报警代码 Alarm 警报原因 Reason

警报内容 Alarm content 警报排除 Alarm exclusion


code for alarm

复位系统,手动模式下手

动正方向移动 Z 轴,松开
刀具前端露出长度

对刀仪过行程报警 Tool 主轴夹头,更换刀具 Reset


A1001 过长 The exposed
setter over-travel alarm the system, manually move
length of the tool tip
the Z axis in the positive
is too long
direction in manual mode,
loosen the spindle chuck,
and change the tool

没有外部气压输

入,机器强制停止

没有外部气压,机器强制
工作,保护风冷主 检查空压机或者气压管路

停止运行 Without
A1002 轴 Without external 是否异常 Check whether the
external air pressure, the
air pressure input, air compressor or air
machine is forced to stop
the machine is pressure pipeline is abnormal
running
forced to stop
working to protect
the air-cooled
spindle
A1003
主轴变频器报警 Spindle 主轴变频器故障 关闭机器,20 秒重新开

inverter alarm Spindle inverter


机,报警会自动清除。重
failure
新开机后,如果报警没有

清除,则打开后盖,查看

变频器故障代码 拍照并发

送给厂家 Turn off the

machine and restart it in 20


seconds, the alarm will be
cleared automatically. After
restarting, if the alarm is not
cleared, open the back cover,
check the inverter fault code,
take a picture and send it to
the manufacturer

开启对刀仪时对刀仪处

对刀仪信号故障
于触发状态 The tool 更换对刀仪 Replace the tool
A1004
Tool setter signal
setter is in the trigger state setter
failure
when the tool setter is
turned on

外部气压输入压力 检查空压机或者气压管路
外部气压压力不足
A1005 不足 Insufficient 是否异常 Check whether the
Insufficient external air
pressure external air input air compressor or air
pressure pressure pipeline is abnormal
A3413
对刀中检测到刀号非法 刀库异常 Tool 重置刀库 Reset the tool

Illegal tool number magazine abnormal magazine


detected during tool
setting

对刀点 Z 加[最长刀长]

加[安全距离]超出了 Z

刀库异常 Tool 重置刀库 Reset the tool


A3562 正软限位 The tool setting
magazine abnormal magazine
point Z plus [longest tool
length] plus [safety
distance] exceeds the Z
positive soft limit

XYZ 轴未回零,不能进行

刀长测量 The XYZ axis 机器未回零 The


A3566 回零操作 Zero operation
has not returned to zero, machine does not
and the tool length return to zero
measurement cannot be
performed

主轴当前刀号与指定的

测量刀号不一致 The
刀库异常 Tool 重置刀库 Reset the tool
A3569
current tool number of the
magazine abnormal magazine
spindle is inconsistent
with the specified
measurement tool number
A3570
刀长连续测量误差过大, 对刀仪需要清洗或 检测对刀仪 Detect tool

setter
可能对刀仪有脏污 The 者故障 The tool
continuous measurement
error of the knife length is setter needs cleaning
too large, and the tool or malfunction
setter may be dirty

快速移动时触碰到了对

刀仪,可能被测量的刀长

刀具露出长度过长
大于[最长刀长]The tool
检查刀长 Check the length
A3571 The exposed length
setting instrument was
of the tool is too of the knife
touched during rapid
long
movement, and the
measured tool length may
be greater than [longest
tool length]

慢速探测前已触碰到了

对刀仪,可能[回退量]太

刀库异常 Tool 重置刀库 Reset the tool


A3572 小 The tool setting
magazine abnormal magazine
instrument has been
touched before the slow
detection, and the [retract
amount] may be too small
A3574
测量刀长值与系统刀长 刀具破损或者断刀 更换刀具 Change tool

Broken or broken
值的差值超出范围,可能
tool

已磨损或断刀 The
difference between the
measured tool length
value and the system tool
length value is out of
range, and the tool may
be worn or broken

没有感应到探测信号,可

能已断刀或者对刀器信
刀具破损或者断刀
A3575 更换刀具 Change tool
号无效 No detection Broken or broken
tool
signal is sensed, the tool
may be broken or the tool
setter signal is invalid

长补偿表的值与断刀检

测值偏差较大,请更新断

刀检测值 The value of 刀具破损或者断刀


A3577 更换刀具 Change tool
the long compensation Broken or broken
table has a large deviation tool
from the broken tool
detection value, please
update the broken tool
detection value
A3578
空刀检测异常,可能还刀 刀库异常 Tool 重置刀库边检查刀库上的

magazine abnormal
失败 The empty knife 刀具是否异常 Reset the tool

detection is abnormal, and magazine and check whether


the tools on the tool
the tool may fail to return
magazine are abnormal

指令刀号不在范围 T0~
输入错误的换刀指
检查输入的换刀指令 Check
T6Command tool number
A3579
令 Input wrong tool the input tool change
is not in the range T0~
command
change command
T6

当前刀号不在范围 T0~
当前刀号错误
T6The current tool 重置刀库 Reset the tool
A3580
number is not in the range Current tool number
magazine
error
T0~T6

A*****
伺服报警 Servo alarm 伺服驱动器报警 自动模式下,复位机器,

Servo drive alarm


报警清除,如果无法清除

则关闭机器,20 秒重新开

机,报警会自动清除。重

新开机后,如果报警扔没

有清除,拍下界面上的伺

服报警代码内容,并发送

给厂家。In automatic mode,

reset the machine and the


alarm will be cleared. If it
cannot be cleared, turn off
the machine, restart it in 20
seconds, and the alarm will
be cleared automatically.
After restarting, if the alarm
is not cleared, take a picture
of the servo alarm code
content on the interface and
send it to the manufacturer.

You might also like