RANGE OF SMART IOT GATEWAYS & DEVICES

SMART IOT SYSTEM


SIS4G485 SIS4D048 SIS4TRH SIS4WTRH
• GSM connectivity (4G) • MQTT (JSON) Protocol
• GSM connectivity (4G)
• MQTT (JSON) Protocol • GSM & WiFi
• MQTT (JSON) • GSM connectivity (4G) connectivity
• SMS, E-mail &
• Dual SIM Slot for • MQTT, HTTP, TCP-IP Voice Call alerts • Dual SIM Slot for
Network Redundancy (JSON) Protocol • Dual SIM Slot for Network Redundancy
•Settable Alarms Network Redundancy • Universal Data Type
• Dual SIM Slot for • Settable Alarms
• 32- Nodes MODBUS RTU • 48- Nodes •Settable Alarms
Network Redundancy •2 inbuilt sensors Temp.
• SMS, E-mail & Voice Call alerts MODBUS RTU • 2 inbuilt sensors Temp.
• Isolated RS-485 Input & Output (optional) • Isolated RS-485 • Universal Data Type • Isolated RS-485 Input & RH + 30 Nodes • Isolated RS-485 Input
& RH+46 Nodes
• Network Failure Logging Input •Network Failure Logging •Network Failure Logging •Network Failure Logging

SMART IOT SYSTEM SMART IOT PORT


SISWD485 SISWDTRH SISLTRH SIP4DRS
• MQTT, HTTP, TCP-IP
• MQTT(JSON) Protocol • MQTT(JSON) Protocol (JSON) Protocol
• 48 Nodes MODBUS RTU • WiFi connectivity • Cloud connectivity • Dual SIM Slot for
via Gateway Network Redundancy
• WiFi connectivity • 2 inbuilt sensors
Temp. & RH + 46 Nodes • LoRa connectivity • SMS, E-mail &
• Isolated RS-485 Input • 2 inbuilt sensors Voice call alerts
• Isolated RS-485 Input • 28 MODBUS slaves
•Network Failure Logging •Network Failure Logging Temp. & RH +4Digital inputs •Settable Alarms
•Settable Alarms • Isolated RS-485 • Universal Data Type
Input and output •Network Failure Logging

SMART IOT GATEWAY - WEATHERPROOF


SIG4LRN-WP SIG4GTY-WP SIGWGTY-WP
• 48 Compatible Nodes • 48 Compatible Nodes
• Dual 4G SIM slot for • Dual 4G SIM slot for • 48 Compatible Nodes
Network Redundancy Network Redundancy • MQT T (JSON)
• I/P communication LoRa • Isolated RS-485 Input & Output • WiFi connectivity
• Isolated RS-485 output
SIG4LRN • MQT T (JSON) • Isolated RS-485 Input & Output
• MQT T (JSON) SIG4GTY

• SMS & E-mail alert


SIGWGTY

• 4-DPDT relays for • 4-DPDT relays for control action


control action • 4-DPDT relays for control action
• SMS & E-mail alert via cloud
• Pendrive Data logging • Pendrive Data logging

SMART IOT GATEWAY - MS


SIG4LRN-MS SIG4GTY-MS SIG2MCM-MS
• 48 Compatible Nodes •48 Compatible Nodes
• Isolated RS-485 output •Dual 4G SIM slot for • 70 Compatible Nodes
• Dual 4G SIM slot for Network Redundancy
Network Redundancy • Isolated RS-485 Input & Output
•Isolated RS-485 Input & Output
• I/P communication LoRa • 4-DPDT relays for control action
• MQT T (JSON)
• MQT T (JSON) • Graphical L.C.D. Display
• 4-DPDT relays for control action
• 4-DPDT relays for control action
• SMS & E-mail alert • Pendrive Data logging
• Pendrive Data logging • Pendrive Data logging

SMART IOT GATEWAY - FLAMEPROOF


SIG4LRN-FLP SIG4GTY-FLP SIG2MCM-FLP
• 48 Compatible Nodes • 48 Compatible Nodes
• Dual 4G SIM slot for Network • 70 Compatible Nodes
• Dual 4G SIM slot for Network
Redundancy Redundancy • Isolated RS-485 Input & Output
SIG4LRN

• MQT T (JSON) • MQT T (JSON) • 4-DPDT relays for control action


• I/P communication LoRa • Isolated RS-485 Input & Output
• Isolated RS-485 output • Graphical L.C.D. Display
• 4-DPDT relays for control action
• 4-DPDT relays for • Pendrive Data logging
control action • SMS & E-mail alert
• Pendrive Data logging • Pendrive Data logging

SMART IOT GATEWAY RECEIVER WIRELESS GAS DETECTORS FOR METHANE / TOXIC / COMBUSTIBLE
SIG4RCV-WP WGD4MSB-FLP WGD4MSP-FLP WGD4MSS-FLP
•32-Node of WGD series To Solar
•Dual SIM slot for
Network Redundancy
•7V to 24V DC (SMPS)
•MQTT (JSON)
• MODBUS RTU & • Dual 4G SIM slot for
•Battery operated Network Redundancy
TCP-IP Protocol
•Upto 6+ months battery life • Inbuilt Hooter cum Flasher •Solar operated •Battery charging facility
• 4 DPDT Relays
• SMS Facility to central unit and users • SMS Facility to control unit and users
• Graphical L.C.D. Display • Dual 4G SIM slot for Network Redundancy • SMS Facility to control unit and users • Dual 4G SIM slot for Network Redundancy
• Pendrive data logging • Graphical L.C.D. Display • IP-66 Enclosure • Graphical L.C.D. Display • IP-66 Enclosure • Graphical L.C.D. Display • IP-66 Enclosure
2
INDUSTRIAL IOT PRODUCT RANGE
Smart IoT System Smart IoT Port
Model No.: SIS4G485 SIS4D048 SISWD485 SIS4TRH SISWDTRH SIP4DRS

Product
Specifications
No of Channels/Process Values 30 MODBUS slaves 46 MODBUS slaves 28 MODBUS slaves
32 48 48 2 (inbuilt Temp.& RH sensor) 4 Digital inputs
Connectivity
ii) GSM / GPRS
ii) WiFi (on request)
iii) LORA (on request)
SIM Card Slots 02 NOS 02 NOS 02 NOS 02 NOS
Input
•RS-485 MODBUS RTU
•Digital Input (Wet / Dry Contact) 4DI
• Temperature & Humidity Sensor (on request)
Output
• RS-485 MODBUS RTU
(on request) (on request) (on request) (on request)
• MODBUS TCP/IP (Optional) (on request) (on request) (on request) (on request)
• Digital Output (Relay) 4DO
Universal Data Types
L.E.D. Indication 04 NOS 04 NOS 04 NOS 04 NOS 04 NOS 12 NOS
Alarm & Notification
ii) Email - 05 Email Address (from
(from AmbeIIoT Cloud)
ii) SMS - 10 Mobile Nos AmbeIIoT Cloud)
iii) Scheduled Email Reports
iv) Voice Call - 10 Mobile Nos
Failsafe Memory

Buzzer
GPS (Optional)
Data Interval 1 to 60 min
Data Logging Records 50,000 15,000 15,000 50,000 15,000 50,000
Event Logging Records 15,000 15,000 15,000
MQT T (JSON), HTTP, MQTT (JSON), HTTP,
Communication Protocol MQTT (JSON) TCP-IP MQTT (JSON) MQT T (JSON) MQT T (JSON) TCP-IP
SMS Configuration/ SMS Configuration/ SMS Configuration/
Device Configuration AEPL IIoT Software AEPL IIoT Software AEPL IIoT Software AEPL IIoT Software AEPL IIoT Software AEPL IIoT Software

Settable Alarms per Channel 2 2 2


Supply Voltage 9V to 24VDC Adaptor
Environmental • Operating Temp. : -10° to 50°C • Storage Temp. : -20° to 60°C • Humidity : Less than 95% Non-Condensing
Housing : Cabinet Material ABS Plastic
Dimension : (W) x (H) x (D) in mm 150 x 90 x 55 120 x 90 x 55 150 x 176 x 55 120 x 176 x 55 190 x 90 x 55
Weight : in Grams 270 Gm Approx. 500 Gm Approx.
Mounting Wall Mount
3
SMART IoT GATEWAY
Smart IoT Gateway
Model No.: SIG4GTY- WP SIGWGTY- WP SIG2MCM - WP SIG4LRN - WP

SIG2MCM
SIG4LRN

Product SIG4GTY
SIGWGTY

Specifications

No of Channels/Process Values 48 48 70 48
Connectivity
ii) GSM (4G) / GPRS
ii) WiFi (On Request)
iii) LORA
SIM Card Slots 02 Nos. 02 Nos.
Input
ii) RS-485 MODBUS RTU
Output
ii) RS-485 MODBUS RTU
ii) MODBUS TCP/IP (Optional) (On Request)
iii) Digital Output (Relay)
Universal Data Types
L.E.D. Indication 4 4 3 4
L.C.D. Display (128 mm x 64 mm)
Alarm & Notification
ii) Email - 05 Email Address
(from
ii) SMS - 10 Mobile Nos
AmbeIIoT Cloud)
Failsafe Memory
Buzzer
GPS (Optional)
Data Interval 1 to 60 min 1 to 60 min NA 1 to 60 min
Communication Protocol MQT T (JSON) MQT T (JSON) NA MQT T (JSON)
Device Configuration AEPL-IIoT PC Software
Inbuilt RTC
Settable Alarms per Channel 2 2 2 2
Pendrive Interface
Repeaters
Supply Voltage
12V / 24V DC
Environmental
ii) Operating Temperature -10° to 50°C
ii) Storage Temperature -20° to 60°C
Housing : Cabinet Material
ii) Polycarbonate, Grey colour (WP)
ii) Cast Alluminium Alloy, LM-6 (FLP) Available Available Available
(PESO approved) (PESO approved) (PESO approved)
iii) Metal Sheet Grey Colour (MS) Available Available Available
iv) Protection Class :
1) IP-65 2) IP-66 3) IP-54 IP 65 IP 65 IP 65 IP 65
Dimension : (W) x (H) x (D) in mm 365 x 317 x 160 365 x 317 x 160 365 x 317 x 160 365 x 317 x 160
Weight : in Grams 1 Kg. 1 Kg Approx.
Mounting Wall Mounting
4
CONVERTERS
Converters
Model No.: ERS-485 ERS-232 RS-232 to RS-485 RS-485 TO USB LRS-485

RS232 - 485
RS-232 TO RS-485 CONVERTOR

Product RS-232

9V-24VDC
+ - TX
RS-232
RX SH D+
RS-485

RS-485
D- SH

Specifications

Input (as per application)


ii) RS-485 MODBUS RTU

ii) RS-232 (as per application)


iii) MODBUS TCP/IP (Configurable) (Configurable)

iv) USB

v) LoRa Wireless

Output
ii) RS-485 MODBUS RTU (Configurable) (as per application) (as per application)

ii) RS-232 (Configurable)

iii) MODBUS TCP/IP

iv) USB

v) LoRa Wireless
L.E.D. Indication 2 2 2 2 2
BAUD Rate
9600 bps to 115200 bps

Parity
None, Even, Odd
Data Bits 8 8 8 8 8
Configuration AEPL Software
Inbuilt HT TP WEB Server
(Windows)
Interface Type
Input DB-9 pin (Female)/ D+, D-, SH/ D+, D-, SH/ D+, D-, SH/
D+, D-, SH/RJ45
RJ 45 RX, TX, GND USB Wireless
Output
Supply Voltage
9V to 24VDC Adaptor (From PC)
5 VDC Adaptor
Environmental
ii) Operating Temperature -10°C to 50°C

ii) Storage Temperature -20°C to 60°C


iii) Humidity Less than 95% Non-Condensing
Housing :
Cabinet Material
ii) ABS Plastic
Dimension : (W) x (H) x (D) in mm 59 x 101 x 23 41 x 78 x 24 59 x 101 x 23 40 x 70 x 20 59 x 130 x 23
Weight : in Grams 200 Gm Approx 100 Gm Approx 250 Gm Approx 100 Gm Approx 250 Gm Approx
Mounting Din rail NA Din rail NA Din rail
5
APPLICATIONS
Comprehensive Solution for Wireless Gas Detection & Control

•SMS
•E-mail

Cloud
Dashboard 12VDC Solar Panel

ambeiiot.com
MQT T Broker
NODE-1 NODE-2

WGD4MSB-FLP WGD4MSS-FLP
• Battery operated • Solar operated
• Upto 6+ months battery life • Battery charging facility
• Daily status & Fault SMS facility to central Unit & Users • SMS Facility to central unit and users
• Dual 4G SIM slot for Network Redundancy
• Dual 4G SIM slot for Network Redundancy
• Graphical L.C.D. Display
• Graphical L.C.D. Display
• Low battery Indication
• IP-66 Enclosure • Low battery Indication
NODE-3 • IP-66 Enclosure

.......NODE-32
CENTRAL UNIT
(SIG4RCV-WP)
•32-Node of WGD series
WGD4MSP-FLP
•Dual SIM slot for Network Redundancy
• 7V to 24V DC (SMPS)
•MQTT (JSON)• MODBUS RTU or TCP-IP Protocol
• Dual 4G SIM slot for Network Redundancy
• Inbuilt Hooter cum Flasher • 4 DPDT Relays
WGD4MSB-FLP
• SMS Facility to central unit and users • Graphical L.C.D. Display
• Battery operated
• Graphical L.C.D. Display • Encrypted Data format received from WGD • Upto 6+ months battery life
• IP-66 Enclosure • Pendrive data logging • SMS Facility to central unit and users
• Alarm actions may include: • Dual 4G SIM slot for Network Redundancy
• Graphical L.C.D. Display
- Alarm status on display
ETHERNET/RS-485 • IP-66 Enclosure
- Relay activations
• MODBUS RTU
- Buzzer activation
• MODBUS TCP-IP
- LED Indication
• MODBUS Over TCP-IP

SMS Alerts
Via WGD-100

SMART LOG PRO SOFTWARE

• SCADA
• PLC
• PC
•ANY MODBUS MASTER

CONTROL ROOM STATUS -OK -SMS STATUS-AL-1 HIGH STATUS-AL-1-2 :HIGH


6
APPLICATIONS
Cold Chain Monitoring System
• SMS Cloud Dashboard
Applications :
• E-mail
• Ambient Room Temp. & RH Monitoring
• Cold Room
• Warehouse
GS
iF i M+

GS
• Chiller and Freezer +W WiF
GSM

M
i

+W
• HVAC

iFi
• Medical Industry
• Pharma and Food Industry
• Chemical Industry
• Agriculture Industry
• Power Plant
SIS4WTRH-1 SIS4WTRH-2 SIS4WTRH.................nth

Energy Management System


Cloud Dashboard
• SMS
• E-mail

SIS4D048

GSM/GPRS
9V to 24VDC
Adaptor

RS-485 MODBUS RTU


Energy Chiller AHU UPS DG sets
Meters

Wireless Temperature & Humidity Monitoring System


Gas Detector
GT-2511-FLP
LRS - 485
RS-485 TO WIRELESS TRANSCEIVER

LRS-485
n
c atio
muni
Com
LoRa

Smart IoT System Smart IoT System Smart IoT System


(NODE-4) (NODE-3) (NODE-2)
SIG4LRN

Smart IoT Gateway


SISLTRH SISLTRH SISLTRH
(SIG4LRN) 7