Operating manual

for the user

turbotec lambda control 20-70 kW

09/2004
2
Table of contents
Wood fuel
Commissioning the control
Dear sir, dear madam, 4 kWh x 0.65 = 2.6 kWh
Wood fuel
The turbotec lambda control is the The turbotec lambda control boiler
result of thermostrom’s many years is suitable for wood fuel (natural
of technical experience. It is a wood, i.e. not painted, coated or The relationship between water
highly-developed product that is impregnated) up to a maximum content, storage time and storage
neither to be compared to, nor length of 50 cm, or 100 cm in the location of split logs can be seen
judged by the conventional case of type 60 L. When selecting from the table below
standards of wood burning in ovens the fuel, one must keep in mind that
and boilers of earlier generations. the calorific value of the wood is Storage Storage
Therefore, please read this primarily dependent upon its water time uncovered covered
operating manual thoroughly and content. months water content in %
completely and follow the operating 3 44 36
instructions. For the purpose of simplified cost 9 26 23
If the operation is not clear to you, calculations, it can be assumed that 18 17 15
or if malfunctions occur, please 1 kg of wood with 20 % water 24 16 14
contact your heating installer. content produces approximately the 30 15 13
Naturally, we are also at your same calorific value of about 4 kWh
service for information at any time. (approx. 3500 kcal) for every kind Note:
We hope that the operation of your of wood. - Split logs should be stored for at
heating system meets your The calorific value decreases as least 18 months
expectations and we hope we can the moisture content increases. In - Split logs must be split (max. edge
count you too as one of our many addition, the burning of wood with a length 15 cm)
satisfied thermostrom customers. high water content causes a - Square timbers and scrap planks
decrease in effectiveness. are only suitable to a certain extent
Best regards Please pay attention to the details as fuel (split!)
thermostrom given below:
Energietechnik Gesellschaft mbH
A-4400 Steyr - Dietachdorf,
Commissioning the control
Ennser Strasse 91 After turning on the main heating
Tel. 0043-7252/38271 Correction table for performance switch on site, the power supply to
Fax 0043-7252/3827325 and burning time for good quality the control is activated and a self-
Email: thermostrom@strebel.at woods (beech, oak, fruit trees) and test of the control is carried out
poor quality woods (includes all automatically.
Table of contents strongly resinous woods) After completion of the self-test the
Wood fuel…………………………. 2 control is ready for operation.
Commissioning the control ..……. 2 w% c for wood Alternately, the operating status
Display and operating elements... 3 quality and the boiler temperature appear
Control setting by the user………..4 good poor on the display. In the event a
Heating……………………………...4 5 1.10 1.10 malfunction is displayed after
Adding fuel………………………....5 10 1.05 1.05 turning on the main heating switch,
Additional control functions…….…6 20 1.00 0.90 this must be fixed. (For precise
Chimney sweep test and safety 25 0.95 0.85 information about this, please refer
test………………………….………7 30 0.85 0.80 to the ‘Troubleshooting’ section).
Aggregate 40 0.75 0.70 The main heating switch should
test………………………………….7 50 0.65 0.60 in principle remain switched on,
Cleaning……………………………7 60 0.55 0.50 since otherwise important
Cleaning the control…….…………8 monitoring and protective
Maintenance……………………….8 w = water content of the wood in % functions cannot be performed.
Important information……………..8 c = correction factor Following the combustion
Troubleshooting……….…………..9 Calorific value x correction factor c sequence, the control switches
Brief operating instructions = corrected calorific value automatically to stand-by (energy
lambda control OFF……………...10 efficiency function)
Example calculation for wood
Brief operating instructions
where w = 50 %
lambda control ON …………...….11
3
Display and control elements

1 ‘Heating ON’ indicator 6 ‘Heating OFF / Minus’ button


2 ‘Add fuel’ indicator 7 ‘Arrow’ button
3 ‘Malfunction’ indicator 8 ‘Add fuel’ button
4 Text display 9 Restart button for the safety
5 ‘Heating ON / Plus’ button temperature limiter (STL)

‘Heating ON’ indicator ‘Malfunction’ indicator Text display


Lights up when the combustion Lights up when malfunctions Switched on in the operating
sequence is started by pressing occur which prevent the mode ‘Heating ON’ or by
the ‘Heating ON’ button or continuation of the heating pressing a button in the
automatically due to the sufficient function, respectively do not operating mode ‘Heating OFF’.
exhaust fume temperature. allow the heating function to be Switched off in the operating
Goes out when the combustion switched on. mode ‘Heating OFF’ and at the
sequence is stopped by pressing Blinks if malfunctions occur end of a period of 15 minutes.
the ‘Heating OFF’ button or which allow the continuation of
automatically due to spent fuel. the heating function, respectively ‘Heating ON / Plus’ button
the heating function to be Function level 1:
‘Add fuel’ indicator switched on (automatic steerage Pressing this button activates
Lights up when the heating towards alternative program until the operating mode ‘Heating
function has been switched off and the malfunction is fixed ). ON’
the heating requirement of the Goes out when the malfunctions Function level 2:
installation requires, respectively have been fixed and Functions can be selected or
enables fuel to be added again. acknowledged. settings changed by pressing
Blinks during the 'Add fuel' this button.
function.
Goes out when the heating
function is switched on or the ‘Add
fuel’ function has been suspended.

4
Control settings by the user
Heating up

‘Heating OFF / Minus button Controller settings by the Heating up


Function level 1: user
This button can be used to Heating up when the
switch the operating mode to Setting the boiler installation is cold
'Heating OFF' or to end the temperature During the initial
‘Add fuel’ function prematurely. Following the first commissioning, or after a long
Function level 2: commissioning of the control standstill, the following should
Functions can be selected or and the ensuing system be observed:
settings changed by pressing settings by a professional, the A ‘cold’ chimney has no, or too
this button. following message appears on little outlet pressure, so that in
the text display: this case the exhaust fumes are
‘Arrow’ button Heating poorly expelled. Heating up will
This button is used to enter the OFF be facilitated if you heat up the
Selection menu and to shift to The Selection menu is entered chimney with paper through the
Function level 2. by pressing the 'Arrow' button cleaning hatch.
Pressing the button once again and the following message
confirms the selected function appears on the display: Boiler operating behaviour
or changed settings. SELECTION+_ Particular attention must be
INFORMATION paid to the operating behaviour
‘Add fuel’ button The menu item ‘SETTINGS’ is of the boiler in interaction with
Pressing this button causes the selected by pressing the ‘Plus’ the hydraulic system, when
induced draft fan to operate at button. The following appears starting from a cold condition.
high speed, and after 15 on the text display: In doing so:
seconds the electromagnetic SELECTION+_ - the boiler must first of all heat
door opener is released for 10 SETTINGS up its own water content
seconds. The ‘Add fuel’ The selected menu item is including its material weight,
function is ended automatically confirmed by pressing the - the water content of the
after 10 minutes. ‘Arrow’ button. The following heating system (pipes,
appears on the text display: radiators, thermal storage mass
Restart button for the safety Boiler set point + _ of the floor) must be heated up.
temperature limiter (STL) TK S [°C] ## Heat can only be released into
If the STL has tripped due to The value can be changed by the room after this heating
the boiler temperature being pressing the 'Plus' or 'Minus' process has been completed.
too high, and if the boiler button. The time to complete this
temperature has gone down to process differs, depending on
Setting range: 70 – 85 °C
approx. 80 °C, then the STL By changing the boiler set
the water content in the heating
must be reset and the error system. This means that you
point, the storage charging
acknowledged by pressing the may have to start heating up
behaviour also changes. The
restart button. earlier due to this delay. During
value should only be changed
this heating up period the boiler
after consulting your heating
produces its full power = rated
installer.
power. The lambda control
The changed value is saved by
regulates the combustion
pressing the ‘Arrow’ button.
sequence in such a way that
Pressing the ‘Arrow’ button
the boiler power produced,
once again will take you via the
corresponds with the actual
next menu item back to the text
power consumption of the
display:
heating system.
Heating
OFF
Standard values for the
heating-up time in minutes for
an increase in the boiler
temperature from 20 °C to 70
°C – see table:
5

Add fuel
Boiler type Rated Heating- wood, place paper and As a matter of principle, more
power up time* cardboard on top and ignite fuel should be added only if the
kW in from above. fuel has been used up totally,
minutes when heating is required and
turbotec 20 20 40 - switch on the induced draft the ‘Add fuel’ indicator lights
turbotec 25 25 35 fan again by pressing the ‘Add up.
turbotec 30 30 30 fuel’ button; the ‘Add fuel’ - Pull and latch the operating
turbotec 40 40 25 indicator blinks for 10 minutes handle of the gas vent flap
turbotec 40 S 40 40 - close the interior door; the - Press the ‘Add fuel’ button.
turbotec 50 50 35 filling door remains open The text display shows:
turbotec 60 60 30 - wait until the control switches DO NOT OPEN!
turbotec 60 L 60 35 automatically to the operating Please wait!
turbotec 70 70 25 mode ‘Heating ON’; the The induced draft fan operates
following appears in the text at high speed and the ‘Add fuel’
display: indicator blinks for 10 minutes
(*)The heating-up time in
Heating - The door opener is released
minutes should be considered
ON after 15 seconds and the text
to be standard value only
(based on the rated power of and the ‘Heating ON’ indicator display shows:
the boiler, 86 % efficiency, non- lights up. CAUTION
return valve opens at 55 °C OPEN SLOWLY!
- open the interior door Filling door 1 (centre) can now
proportionally).
- place wood lengthwise inside be opened.
the boiler, the logs parallel to Filling door 2 (top), the filling lid
The prerequisites for this are:
each other (not crosswise or and the ashes door remain
- correct heating according to
diagonally) closed!
the operating manual,
- close the interior door and the
- air-dried split logs (stored for 2
filling door - Open the interior door using
years), w = 20 % with calorific
If necessary, also place wood the operating hook
value approx. 4 kWh/kg
inside through filling door 2 or - Stir the fire bed to avoid the
the filling lid (type 60 L). Press formation of voids
The following order of events
the ‘Add fuel’ button, then after - Place wood lengthwise inside
must be adhered to when
15 seconds: the boiler, the logs parallel to
heating up the boiler:
- open filling door 2 and the each other (not crosswise or
- press the ‘Add fuel’ button.
interior door or the filling lid; the diagonally)
The following appears on the
boiler can be filled to the top - Close the interior door and
text display:
with wood filling door 1
DO NOT OPEN!
- close the interior door and - If necessary, also place wood
Please wait!
filling door 2 or the filling lid inside through filling door 2 or
- the induced draft fan operates
the filling lid.
at high speed and the ‘Add fuel’
Important information: Press the ‘Add fuel’ button;
indicator blinks
If the exhaust fume open after 15 seconds filling
- the door opener is released
temperature exceeds 300 °C door 2 and the interior door or
after 15 seconds and the
during the heating up process, the filling lid
following appears on the text
there is a danger of - The boiler can be filled to the
display:
overheating. top with wood
CAUTION
The following appears on the - Wait until the control switches
OPEN SLOWLY!
text display: automatically to the operating
Filling door 1 (centre) can now
Exhaust fume temperature mode ‘Heating ON’; the text
be opened.
too high [°C] ### display shows:
Filling door 2 (top), the filling lid
and the ‘malfunction’ indicator Heating
(60 L) and the ashes door
blinks. ON
remain closed!
Stop adding fuel immediately! and the ‘Heating ON’ indicator
When the fuel has been used lights up.
- open the interior door using
up, the control switches - Close the interior door and
the operating hook
automatically into the operating filling door 2
- switch off the induced draft
mode ‘Heating OFF’ and the - Unlatch the operating handle
fan by pressing the ‘Minus’
‘Heating ON’ indicator goes of the gas vent flap and close
button, place 2 to 3 small split
out. the flap.
logs inside, cover with kindling
Adding fuel
Additional control functions
Important information: O2 control program = standard
If the exhaust fume program with O2 probe Settings
temperature exceeds 300 °C TA control program = By selecting and confirming the
during the fuel addition alternative program in the event menu item
procedure, there is a danger of of a malfunction of the O2 probe SELECTION+_
overheating. SETTINGS
Set target values the settings menu is opened.
The following appears on the Display of the target values set
text display: by the user or the heating Setting the boiler set point
Exhaust gas temperature installer: The following appears on the
too high [°C] ### TK S = Boiler temperature text display:
and the ‘malfunction’ indicator (user) Boiler set point + _
blinks. TSmax = Max. storage tank TK S [°C] ##
temperature (installer) The value can be changed by
Stop adding fuel immediately! TSmin = Min. storage tank pressing the 'Plus' or 'Minus'
temperature (installer) button.
- Close the interior door and the TKmin = Min. boiler Setting range: 70 – 85 °C
filling door temperature (installer) The changed value is saved by
- Unlatch the operating handle O2 S = Residual oxygen content pressing the ‘Arrow’ button and
of the gas vent flap and close of the exhaust fumes the display gets to the next
the flap. (manufacturer) menu item.
CO2 S = Carbon dioxide content
Additional control functions of the exhaust fumes System settings
The Selection menu is entered (calculated from the O2 nominal The following appears on the
by pressing the 'Arrow' button value) text display:
and the following message Service code with +
appears on the display: Current actual values END
SELECTION+_ Display of the current actual The settings menu for the
INFORMATION values heating installer or the
The desired menu item can be TK I = Boiler temperature manufacturer is accessed by
selected by pressing the 'Plus' TS I = Storage tank pressing the ‘Plus’ button (more
or 'Minus' button. temperature detailed information can be
The selected menu item is TA I = Exhaust fumes found in the installation
confirmed by pressing the temperature manual).
‘Arrow’ button. O2 I = Residual oxygen content The settings menu is
The selection menu is of the exhaust fumes abandoned by pressing the
abandoned automatically if no CO2 I = Carbon dioxide content ‘Arrow’ button. The setting
button is pressed for more than of the exhaust fumes menu is abandoned
30 seconds. Lambda = Air ratio automatically if no button is
ETA-F = Combustion efficiency pressed for more than 30
Information seconds.
By selecting and confirming the Exhaust fume temperature
menu item Display of the highest exhaust
SELECTION+_ fume temperature reached.
INFORMATION
the information menu is called Operating hours
up and the following appears Display of the number of
on the text display: operating hours in the operating
Information + _ mode 'Heating ON'.
END
Standby hours
The following information can
Display of the proportion of
be displayed by pressing the
standby hours as a percentage
'Plus' or 'Minus' button.
of the operating mode ‘Heating
ON’.
Control program
Malfunction
Display of the control program
Display of the last malfunction.
according to which the
The Information menu is
combustion process is
abandoned by pressing the
controlled (automatic
‘Arrow’ button.
switchover).
Chimney sweep test and safety test
Unit test
Cleaning
Chimney sweep test and safety 8 Cleaning
test Aggregate test (Heating to ‘OFF’)
Only possible in the operating
mode 'Heating ON'. Only possible in the operating Removal of ashes
The chimney sweep test can be mode 'Heating OFF'. The ashes must be removed from
activated after the boiler has been For safety reasons, the aggregate the filling chamber and the ashes
cleaned, heated up and stoked up test may only be carried out when chamber regularly after 5 fillings
in accordance with the there is no fuel in the boiler. (but at least once a week).
regulations. By selecting and confirming the
By selecting and confirming the menu item Filling chamber
menu item SELECTION+_ After approx. five fillings, let the
SELECTION+_ AGGREGATE TEST boiler burn out completely and
CHIMNEY SWEEP TEST the test run is called up and the then clean the filling chamber floor
the ‘Chimney sweep test’ menu is function of the aggregates can be with the flat scraper and the
called up and the following tested. primary air apertures with the
appears on the text display: poker; clean out the ashes
CHIMNEY SWEEP TEST +_ The displayed function or through the grating in the flame
END displayed aggregate is switched duct. Do not remove the grating
By pressing the ‘Plus’ or ‘Minus’ on by pressing the ‘Plus’ button. during this procedure, as
button, it can be selected whether The displayed aggregate is otherwise the secondary air
the chimney sweep test should be switched off by pressing the apertures in the burner port can
performed at the rated power or ‘Minus’ button. get blocked by ashes!
with a partial load (emission You can progress to the next test Open the ashes door and remove
check) or whether the safety test step by pressing the ‘Arrow’ the ashes from the flame duct and
(check of the STL and thermal button. the boiler floor (tar coating on the
discharge safety device) should The test run can be ended side walls above the primary air
be performed. prematurely by pressing the apertures and on the rear wall of
The selected function is confirmed ‘Plus’ and ‘Minus’ buttons the boiler should not be
by pressing the ‘Arrow’ button. simultaneously. removed!); close the ashes door.
After that, heat up in accordance
The chimney sweep test at rated with the operating manual.
power, respectively with a partial
load is cancelled: Flame duct and ashes chamber
- at the end of 30 minutes, After around five fillings (but in any
- at a boiler temperature higher case once a week), the flame duct
than 88 °C (standby), and the ashes chamber must be
- in the operating mode ‘Heating cleaned of ashes using the flat
OFF’. scraper. If the boiler is not in
operation during the summer, it is
The safety test is finished: important that no ashes are left in
- if the ‘Plus’ button is not pressed the boiler (service life!)
for 30 seconds,
- if the safety temperature limiter Burner grating (weekly)
(STL) trips, Clean the floor of the filling
- at the end of 60 minutes chamber, lift out the grating using
- in the operating mode ‘Heating the hook and clean the secondary
OFF’. air aperture and grating support in
the burner. The secondary air
apertures in the burner port must
not be covered with ashes.
Replace the grating.
Cleaning the control
Maintenance
Important instructions
Ancillary heating surface Remount the air control unit Important instructions
(monthly) together with the seals (use new
Remove the cleaning lid, lift up the seals if need be), connect the Tripping of the thermal
exhaust fume baffle plate by about plugs again. discharge safety device
10 cm and fix it using the poker. If the maximum permissible boiler
Cleaning can now take place at temperature of 100 °C is
the rear and from the front through exceeded, the safety temperature
the ashes door using the scraper. Maintenance limiter (STL) interrupts the power
Push the exhaust fume baffle (Heating to ‘OFF’) supply to the fan (to switch on the
plate back down (otherwise STL again, refer to the
danger of overheating). Screw the Filling chamber ‘Troubleshooting’ section). If the
cleaning lid back on tightly. At the end of the heating period, boiler temperature continues to
clean the filling chamber floor and rise, the ‘thermo-mechanical
Induced draft fan (annually) the primary air apertures using the valve’ opens automatically via the
At the end of the heating season, scraper and poker. Remove ashes temperature sensor. Cold water
disconnect the fan from the mains and wood scraps. The tar coatings flows through the heat exchanger
by pulling the plug out of the on the walls of the filling chamber into the boiler and absorbs the
multiple socket. Unscrew the fan should not be removed. excess heat. As a result, the boiler
and clean the fan blades with a water is cooled down, preventing
brush (vacuum cleaner). Remount Door closure bolts a dangerous operating condition.
the fan and connect the plug The door closure bolts must be After cooling down, the system
again. oiled regularly. pressure, respectively the water
level in the system, must be
Air duct (annually) Sealing integrity of the doors checked and the water topped up
Unscrew the air duct and clean it If smoke escapes through the if necessary.
using the scraper and a vacuum doors, this is due to poor sealing
cleaner. caused by the sealing material Water level and water pressure
yielding. The doors are adjustable in the heating system
Cleaning the control on both the hinge and the closure Regular checks are necessary!
Before doing this, it is essential to sides and the sealing integrity can
turn off the main heating switch or therefore be restored. Protective functions
to disconnect the control from the The boiler must be cleaned
mains by disconnecting the mains Sealing integrity of the gas thoroughly if it is not to be fired for
plug. venting flap a longer period of time (for precise
The operating panel of the lambda The gas venting flap must lie information about this, please
control can be cleaned using a tightly against the frame for refer to the ‘Cleaning’ section).
moist cloth and a glass cleaning proper, low-emission operation Power supply must be guaranteed
agent. (see installation manual). also during the summertime via
the main heating switch (no
O2 probe (annually) Sealing integrity of the O2 probe continuous heating operation).
Detach the O2 probe by The screw fitting of the O2 probe The control can then perform the
unscrewing the cap nut, clean the must be checked for tightness (if integrated protective functions:
probe head with a hand brush, necessary carefully re-tighten venting of the boiler and protection
clean out the mounting tube and using a spanner). of the aggregates against seizing
carefully retighten the O2 probe up.
together with the seal (use a new Safety devices During the performance of the
seal if need be). The reliability performance of the protective functions, the following
safety devices must be checked appears on the display:
Air box (annually) once a year by the heating Protective functions
Disconnect the plugs for the two installer or by another authorised Please wait
air flap actuators and dismount the person. The safety valve and the
air control unit (but do not thermal discharge safety device
disassemble the control flap and must be checked. It is
actuator!) Clean the air box and recommended to take out a
the secondary air ducts using a service contract with a specialist
vacuum cleaner. firm!
Troubleshooting
Troubleshooting After rectification of the
The control recognises Loss of control data malfunction it must be
malfunctions automatically and Data loss acknowledged by pressing the
executes malfunction-related Control defective ‘Arrow’ button.
alternative programs or safety Cause: data memory in the
measures. control is defective. The control Exhaust fume temperature
There are two malfunction must be repaired by the too high
categories: the ‘malfunction’ manufacturer. Exhaust fume temperature
indicator either lights up too high [°C] ###
continuously or it blinks. ‘Malfunction’ indicator blinks Cause: exhaust fume
In the case of the following temperature has exceeded 300
‘Malfunction’ indicator lights malfunctions, the continuation °C.
up continuously respectively the switching on of Refer to pages 5 & 6 ‘Important
In the case of the following the heating function is possible instruction’.
malfunctions, the continuation until the malfunction has been
or switching on of the heating rectified: Work on the electrical
function is not possible and the The malfunction message is equipment may only be
malfunction indicator is shown on the text display in the carried out by a qualified
activated automatically: operating mode ‘Heating OFF’ electrician after
and after the ‘Arrow’ button is disconnecting the installation
Safety temperature limiter pressed: from the mains!
has tripped
STL tripped Measured oxygen values
Reset! Oxygen
Cause: boiler temperature is Measured values wrong
too high (no heat consumption, Causes: plug contact, probe
power failure, pump or valve cable, O2 probe dirty/worn or
defective). After the boiler screw fitting of the O2 probe and
temperature has dropped to protective tube is loose, control.
approx. 80 °C due to heat Check the O2 probe by means
consumption, the STL is reset of the aggregate test.
by pressing the restart switch, If the result of the aggregate
thus automatically test is ‘Probe OK’, then the
acknowledging the malfunction. malfunction is automatically
deleted.
Measured values of the Important instruction:
exhaust fume temperature Only perform the aggregate test
are incorrect if there is no fire or residual
Exhaust fume temperature embers in the boiler.
Measured values wrong
Causes: plug contact, sensor Measured values of the
cable, control, exhaust fume storage tank temperature are
sensor. After rectification of the incorrect
malfunction it will be Storage tank temp.
acknowledged by pressing the Measured values wrong
‘Arrow’ button. Causes: plug contact, sensor
cable, control, storage tank
temperature sensor.
After rectification of the
malfunction it must be
Measured values of the boiler acknowledged by pressing the
temperature are incorrect ‘Arrow’ button.
Boiler temperature
Measured values wrong Boiler temperature too low
Causes: plug contact, sensor Boiler temperature
cable, control, boiler too low [°C] ###
temperature sensor. After Causes: plug contact, cables,
rectification of the malfunction it non-return valve, actuator drive,
will be acknowledged by control.
pressing the ‘Arrow’ button.
Short operating instructions
of the lambda control
Operating condition ‘Heating OFF’ User: - general information
- setting the boiler
target temperature

Heating installer: - aggregate test


- system settings

TORRON 20
Short operating instructions
of the lambda control
Operating condition ‘Heating ON’ User: - general information
- setting the boiler
target temperature

Heating installer: - chimney sweep test


Notes