Commented - GS Control Offer of LT PANELS

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

GS CONTROL PRIVATE LIMITED

Manufacturing of LT & HT Electrical Panel, Servo Stabilizer , Distribution Transformers


Regd Office :- C - 53, SECTOR – 63, Noida, UP-201301
Email :-info@gscontrolindia.com, gscnotrolindia@gmail.com
Website :-www.gscontrolindia.com, Cont. :- 0120-4240040, +91-8470087966
8470087966
PAN – AAICG0333P
G0333P GST - 09AAICG0333P1ZB IEC - AAICG0333P

OFFER NO: GS/2023


023-24/0594 Date: 29.03.2024

Project: -

Contractor:- NARAYAN AND BHOPJI

Cont:-

Kind Attn:- Mr. Satyendra Singh

Email:- satyendra.singh@saatvikgroup.com

Sub: - SUBMISSION OF OFFER FOR LT PANELS

Dear Sir/Ma’am,
We acknowledge with th thanks in receipt of your enquiry of LT PANEL. In response we are
pleased to submit our offer as under:

A. Bill of Material ( As per Annexure - I )


B. Commercial Terms ( As per Annexure - II )
C. Technical Terms ( As per Annexure – III )
D. Price Schedule ( As per Annexure – IV )

Hope you will find our offer competitive and would favor us with your valuable order. Please feel
Looking for a favorable response,
Sincerely,

For GS CONTROL PVT. LTD.

Technical Concern Person:


GAUTAM MISHRA
(+91-8448859817)

Service Partner of
Annexure - I
Bill Of Material

Sr. No. DESCRIPTION MAKE QTY.


11KV VCB

11kV, 630Amp. 26.3kA/3sec. EDO VCB


1 No. Closing Coil : 110V DC
1 No. Shunt Trip Coil : 110V DC Additional
Shunt Trip Coil : 110V DC
1 No. Spring Charge Motor : 230V AC
Automatic Safety Shutters
Operation Counter ABB 1
25A Standard Mounting TNC Switch,
AuxContact: 2NO+2NC CG/CS 1

NUMERICAL PROTECTION RELAY, HAVING


FOLLOWING Make should be ABB,
PROTECTIONS 3O/C Schneider or Simens
+ 1 E/F HIGH SET TRIP CIRCUIT SUPERVISION
RELAY
COMMUNICATION PORT(50,51,50N,51N, 86,
27, 59, 74, 74TC, 81
U/O, 95, 80 DC, 80 AC) CG/C&S 1
Single element Lockout (Mater Trip) Relay with
Hand reset contact
and Flag, Contacts: 3NO+2NC, Aux. Supply:
230V AC C&S/CG 1
Two element Auxiliary Relay, self reset
contacts with operation
indicator, Flush mounting , Contact:
12.01.2022, Voltage:
24/30/48/110/220/250V DC C&S/CG 3
4A Auxiliary Contactor, Coil: 24V DC, Aux.
Contact: 2NO+2NC, Type:
MX0 22E C&S/CG 2

CURRENT TRANSFORMER DUAL RATIO, DUAL


CORE SINGLE Phase
TYPE : RESIN CAST 11kV 150/1-1A
RATIO : 275/1-1 A
CORE-1 : CL-0.2s, 15VA SAVIO/AVCO
CORE-2 : CL-5P20, 15VA N 3
Open delta core is
POTENTIAL TRANSFORMER, FlXED TYPE SINGLE seperated core with
PHASE CL:3P, refer SLD for
TYPE : RESIN CAST better understand
RATIO : 11kV/r3
CORE-1 : CL-3P OPEN DELTA CORE
CORE-2 : CL-0.2 SAVIO/AVCO
BURDEN :30VA N 3
Power Pack 17AH DC 110V REPUTED 1

Multifunction Meter with RS485, LCD Display,


3Ph, Parameter: VAF
+ THD (V & I), Imp-Exp kWh & kVAh + PF + kW
+ THD (Power) +
RPM + kVAR + kVA + Ph. Angle + Power On/Off
+ Cumulative MD +
Imp-Exp kVARh, Acc. CL: 0.2s, Aux. Supply: 80-
300V AC/DC, Size:
96x96, Model: Elite 446 SECURE 1
Three Phase Ammeter, Acc. Cl: 0.5, Model:
DM3110 SCHNEIDER 1
Three Phase Voltmeter, Acc. Cl: 0.5, Model:
DM3210 SCHNEIDER 1
Red Gen Next Pro LED Indicator 22.5 mm,
Voltage: 64V AC/DC ESBEE 3
Yellow Gen Next Pro LED Indicator 22.5 mm,
Voltage: 64V AC/DC ESBEE 2
Blue Gen Next Pro LED Indicator 22.5 mm,
Voltage: 64V AC/DC ESBEE 2
Green Gen Next Pro LED Indicator 22.5 mm,
Voltage: 110V AC/DC ESBEE 1
Amber Gen Next Pro LED Indicator 22.5 mm,
Voltage: 110V AC/DC ESBEE 1
Blue Gen Next Pro LED Indicator 22.5 mm,
Voltage: 110V AC/DC ESBEE 1
White Gen Next Pro LED Indicator 22.5 mm,
Voltage: 110V AC/DC ESBEE 2
Red Mushroom Head(Push - Turn) Push Button
22.5 mm ESBEE 1
1NO Contact Block ESBEE 3
1NC Contact Block ESBEE 1
10A Toggle Switch 230V AC FTC 1
6A 2P 2Way Local - Remote/ Auto-Manual
Switch with Center OFF,
60 Deg. Operation ABB/L&T 1
4 Sq.mm Fuse Terminal (Std. Color),Type:
UBDF 4 ELMEX 3
2.5 Sq.mm Feed Through Terminal (Std.
Color),Type: KUT 2.5 ELMEX 60
4 Sq.mm Disconnecting Terminal (Std.
Color),Type: KLTD M4 ELMEX 6
Glass Fuse 2A Reputed 3
32A Neutral Link, Channel Mounting, Color:
Black/Grey FTC 1
6A 1P 10kA, C-Curve MCB L&T 6
6A 2P 10kA, C-Curve MCB L&T 4
20A 2P 10kA, C-Curve MCB L&T 1
16 windows Reputed 1
Hooter Reputed 1
Door Switch With Openable Execution Push
Rod Reputed 1
Switch And Socket 15A, 5PIN Anchor 1
Panel Illumination LED Light Reputed 1
Thermostate Reputed 1
Space Heater Reputed 1
11KV Insulator Powermat 3
SURGE ARRESTOR CLASS 2,10KV 10KA WITH
FUSE Reputed 3
PT FUSE Reputed Panel with3 canopy
Earthing Switch Reputed and double1 door for
outdoor application.
Panel Enclosure 14/16 Gauge(OUTDOOR)-IP55 EXPERT 1

BUSBAR - MAIN 1
BUSBAR - VERTICAL DROPPER BUSBAR 1
BUSBAR - EARTH 1

Sr. No. DESCRIPTION MAKE QTY.


33KV VCB

33kV, 800Amp. 26.3kA/3sec. EDO


VCB 1 No. Closing Coil : 110V DC 1
No. Shunt Trip Coil : 110V DC
Additional Shunt Trip Coil : 110V
DC 1 No. Spring Charge Motor :
230V AC Automatic Safety
1 Shutters Operation Counter ABB 1
25A Standard Mounting TNC
2 Switch, AuxContact: 2NO+2NC CG/C&S 1
NUMERICAL PROTECTION RELAY,
HAVING FOLLOWING Make should be ABB,
PROTECTIONS 3O/C + 1 E/F HIGH Schneider or Simens
SET TRIP CIRCUIT SUPERVISION
RELAY COMMUNICATION
PORT(50,51,50N,51N, 86, 27, 59,
74, 74TC, 81 U/O, 95, 80 DC, 80
3 AC) CG/C&S 1
Single element Lockout (Mater
Trip) Relay with Hand reset
contact and Flag, Contacts:
4 3NO+2NC, Aux. Supply: 110V DC C&S/CG 1
Two element Auxiliary Relay, self
reset contacts with operation
indicator, Flush mounting ,
Contact: 12.01.2022, Voltage:
5 110V DC C&S/CG 4
4A Auxiliary Contactor, Coil: 110V
DC, Aux. Contact: 2NO+2NC, Type:
6 MX0 22E C&S/CG 4
CURRENT TRANSFORMER DUAL
RATIO, DUAL CORE SINGLE Phase
TYPE : RESIN CAST 33kV RATIO :
100/1-1 A CORE-1 : CL-0.2s, 15VA
7 CORE-2 : CL-5P20, 15VA SAVIO/AVCON 3

POTENTIAL TRANSFORMER, FlXED Open delta core is


TYPE SINGLE PHASE TYPE : RESIN
seperated core with
CAST RATIO : 33kV/r3 CORE-1 : CL-
CL:3P, refer SLD for
3P CORE-2 : CL-0.2 OPEN DELTA
better understand
8 CORE BURDEN :30VA SAVIO/AVCON 3
9 Power Pack 17AH DC 110V REPUTED 1

Multifunction Meter with RS485,


LCD Display, 3Ph, Parameter: VAF
+ THD (V & I), Imp-Exp kWh &
kVAh + PF + kW + THD (Power) +
RPM + kVAR + kVA + Ph. Angle +
Power On/Off + Cumulative MD +
Imp-Exp kVARh, Acc. CL: 0.2s, Aux.
Supply: 80-300V AC/DC, Size:
10 96x96, Model: Elite 446 SECURE 1
Three Phase Ammeter, Acc. Cl:
11 0.5, Model: DM3110 SCHNEIDER 1
Three Phase Voltmeter, Acc. Cl:
12 0.5, Model: DM3210 SCHNEIDER 1
Red Gen Next Pro LED Indicator
13 22.5 mm, Voltage: 64V AC/DC ESBEE 3
Yellow Gen Next Pro LED Indicator
14 22.5 mm, Voltage: 64V AC/DC ESBEE 2
Blue Gen Next Pro LED Indicator
15 22.5 mm, Voltage: 64V AC/DC ESBEE 2
Green Gen Next Pro LED Indicator
16 22.5 mm, Voltage: 110V AC/DC ESBEE 1
Amber Gen Next Pro LED Indicator
17 22.5 mm, Voltage: 110V AC/DC ESBEE 1
Blue Gen Next Pro LED Indicator
18 22.5 mm, Voltage: 110V AC/DC ESBEE 1
White Gen Next Pro LED Indicator
19 22.5 mm, Voltage: 110V AC/DC ESBEE 2
Black Flush Head Push Button 22.5
20 mm ESBEE 1
Yellow Flush Head Push Button
21 22.5 mm ESBEE 1
Blue Flush Head Push Button 22.5
22 mm ESBEE 1
23 1NO Contact Block FTC 2
24 1NC Contact Block ABB/L&T 1
Red Mushroom Head(Push - Turn)
25 Push Button 22.5 mm ELMEX/L&T 1
26 1NO Contact Block ELMEX/L&T 3
27 1NC Contact Block ELMEX/L&T 1
28 10A Toggle Switch 230V AC Reputed 1
6A 2P 2Way Local - Remote/ Auto-
Manual Switch with Center OFF,
29 60 Deg. Operation FTC 1
4 Sq.mm Fuse Terminal (Std.
30 Color),Type: UBDF 4 L&T 3
2.5 Sq.mm Feed Through Terminal
31 (Std. Color),Type: KUT 2.5 L&T 60
4 Sq.mm Disconnecting Terminal
32 (Std. Color),Type: KLTD M4 L&T 6
33 Glass Fuse 2A Reputed 3
32A Neutral Link, Channel
34 Mounting, Color: Black/Grey Reputed 1
35 6A 1P 10kA, C-Curve MCB Reputed 6
36 6A 2P 10kA, C-Curve MCB Anchor 4
37 20A 2P 10kA, C-Curve MCB Reputed 1
38 16 windows Reputed 1
39 Hooter Reputed 1
Door Switch With Openable
40 Execution Push Rod Powermat 1
41 Switch And Socket 15A, 5PIN Reputed 1
42 Panel Illumination LED Light Reputed 1
43 Thermostate Reputed 1
44 Space Heater 1
45 33KV Insulator EXPERT 6
SURGE ARRESTOR CLASS 2,30KV
46 10KA WITH FUSE 3
47 PT FUSE HINDALCO 3
48 Earthing Switch HINDALCO 1
Panel with canopy
and double door for
Panel Enclosure 14/16 outdoor application.
49 Gauge(OUTDOOR)-IP55 1

50 BUSBAR - MAIN 1
BUSBAR - VERTICAL DROPPER
51 BUSBAR 1
52 BUSBAR - EARTH 1

1 ACDB 9 IN 9 OUT 800V


A Incoming 9
SR
BOQ Description MAKE QTY
NO.
1 DZ6 Y MCCB 320A 3P Icu=36 kA Ics=30 kA L&T
LSIG 800Vac, insulation voltage 800V 9
2 63A, 3P 800V, MCCB,36KA TM,ADJ O/L Isulation
L&Tvoltage
S/C TO BE PROVIDED sould be more than
2
1000V
3 SPREADER FOR 63A 3P 800V L&T 2
4 Spreaders dsine DZ6-400Y/Z 3P C 30 T 05 L&T 9
5 ACC dsine DZ6 Extended ROH L&T 9
6 Double Compression Metal Cable Glands Bharat
(9R*3C*240SQ.MM) 9
7 Aluminium Busbar,δ=0.8 HINDALCO 1 Lot
B Outgoing 1
1 32A MCB,4P, 415V L&T 1
2 6A MCB ,SINGLE POLE L&T 1 LOT
3 Aluminium Busbar,δ=0.8 HINDALCO 1 LOT
4 Red Indicating Lamp 22.5mm with ESSBEE
Integrated LED, Voltage: 220V AC For Qty depends on no.
On of individual loads 1LOT
5 Green Indicating Lamp 22.5mm with ESSBEE
connected like space
Integrated LED, Voltage: 220V AC For heater, thermostate,
Off door lamps, etc. 1 LOT
6 Orange Indicating Lamp 22.5mm with ESSBEE
Integrated LED, Voltage: 220V AC For 1 LOT
Trip

7 HT Sleeve Reputed 1 LOT


8 Nut & Bolt SS 304 1 LOT
9 Space Heater 230V & Thermostate (0- Reputed
75),230V 1
10 Double Compression Metal Cable Glands Bharat
(9R*3C*240SQ.MM) 9
11 Base 75*40mm Reputed 1
12 Auxiliary Contact L&T 18
13 Control MCB 6A,Single Pole L&T 3
14 Door Light For Panel 230V Reputed 1 LOT
15 Neutral Link Reputed 1
S.N. GENERAL MAKE
DESCRIPTION QTY
(Subject to alteration & Ground
Mounting,1.6 MM Body Panel with canopy
&Partitions,sheet,Gland Plate - 3MM , and double door for
Paint: RAL 7035 (Outdoor) Door, Body outdoor application.
and Mounting Plate, 7 tank
Powder Coated Cable Entry: All Cable
entries Bottom through gland plates.
CABLE Entry Bottom 1
BusBars: All busbars will be
Aluminium EC Grade insulated with
colour coded PVC heat shrinkable
sleeves.
Eaíthing: Eaíthing busbaror stud
through out of panel whichever may
applicable. 1
FR Insulated Wiring: All wiring using POLYCAB/FINOLEX/HAVE
appropriate size ISImake flexible wires.
(Make- Polycab/Finolex/Havells/RR) LL S/RR 1

1 ACDB 8 IN 8 OUT 800V


A Incoming 8
SR. BOQ Description MAKE
1 DZ6 Y MCCB 320A 3P Icu=36 kA L&T 7
Ics=30 kA LSIG 800Vac,
insulation voltage 1250V
2 Spreaders dsine DZ6-400Y/Z 3P L&T 7
C 30 T 05
3 ACC dsine DZ6 Extended ROH L&T 7
4 DZ6 Y MCCB 63A 3P Icu=36 kA L&T 1
Ics=30 kA Thermal Magnetic
Released 800Vac, insulation
voltage 1250V
5 Spreaders dsine DZ6-400Y/Z 3P L&T 1
C 30 T 05
6 ACC dsine DZ6 Extended ROH L&T 1
7 Double Compression Metal Bharat 8
Cable Glands
(8R*3C*240SQ.MM)
8 Aluminium Busbar,δ=0.8 HINDALCO 1 Lot
B Outgoing 1
6A MCB also required - Qty
32A MCB 4P 415V L&T
depends on no. of 1
1 Aluminium Busbar,δ=0.8 HINDALCO
individual loads connected 1 LOT
2 Red Indicating Lamp 22.5mm ESSBEE
like space heater, 1 LOT
with Integrated LED, Voltage: thermostate, door lamps,
220V AC For ON etc.
3 Green Indicating Lamp 22.5mm ESSBEE 1 LOT
with Integrated LED, Voltage:
220V AC For Off
4 Orange Indicating Lamp ESSBEE 1 LOT
22.5mm with Integrated LED,
Voltage: 2200V AC For Trip
5 HT Sleeve Reputed 1 LOT
7 Nut & Bolt SS 304 1 LOT
8 Space Heater & Thermostate (0- Reputed 1
75),230V
9 Double Compression Metal Bharat 8
Cable Glands
(8R*3C*240SQ.MM)
10 Base 75*40mm Reputed 1
11 Auxiliary Contact L&T 16
12 Control MCB 6A,Single Pole L&T 3
13 Door Light For Panel 230V Reputed 1 LOT
14 Neutral Link Reputed 1

(Subject to alteration &


Ground Mounting,1.6 MM
Body Panel with canopy
&Partitions,sheet,Gland Plate and double door for
- 3MM , Paint: RAL 7035 outdoor application.
(Outdoor) Door, Body and
Mounting Plate, 7 tank
Powder Coated Cable Entry:
All Cable entries Bottom
through gland plates.
1 CABLE Entry Bottom 1
BusBars: All busbars will be
Aluminium EC Grade
insulated with colour coded
PVC heat shrinkable sleeves.
Eaíthing: Eaíthing busbaror
stud through out of panel
2 whichever may applicable. 1
FR Insulated Wiring: All
wiring using appropriate size
ISImake flexible wires. POLYCAB/FINOLEX/HAVE
(Make-
3 Polycab/Finolex/Havells/RR) LL S/RR 1

1 ACDB 7 IN 7 OUT 800V


A Incoming 8
SR. BOQ Description MAKE
1 DZ6 Y MCCB 320A 3P Icu=36 kA L&T 7
Ics=30 kA LSIG 800Vac,
insulation voltage 1250V
2 Spreaders dsine DZ6-400Y/Z 3P L&T 7
C 30 T 05
3 ACC dsine DZ6 Extended ROH L&T 7
4 DZ6 Y MCCB 63A 3P Icu=36 kA L&T 1
Ics=30 kA Thermal Magnetic
Released 800Vac, insulation
voltage 1250V
5 Spreaders dsine DZ6-400Y/Z 3P L&T 1
C 30 T 05
6 ACC dsine DZ6 Extended ROH L&T 1
7 Double Compression Metal Bharat 8
Cable Glands
(8R*3C*240SQ.MM)
8 Aluminium Busbar,δ=0.8 HINDALCO 1 Lot
B Outgoing 1
32A MCB 4P 415V L&T 1
1 Aluminium Busbar,δ=0.8
6A MCB also required
HINDALCO 1 LOT
- Qty depends on no.
2 Red Indicating Lamp 22.5mm ESSBEEloads
of individual 1 LOT
with Integrated LED, Voltage:
connected like space
220V AC For ON
heater, thermostate,
3 Green Indicating Lamp 22.5mm ESSBEEetc.
door lamps, 1 LOT
with Integrated LED, Voltage:
220V AC For Off
4 Orange Indicating Lamp ESSBEE 1 LOT
22.5mm with Integrated LED,
Voltage: 2200V AC For Trip
5 HT Sleeve Reputed 1 LOT
7 Nut & Bolt SS 304 1 LOT
8 Space Heater & Thermostate (0- Reputed 1
75),230V
9 Double Compression Metal Bharat 8
Cable Glands
(8R*3C*240SQ.MM)
10 Base 75*40mm Reputed 1
11 Auxiliary Contact L&T 16
12 Control MCB 6A,Single Pole L&T 3
13 Door Light For Panel 230V Reputed 1 LOT
14 Neutral Link Reputed 1

(Subject to alteration &


Ground Mounting,1.6 MM
Body
&Partitions,sheet,Gland Plate
- 3MM , Paint: RAL 7035
(Outdoor) Door, Body and Panel with canopy
Mounting Plate, 7 tank and double door for
Powder Coated Cable Entry: outdoor application.
All Cable entries Bottom
through gland plates.
1 CABLE Entry Bottom 1
BusBars: All busbars will be
Aluminium EC Grade
insulated with colour coded
PVC heat shrinkable sleeves.
Eaíthing: Eaíthing busbaror
stud through out of panel
2 whichever may applicable. 1
FR Insulated Wiring: All
wiring using appropriate size
ISImake flexible wires. POLYCAB/FINOLEX/HAVE
(Make-
3 Polycab/Finolex/Havells/RR) LL S/RR 1
Auxiliary Panel 63A
S. Item Description Make Qty. Unit
No.
INCOMING
63A TP MCCB 18KA L&T 1 NOS
WITH O/L, S/C,
THERMAL MAGNETIC
RELEASE 415 V
1
2 SPREADER LINK L&T 1 NOS
DIGITAL MFM CL-0.5 SECURE 1 NOS
RS485 COMPATIBLE
3
SPD TYPE 2 40 A WITH CETEL 1 NOS
4 FUSE
5 CT 60/5A CL: 0.5 AE 3 NOS
ON/OFF INDICATION L&T 2 NOS
6 LAMP
AUX CONTACT BLOCK L&T 1 NOS
7
PHASE INDICATION L&T 3 NOS
8 LAMP
9 CONTROL MCB L&T 3 NOS
10 NEUTRAL LINK REPUTED 1 NOS
6-10-32A DP MCB 10KA L&T 11 NOS
11
12 16A TPN MCB 10KA L&T 4 NOS
SPACE HEATER & Reputed 1 NOS
13 THERMOSTAT
ILLUMINATING LAMP Reputed 1 NOS
14 230V

(Subject to alteration &


Ground Mounting,1.6 MM
Body Panel with canopy
&Partitions,sheet,Gland and double door for
Plate - 3MM , Paint: RAL outdoor application.
7035 (Outdoor) Door, Body
and Mounting Plate, 7 tank

Powder Coated Cable Entry:


All Cable entries Bottom
through gland plates.

1 CABLE Entry Bottom 1 JOB


BusBars: All busbars will be 1 LOT
Aluminium EC Grade
insulated with colour coded
PVC heat shrinkable sleeves.

Eaíthing: Eaíthing busbaror


stud through out of panel
whichever may applicable.
2
FR Insulated Wiring: All POLYCAB/FINOLEX/HAVE 1 LOT
wiring using appropriate size
ISImake flexible wires.
(Make-
LL S/RR
3 Polycab/Finolex/Havells/RR)
Annexure – II
Commercial Terms

PRICE - EX-NOIDA

VALIDITY- This offer is valid for 30 days from the date hereof.
TRANSIT By Purchaser.
INSURANCE -
FRIGHT - Extra
GST - Extra
PAYMENT - 50 % Advance with technically and commercially clear with purchase
order Remaining on PI before delivery.
DISPATCH - Within 60-75 working days.

WARRANTY - 12 months from commissioning or 14 months from dispatch, whichever is


earlier, for material and workmanship?
Annexure - III
Technical Details

 Our offer is based upon the BOQ enclosed. Any deviation from the enclosed BOM shall be
charged extra.
 Make of Equipment’s considered shall be as per BOQ enclosed.
 Main bus bar shall be electrolytic grade AL while earth bus bar shall be AL.
 MS Structures shall be pre-treated in seven tank chemical processes, heated in baking oven
and finally finished in Siemens grey (RAL-7035) paint in structure finish.
 We shall provide Powder Coating of 60-80 micron of approved shade.
 Structure shall be 2.0 mm & door shall be 2.0 mm CRCA Sheet Steel.
 We shall provide Zinc Passivity MS hardware.
 Panels shall be single door outdoor type with canopy, ingress Protection degree of IP-4x .
 Cable lugs & gland shall not be in our scope of supply.
 Voltage circuits shall be protected through 6A, SP MCB with bolted type neutral link.
 Internal wiring of the panel shall be carried out using PVC insulated, copper flexible wire of
1.5 mm2 for Voltage circuits and 2.5 mm2 for Current circuits.
Annexure – IV
Price Details

Price Schedule
TOTAL
S. NO. DESCRIPTION QTY UNIT PRICE AMOUNT
1 11KV VCB PANEL 1 NOS. ₹ 3,55,000.00 ₹ 3,55,000.00
2 33KV VCB PANEL 1 NOS. ₹ 8,40,000.00 ₹ 8,40,000.00
3 LT PANEL 9 IN 9 OUT 1 NOS. ₹ 6,59,912.00 ₹ 6,59,912.00
LT PANEL 8 IN 8 OUT 1 ₹ 5,01,285.00 ₹ 5,01,285.00
LT PANEL 7 IN 7 OUT 1 ₹ 5,31,362.00 ₹ 5,31,362.00
AUXILLIARY PANEL
4 63A 2 NOS. ₹ 63,896.00 ₹ 63,896.00
TOTAL PRICE ₹3,01,535.00
Note :

1. Our Offer is subjected to our BOQ, If there are any changes in BOQ &Qty then price
shall be charged extra.

*** THANKS FOR YOUR CONSIDERATION ***

You might also like