True Rms Clamp Meter Specifications

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 3

True Rms Clamp Meter Specifications

Specifications Offering
GENERAL FEATURES Type Hand held
Display 3 digit Backlit LCD, 3.5
digit Backlit LCD, 4
digit Backlit LCD, 4.5
digit Backlit LCD
Measurement Type True RMS
count 3000, 4000, 6000,
10000
MEASUREMENT Resistance 4, 10, 100, 1000
FEATURES Measurement Range kiloOhm
Resistance 0.5, 1, 1.5, 2 percent
Measurement
Accuracy (+/-)
Frequency 0.5, 1, 10, 100, 500
Measurement Range kiloHertz
Frequency 0.5, 0.3, 0.1 percent
Measurement
Accuracy (+/-)
AC Current 10, 100, 1000 Ampere
Measurement Range
AC Current 1, 1.5, 2, 2.5 percent
Measurement
Accuracy (+/-)
AC Voltage 400, 600, 750, 1000
Measurement Range Volt
AC Voltage 1.5, 1, 2 percent
Measurement
Accuracy (+/-)
DC Current 100, 1000 Ampere
Measurement Range
DC Current 1.5, 2, 1 percent
Measurement
Accuracy (+/-)
DC Voltage 0.4, 4, 40, 400, 1000
Measurement Range Volt
DC Voltage 1, 1.5, 2 percent
Measurement
Accuracy (+/-)
Other features,if
applicable
GENERIC Jaw Size (Dia in 30, 32, 34, 36, 38, 40,
Closed State) 42, 48, 51 millimeter
Dimensions (H x W x
L) (mm x mm x mm)
Weight Range: [-9999999-
9999999] gram
POWER Power Battery Operated
REQUIREMENTS Requirements
Type of Battery Rechargeable, Non-
Rechargeable( Alkaline
), NA
if rechargeable , Lithium ion, Ni- MH,
then chemistry of SMF, NA
the battery
if Non- AA, AAA, 9-V
rechargeable , then rectangular battery,
size of the battery / NA
cell
Number of non- 1, 2, 3, 4, NA
rechargeable the
battery / cell
Voltage of Range: [-9999999-
rechargeable 9999999]
Battery
milliamphere hour
Suitable Yes, NA
charger/adaptor
provided
OPERATING Minimum Operating -5, -10, 0, 5, 10 degree
CONDITION Temperature Celsius
Maximum Operating 40, 45, 50, 55 degree
Temperature Celsius
Operating Humidity 80, 90 percent
(RH)
SAFETY Safety Certification UL, CE, CSA, TUV
Safety Rating CAT III 6000 V of IEC
61010 -2-D31, CAT III
300 V of IEC 61010 -2-
D31
ACCESSORIES Details of the
Standard
Accessories
Supplied with the
Equipment
SERVICE Warranty 1, 2, 3 Year
TEST REPORT The equipment Yes
DETAILS & TESTS supplied with
calibration
certificate
conformity to Dry Yes, No
Heat for 16 hrs at a
specified maximum
temp
conformity to Cold Yes, No
Test for 4 hrs at a
specified minimum
temp in accordance
with
IS:9000/part-2/sectio
n-4/1977 latest
conformity to Damp Yes, No
Heat (Cyclic)Test for
2 Cycles of 24 h each
at a temp of 40
degree C & 95% RH
Availability of Test Yes, No
Reports from
Central
Govt/NABL/ILAC
approved accredited
lab to prove
conformity to the
specification
Test Report Number
and date for the
specification test
Name and address
of the Lab for the
specification test

You might also like