Exhaust Gas Temperature Overlimit or Stall
The FADEC reduces the fuel flow and attempts a third start. The fuel
schedule reduction in the third start is 7 percent (a total of 14 percent).
If the abnormality occurs a third time, the FADEC shuts off the fuel
and ventilates the engine (crank time 7 seconds).
FOURTH ATTEMPT
After 7 seconds, the FADEC reduces the fuel flow again and attempts
a fourth start. The fuel schedule reduction in the fourth start is 7
percent (a total of 21 percent).
If the abnormality occurs a fourth time, the FADEC aborts the start.