Pump Control (Output Flow) - Adjust


SMCS - 3222-025-FW

Adjust the pump output flow if the flow test results differ greatly from the specifications.

Pump Output Flow Adjustment

Illustration 1 g00451617

Pump compartment

(1) Setscrew

(2) Locknut

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 24/01/2012
PDF created with pdfFactory Pro trial version www.pdffactory.com
318B L & 318B LN Excavators 3LR00001-UP (MACHINE) POWERED BY 3046 En... Página 2 de 3

(3) Setscrew

(4) Locknut

(5) Locknut

(6) Setscrew

(7) Setscrew

(8) Setscrew

(9) Setscrew

Adjust the flow of the front pump.

1. Loosen locknut (4) .

2. Turn setscrew (3) in order to adjust the output flow of the pump. Turning setscrew (3) clockwise
will increase the output flow of the pump. Turning setscrew (3) counterclockwise will decrease
the output flow of the pump. A 1/4 turn of setscrew (3) will change the output flow of the pump at
the following pressure.

¡ The pressure range of the first regulator spring is 15700 kPa (2300 psi) to 18600 kPa (2700
psi). Output flow of the pump will change approximately 10.7 L/min (2.8 US gpm) if the
output flow is adjusted in this pressure range.

3. Tighten locknut (4) to a torque of 155 ± 20 N·m (115 ± 15 lb ft).

4. Loosen locknut (2) .

5. Turn setscrew (1) in order to adjust the output flow of the pump. Turning setscrew (1) clockwise
will increase the output flow of the pump. Turning setscrew (1) counterclockwise will decrease
the output flow of the pump. A 1/4 turn of setscrew (1) will change the output flow of the pump at
the following pressure.

¡ The pressure range of the second regulator spring is 24520 kPa (3550 psi) to 29400 kPa
(4250 psi). Output flow of the pump will change approximately 5.0 L/min (1.3 US gpm) if
the output flow is adjusted in this pressure range.

6. Tighten locknut (2) to a torque of 16 ± 2 N·m (12 ± 1 lb ft).

7. Adjust the rear pump in the same manner as the front pump adjustment. Use setscrew (8) and
setscrew (9) instead of setscrew (3) and setscrew (1) to adjust the rear pump.

Adjustment of the Maximum Output Flow of the Pump


Adjust the maximum output flow of the front pump.

1. Loosen locknut (5) .

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 24/01/2012
PDF created with pdfFactory Pro trial version www.pdffactory.com
318B L & 318B LN Excavators 3LR00001-UP (MACHINE) POWERED BY 3046 En... Página 3 de 3

2. In order to adjust maximum output flow, turn setscrew (6). Turning setscrew (6) clockwise will
decrease the maximum output flow of the pump. Turning setscrew (6) counterclockwise will
increase the maximum output flow of the pump. When setscrew (6) is turned by 90 degrees, the
flow changes approximately 3.2 L/min (0.8 US gpm).

3. Tighten locknut (5) to a torque of 130 ± 10 N·m (95 ± 7 lb ft).

4. Adjust the maximum output flow of the rear pump in the same manner as the front pump
adjustment. Use locknut (5) and setscrew (7) instead of locknut (5) and setscrew (6). Repeat Steps
1 through 3.

Copyright 1993 - 2012 Caterpillar Inc. Tue Jan 24 21:04:39 EST 2012
Todos los derechos reservados.
Red privada para licenciados del SIS.

https://127.0.0.1/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb... 24/01/2012
PDF created with pdfFactory Pro trial version www.pdffactory.com

You might also like