Philippine Grid Code
Philippine Grid Code
Grid protection
- The set of measures, devices, and systems implemented to ensure the reliability, stability, and
safety of an electrical power grid. The primary purpose of grid protection is to detect and
respond to abnormal operating conditions or faults within the power system promptly. This helps
prevent widespread outages, equipment damage, and ensures the continued delivery of
electricity to consumers.
Operational responsibility
- Grid owner
- Generators
- System operators
- Grid users
Purpose
(a) To specify the responsibilities of the Market Operator, the System Operator, and other Users
in Scheduling and Dispatch;
(b) To define the operational criteria for the preparation of the Generation Schedule and issuance
of Dispatch Instructions;
(c) To specify the process and requirements for the preparation of the Generation Schedule; and
Market Operator
Preparation and issuance of the Generation Schedule
System Operator
Ensuring that a number of strategically located Generating Units are available for Ancillary
Services, including the provision of Frequency Regulating Reserve and Contingency Reserve.
Issuing Dispatch Instructions for the Scheduled Generating Units and the Generating Units
providing Ancillary Services.
Grid Owner
Providing the System Operator and the Market Operator with data on the availability and operating
status of Grid facilities and Equipment to be used in determining the constraints of the Grid for
Scheduling and Dispatch.
Generators
Ensuring that all Dispatch Instructions from the System Operator are implemented.
Ensuring that its Generating Units can provide the necessary support when instructed by the
System Operator to do so.
The System Operator shall take into account the following factors in dispatching Generating Units
and in satisfying needs for imbalance Energy in real time:
Contain the scheduled time and the Power output of the Generating Unit.
Ramp-up and Ramp-down rates shall be in accordance with the Generation Schedule unless
otherwise stated
Purpose
(a) To establish the requirements for metering the Active and Reactive Energy and Demand input
to and output from the Grid; and
(b) To ensure accurate and prompt procedures for providing and processing metering data for
billing and settlements of the Wholesale Electricity Spot Market.
METERING REQUIREMENTS
Metering Equipment
The metering equipment at the Connection Point shall consist of:
(a) Instrument transformers;
(e) All interconnecting cables, wires, and associated devices, i.e., test blocks, pulse repeaters,
loading resistors, etc.
Metering Responsibility
Meter Operator - supply, install, connect, test, adjust, place in service, operate, check, and maintain
the primary revenue metering System. Consistent with the Market Rules, all primary revenue
meters shall be owned and maintained by the Meter Operator.
Current Transformers
Complies with the IEC Standard or its equivalent national standard for metering, and is of 0.3
accuracy class.
It is preferred that two (2) current transformer cores with corresponding number of secondary coils
per phase be provided between the connection box and the terminal of the metering element
on the meter.
The current transformer’s rated secondary current shall be either 1 or 5 amperes.
Meters
Comply with the appropriate IEC Standards or their equivalent national standards, for static watt-
hour meter and other types of meters, and be of the accuracy class of 0.3 or equivalent.
The meters shall measure and locally display at least the kW, kWh, kVAR, kVARh, and cumulative
Demand, with the features of time-of-use, maintenance records, and pulse output.
The pulse output shall be from a three-wire terminal with pulse duration in the range from 40 to 80
milliseconds
Pulse output shall be galvanically isolated from the voltage/current transformers being measured
and from the auxiliary supply input terminals. The insulation test voltage shall be 1000 VAC, 60
Hz and applied for one minute.
By 1000 hours every Monday or the first Business Day of the week, all Meter Operators shall send
electronically or by fax to the System Operator the hourly data on actual input (supply) and
output (demand) of each metering point for the previous week.
By 1200 hours of the same day, the System Operator shall transfer electronically or by fax to the
Market Operator the hourly data on actual input and output at all metering points for the previous
week. At the same time, the System Operator shall provide the Market Operator actual hourly
dispatch logs for the previous week.
The dispatch log data shall be flagged when a market participant (Generator or Distributor) was
instructed to increase (decrease) output or to reduce (increase) demand. This information shall
be used to calculate the imbalance Energy and Ancillary Service charges.
The Market Operator shall, based on the provided meter data and dispatch logs, prepare
provisional invoices according to the billing and settlement procedures established in the Market
Rules.
Questions:
1. Who has the authority to promulgate the Philippine Grid Code?
A. GMC
B. ERC
C. DOE
D. NEA
2. Which of the following does NOT apply to the PGC?
A. Grid Owner
B. Market Operator
C. Generator
D. Residential Owner
3. How many terms should the members of GMC have?
A. 2 years
B. 3 years
C. 4 years
D. None of the above
4. Among the following, which is NOT considered in the Grid Management Report?
A. Quarterly Reports
B. Significant Incidents
C. Fines and Penalties
D. Special Report
5. During which stage of the application process do users submit information about alternative
connection points?
A. Preliminary Project Planning Data
B. Committed Project Planning Data
C. Connected Project Planning Data
D. Application for Connection or Modification
6. What is the timeframe within which the Grid Owner processes applications for connection or
modification?
A. 15 days
B. 30 days
C. 45 days
D. 60 days
7. Grid Planning Studies include Load Flow Studies, Economic Studies, and Consumer Behavior
Studies. Which of the following accurately represents the truth of the statement?
A. The statement is false.
B. The statement is true, and these studies are part of Grid Planning.
C. The statement is true, but Load Flow Studies are not included.
D. The statement is true; however, only Load Flow Studies are included.
8. Which entity is NOT mentioned as part of the applicable users in Grid Planning?
A. Distributors
B. Manufacturers
C. Suppliers
D. Generators
9. The significant incident notice shall be issued by the System Operator, the Grid Owner or any
User, the notice shall be issued within _______.
A. 60 mins
B. 15 mins
C. 3 mins
D. 3 days
10. What is the purpose of Grid Operation?
A. To ensure the reliable and efficient delivery of electricity from power generation sources to end-
users
B. C is True
C. To support the health and well-being of our planet and everyone who lives here
D. None of the above
11. Who is responsible for the validation and substitution of metering data?
A. Market Operator
B. Distributor
C. Operator
D. All of the Above
12. In what sector states “TRANSCO shall have the authority and responsibility for the planning,
construction and centralized operation, and maintenance of the high voltage transmission
facilities, including Grid interconnection and Ancillary Services”?
A. Distribution Sector
B. Generation Sector
C. Transmission Sector
D. Supply Sector
13. TRANSCO stands for:
A. Nationality Transmissionary Sector
B. Nationwide Transportation Cooperatives
C. Nation’s Transmission Inc.
D. National Transmission Corporation
14. Grid Users are listed below EXCEPT:
A. Greed Owner
B. System Operator
C. Generators
D. Distributors
15. Defined as the ratio of the RMS value of the harmonic content to the RMS value of the
fundamental quantity, expressed in percent.
A. Total Demand Distortion (TDD)
B. Total Harmonic Distortion (THD)
C. Harmonic Voltage Distortion
D. Harmonic Current Distortion
16. Who ensures that all Dispatch Instructions from the System Operator are implemented?
A. Grid Owner
B. System Operator
C. Generators
D. Market Operator
17. Which entity is responsible for maintaining the fundamental frequency within specified limits
in the grid during normal conditions?
A. Generators
B. Distributors
C. System Operator
D. Grid Owners
18.What does Total Demand Distortion (TDD) measure in terms of harmonics within the grid?
A. Ratio of harmonic content to the RMS value of the fundamental quantity
B. Ratio of the RMS value of the harmonic content to the RMS value of the fundamental
quantity
C. Frequency deviations from the nominal value
D. Sustained power interruptions duration
19.Which of the following Financial Ratios is NOT used to evaluate the Financial Capability of both
Generators and the Grid Owner/System Operator?
A. Debt Ratio
B. Quick Ratio
C. Sales-to-Assets Ratio
D. Interest Cover
20.When are Generators and the Grid Owner/System Operator required to submit true copies of
audited balance sheets and financial statements to the ERC?
A. On or before May 1 of the current year
B. On or before May 15 of the current year
C. On or before June 1 of the preceding year
D. On or before June 15 of the preceding year