& External Bulk Storage for Data storage & handling the complete
and Software Back-up System) database & for the control &
monitoring of electrical installations
included in the scope of work, from
the OCC.

One Set of this item shall essentially


include but not limited to the following:
o Two SCADA Database cum
Application Servers (one main
& one standby)
o Basic Software’s (OS, All
Drivers, MS office etc.)
o RDBMS Software
o Antivirus software with 5 years
of license subscription from
the date of commissioning.
o 1 No. 24" LED Monitor with
Keyboard and Mouse for each
set of servers
o 1 No. KVM switch with cables
& connectors for Monitor,
Mouse & Keyboard interface
for each set of servers.
o External bulk Storage Media
facility (Network attached
storage device)
o Any other
components/accessories
required for completion of the
works.
Erection/Installation: -
o Installation of Servers and
Powering-up
o Installation of all Software’s,

Volume VII – Pricing Document Page 68 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning
o Testing & commissioning of
above equipment’s

A.1.3 Engineering Server (including Supply: -


MS Office Professional &
SCADA Engineering server shall be
Antivirus Software)
provided for SCADA HMI engineering,
RTU Configuration, Testing and other
development and maintenance
purpose.
One Set of this item shall essentially
include but not limited to the following:
o One SCADA Engineering Server

o Basic Software’s (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Server and
Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning:
o Testing & commissioning of
above equipment’s

Volume VII – Pricing Document Page 69 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1

A.1.4 Web Server (including MS Supply: -


Office Professional & Antivirus
Web Server shall be provided for
Software)
remote viewing of SCADA system. No
control shall be provided in Web
Server.
One Set of this item shall essentially
include but not limited to the following:
o One SCADA Web Server

o Basic Software’s (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Server and
Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

A1.5 Energy Management system An Energy Management System shall


(including MS Office be provided for inspecting, cleaning,
Professional & Antivirus transforming, and modelling energy
Software) and tele-measurands data with the
goal of discovering useful information
and generation of MIS reports.

Volume VII – Pricing Document Page 70 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
One Set of this item shall essentially
include but not limited to the following:
o One SCADA Server

o Basic Software’s (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.

Erection/Installation: -
o Installation of Server and
Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

A.2 Workstations

A.2.1 Operator Workstation with dual Supply: -


Monitor (including MS Office
This item shall include the supply of
Professional & Antivirus
workstations needed as man machine
Software)
interface for control, monitoring and
supervision of electrical installations
included in the scope of work, from
the OCC. Workstation details are
given below:
1. Operator Workstation with dual
Monitor

Volume VII – Pricing Document Page 71 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
2. Disturbance Recorder
3. workstation for Depot control
center
One Set of this item shall essentially
include but not limited to the following:
o One Workstation Computer

o Basic Software’s (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years
of license subscription from
the date of commissioning
o Dual 24" LED Monitors with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Workstation &
Monitors and Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

A.3 Communication Equipment

A.3.1 Redundant SCADA LAN Supply: -


including managed switches,
This item includes the supply of
FO & LAN cables and all
redundant SCADA LAN in OCC for
accessories for communication
data exchange between various
over Telecom Network
SCADA equipment’s (Servers,
Workstations, Printers, Video Control
Panel etc.) and integration with field
RTUs with SCADA system over

Volume VII – Pricing Document Page 72 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Telecom OFC backbone.

One Set of this item shall essentially


include but not limited to the following:
o Layer-2, 24-Port Managed
Ethernet Switch (Core Switch in
Server Room) – 2 Nos.
o Layer-2, 8-Port Managed
Ethernet Switch (Access Switch in
OCC Theatre Room) - 2 Nos.
o Redundant Fiber optic cable
(Armoured, FRLS-0H) for SCADA
system communication at OCC
and communication link from TER
to SCADA server room and from
SCADA server room to OCC
Theatre room.
o CAT 6 or latest communication
cable (STP, Armoured, in case of
cable laying outside the panel in a
trench or cable tray) for
connecting all concerned SCADA
equipment’s in dual LAN network.
o CAT 6 or latest communication
cable (STP, Unarmoured, in case
of cable laying inside a panel) for
connecting all concerned SCADA
equipment’s in dual LAN network.
o If required communication cables
shall be laid inside flexible
metallic conduit.
o LIU (Light Interfacing Unit) Box

o Patch Cables RJ 45 / FO

o Any other
components/accessories required
for completion of the works.
Erection

Volume VII – Pricing Document Page 73 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o Installation of all networking
devices and Powering-up
o Laying and connection of
communication cables
o Network Connectivity & network
configuration.
o FO cable testing for connectivity
of SCADA communications
equipment’s with OFC backbone
Testing & Commissioning: -
o Testing & commissioning of
above equipment

A.3.2 Firewall Supply: -


This item includes the supply of
Network Firewall/L3 Router for Web
Server and Master clock interface and
shall essentially include, but not
limited to the following:

o Hardware Firewall/L-3 Router

o Any other
components/accessories required
for completion of the works.
Erection: -
o Installation of all networking
devices and Powering-up
o Network Connectivity &
configuration of Firewall
Testing & Commissioning: -
o Testing &commissioning of
above equipment

A.4 Server Rack Supply: -


This item shall include, but not
limited to the following:

Volume VII – Pricing Document Page 74 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o 19” Server Rack

o Any other
components/accessories required
for completion of the works
Erection & Commissioning: -

o Installation of server rack Earthing


of all SCADA equipment’s and
rack

A.5 Equipment Room Furniture Supply: -


The item includes suitable and
aesthetically designed furniture at
SCADA server room. It shall
essentially include but not limited to
the following:
o The Desk and set of drawers.

o Roller chairs

o Any other
components/accessories required
for completion of the works.
Erection & Commissioning: -
o Installation of furniture

Note: The contractor shall interface for


the design and material to be used

A.6 Printers

A.6.1 LaserJet B/W A4/A3 Supply: -


This item shall include, but not
limited to the following:
o A4/A3 LaserJet printer – 1 No.

o Any other
components/accessories required
for completion of the works.

Volume VII – Pricing Document Page 75 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Erection & Commissioning: -
o Installation of printer and
powering up
LaserJet Colour A4/A3
A.6.2 Supply: -
This item shall include, but not
limited to the following:
o A4/A3 LaserJet printer – 1 No.

o Any other
components/accessories required
for completion of the works.
Erection & Commissioning: -
o Installation of printer and
powering up

A.7 Training Simulator System Supply: -


including Training RTU (For
One set of the Training Simulator
OCC only)
System shall essentially include, but
not limited to the following:
o One No. Trainer server cum
workstation
o Dual 24” LED Monitors with
wireless Keyboard and Mouse for
Trainer
o Three Nos. Trainee workstation

o Dual 24” LED Monitors with


wireless Keyboard and Mouse for
each Trainee
o One No. Training RTU with all
applicable CPU & I/O Modules,
Power Supply Cards, Converter
etc. and complete with internal
wiring
o Two Nos. Network Switch

o Basic Software (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of

Volume VII – Pricing Document Page 76 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
license subscription from the date
of commissioning
o SCADA Training Simulator
Software with license for One no.
Trainer, Three nos. Trainee’s and
One no. Training RTU.
o Any other
components/accessories
required for completion of the
works.
Erection & Commissioning: -
o Installation of server, workstation,
monitor, network equipment &
Training RTU and Powering-up
o Installation of all Software,
updates & patches
o Installation of software in Training
Simulator server & workstations
o Training Simulator software
configuration, Engineering and
Development
o Network Connectivity &
configuration/setup
o Earthing of Training RTU with
MET
o Laying of input power supply
cables up to RTU and other
communication cables
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. as per Training Simulator
system requirements.
o Testing & commissioning of
Training Simulator setup.

Volume VII – Pricing Document Page 77 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1

A.8 Visual Control Panel 6x2 matrix Supply: -


of 70" LED based DLP rear
One set of this item shall include the
projection unit
supply of LED based DLP Rear
Projection Unit for Red and Purple
Line for displaying Traction and
Auxiliary Network overview and this
item shall essentially include but not
limited to the following:
o Display cubes – 6 columns wide
and 2 rows high, 70" LED Cubes
o LVDS Grid layout may be
changed/adjusted as per site
conditions & layout of OCC
Theatre room
o Dual redundant Graphic Display
Controller with keyboard and
mouse
o Base stand

o Wall Management Software

o Antivirus software for Display


controllers with 5 years of license
subscription from the date of
commissioning
o Any other
components/accessories
required for completion of the
works.
Erection & Commissioning: -
o Installation of complete large
video wall and wall management
software in display controllers
o Network Connectivity &
configuration/setup
o Earthing of video wall and base
stand
o Integration with SCADA system

Volume VII – Pricing Document Page 78 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
and testing and commissioning

A.9 Auxiliary Power Feeding Supply: -


Distribution including cables,
This item includes supply & wiring the
ACDBs and all other
input power supply to UPS and power
accessories
distribution from UPS to all SCADA
equipment’s and shall essentially
include and but not limited to the
following:

o Supply of power cables

o Distribution board and sub


distribution boards for power
supply to various SCADA
equipment’s and power outlets.
o cable containment and any other
accessories
o Any other
components/accessories required
for completion of the works
Erection & Commissioning: -
o Installation of all distribution
boards
o Laying of input power cables to
UPS and power distribution from
UPS to all SCADA equipment’s in
various rooms and in furniture.
o Earthing of all SCADA
equipment and Distribution
boards

A.10 Stray Current Monitoring Supply: -


System (incl. central evaluation
This includes supply of Stray current
unit and stray current monitoring
monitoring system complete with
software)
hardware and necessary software.
The item shall include and but not

Volume VII – Pricing Document Page 79 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
limited to the following:
o 1 No. Central Evaluation System

o Basic Software’s (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
Keyboard and Mouse
o Stray Current Monitoring Software

o Any other
components/accessories required
for completion of the works
Erection/Installation: -
• Installation of Central Evaluation
System and Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
configuration/setup
o SCMS Software configuration,
Engineering and development
o Shall engage specialist to perform
the rail resistance measurement
as well as the track to structure
conductance measurement as
given in EN 50122-2-2010.
Testing & Commissioning: -
o Testing and commissioning of the
system

A.11 SCADA Software Supply: -


It shall include the supply of
complete set of software with
licenses for the concerned Line.
Main OCC.

Volume VII – Pricing Document Page 80 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of software in all
servers, workstations and video
wall controllers
o SCADA software
configuration, Engineering and
Development
Testing & Commissioning: -
o I/O signals testing and
commissioning with field
equipment’s

A.12 Network Management System Supply: -


It shall include the supply of complete
set of software with licenses for the
concerned Line.
Main OCC.
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of software in all
servers, workstations and video
wall controllers
o NMS software configuration,
Engineering and Development
Testing & Commissioning: -
o I/O signals testing and
commissioning with field
equipment’s

A.13 Energy Management System Supply: -


Software
Energy Management System shall be
provided for energy data analysis and

Volume VII – Pricing Document Page 81 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
reporting.
This item essentially includes but not
limited to the following:
o Complete set of software with
licenses for the concerned Line
Main OCC
o Any other
components/accessories required
for completion of the works

Erection & Commissioning: -


o Installation of software in EMS
server
o Software configuration,
Engineering and Development.
o Creation of database and reports
as per functional requirements
under technical specifications.
o Testing and commissioning

B) Back Up Control Centre (BCC)

B.1 Servers

B.1.1 SCADA Communication Server Supply: -


(Standalone server, including
One Set of Server includes one
MS Office Professional &
standalone SCADA server needed for
Antivirus Software)
the control & monitoring of electrical
installations included in the scope of
work, from the BCC.

One Set of this item shall essentially


include but not limited to the following:
o One SCADA Communication

Volume VII – Pricing Document Page 82 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Server
o Basic Software’s (OS, All Drivers,
MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 No. 24" LED Monitor with
Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Server and
Powering-up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
o Communication interface of
Server over OFC backbone with
RTUs
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

B.1.2 SCADA Database cum Supply: -


Application Server (Standalone
One Set of Server includes one
server, including MS Office
standalone SCADA server needed for
Professional, Antivirus Software
storage & handling the complete
& External Bulk Storage for Data
database & for the control &
and Software Back-up System)
monitoring of electrical installations
included in the scope of work, from
the BCC.

One Set of this item shall essentially


include but not limited to the following:
o One SCADA Database cum

Volume VII – Pricing Document Page 83 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Application Server
o Basic Software’s (OS, All Drivers,
MS office etc.)
o RDBMS Software

o Antivirus software with 5 years of


license subscription from the date
of commissioning.
o 1 No. 24" LED Monitor with
Keyboard and Mouse
o External bulk Storage Media
facility (Network attached storage
device)
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of Server and
Powering-up
o Installationof all Software’s,
updates & patches
o Network Connectivity &
Network configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

B.2 Communication Equipment

B.2.1 Redundant SCADA LAN Supply: -


including managed switches,
This item includes the supply of
FO & LAN cables and all
redundant SCADA LAN in BCC for
accessories for communication
data exchange between various
over Telecom Network
SCADA equipment’s (Servers,
Workstations, Printers etc.) and
integration with field RTUs with
SCADA system over Telecom OFC
backbone.

Volume VII – Pricing Document Page 84 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1

One Set of this item shall essentially


include but not limited to the following:
o Layer-2, 16-Port Managed
Ethernet Switch (Core Switch in
Server Room) – 2 Nos.
o Redundant Fiber optic cable
(Armoured, FRLS-0H) for SCADA
system communication at BCC
and communication link from TER
to SCADA control room.
o CAT 6 or latest communication
cable (STP, Armoured, in case of
cable laying outside the panel in a
trench or cable tray) for
connecting all concerned SCADA
equipment’s in dual LAN network.
o CAT 6 or latest communication
cable (STP, Unarmoured, in case
of cable laying inside a panel) for
connecting all concerned SCADA
equipment’s in dual LAN network.
o If required communication cables
shall be laid inside flexible metallic
conduit.
o LIU (Light Interfacing Unit) Box

o Patch Cables RJ 45 / FO

o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of all networking
devices and Powering-up
o Laying and connection of
communication cables
o Network Connectivity & network
configuration.

Volume VII – Pricing Document Page 85 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o FO cable testing for connectivity
of SCADA communications
equipment with OFC backbone
Testing & Commissioning: -
o Testing & commissioning of
above equipment

B.2.2 Firewall Supply: -


This item includes the supply of
Network Firewall/L3 Router for
external interface and Master clock
interface and shall essentially include,
but not limited to the following:

o Hardware Firewall/L-3 Router

o Any other
components/accessories required
for completion of the works.
Erection /Installation: -
o Installation of all networking
devices and Powering-up
o Network Connectivity &
configuration of Firewall
Testing & Commissioning: -

o Testing & commissioning of above


equipment

B.3 Server Rack Supply: -


This item shall include, but not
limited to the following:
o 19” Server Rack

o Any other
components/accessories required
for completion of the works.

Volume VII – Pricing Document Page 86 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Erection & Commissioning: -
o Installation of server rack

o Earthing of all SCADA


equipment’s and rack

B.4 Equipment Room Furniture Supply: -


The item includes suitable and
aesthetically designed furniture at
RSS Control room. It shall essentially
include but not limited to the following:
o The Desk and set of drawers.

o Roller chairs

o Any other
components/accessories required
for completion of the works.
Erection & Commissioning: -
o Installation of furniture

Note: The contractor shall interface for


the design and material to be used

B.5 Printers
LaserJet Colour A4/A3
B.5.1 Supply: -
This item shall include, but not
limited to the following:
o A4/A3 LaserJet printer – 1 No.

o Any other
components/accessories required
for completion of the works.
Erection & Commissioning: -
o Installation of printer and
powering up

B.6 Auxiliary Power Feeding Supply: -


Distribution including cables,
This item includes supply & wiring the
ACDBs and all other
input power supply to UPS and power
accessories
distribution from UPS to all SCADA

Volume VII – Pricing Document Page 87 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
equipment and shall essentially
include and but not limited to the
following:
o Supply of power cables

o Distribution board and sub


distribution boards for power
supply to various SCADA
equipment and power outlets.
o cable containment and any other
accessories
o Any other
components/accessories required
for completion of the works.
Erection & Commissioning: -
o Installation of all distribution
boards
o Laying of input power cables to
UPS and power distribution from
UPS to all SCADA equipment in
various rooms and in furniture.
o Earthing of all SCADA equipment
and
o Distribution boards

B.7 SCADA Software Supply: -


o It shall include the supply of
complete set of software with
licenses for the concerned Line
BCC.
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of software in all
servers and workstations
o SCADA software
configuration, Engineering and

Volume VII – Pricing Document Page 88 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Development
Testing & Commissioning: -
o I/O signals testing and
commissioning with field
equipment

C) Remote Terminal Unit (RTU)

C.1 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in Elevated ASS (Type 1)
include, but not limited to the
following:
o RTU Panel complete with internal
wiring as per specifications and
drawing.
o Processor/CPU Card, Power
Supply Card, Communication
cards etc. all in redundant Hot-
Standby configuration
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories (Dual
Switches, LIU, FO Patch chords
etc.) for linking RTU to TER.
o Communication cables for
interconnection with Relays (at
designated port in switchgear
panel), Energy meters
o 20% spare I/O signals capacity or
min. 1 spare card shall be
provided for each type of module.
o Any other
components/accessories required
for completion of the works.

Volume VII – Pricing Document Page 89 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Erection/Installation: -
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. for the power installation &
integration with OCC/BCC
Testing & Commissioning: -
o I/O signals testing and
commissioning with power supply
equipment’s and integrated.
testing with OCC/BCC

C.2 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in Elevated ASS cum TSS
include, but not limited to the following:
(Type 2)
o RTU Panel complete with internal
wiring as per specifications and
drawing
o Processor/CPU Card, Power
Supply Card,
o Communication cards etc. all in
redundant Hot-Standby
configuration
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &

Volume VII – Pricing Document Page 90 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories (Switches
LIU, FO Patch chords etc.) for
linking RTU to TER.
o Communication cables for
interconnection with Relays (at
designated port in switchgear
panel), Energy meters.
o 20% spare I/O signals capacity or
min. 1spare card shall be
provided for each type of module.
o Any other
components/accessories required
for completion of the works.
Erection /Installation: -
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. for the power installation &
integration with OCC/BCC
Testing & Commissioning: -
o I/O signals testing and
commissioning with power supply
equipment’s and integrated

Volume VII – Pricing Document Page 91 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
testing with OCC/BCC.

C.3 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in Underground ASS (Type
include, but not limited to the following:
3)
o RTU Panel complete with internal
wiring as per specifications and
drawing
o Processor/CPU Card, Power
Supply Card, Communication
cards etc. all in redundant Hot-
Standby configuration.
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories (Switches
LIU, FO Patch chords etc.) for
linking RTU to TER
o Communication cables for
interconnection with Relays (at
designated port in switchgear
panel), Energy meters
o 20% spare I/O signals capacity or
min. 1 spare card shall be
provided for each type of module
o Any other
components/accessories required
for completion of the works.
Erection /Installation: -
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU

Volume VII – Pricing Document Page 92 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. for the power installation &
integration with OCC/BCC
Testing & Commissioning: -
o I/O signals testing and
commissioning with power supply
equipment’s and integrated
testing with OCC/BCC

C.4 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in Underground ASS cum
include, but not limited to the
TSS (Type 4)
following:
o RTU Panel complete with internal
wiring as per specifications and
drawing.
o Processor/CPU Card, Power
Supply Card, Communication
cards etc. all in redundant Hot-
Standby configuration
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories
(Switches, LIU, FO Patch chords
etc.) for linking RTU to TER.
o Communication cables for

Volume VII – Pricing Document Page 93 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
interconnection with Relays (at
designated port in switchgear
panel), Energy meters
o 20% spare I/O signals capacity or
min. 1 spare card shall be
provided for each type of module.
o Any other
components/accessories required
for completion of the works.
Erection /Installation-
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. for the power installation &
integration with OCC/BCC
Testing & Commissioning: -
o I/O signals testing and
commissioning with power supply
equipment’s and integrated
testing with OCC/BCC

C.5 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in Depot (Type 5)
include, but not limited to the
following:
o RTU Panel complete with internal
wiring as per specifications and

Volume VII – Pricing Document Page 94 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
drawing.
o Processor/CPU Card, Power
Supply Card, Communication
cards etc. all in redundant Hot-
Standby configuration
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories
(Switches, LIU, FO Patch chords
etc.) for linking RTU to TER.
o Communication cables for
interconnection with Relays (at
designated port in switchgear
panel), Energy meters
o 20% spare I/O signals capacity or
min. 1 spare card shall be
provided for each type of module.
o Any other
components/accessories required
for completion of the works.
Erection /Installation-
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any

Volume VII – Pricing Document Page 95 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
other functional requirement
under the technical specification
etc. for the power installation &
integration with OCC/BCC
Testing & Commissioning: -
I/O signals testing and commissioning
with power supply equipment’s and
integrated testing with OCC/BCC

C.6 Supply and erection including Supply: -


testing and commissioning of
The Supply of RTU shall essentially
RTU in RSS (Type 6)
include, but not limited to the
following:
o RTU Panel complete with internal
wiring as per specifications and
drawing.
o Processor/CPU Card, Power
Supply Card, Communication
cards etc. all in redundant Hot-
Standby configuration
o All applicable Input-Output
modules & Transducers etc.
o Power Supply Converter &
subsequent distribution inside
panel
o Redundant OFC communication
cables and accessories
(Switches, LIU, FO Patch chords
etc.) for linking RTU to TER.
o Communication cables for
interconnection with Relays (at
designated port in switchgear
panel), Energy meters
o 20% spare I/O signals capacity or
min. 1 spare card shall be
provided for each type of module.
o Any other
components/accessories required

Volume VII – Pricing Document Page 96 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
for completion of the works.
Erection/Installation: -
o Installation of RTU

o Earthing connection of RTU with


MET
o Laying of redundant OFC
communication cables from RTU
to TER
o Laying of communication cables
for interconnection with relays,
Energy meters
o RTU Programming, Development
of database, HMI, logics, events,
alarms, interlockings and any
other functional requirement
under the technical specification
etc. for the power installation &
Integration with OCC/BCC
Testing & Commissioning: -
o I/O signals testing and
commissioning with power supply
equipment’s and integrated
testing with OCC/BCC

D, E & F SCADA Equipments at RSSs

D.1, E.1 Disturbance Recorder Supply: -


& F.1 Workstation with LED Monitor
This item shall include the supply of
workstations needed for control,
monitoring and protection functions
specified, self- monitoring, signaling
and testing facilities, measuring as
well as memory functions, event
recording and evaluation of
disturbance records.

One Set of this item shall essentially


include but not limited to the following:

Volume VII – Pricing Document Page 97 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o One Workstation Computer

o Basic Software’s (OS, All Drivers,


MS office etc.) with DR
functionality and relay
configuration software
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 no. 24" LED Monitors with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection /Installation: -
o Installation of DR
workstation and Powering-
up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

D.2, E.2 Local Work station with LED Supply: -


& F.2 Monitor (including MS Office
This item shall include the supply of
professional and Antivirus
workstations needed for control,
Software)
monitoring and protection functions
specified, self- monitoring, signaling
and testing facilities, measuring as
well as memory functions, event
recording and evaluation of
disturbance records.

One Set of this item shall essentially


include but not limited to the following:

Volume VII – Pricing Document Page 98 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
o One Workstation Computer

o Basic Software’s (OS, All Drivers,


MS office etc.) with DR
functionality and relay
configuration software
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 no. 24" LED Monitors with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works.
Erection /Installation: -
o Installation of DR
workstation and Powering-
up
o Installation of all Software’s,
updates & patches
o Network Connectivity &
configuration/setup
Testing & Commissioning: -
Testing & commissioning of
above equipment’s

D.3, E.3 Local HMI Software Supply: -


& F.3
It shall include the supply of Local
HMI software with licenses for the
local workstation at RSS.
• Any other
components/accessories
required for completion of the
works.
Erection/Installation: -
o Installation of software in local
workstation etc.
o Software configuration,

Volume VII – Pricing Document Page 99 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
Engineering and Development
Testing & Commissioning: -
o I/O signals testing and
commissioning with field
equipment’s at RSS level

D.4, E.4 LAN Switch Supply: -


& F.4
This item shall include the supply of
redundant Managed Ethernet
switches and accessories for
communication of bay level IEDs over
IEC 61850 protocol.
One Set of this item shall essentially
include but not limited to the following:
o Two nos. of managed LAN
switches with IEC 61850
compliant Ethernet and FO ports
o Sufficient no. of Ports with
minimum 50% of spare ports of
each type
o Any other
components/accessories required
for completion of the works.
Erection/Installation: -
o Installation of switches and
Powering- up
o Network Connectivity and
Network configuration/setup
Testing & Commissioning: -
o Testing & commissioning of
above equipment’s

D.5 E.5 O&M Workstation with LED Supply: -


& F.5 Monitor (including MS Office
This item shall include the supply of
Professional & Antivirus
workstation needed for MPMRC O&M
Software)
and shall be connected on a separate
office LAN.

Volume VII – Pricing Document Page 100 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1

One Set of this item shall essentially


include but not limited to the following:
o One Workstation Computer

o Basic Softwares (OS, All Drivers,


MS office etc.)
o Antivirus software with 5 years of
license subscription from the date
of commissioning
o 1 no. 24" LED Monitor with
wireless Keyboard and Mouse
o Any other
components/accessories required
for completion of the works
Erection & Commissioning: -
o Installation of O&M
workstation and Powering-
up
o Installation of all windows
software, updates & patches

D.6, E.6 Furniture Supply: -


& F.6
The item includes suitable and
aesthetically designed furniture for
workstations and printer at RSS
control room. It shall essentially
include but not limited to the following:
o The Desk and set of drawers.

o Roller chairs

o Any other
components/accessories required
for completion of the works.

Erection & Commissioning: -


o Installation of furniture

Note: The contractor shall interface

Volume VII – Pricing Document Page 101 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
with Engineer in-charge for the design
and material to be used.

D.7, E.7 Auxiliary Power Feeding Supply: -


& F.7 Distribution including cables,
This item includes supply & wiring the
ACDBs and all other
input power supply to UPS and power
accessories
distribution from UPS to all SCADA
equipment and shall essentially
include and but not limited to the
following:
o Supply of power cables

o Distribution board and sub


distribution boards for power
supply to various SCADA
equipment and power outlets.
o cable containment and any other
accessories
o Any other
components/accessories required
for completion of the works
Erection & Commissioning: -
o Installation of all distribution
boards
o Laying of input power cables to
UPS and power distribution from
UPS to all SCADA equipment in
various rooms and in furniture.
o Earthing of all SCADA equipment
and Distribution boards

D.8, E.8 LaserJet B/W A4/A3 Printer Supply: -


& F.8
This item shall include, but not
limited to the
following:
o A4/A3 LaserJet printer – 1 No.

o Any other
components/accessories required

Volume VII – Pricing Document Page 102 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
for completion of the works
Erection & Commissioning: -
Installation of printer and powering up
following:
o A4/A3 LaserJet printer – 1 No.

o Any other
components/accessories required
for completion of the works
Erection & Commissioning: -
o Installation of printer and
powering up

D.9, E.9 Firewall/L3 Router Supply: -


& F.9
This item includes the supply of
Network Firewall/L3 Router for Web
Server and Master clock interface and
shall essentially include, but not
limited to the following:

o Hardware Firewall/L-3 Router

o Any other
components/accessories required
for completion of the works.
Erection: -
o Installationof all networking
devices and Powering-up
o Network Connectivity &
configuration of Firewall
Testing & Commissioning: -
Testing &commissioning of
above equipment

G Design, supply, installation, This item includes the price for Design,
testing and commissioning of supply, installation, testing and
communication equipment’s commissioning of communication
(Ethernet switches, Patch cable, equipment’s (Ethernet switches, Patch
Lan cable, routers, firewall for cable, Lan cable, routers, firewall for

Volume VII – Pricing Document Page 103 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Explanation SCADA
Item No. BOQ Item Description
BOQ Bill No. IN-8.1
secure wireless communication secure wireless communication if
if required) / servers/ gateway/ required) / servers/ gateway/
workstations/ required for workstations/ required for control and
control and monitoring. monitoring from OCC.

2.10 General
2.10.1 The Bill of Quantity for General Requirement is presented in BOQ Bill Nos. IN-9.1.
2.10.2 Following notes are explanation of the items under these Bill Nos.:

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1

A TRAINING OF EMPLOYER’S STAFF

A.1 Off Shore Training Optional


(Optional)

A.2 Training In India o This item shall cover the Training of


Employer’s Staff as specified in Chapter
10 of TS Vol-IV
o It shall essentially include, but not limited
to
➢ Training plan
➢ Training tools and staff wages
➢ Training documentation
o The price shall also include the cost of
the training documents implementing as
well as advices after the contract
o The price shall not include the travelling
and accommodation cost of trainees

B MANUALS AND DRAWINGS

B.1 Review of Designs and o This items shall cover the cost of review
preparation of shop of designs of Employer
drawings
o The price shall include the cost of other
drawings to be prepared by the
contractor as specified in Chapter 6 of
TS Vol-IV

Volume VII – Pricing Document Page 104 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1
o The contractor shall produce drawings
for approval of Engineer, and those
required for construction at site
o These will also include calculation
sheets & justifications for any design
changes and improvement to the
satisfaction of Engineer

B.2 Operation and o This items shall cover the Maintenance


maintenance manual & Operation Manuals as specified in
Chapter 8 of TS Vol-IV
o One set of manual shall include all
Operations and Maintenance manuals
pertaining to all equipment’s/systems
which have been used / installed in the
various Corridors under the jurisdiction
of one depot. Accordingly prices for One
set for Subhash Nagar depot shall be
included.
o One set of manuals is meant to
essentially include but not limited to
➢ Operation manuals
➢ Maintenance manuals, drawings
and procedures
o The price shall also include the
Maintenance & Operations documents
implementing as well as documents
originals, copies and electronic file
costs.
o The documents shall be supplied in
prescribed number of copies

B.3 As-Built Drawings o This items shall cover the cost of


supplying As-Built drawings, as
specified in and Chapter 6 of TS Vol-IV,
for each of the corridors included in this
bill
o It shall essentially include, but not limited

Volume VII – Pricing Document Page 105 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1
to
➢ As built drawings depicting the
completed works that have been
certified as complete
➢ Shop drawings containing
information related to the
permanent works
➢ Working drawings containing the
information related to the
temporary works depicting the
construction of permanent works

C.1, C.2, Maintenance o This item shall cover the Maintenance


C.3 Supervision (During supervision for defect notification period
DNP) as specified in Chapter 8 of Technical
Specification Vol-IV.
o The role of the relevant and experienced
engineers will be to ensure that the
maintenance during this period is carried
out by the employer’s staff properly and
that the warranty/guarantee obligations
of the contractor remains undiluted.
o For this purpose, the contractor shall
provide a Supervision Organisation, as
mutually agreed between the Employer
and Contractor and as specified in
Technical Specification- Vol-IV.

D.1 INTEGRATED TESTING & COMMISSIONING

D.1.1 Stage-1: Priority o This item shall cover the Integrated


Corridor (Gandhi Testing & Commissioning as specified in
Nagar to Mumtaj Bag- Chapter 7 of TS Vol-IV.
Elevated Section
o The integrated testing and
including Depot
facility for Priority
commissioning shall be done in stages
section) as per the commissioning schedules of
different section as prescribed in Table
1.3 of Chapter 1 of TS Vol-IV.
o The Integrated Testing &
Commissioning shall essentially include,

Volume VII – Pricing Document Page 106 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1
but not limited to:
➢ Integrated testing &
commissioning plan
➢ Tools, instruments, tackles, and
documents required;
➢ Providing attendance to the
Engineer, including during
inspection by statutory Authorities,
Ministry of Railways and
Commissioner of Railway safety.
➢ Carrying out the appropriate
integrated testing & commissioning
functions.

D.1.2 Stage-2: Balance o Same as above for Stage-1


Elevated Corridor of
Yellow line (Elevated
Section between
Mumtaj Bag to Indore
Railway Station), and
Depot Balance Works

D.1.3 Stage-3: o Same as above for Stage-1


Underground
Corridor of Yellow
line (Underground
Section between
Gandhi Nagar to
Indore Railway
Station)

E.1 TOOLS AND PLANTS

E.1.1 Stage-1 o The price, under this item, shall include


the cost of supplying special tools, plant
and equipment for maintenance and/or
routine repairs as listed in the Chapter 9
of TS Vol-IV of Work’s Requirements for
Stage-1.
o If however the Tenderer feels that some

Volume VII – Pricing Document Page 107 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1
more items or more quantities are
required for the proper operation and
maintenance of the installations supplied
and erected by him, for a period of at
least 5 years commencing from the
expiry of the defect liability period, the
Tenderer shall in that case include such
items and quantities in his bid and quote
them in this very item.
o Portable SCD & Voltage Detector for 3rd
Rail will include Spares for complete
Phase.

E.1.2 Stage-2 Same as above for Stage-1

E.1.3 Stage-3 Same as above for Stage-1

F.1 SPARES

F.1.1 Stage-1 o The price under this item shall include


the cost of supplying spare parts, as
listed in the Chapter 9 of TS Vol-IV of
Work’s Requirements for Stage-1.
o If however the Tenderer feels that some
more items or more quantities are
required for the proper operation and
maintenance of the installations supplied
and erected by him, for a period of at
least 5 years commencing from the
expiry of the defect liability period, the
Tenderer shall in that case include such
items and quantities in his bid and quote
them in this very item. All conductor
supplied as spare shall be in robust steel
drums.

F.1.2 Stage-2 Same as above for Stage-1

F.1.3 Stage-3 Same as above for Stage-1

G.1 Employer’s facility o The price under this item shall include

Volume VII – Pricing Document Page 108 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Item No. BOQ Item Explanation GENERAL


Description
BOQ Bill No. IN-9.1
the cost of all items specified for
Employer’s facilities to be provided by
the contractor as per Chapter 5 of TS
Vol. - IV.

H.1 Viaduct Lighting o This item shall cover the viaduct lighting
as specified in Chapter 11 of TS Vol-IV
of Employer’s requirement
o The price under this item shall include
the cost of supply and erection of light
fittings including all accessories
o The price shall also include the cost of
supplying and erection of Cables and
cable connection/ termination kit from
the appropriate station panel, suitable
for carrying the current required by the
Lighting arrangement.

2.11 Civil and Building Works including Electrifications Works for RSS & TSS
2.11.1 The Bill of Quantity for RSS Civil & Electrification works is presented in BOQ Bill
No.IN-10. Chapter 12 of RSS to be referred to. Following notes are explanation of
the items under the Bill No. IN-10.
2.11.2 For civil works, the scale layout drawings of respective RSS may be referred to, as
provided in Tender Drawings Vol-VI.

Bill No. Item detail Description of work

IN-10.1 Architectural Works for Design, Supply & construction work in all
RSS respect related to the following as per
&
specification and drawings –
10.1(a)
o Brick Works
o Stone Works
o Metal Work
o Steel Works
o Flooring
o Finishing
o Roofing

Volume VII – Pricing Document Page 109 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Bill No. Item detail Description of work

10.2 & Structural Works RSS Design, Supply& construction work in all
respect related to the following as per
10.2(b)
specification and drawings –

Earth Work - Excavation & Backfilling


Concrete Work (Plain & Reinforced)
Reinforcement Work
Water Proofing Work
Miscellaneous Works
Pile Works
Road Work

10.3 Switchyard Civil Works Design, Supply& construction work in all


respect related to the following as per
specification and drawings –

PART - I (SWITCH YARD WORKS)


PART - II (CABLE TRENCHES)
PART - III (ROADS / DRAINS)

10.4 Transformer And Baffle Design, Supply& construction work in all


Wall Civil Works respect related to the following as per
specification and drawings –

SECTION “A”: EXCAVATION, SAND FILLING


ETC.
SECTION “B”: P.C.C., R.C.C.,
GROUTINGPART - SECTION “C”: BRICK
WORK AND FINISHING
SECTION “D”: STRUCTURAL STEEL WORKS

10.5 PHE Works Design, Supply& construction work in all


respect related to the following as per
specification and drawings –
Plumbing and PHE works

Volume VII – Pricing Document Page 110 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Bill No. Item detail Description of work


WATER SUPPLY WORKS
DRAINAGE WORKS
EXTERNAL SEWERAGE, EFFLUENT &
STORM WATER DRAINAGE

10.6 HVAC & Ventilation Design, Supply, Installation, Testing,


system Commissioning of precharged Ready to Use
self-contained Air-cooled split unit comprising of
Hiwall type indoor unit / Rated Outdoor
condensing unit with Inverter Based
Compressor / Air cooled condenser with cooling
fan and safety accessories as specified in C&R
room, Battery room

Design, Supply, Installation, Testing,


commissioning of ceiling fan, wall mounted fans
and ventilation exhaust fans as per specification

10.7 Electrical Works for Wiring System


RSS
o Supply & laying of concealed/ recessed/
surface mounted conduit
o Supply and fixing of Raceway junction box
o Providing and fixing of Modular Switches/
sockets/ Fan regulators with Modular Grid &
Cover plates as require for lighting and fan
controls
o Supply and wiring for lighting/receptacle in
the existing conduit for Lighting Circuits /
Single phase sockets from DB to the switch
control box (SB) with P+N+PE-copper FRLS
ZH 1.1 KV grade cable to connect all lights,
switches, sockets etc. All wires shall be
terminated with pin type lugs and provided
with ferrules for identification. Normally circuit
mains start from the DB, MCB and run up to
the switch box/ MCB Controlled lights upto
first point as required and as under.
o Wire Size: Phase & Neutral: 2.5 mm2 Cu
FRLSZH flexible wire (1.1 KV) Earth: 2.5
mm2 Cu FRLSZH flexible wire (650 V)

Volume VII – Pricing Document Page 111 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Bill No. Item detail Description of work


Lighting
o Supply installation testing commissioning of
LED Light fixture, Lux levels as per IS
specification
o Design, Supply, Erection, Testing &
Commissioning related to: -
o Yard Lighting

10.8 Architectural Works for Design, Supply& construction work in all


TSS respect related to the following as per
specification and drawings –
o Brick Works
o Stone Works
o Metal Work
o Steel Works
o Flooring
o Finishing
o Roofing

10.9 Structural Works Depot Design, Supply& construction work in all


TSS respect related to the following as per
specification and drawings –

Earth Work - Excavation & Backfilling


Concrete Work (Plain, Reinforced & Shuttering)
Reinforcement Work
Miscellaneous Works including Pile works, if
any

2.12 Items not covered vide above Subhead


Payment of each item under this subhead will be paid on mutually agreed rate
analysis, which includes cost of material, machinery, manpower and contractors
profit of 10 %.

Volume VII – Pricing Document Page 112 of 113


Indore Metro Rail Project
Package IN-09
Volume VII – Financial Package Including BOQ

Bill of Quantities for


Tender

Indore Metro Rail Project (Yellow Line)


(Provided in Separate Excel Workbook)

Volume VII – Pricing Document Page 113 of 113

You might also like