Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Engineering

I2006
Insulation specification
Project name: DAMMAM ISTP
Project number:

Rev Description By Date Approved


by
0 For comments Karthik 08-08-21

Administrator of this document is:

Revisions to this document must be reviewed by:

Reviewed version of this document must be approved by: European Reliability COE

Document Company Country Revision Date Page


I2006-Insulation specifications.doc Saudi Boiler 0 08-08-2021 1 of 3
This document contains Trade Secret Information. Disclosure, use or reproduction outside Saudi Boiler, and inside
Saudi Boiler to or by those employees who do not have a need to know, is prohibited except as authorized by Saudi
Boiler in writing.
Insulation specification Index

1 PRESCRIPTION ....................................................................................................................................................... 3
1.1 CLASS 1 ................................................................................................................................................................... 3

Document Company Country Revision Date Page


I2006-Insulation specifications.doc Saudi Boiler 0 08-08-2021 1 of 3
This document contains Trade Secret Information. Disclosure, use or reproduction outside Saudi Boiler, and inside
Saudi Boiler to or by those employees who do not have a need to know, is prohibited except as authorized by Saudi
Boiler in writing.
Insulation specification

1 Prescription
1.1 Class 1
55

50

45

40
Insulation thickness

35

30

25

20

15

10

0
10 15 20 25 32 40 50 65 80 100 150 200 250 300
Piping diameter (DM)

In this class all pipelines fall with a medium temperature to 100 degrees.

All parts of a system that are fixed to the insulated objects must be insulated with the same insulating thickness as the part
such as rings, rods etc.

Between the casing surface and an obstacle there should be a minimum area kept of 50 mm.

R.V.S. apparatus with an average working temperature of at least 60 degrees should always be pre treated.

Name Measurement
(DN)
Personal protection 10 - 300
General demands

Thermal insulation
General demands
Insulation material 10 - 300
Sheet material 10 - 300
Swages 10 - 300

Pipes 10 - 300
Elbows 10 - 80
100 - 300
Flanges 10 - 300
Valves 10 - 300
Expansion bellows 10 - 300

Pipe supports 10 - 300

T-pieces 10 - 300
Reducers 10 - 300

Flat faces 10 - 300


Lead through 10 - 300

Cut-outs
Expansion 10 - 300
Sealing
Walk ability 10 - 300
Tracing 10 - 300

Document Company Country Revision Date Page


I2006-Insulation specifications.doc Saudi Boiler 0 08-08-2021 1 of 3
This document contains Trade Secret Information. Disclosure, use or reproduction outside Saudi Boiler, and inside
Saudi Boiler to or by those employees who do not have a need to know, is prohibited except as authorized by Saudi
Boiler in writing.

You might also like